Yaroslav I. Korpan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yaroslav I. Korpan has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Alexey P. Soldatkin
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
15 shared publications - Anna V. El'SKaya
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
10 shared publications - Mykhailo Gonchar
Institute of Cell Biology, National Academy of Sciences of Ukraine, 79005 Lviv, Ukraine
10 shared publications Claude Martelet
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 150 Zabolotnogo St., UA-03143, Kyiv-143, Ukraine, Department of Chemistry, Texas A&M University, P.O. Box 30012, College Station, Texas 77842-3012, and Ecole Centrale de Lyon, CEGELY, UMR CNRS 5005, 36 avenue Guy de Collongue, F-69134 Ecully Cedex, France
7 shared publicationsNicole Jaffrezic-Renault
Claude Bernard Lyon 1 University
6 shared publications- Andriy A. Sibirny
Department of Molecular Genetics and Biotechnology, Institute of Cell Biology, NAS of Ukraine, Drahomanov Street, 14/16, Lviv, 79005, Ukraine.
5 shared publications
Latest Publications
- Open Access
- 1 September 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (9) , 867
Electrochemical Biosensors for the Detection of Antibiotics in Milk: Recent Trends and Future Perspectives
Antibiotics have emerged as ground-breaking medications for the treatment of infectious diseases, but due to the excessive use of antibiotics, some drugs have developed resistance to microorganisms. Because of their structural complexity, most antibiotics are excreted unchanged, polluting the water, soil, and natural resources. Additionally, food items are being polluted through the widespread use of antibiotics in animal feed. The normal concentrations of antibiotics in environmental samples typically vary from ng to g/L. Antibiotic residues in excess of these values can pose major risks the development of illnesses and infections/diseases. According to estimates, 300 million people will die prematurely in the next three decades (by 2050), and the WHO has proclaimed “antibiotic resistance” to be a severe economic and sociological hazard to public health. Several antibiotics have been recognised as possible environmental pollutants (EMA) and their detection in various matrices such as food, milk, and environmental samples is being investigated. Currently, chromatographic techniques coupled with different detectors (e.g., HPLC, LC-MS) are typically used for antibiotic analysis. Other screening methods include optical methods, ELISA, electrophoresis, biosensors, etc. To minimise the problems associated with antibiotics (i.e., the development of AMR) and the currently available analytical methods, electrochemical platforms have been investigated, and can provide a cost-effective, rapid and portable alternative. Despite the significant progress in this field, further developments are necessary to advance electrochemical sensors, e.g., through the use of multi-functional nanomaterials and advanced (bio)materials to ensure efficient detection, sensitivity, portability, and reliability. This review summarises the use of electrochemical biosensors for the detection of antibiotics in milk/milk products and presents a brief introduction to antibiotics and AMR followed by developments in the field of electrochemical biosensors based on (i) immunosensor, (ii) aptamer (iii) MIP, (iv) enzyme, (v) whole-cell and (vi) direct electrochemical approaches. The role of nanomaterials and sensor fabrication is discussed wherever necessary. Finally, the review discusses the challenges encountered and future perspectives. This review can serve as an insightful source of information, enhancing the awareness of the role of electrochemical biosensors in providing information for the preservation of the health of the public, of animals, and of our environment, globally.
- 1 September 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (9) , 867
Open AccessElectrochemical Biosensors for the Detection of Antibiotics in Milk: Recent Trends and Future Perspectives
Antibiotics have emerged as ground-breaking medications for the treatment of infectious diseases, but due to the excessive use of antibiotics, some drugs have developed resistance to microorganisms. Because of their structural complexity, most antibiotics are excreted unchanged, polluting the water, soil, and natural resources. Additionally, food items are being polluted through the widespread use of antibiotics in animal feed. The normal concentrations of antibiotics in environmental samples typically vary from ng to g/L. Antibiotic residues in excess of these values can pose major risks the development of illnesses and infections/diseases. According to estimates, 300 million people will die prematurely in the next three decades (by 2050), and the WHO has proclaimed “antibiotic resistance” to be a severe economic and sociological hazard to public health. Several antibiotics have been recognised as possible environmental pollutants (EMA) and their detection in various matrices such as food, milk, and environmental samples is being investigated. Currently, chromatographic techniques coupled with different detectors (e.g., HPLC, LC-MS) are typically used for antibiotic analysis. Other screening methods include optical methods, ELISA, electrophoresis, biosensors, etc. To minimise the problems associated with antibiotics (i.e., the development of AMR) and the currently available analytical methods, electrochemical platforms have been investigated, and can provide a cost-effective, rapid and portable alternative. Despite the significant progress in this field, further developments are necessary to advance electrochemical sensors, e.g., through the use of multi-functional nanomaterials and advanced (bio)materials to ensure efficient detection, sensitivity, portability, and reliability. This review summarises the use of electrochemical biosensors for the detection of antibiotics in milk/milk products and presents a brief introduction to antibiotics and AMR followed by developments in the field of electrochemical biosensors based on (i) immunosensor, (ii) aptamer (iii) MIP, (iv) enzyme, (v) whole-cell and (vi) direct electrochemical approaches. The role of nanomaterials and sensor fabrication is discussed wherever necessary. Finally, the review discusses the challenges encountered and future perspectives. This review can serve as an insightful source of information, enhancing the awareness of the role of electrochemical biosensors in providing information for the preservation of the health of the public, of animals, and of our environment, globally.
- 2 May 2017
- Published by Springer Nature in Microchimica Acta
- Vol. 184 (8) , 2679-2686
Amperometric L-arginine biosensor based on a novel recombinant arginine deiminase
- 2 May 2017
- Published by Springer Nature in Microchimica Acta
- Vol. 184 (8) , 2679-2686
Amperometric L-arginine biosensor based on a novel recombinant arginine deiminase
- 1 March 2017
- Published by Elsevier in Electrochimica Acta
- Vol. 231, 209-215
L-lactate selective impedimetric bienzymatic biosensor based on lactate dehydrogenase and pyruvate oxidase
- 1 March 2017
- Published by Elsevier in Electrochimica Acta
- Vol. 231, 209-215
L-lactate selective impedimetric bienzymatic biosensor based on lactate dehydrogenase and pyruvate oxidase
- 29 March 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (6) , 1981-1987
Direct detection of ammonium ion by means of oxygen electrocatalysis at a copper-polyaniline composite on a screen-printed electrode
- 29 March 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (6) , 1981-1987
Direct detection of ammonium ion by means of oxygen electrocatalysis at a copper-polyaniline composite on a screen-printed electrode
- 1 March 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 77, 505-511
Creatinine and urea biosensors based on a novel ammonium ion-selective copper-polyaniline nano-composite
- 1 March 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 77, 505-511
Creatinine and urea biosensors based on a novel ammonium ion-selective copper-polyaniline nano-composite
- 1 November 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 188, 824-830
Site-binding model as a basis for numerical evaluation of analytical parameters of capacitance-biosensors for formaldehyde and methylamine detection
- 1 November 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 188, 824-830
Site-binding model as a basis for numerical evaluation of analytical parameters of capacitance-biosensors for formaldehyde and methylamine detection
- Open Access
- 20 May 2013
- Published by Institute of Molecular Biology and Genetics (NAS Ukraine) in Biopolymers and Cell
- Vol. 29 (3) , 188-206
Biosensors. A quarter of a century of R&D experience
The paper is a review of the researches of Biomolecular Electronics Laboratory concerning the development of biosensors based on electrochemical transducers (amperometric and conductometric electrodes, potentiometric pH-sensitive field effect transistors) and different biorecognition molecules (enzymes, cells, antibodies), biomimics (molecularly imprinted polymers), as sensitive elements for direct analysis of substrates or inhibitory analysis of toxicants. Highly specific, sensitive, simple, fast and cheap detection of different substances renders them as promising tools for needs of health care, environmental control, biotechnology, agriculture and food industries. Diverse biosensor formats for direct determination of different analytes and inhibitory enzyme analysis of a number of toxins have been designed and developed. Improvement of their analytical characteristics may be achieved by using differential mode of measurement, negatively or positively charged additional semipermeable membranes, nanomaterials of different origin, genetically modified enzymes. These approaches have been aimed at increasing the sensitivity, selectivity and stability of the biosensors and extending their dynamic ranges. During the last 25 years more than 50 laboratory prototypes of biosensor systems based on mono- and multibiosensors for direct determination of a variety of metabolites and inhibitory analysis of different toxic substances were created. Some of them were tested in real samples analysis. The advantages and disadvantages of the biosensors developed are discussed. The possibility of their practical application is considere
- 20 May 2013
- Published by Institute of Molecular Biology and Genetics (NAS Ukraine) in Biopolymers and Cell
- Vol. 29 (3) , 188-206
Open AccessBiosensors. A quarter of a century of R&D experience
The paper is a review of the researches of Biomolecular Electronics Laboratory concerning the development of biosensors based on electrochemical transducers (amperometric and conductometric electrodes, potentiometric pH-sensitive field effect transistors) and different biorecognition molecules (enzymes, cells, antibodies), biomimics (molecularly imprinted polymers), as sensitive elements for direct analysis of substrates or inhibitory analysis of toxicants. Highly specific, sensitive, simple, fast and cheap detection of different substances renders them as promising tools for needs of health care, environmental control, biotechnology, agriculture and food industries. Diverse biosensor formats for direct determination of different analytes and inhibitory enzyme analysis of a number of toxins have been designed and developed. Improvement of their analytical characteristics may be achieved by using differential mode of measurement, negatively or positively charged additional semipermeable membranes, nanomaterials of different origin, genetically modified enzymes. These approaches have been aimed at increasing the sensitivity, selectivity and stability of the biosensors and extending their dynamic ranges. During the last 25 years more than 50 laboratory prototypes of biosensor systems based on mono- and multibiosensors for direct determination of a variety of metabolites and inhibitory analysis of different toxic substances were created. Some of them were tested in real samples analysis. The advantages and disadvantages of the biosensors developed are discussed. The possibility of their practical application is considere
- 1 December 2011
- Published by American Scientific Publishers in Sensor Letters
- Vol. 9 (6) , 2388-2391
Conductometric Biosensor Based on Flavocytochrome b2 for L-Lactate Determination
- 1 December 2011
- Published by American Scientific Publishers in Sensor Letters
- Vol. 9 (6) , 2388-2391
Conductometric Biosensor Based on Flavocytochrome b2 for L-Lactate Determination
- 1 December 2011
- Published by American Scientific Publishers in Sensor Letters
- Vol. 9 (6) , 2356-2359
Glucose Biosensor Based on Screen-Printed Electrodes and Glucose Oxidase Layer Modified by MWCNT-NH2
- 1 December 2011
- Published by American Scientific Publishers in Sensor Letters
- Vol. 9 (6) , 2356-2359
Glucose Biosensor Based on Screen-Printed Electrodes and Glucose Oxidase Layer Modified by MWCNT-NH2
- Open Access
- 1 April 2011
- Published by IntechOpen
Formaldehyde Oxidizing Enzymes and Genetically Modified Yeast Hansenula polymorpha Cells in Monitoring and Removal of Formaldehyde
Formaldehyde Oxidizing Enzymes and Genetically Modified Yeast Hansenula polymorpha Cells in Monitoring and Removal of Formaldehyde | InTechOpen, Published on: 2011-04-01. Authors: Vladimir Sibirny, Olha Demkiv, Sasi Sigawi, et
- 1 April 2011
- Published by IntechOpen
Open AccessFormaldehyde Oxidizing Enzymes and Genetically Modified Yeast Hansenula polymorpha Cells in Monitoring and Removal of Formaldehyde
Formaldehyde Oxidizing Enzymes and Genetically Modified Yeast Hansenula polymorpha Cells in Monitoring and Removal of Formaldehyde | InTechOpen, Published on: 2011-04-01. Authors: Vladimir Sibirny, Olha Demkiv, Sasi Sigawi, et