Jae Young Byun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jae Young Byun has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Sung Eun Rha
Department of Radiology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
7 shared publications Seung Eun Jung
Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea; Cancer Research Institute, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
6 shared publicationsSoon Nam Oh
Department of Radiology and Cancer Research Institute, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea
5 shared publications- Seung Eun Jung
Department of Radiology, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
4 shared publications - Byung Gil Choi
Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
3 shared publications - Joon-Il Choi
Department of Radiology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
3 shared publications
Latest Publications
- 1 February 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (2) , 202-208
Educational Effects of Radiation Reduction During Fluoroscopic Examination of the Adult Gastrointestinal Tract
- 1 February 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (2) , 202-208
Educational Effects of Radiation Reduction During Fluoroscopic Examination of the Adult Gastrointestinal Tract
- 18 December 2016
- Published by Elsevier in Clinical Nutrition
- Vol. 37 (1) , 214-222
Validation of intimate correlation between visceral fat and hepatic steatosis: Quantitative measurement techniques using CT for area of fat and MR for hepatic steatosis
- 18 December 2016
- Published by Elsevier in Clinical Nutrition
- Vol. 37 (1) , 214-222
Validation of intimate correlation between visceral fat and hepatic steatosis: Quantitative measurement techniques using CT for area of fat and MR for hepatic steatosis
- 1 September 2016
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 44 (9) , 1479-1484
Prognostic CT findings of diplopia after surgical repair of pure orbital blowout fracture
- 1 September 2016
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 44 (9) , 1479-1484
Prognostic CT findings of diplopia after surgical repair of pure orbital blowout fracture
- Open Access
- 15 March 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 328
Optimization of beam-flow angles for Doppler ultrasound flow velocity measurements using slanted gel pads
- 15 March 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 328
Open AccessOptimization of beam-flow angles for Doppler ultrasound flow velocity measurements using slanted gel pads
- Open Access
- 1 January 2016
- Published by XMLink in Journal of Korean Medical Science
- Vol. 31 (Suppl 1) , S55-S58
Factors Related to Radiation Exposure during Lumbar Spine Intervention
Choi MH, et al. J Korean Med Sci. 2016 Feb;31(Suppl 1):S55-S58. http://dx.doi.org/10.3346/jkms.2016.31.S1.S55
- 1 January 2016
- Published by XMLink in Journal of Korean Medical Science
- Vol. 31 (Suppl 1) , S55-S58
Open AccessFactors Related to Radiation Exposure during Lumbar Spine Intervention
Choi MH, et al. J Korean Med Sci. 2016 Feb;31(Suppl 1):S55-S58. http://dx.doi.org/10.3346/jkms.2016.31.S1.S55
- Open Access
- 23 April 2015
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 34 (4) , 304-311
Differentiation of benign and malignant thyroid nodules based on the proportion of sponge-like areas on ultrasonography: imaging-pathologic correlation
The purpose of this study was to determine whether it is possible to differentiate benign from malignant thyroid nodules according to the proportion of sponge-like appearance within the nodules. A total of 201 thyroid nodules containing sponge-like appearance from 195 patients (157 women and 38 men) were included this study. Each thyroid nodule was classified into one of three grades by real-time ultrasonography (US) based on the areas with a sponge-like appearance within nodule: grade I had sponge-like areas occupying 75%. We evaluated whether a correlation existed between these grades and cytopathologic diagnoses. Of the 201 nodules, 196 were benign and five were malignant, and according to the US classification, 101 nodules were grade I, 45 were grade II, and 55 were grade III. Of the five malignant nodules, four were grade I, and one was grade II. No statistically significant difference was found in the rate of malignancy between grade III and grades I and II, due to insufficient statistical power. A sponge-like appearance was correlated with follicles filled with colloid and cholesterol granules in benign nodules and with papillary fronds around the dilated cystic spaces in malignant nodules. No malignancies were found in thyroid nodules with >75% sponge-like appearance. Due to the overall low incidence of malignancy and the limited number of patients, a statistically significant difference could not be found in the prevalence of malignancy depending on the proportion of sponge-like areas within the nodule.
- 23 April 2015
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 34 (4) , 304-311
Open AccessDifferentiation of benign and malignant thyroid nodules based on the proportion of sponge-like areas on ultrasonography: imaging-pathologic correlation
The purpose of this study was to determine whether it is possible to differentiate benign from malignant thyroid nodules according to the proportion of sponge-like appearance within the nodules. A total of 201 thyroid nodules containing sponge-like appearance from 195 patients (157 women and 38 men) were included this study. Each thyroid nodule was classified into one of three grades by real-time ultrasonography (US) based on the areas with a sponge-like appearance within nodule: grade I had sponge-like areas occupying 75%. We evaluated whether a correlation existed between these grades and cytopathologic diagnoses. Of the 201 nodules, 196 were benign and five were malignant, and according to the US classification, 101 nodules were grade I, 45 were grade II, and 55 were grade III. Of the five malignant nodules, four were grade I, and one was grade II. No statistically significant difference was found in the rate of malignancy between grade III and grades I and II, due to insufficient statistical power. A sponge-like appearance was correlated with follicles filled with colloid and cholesterol granules in benign nodules and with papillary fronds around the dilated cystic spaces in malignant nodules. No malignancies were found in thyroid nodules with >75% sponge-like appearance. Due to the overall low incidence of malignancy and the limited number of patients, a statistically significant difference could not be found in the prevalence of malignancy depending on the proportion of sponge-like areas within the nodule.
- 1 April 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (4) , 590-595
Diffusion-weighted MRI of epithelial ovarian cancers: Correlation of apparent diffusion coefficient values with histologic grade and surgical stage
- 1 April 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (4) , 590-595
Diffusion-weighted MRI of epithelial ovarian cancers: Correlation of apparent diffusion coefficient values with histologic grade and surgical stage
- 1 November 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 203 (5) , W563
The AJR Homepage: Robots.txt and Negative Effect on Search Engines
- 1 November 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 203 (5) , W563
The AJR Homepage: Robots.txt and Negative Effect on Search Engines
- Open Access
- 26 February 2014
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 33 (2) , 91-97
Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. Three radiologists (a resident, and two board-certified radiologists with 2 and 7 years of experience in evaluating ultrasound phantom images) performed the gray scale/dynamic range test for an ultrasound machine using a standardized phantom. They scored the number of visible cylindrical structures of varying degrees of brightness and made a 'pass or fail' decision. First, they scored 49 phantom images twice from a 2010 survey with limited knowledge of phantom images. After this, the radiologists underwent two hours of interactive education for the phantom images and scored another 91 phantom images from a 2011 survey twice. Intra- and interobserver reliability before and after the interactive education session were analyzed using K analyses. Before education, the K-value for intraobserver reliability for the radiologist with 7 years of experience, 2 years of experience, and the resident was 0.386, 0.469, and 0.465, respectively. After education, the K-values were improved (0.823, 0.611, and 0.711, respectively). For interobserver reliability, the K-value was also better after the education for the 3 participants (0.067, 0.002, and 0.547 before education; 0.635, 0.667, and 0.616 after education, respectively). The intra- and interobserver reliability of the gray scale/dynamic range was fair to substantial. Interactive education can improve reliability. For more reliable results, double- checking of phantom images by multiple reviewers is recommended.
- 26 February 2014
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 33 (2) , 91-97
Open AccessIntra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. Three radiologists (a resident, and two board-certified radiologists with 2 and 7 years of experience in evaluating ultrasound phantom images) performed the gray scale/dynamic range test for an ultrasound machine using a standardized phantom. They scored the number of visible cylindrical structures of varying degrees of brightness and made a 'pass or fail' decision. First, they scored 49 phantom images twice from a 2010 survey with limited knowledge of phantom images. After this, the radiologists underwent two hours of interactive education for the phantom images and scored another 91 phantom images from a 2011 survey twice. Intra- and interobserver reliability before and after the interactive education session were analyzed using K analyses. Before education, the K-value for intraobserver reliability for the radiologist with 7 years of experience, 2 years of experience, and the resident was 0.386, 0.469, and 0.465, respectively. After education, the K-values were improved (0.823, 0.611, and 0.711, respectively). For interobserver reliability, the K-value was also better after the education for the 3 participants (0.067, 0.002, and 0.547 before education; 0.635, 0.667, and 0.616 after education, respectively). The intra- and interobserver reliability of the gray scale/dynamic range was fair to substantial. Interactive education can improve reliability. For more reliable results, double- checking of phantom images by multiple reviewers is recommended.
- Open Access
- 1 January 2014
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 70 (4) , 283-289
In VivoLocation of the Vermiform Appendix in Multidetector CT
Lee SL, et al. J Korean Soc Radiol. 2014 Apr;70(4):283-289. http://dx.doi.org/10.3348/jksr.2014.70.4.283
- 1 January 2014
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 70 (4) , 283-289
Open AccessIn VivoLocation of the Vermiform Appendix in Multidetector CT
Lee SL, et al. J Korean Soc Radiol. 2014 Apr;70(4):283-289. http://dx.doi.org/10.3348/jksr.2014.70.4.283