NHNooshin Haghighipour

Nooshin Haghighipour

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nooshin Haghighipour has a total of 177 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • PCL SCAFFOLDS WITH HARDYSTONITE AND MAGNETITE NANOPARTICLES UNDER A PULSED MAGNETIC FIELD FOR BONE TISSUE ENGINEERING

    by Narmin Zarinabadi, Roozbeh Abedini-Nassab, Amin Hadi, Nooshin Haghighipour

    Achieving scaffolds with suitable mechanical properties and bioactivity is a crucial need for bone tissue engineering. In this study, we present novel 3D-printed scaffolds composed of poly([Formula: see text]-caprolactone) (PCL), hardystonite (HT), and Fe 3 O 4 magnetic nanoparticles, designed to combine enhanced mechanical stiffness suitability with responsiveness to pulsed magnetic fields. Scaffold hydrophilicity, degradation, pH stability, and mechanical performance were systematically evaluated in both solid and porous samples, alongside cellular viability and morphology of MG63 and L929 cells under magnetic stimulation. Incorporation of 10[Formula: see text]wt.% HT and 4[Formula: see text]wt.% Fe 3 O 4 significantly improved scaffold hydrophilicity (contact angle [Formula: see text]) and mechanical strength, with Young’s modulus and toughness increasing up to 227.4% and 431%, respectively. Degradation rates were accelerated, reaching ∼12% weight loss over 60 days, while pH remained in the physiological range (7.2–7.6). Cellular assays revealed enhanced viability on nanoparticle-containing scaffolds, further amplified by over 16% under pulsed magnetic field exposure. SEM and fluorescence imaging confirmed improved cell adhesion and spreading, particularly in the presence of both nanoparticles and magnetic stimulation. These results demonstrate that the synergistic integration of HT and Fe 3 O 4 with external magnetic fields not only optimizes scaffold mechanical properties but also promotes bioactivity, presenting a promising strategy for engineering bone scaffolds with tunable mechanical and biological functionality.

  • Open Access

    Flow-dependent TGF-β1 secretion from HCT116 cells following constriction-based microfluidic passage

    by Mohsen Mashhadi Keshtiban, Fatemeh Asgari, Hanie Kavand, Amirmohammad Sattari, Anna Herland, Saeed Javdansirat, Nooshin Haghighipour, Amin Hadi

  • Open Access

    Piezoelectric PCL/PVDF core-shell nanofibrous scaffolds for enhanced osteogenesis under dynamic loading

    by Golrokh Asadi, Ali Asghar Katbab, Shadab Bagheri-Khoulenjani, Nooshin Haghighipour


  • Electrospun PAN/PANI/CNT scaffolds and electrical pulses: a pathway to stem cell-derived nerve regeneration

    by Zahra Fakhraei Khosravieh, Houra Nekounam, Fatemeh Asgari, Nooshin Haghighipour

    Biocompatible polymer-based scaffolds hold great promise for neural repair, especially when they are coupled with electrostimulation to induce neural differentiation. In this study, a combination of polyacrylonitrile/polyaniline (PAN/PANI) and Carbon Nanotubes (CNTs) were used to fabricate three different biomimetic electrospun scaffolds (samples 1, 2 and 3 containing 0.26 wt%, 1 wt% and 2 wt% of CNTs, respectively). These scaffolds underwent thorough characterization for assessing electroconductivity, tensile strength, wettability, degradability, swelling, XRD, and FTIR data. Notably, scanning electron microscopy (SEM) images revealed a three-dimensional scaffold morphology with aligned fibers ranging from 60 nm to 292 nm in diameter. To comprehensively investigate the impact of electrical stimulation on the nervous differentiation of the stem cells seeded on these scaffolds, cell morphology and adhesion were assessed based on SEM images. Additionally, scaffold biocompatibility was studied through MTT assay. Importantly, Real-Time PCR results indicated the expression of neural markers—Nestin, β-tubulin III, and MAP2—by the cells cultured on these samples. In comparison with the control group, samples 1 and 2 exhibited significant increases in Nestin marker expression, indicating early stages of neuronal differentiation, while β-tubulin III expression was significantly reduced and MAP2 expression remained statistically unchanged. In contrast, sample 3 did not display a statistically significant upturn in Nestin maker expression, while showcasing remarkable increases in the expression of both MAP2 and β-tubulin III, as markers of the end stages of differentiation, leading to postmitotic neurons. These results could be attributed to the higher electroconductivity of S3 compared to other samples. Our findings highlight the biomimetic potential of the prepared scaffolds for neural repair, illustrating their effectiveness in guiding stem cell differentiation toward a neural lineage.


  • The effect of light compressive and tensile mechanical forces on SOST and POSTN expressions in human periodontal ligament cells: an in vitro study

    by Nastaran Sharifi, Mohammad Sadegh Ahmad Akhoundi, Mahshid Hodjat, Nooshin Haghighipour, Setareh Kazemi Veysari

    Periodontal ligament (PDL) cells play an important role in mechanosensing and secretion of signaling molecules during bone remodeling. However, the regulatory mechanism is unknown. The aim of the present study is to investigate the expression pattern of periostin and sclerostin in response to orthodontic forces in periodontal ligament cells in vitro. PDL cells were isolated from extracted teeth and treated with compressive forces of 25 gr/cm2 or equiaxial tension forces at frequency 1 Hz for 0, 24, 48, and 72 h. qRT-PCR was applied to evaluate the gene expressions. The secretion of sclerostin and periostin was assessed using ELISA. DAPI staining was used to evaluate apoptosis. The expression of sclerostin elevated significantly at protein and gene levels under compression forces after 24 h, while the application of tensile forces induced the expression of periostin and its upstream regulator RUNX2 (p < 0.05). Gene expression up-regulation was significant for POSTN and RUNX2 after 48 and 72 h tensile forces. Also, the gene expression of sclerostin reduced in a time-dependent manner after application of tensile force. The compression forces enhanced apoptosis to 7.5 ± 3.5% and induced gene expression of apoptotic markers of CASP9, and BCL2 within 72 h of exposure. Periostin and sclerostin play an important role in orthodontic loads and their expressions are affected oppositely by compressive and tensile forces that might be suggested as a biomarker for assessment of bone remodeling during orthodontic treatment.


  • The Role of Low-Frequency Electromagnetic Fields on Mesenchymal Stem Cells Differentiation: A Systematic Review

    by Atiyeh Sadat Safavi, Anna Sendera, Nooshin Haghighipour, Agnieszka Banas-Zabczyk

    Background Low-frequency electromagnetic fields (EMFs) influence biological processes. This present study was aimed at the scientific literature on the use of EMFs in the mesenchymal stem cell differentiation process. Materials and methods The electronic search was carried out in PubMed and Web of Science, a database with a combination of the sinusoidal and pulsed low- and extremely low-frequency electromagnetic fields stimulation and mesenchymal stem cells differentiation, considering the period of publication until December 2021. The literature search identified 118 references in PubMed and Web of Science of which 46 articles were selected, respectively, according to the eligibility requirements. Conclusion The analysis of research indicated that EMFs are an easy-to-apply and practical way in cell therapy and tissue engineering when regulation of stem cells is required. Studies have shown that EMFs have positive effects on stem cell differentiation, accelerating its process regardless of the parameters and type of stem cells. However, the exact amplitude, frequency, duration of the electrical field, and application method remain elusive and need more study in future work.


  • Open Access

    Replacement of Trypsin by Proteases for Medical Applications

    by Alireza Matinfar, Mehrouz Dezfulian, Nooshin Haghighipour, Mehran Kurdtabar, Ahmad Ali Pourbabaei

    Background: Cell culture has a crucial role in many applications in biotechnology. The production of vaccines, recombinant proteins, tissue engineering, and stem cell therapy all need cell culture. Most of these activities needed adherent cells to move, which should be trypsinized several times until received on a large scale. Although trypsin is manufactured from the bovine or porcine pancreas, the problem of contamination by unwanted animal proteins, unwanted immune reactions, or contamination to pathogen reagents is the main problem. Objectives: This study investigated microbial proteases as a safe alternative for trypsin replacement in cell culture experiments for the detachment of adherent cells. Methods: The bacteria were isolated from the leather industry effluent based on their protease enzymes. After sequencing their 16S ribosomal deoxyribonucleic acid, their protease enzymes were purified, and their enzyme activities were assayed. The alteration of enzymatic activities using different substrates and the effect of substrate concentrations on enzyme activities were determined. The purified proteases were evaluated for cell detachment in the L929 fibroblast cells compared to trypsin. The separated cells were cultured again, and cell proliferation was determined by the MTT assay. Results: The results showed that the isolated bacteria were Bacillus pumilus, Stenotrophomonas sp., Klebsiella aerogenes, Stenotrophomonas maltophilia, and Bacillus licheniformis. Among the isolated bacteria, the highest and the lowest protease activity belonged to Stenotrophomonas sp. and K. aerogenes, with 60.34 and 11.09 U/mL protease activity, respectively. All the isolated microbial proteases successfully affected L929 fibroblast cells’ surface proteins and detached the cells. A significant induction in cell proliferation was observed in the cells treated with K. aerogenes protease and B. pumilus protease, respectively (P < 0.05). Conclusions: The obtained results suggested that microbial proteases can be used as safe and efficient alternatives to trypsin in cell culture in biopharmaceutical applications.


  • In vitro static and dynamic cell culture study of novel bone scaffolds based on 3D-printed PLA and cell-laden alginate hydrogel

    by Reza Noroozi, Mohammad Amin Shamekhi, Reza Mahmoudi, Ali Zolfagharian, Fatemeh Asgari, Ali Mousavizadeh, Mahdi Bodaghi, Amin Hadi, Nooshin Haghighipour

    The aim of this paper was to design and fabricate a novel composite scaffold based on the combination of 3D-printed polylactic acid-based triply periodic minimal surfaces (TPMSs) and cell-laden alginate hydrogel. This novel scaffold improves the low mechanical properties of alginate hydrogel and can also provide a scaffold with a suitable pore size, which can be used in bone regeneration applications. In this regard, an implicit function was used to generate some gyroid TPMS scaffolds. Then the fused deposition modeling process was employed to print the scaffolds. Moreover, the micro computed tomography technique was employed to assess the microstructure of 3D-printed TPMS scaffolds and obtain the real geometries of printed scaffolds. The mechanical properties of composite scaffolds were investigated under compression tests experimentally. It was shown that different mechanical behaviors could be obtained for different implicit function parameters. In this research, to assess the mechanical behavior of printed scaffolds in terms of the strain–stress curves on, two approaches were presented: equivalent volume and finite element-based volume. Results of strain–stress curves showed that the finite-element based approach predicts a higher level of stress. Moreover, the biological response of composite scaffolds in terms of cell viability, cell proliferation, and cell attachment was investigated. In this vein, a dynamic cell culture system was designed and fabricated, which improves mass transport through the composite scaffolds and applies mechanical loading to the cells, which helps cell proliferation. Moreover, the results of the novel composite scaffolds were compared to those without alginate, and it was shown that the composite scaffold could create more viability and cell proliferation in both dynamic and static cultures. Also, it was shown that scaffolds in dynamic cell culture have a better biological response than in static culture. In addition, scanning electron microscopy was employed to study the cell adhesion on the composite scaffolds, which showed excellent attachment between the scaffolds and cells.