Osama Mawlawi
Research Subjects
Research Interests
Osama Mawlawi has a total of 201 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Joseph Lazar
Department of Genomic Medicine, The University of Texas MD Anderson Cancer Center, Houston, Texas
12 shared publications - Cansu Karakas
Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
12 shared publications - Davis R. Ingram
Department of Pathology, Division of Pathology & Laboratory Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX
12 shared publications - Kelly K. Hunt
Department of Breast Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
12 shared publications - Khandan Keyomarsi
Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
12 shared publications - Linjie Luo
Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
12 shared publications
Latest Publications
- Open Access
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Supplementary Tables from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
This file contains 6 supplementary tables referred to in the text of the manuscript
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Tables from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
This file contains 6 supplementary tables referred to in the text of the manuscript
- Open Access
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Supplementary Materials and Methods from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
This file contains the description of supplementary materials and methods that is referred to in the manuscript
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Materials and Methods from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
This file contains the description of supplementary materials and methods that is referred to in the manuscript
- Open Access
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Supplemental Figures and Figure legends from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
This File contains all the supplemental figures and figure legends referred to in the main text.
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Open AccessSupplemental Figures and Figure legends from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
This File contains all the supplemental figures and figure legends referred to in the main text.
- Open Access
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Data from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
Treatment strategies with a strong scientific rationale based on specific biomarkers are needed to improve outcomes in patients with advanced sarcomas. Suppression of cell-cycle progression through reactivation of the tumor suppressor retinoblastoma (Rb) using CDK4/6 inhibitors is a potential avenue for novel targeted therapies in sarcomas that harbor intact Rb signaling. Here, we evaluated combination treatment strategies (sequential and concomitant) with the CDK4/6 inhibitor abemacicib to identify optimal combination strategies. Expression of Rb was examined in 1,043 sarcoma tumor specimens, and 50% were found to be Rb-positive. Using in vitro and in vivo models, an effective two-step sequential combination strategy was developed. Abemaciclib was used first to prime Rb-positive sarcoma cells to reversibly arrest in G1 phase. Upon drug removal, cells synchronously traversed to S phase, where a second treatment with S-phase targeted agents (gemcitabine or Wee1 kinase inhibitor) mediated a synergistic response by inducing DNA damage. The response to treatment could be noninvasively monitored using real-time positron emission tomography imaging and serum thymidine kinase activity. Collectively, these results show that a novel, sequential treatment strategy with a CDK4/6 inhibitor followed by a DNA-damaging agent was effective, resulting in synergistic tumor cell killing. This approach can be readily translated into a clinical trial with noninvasive functional imaging and serum biomarkers as indicators of response and cell cycling.Significance:An innovative sequential therapeutic strategy targeting Rb, followed by treatment with agents that perturb DNA synthesis pathways, results in synergistic killing of Rb-positive sarcomas that can be noninvasively monitored.
- 24 November 2025
- Published by American Association for Cancer Research (AACR)
Open AccessData from Sequential Targeting of Retinoblastoma and DNA Synthesis Pathways Is a Therapeutic Strategy for Sarcomas That Can Be Monitored in Real Time
Treatment strategies with a strong scientific rationale based on specific biomarkers are needed to improve outcomes in patients with advanced sarcomas. Suppression of cell-cycle progression through reactivation of the tumor suppressor retinoblastoma (Rb) using CDK4/6 inhibitors is a potential avenue for novel targeted therapies in sarcomas that harbor intact Rb signaling. Here, we evaluated combination treatment strategies (sequential and concomitant) with the CDK4/6 inhibitor abemacicib to identify optimal combination strategies. Expression of Rb was examined in 1,043 sarcoma tumor specimens, and 50% were found to be Rb-positive. Using in vitro and in vivo models, an effective two-step sequential combination strategy was developed. Abemaciclib was used first to prime Rb-positive sarcoma cells to reversibly arrest in G1 phase. Upon drug removal, cells synchronously traversed to S phase, where a second treatment with S-phase targeted agents (gemcitabine or Wee1 kinase inhibitor) mediated a synergistic response by inducing DNA damage. The response to treatment could be noninvasively monitored using real-time positron emission tomography imaging and serum thymidine kinase activity. Collectively, these results show that a novel, sequential treatment strategy with a CDK4/6 inhibitor followed by a DNA-damaging agent was effective, resulting in synergistic tumor cell killing. This approach can be readily translated into a clinical trial with noninvasive functional imaging and serum biomarkers as indicators of response and cell cycling.Significance:An innovative sequential therapeutic strategy targeting Rb, followed by treatment with agents that perturb DNA synthesis pathways, results in synergistic killing of Rb-positive sarcomas that can be noninvasively monitored.
- 23 December 2024
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 20 (Special ) , 49-54
First PET Studies of a FLASH Proton Beam: Summary and Future Prospects
Objectives: Proton therapy, while highly effective and successful, still lacks a key feature: the ability to assess, in-vivo, the dose and end-point location of irradiations. Known as proton range verification, this capability can be realized by incorporating positron emission tomography (PET) systems in both conventional and emerging modalities, such as FLASH proton therapy. FLASH itself may revolutionize radiation oncology with its purported ability to better spare healthy tissues, but only if the underlying mechanisms can be understood. We summarize our work towards establishing in-beam PET modalities and elucidating the mystery of the FLASH effect. Materials: We've developed a PET scanner designed for live, in-beam imaging during therapeutic proton irradiations that can use short-lived positron emitting species (PES) activated by the beam to validate the range and dose of proton depositions. This scanner is made up of PET modules consisting of arrays of LYSO (lutetium-yttrium oxyorthosilicate) scintillating crystals coupled one-to-one to silicon photomultiplier (SiPM) arrays. These modules are readout by electronics based on the TOFPET2 ASIC platform from PETsys Electronics. Methods: Our collaboration with MD Anderson Cancer Center has given us opportunities to take real in-beam data using a non-clinical beamline capable of delivering FLASH proton irradiations into target phantoms made of polymethyl methacrylate (PMMA), high density polyethylene (HDPE), and water. Data collected both during and afterirradiations were used to perform novel analyses and to reconstruct images of PES activity due to the beam. Results: Exploratory studies, using a subset of our PET scanner, have demonstrated successful data acquisition during and after FLASH beam spills including quantitative imaging and dosimetry of activated phantoms. The full results, explored in this work, are highly promising and prove that in-beam PET can deliver on its goals. Upcoming experiments conducted using both FLASH and conventional beams will employ the full PET scanner and involve a rich experimental program with novel ideas for irradiation targets, beam characterization, and in-depth comparisons of the two irradiation modalities. Conclusions: This work demonstrates the unprecedented proof-of-principle for the capabilities of an in-beam PET scanner for imaging and dosimetry of both conventional and FLASH proton beams. These results open a new PET modality with proton beams which is particularly attractive for FLASH therapy but can serve effectively all proton irradiations, leading to improved treatment monitoring and image-guided therapy.
- 23 December 2024
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 20 (Special ) , 49-54
First PET Studies of a FLASH Proton Beam: Summary and Future Prospects
Objectives: Proton therapy, while highly effective and successful, still lacks a key feature: the ability to assess, in-vivo, the dose and end-point location of irradiations. Known as proton range verification, this capability can be realized by incorporating positron emission tomography (PET) systems in both conventional and emerging modalities, such as FLASH proton therapy. FLASH itself may revolutionize radiation oncology with its purported ability to better spare healthy tissues, but only if the underlying mechanisms can be understood. We summarize our work towards establishing in-beam PET modalities and elucidating the mystery of the FLASH effect. Materials: We've developed a PET scanner designed for live, in-beam imaging during therapeutic proton irradiations that can use short-lived positron emitting species (PES) activated by the beam to validate the range and dose of proton depositions. This scanner is made up of PET modules consisting of arrays of LYSO (lutetium-yttrium oxyorthosilicate) scintillating crystals coupled one-to-one to silicon photomultiplier (SiPM) arrays. These modules are readout by electronics based on the TOFPET2 ASIC platform from PETsys Electronics. Methods: Our collaboration with MD Anderson Cancer Center has given us opportunities to take real in-beam data using a non-clinical beamline capable of delivering FLASH proton irradiations into target phantoms made of polymethyl methacrylate (PMMA), high density polyethylene (HDPE), and water. Data collected both during and afterirradiations were used to perform novel analyses and to reconstruct images of PES activity due to the beam. Results: Exploratory studies, using a subset of our PET scanner, have demonstrated successful data acquisition during and after FLASH beam spills including quantitative imaging and dosimetry of activated phantoms. The full results, explored in this work, are highly promising and prove that in-beam PET can deliver on its goals. Upcoming experiments conducted using both FLASH and conventional beams will employ the full PET scanner and involve a rich experimental program with novel ideas for irradiation targets, beam characterization, and in-depth comparisons of the two irradiation modalities. Conclusions: This work demonstrates the unprecedented proof-of-principle for the capabilities of an in-beam PET scanner for imaging and dosimetry of both conventional and FLASH proton beams. These results open a new PET modality with proton beams which is particularly attractive for FLASH therapy but can serve effectively all proton irradiations, leading to improved treatment monitoring and image-guided therapy.
- Open Access
LegoPET: Hierarchical Feature Guided Conditional Diffusion for PET Image Reconstruction
Positron emission tomography (PET) is widely utilized for cancer detection due to its ability to visualize functional and biological processes in vivo. PET images are usually reconstructed from histogrammed raw data (sinograms) using traditional iterative techniques (e.g., OSEM, MLEM). Recently, deep learning (DL) methods have shown promise by directly mapping raw sinogram data to PET images. However, DL approaches that are regression-based or GAN-based often produce overly smoothed images or introduce various artifacts respectively. Image-conditioned diffusion probabilistic models (cDPMs) are another class of likelihood-based DL techniques capable of generating highly realistic and controllable images. While cDPMs have notable strengths, they still face challenges such as maintain correspondence and consistency between input and output images when they are from different domains (e.g., sinogram vs. image domain) as well as slow convergence rates. To address these limitations, we introduce LegoPET, a hierarchical feature guided conditional diffusion model for high-perceptual quality PET image reconstruction from sinograms. We conducted several experiments demonstrating that LegoPET not only improves the performance of cDPMs but also surpasses recent DL-based PET image reconstruction techniques in terms of visual quality and pixel-level PSNR/SSIM metrics. Our code is available at https://github.com/yransun/LegoPET.
Open AccessLegoPET: Hierarchical Feature Guided Conditional Diffusion for PET Image Reconstruction
Positron emission tomography (PET) is widely utilized for cancer detection due to its ability to visualize functional and biological processes in vivo. PET images are usually reconstructed from histogrammed raw data (sinograms) using traditional iterative techniques (e.g., OSEM, MLEM). Recently, deep learning (DL) methods have shown promise by directly mapping raw sinogram data to PET images. However, DL approaches that are regression-based or GAN-based often produce overly smoothed images or introduce various artifacts respectively. Image-conditioned diffusion probabilistic models (cDPMs) are another class of likelihood-based DL techniques capable of generating highly realistic and controllable images. While cDPMs have notable strengths, they still face challenges such as maintain correspondence and consistency between input and output images when they are from different domains (e.g., sinogram vs. image domain) as well as slow convergence rates. To address these limitations, we introduce LegoPET, a hierarchical feature guided conditional diffusion model for high-perceptual quality PET image reconstruction from sinograms. We conducted several experiments demonstrating that LegoPET not only improves the performance of cDPMs but also surpasses recent DL-based PET image reconstruction techniques in terms of visual quality and pixel-level PSNR/SSIM metrics. Our code is available at https://github.com/yransun/LegoPET.
- Open Access
DIFR3CT: Latent Diffusion for Probabilistic 3D CT Reconstruction from Few Planar X-Rays
Computed Tomography (CT) scans are the standard-of-care for the visualization and diagnosis of many clinical ailments, and are needed for the treatment planning of external beam radiotherapy. Unfortunately, the availability of CT scanners in low- and mid-resource settings is highly variable. Planar x-ray radiography units, in comparison, are far more prevalent, but can only provide limited 2D observations of the 3D anatomy. In this work we propose DIFR3CT, a 3D latent diffusion model, that can generate a distribution of plausible CT volumes from one or few (<10) planar x-ray observations. DIFR3CT works by fusing 2D features from each x-ray into a joint 3D space, and performing diffusion conditioned on these fused features in a low-dimensional latent space. We conduct extensive experiments demonstrating that DIFR3CT is better than recent sparse CT reconstruction baselines in terms of standard pixel-level (PSNR, SSIM) on both the public LIDC and in-house post-mastectomy CT datasets. We also show that DIFR3CT supports uncertainty quantification via Monte Carlo sampling, which provides an opportunity to measure reconstruction reliability. Finally, we perform a preliminary pilot study evaluating DIFR3CT for automated breast radiotherapy contouring and planning -- and demonstrate promising feasibility. Our code is available at https://github.com/yransun/DIFR3CT.
Open AccessDIFR3CT: Latent Diffusion for Probabilistic 3D CT Reconstruction from Few Planar X-Rays
Computed Tomography (CT) scans are the standard-of-care for the visualization and diagnosis of many clinical ailments, and are needed for the treatment planning of external beam radiotherapy. Unfortunately, the availability of CT scanners in low- and mid-resource settings is highly variable. Planar x-ray radiography units, in comparison, are far more prevalent, but can only provide limited 2D observations of the 3D anatomy. In this work we propose DIFR3CT, a 3D latent diffusion model, that can generate a distribution of plausible CT volumes from one or few (<10) planar x-ray observations. DIFR3CT works by fusing 2D features from each x-ray into a joint 3D space, and performing diffusion conditioned on these fused features in a low-dimensional latent space. We conduct extensive experiments demonstrating that DIFR3CT is better than recent sparse CT reconstruction baselines in terms of standard pixel-level (PSNR, SSIM) on both the public LIDC and in-house post-mastectomy CT datasets. We also show that DIFR3CT supports uncertainty quantification via Monte Carlo sampling, which provides an opportunity to measure reconstruction reliability. Finally, we perform a preliminary pilot study evaluating DIFR3CT for automated breast radiotherapy contouring and planning -- and demonstrate promising feasibility. Our code is available at https://github.com/yransun/DIFR3CT.
- Open Access
- 28 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14315
Performance characteristics of the 5‐ring GE Discovery MI PET/CT scanner using AAPM TG‐126 report
Aim: To report on the performance characteristics of the 5‐ring GE Discovery MI PET/CT systems using the AAPM TG‐126 report and compare these results to NEMA NU 2‐2012 where applicable.Materials and Methods: TG‐126 testing was performed on two GE 5‐Rings Discovery MI scanners. Tests performed included spatial resolution, PET/CT image‐registration accuracy, sensitivity, count rate performance, accuracy of corrections, image contrast, scatter/attenuation correction, and image uniformity. All acquired data were analyzed using scanner console or free software tools as described by TG‐126 and the results were then compared to published NEMA NU 2‐2012 values.Results: Both scanners gave similar resolution results for TG‐126 and NEMA NU 2‐2012 and were within manufacturer specifications. Image‐registration accuracy between PET and CT using our clinical protocol showed excellent results with values ≤1 mm. Sensitivity using TG‐126 was 19.43 cps/kBq while for NEMA the value was 20.73 cps/kBq. The peak noise‐equivalent counting rate was 2174 kcps at 63.1 kBq/mL and is not comparable to NEMA NU 2‐2012 due to differences in phantoms and methods used to measure and calculate this parameter. The accuracy of corrections for count losses for TG‐126 were expressed in SUV values and found to be within 10% of the expected SUV measurement of 1. Image contrast and scatter/attenuation correction using the TG‐126 method gave acceptable results. Image uniformity assessment resulted in values within the recommended ± 5% limits.Conclusion: These results show that the 5‐ring GE Discovery MI PET/CT scanner testing using TG‐126 is reproducible and has similar results to NEMA NU 2‐2012 tests where applicable. We hope these results start to form the basis to compare PET/CT systems using TG‐126.
- 28 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14315
Open AccessPerformance characteristics of the 5‐ring GE Discovery MI PET/CT scanner using AAPM TG‐126 report
Aim: To report on the performance characteristics of the 5‐ring GE Discovery MI PET/CT systems using the AAPM TG‐126 report and compare these results to NEMA NU 2‐2012 where applicable.Materials and Methods: TG‐126 testing was performed on two GE 5‐Rings Discovery MI scanners. Tests performed included spatial resolution, PET/CT image‐registration accuracy, sensitivity, count rate performance, accuracy of corrections, image contrast, scatter/attenuation correction, and image uniformity. All acquired data were analyzed using scanner console or free software tools as described by TG‐126 and the results were then compared to published NEMA NU 2‐2012 values.Results: Both scanners gave similar resolution results for TG‐126 and NEMA NU 2‐2012 and were within manufacturer specifications. Image‐registration accuracy between PET and CT using our clinical protocol showed excellent results with values ≤1 mm. Sensitivity using TG‐126 was 19.43 cps/kBq while for NEMA the value was 20.73 cps/kBq. The peak noise‐equivalent counting rate was 2174 kcps at 63.1 kBq/mL and is not comparable to NEMA NU 2‐2012 due to differences in phantoms and methods used to measure and calculate this parameter. The accuracy of corrections for count losses for TG‐126 were expressed in SUV values and found to be within 10% of the expected SUV measurement of 1. Image contrast and scatter/attenuation correction using the TG‐126 method gave acceptable results. Image uniformity assessment resulted in values within the recommended ± 5% limits.Conclusion: These results show that the 5‐ring GE Discovery MI PET/CT scanner testing using TG‐126 is reproducible and has similar results to NEMA NU 2‐2012 tests where applicable. We hope these results start to form the basis to compare PET/CT systems using TG‐126.
- Open Access
- 23 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235004
The first probe of a FLASH proton beam by PET
The recently observed FLASH effect related to high doses delivered with high rates has the potential to revolutionize radiation cancer therapy if promising results are confirmed and an underlying mechanism understood. Comprehensive measurements are essential to elucidate the phenomenon. We report the first-ever demonstration of measurements of successive in-spill and post-spill emissions of gammas arising from irradiations by a FLASH proton beam. A small positron emission tomography (PET) system was exposed in an ocular beam of the Proton Therapy Center at MD Anderson Cancer Center to view phantoms irradiated by 3.5 × 10 10 protons with a kinetic energy of 75.8 MeV delivered in 101.5 ms-long spills yielding a dose rate of 164 Gy s −1 . Most in-spill events were due to prompt gammas. Reconstructed post-spill tomographic events, recorded for up to 20 min, yielded quantitative imaging and dosimetric information. These findings open a new and novel modality for imaging and monitoring of FLASH proton therapy exploiting in-spill prompt gamma imaging followed by post-spill PET imaging.
- 23 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235004
Open AccessThe first probe of a FLASH proton beam by PET
The recently observed FLASH effect related to high doses delivered with high rates has the potential to revolutionize radiation cancer therapy if promising results are confirmed and an underlying mechanism understood. Comprehensive measurements are essential to elucidate the phenomenon. We report the first-ever demonstration of measurements of successive in-spill and post-spill emissions of gammas arising from irradiations by a FLASH proton beam. A small positron emission tomography (PET) system was exposed in an ocular beam of the Proton Therapy Center at MD Anderson Cancer Center to view phantoms irradiated by 3.5 × 10 10 protons with a kinetic energy of 75.8 MeV delivered in 101.5 ms-long spills yielding a dose rate of 164 Gy s −1 . Most in-spill events were due to prompt gammas. Reconstructed post-spill tomographic events, recorded for up to 20 min, yielded quantitative imaging and dosimetric information. These findings open a new and novel modality for imaging and monitoring of FLASH proton therapy exploiting in-spill prompt gamma imaging followed by post-spill PET imaging.
- Open Access
Dosimetry of a Novel 111Indium-Labeled Anti-P-Cadherin Monoclonal Antibody (FF-21101) in Non-Human Primates
P-cadherin is associated with a wide range of tumor types, making it an attractive therapeutic target. FF-21101 is a human–mouse chimeric monoclonal antibody (mAb) directed against human P-cadherin, which has been radioconjugated with indium-111 (111In) utilizing a DOTA chelator. We investigated the biodistribution of FF-21101(111In) in cynomolgus macaques and extrapolated the results to estimate internal radiation doses of 111In- and yttrium-90 (90Y)-FF-21101 for targeted radioimmunotherapy in humans. Whole-body planar and SPECT imaging were performed at 0, 2, 24, 48, 72, 96, and 120 h post-injection, using a dual-head gamma camera. Volumes of interest of identifiable source organs of radioactivity were defined on aligned reference CT and serial SPECT images. Organs with the highest estimated dose values (mSv/MBq) for FF-21101(111In) were the lungs (0.840), spleen (0.816), liver (0.751), kidneys (0.629), and heart wall (0.451); and for FF-21101(90Y) dose values were: lungs (10.49), spleen (8.21), kidneys (5.92), liver (5.46), and heart wall (2.61). FF-21101(111In) exhibits favorable biodistribution in cynomolgus macaques and estimated human dosimetric characteristics. Data obtained in this study were used to support the filing of an investigational new drug application with the FDA for a Phase I clinical trial.
Open AccessDosimetry of a Novel 111Indium-Labeled Anti-P-Cadherin Monoclonal Antibody (FF-21101) in Non-Human Primates
P-cadherin is associated with a wide range of tumor types, making it an attractive therapeutic target. FF-21101 is a human–mouse chimeric monoclonal antibody (mAb) directed against human P-cadherin, which has been radioconjugated with indium-111 (111In) utilizing a DOTA chelator. We investigated the biodistribution of FF-21101(111In) in cynomolgus macaques and extrapolated the results to estimate internal radiation doses of 111In- and yttrium-90 (90Y)-FF-21101 for targeted radioimmunotherapy in humans. Whole-body planar and SPECT imaging were performed at 0, 2, 24, 48, 72, 96, and 120 h post-injection, using a dual-head gamma camera. Volumes of interest of identifiable source organs of radioactivity were defined on aligned reference CT and serial SPECT images. Organs with the highest estimated dose values (mSv/MBq) for FF-21101(111In) were the lungs (0.840), spleen (0.816), liver (0.751), kidneys (0.629), and heart wall (0.451); and for FF-21101(90Y) dose values were: lungs (10.49), spleen (8.21), kidneys (5.92), liver (5.46), and heart wall (2.61). FF-21101(111In) exhibits favorable biodistribution in cynomolgus macaques and estimated human dosimetric characteristics. Data obtained in this study were used to support the filing of an investigational new drug application with the FDA for a Phase I clinical trial.