John E. McManigle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
John E. McManigle has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Julia Alison Noble
Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
4 shared publications - Mohammad Yaqub
Mohamed bin Zayed University of Artificial Intelligence
2 shared publications Richard V. Stebbing
Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, U.K.
2 shared publicationsA. I. Guttentag
California NanoSystems Institute, UCLA, Los Angeles, USA
1 shared publicationA. L. Gibb
Center for Nanoscale Science, The Pennsylvania State University, University Park, USA
1 shared publicationA. Vaish
Center for Nanoscale Science, The Pennsylvania State University, University Park, USA
1 shared publication
Latest Publications
- 5 May 2022
- Published by S. Karger AG in Pediatric Neurosurgery
- Vol. 57 (4) , 295-300
Successful Neonatal, Intraoperative Neuromonitoring in the Surgical Correction of a Thoracic Dermal Sinus Tract: Technical Note
Introduction: Intraoperative neuromonitoring (IONM) is commonly used during surgery of the spine and spinal cord for early surveillance of iatrogenic injury to the central and peripheral nervous system. However, for infants and young children under 3 years of age, the use of IONM is challenging due to incomplete central and peripheral myelination. Case presentation: We report a case of a T4-T6 DST that was resected on day of life 23 with the successful use of IONM. Conclusion: To our knowledge, this is the youngest reported case of the use of IONM in the surgical correction of a DST in a neonatal patient. This case demonstrates the potential efficacy of IONM in neonatal spine surgery and the techniques used to adapt the technology to an immature nervous system.
- 5 May 2022
- Published by S. Karger AG in Pediatric Neurosurgery
- Vol. 57 (4) , 295-300
Successful Neonatal, Intraoperative Neuromonitoring in the Surgical Correction of a Thoracic Dermal Sinus Tract: Technical Note
Introduction: Intraoperative neuromonitoring (IONM) is commonly used during surgery of the spine and spinal cord for early surveillance of iatrogenic injury to the central and peripheral nervous system. However, for infants and young children under 3 years of age, the use of IONM is challenging due to incomplete central and peripheral myelination. Case presentation: We report a case of a T4-T6 DST that was resected on day of life 23 with the successful use of IONM. Conclusion: To our knowledge, this is the youngest reported case of the use of IONM in the surgical correction of a DST in a neonatal patient. This case demonstrates the potential efficacy of IONM in neonatal spine surgery and the techniques used to adapt the technology to an immature nervous system.
- Open Access
- 6 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 33 (4) , 797-813
Evaluation and Comparison of Current Fetal Ultrasound Image Segmentation Methods for Biometric Measurements: A Grand Challenge
This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.
- 6 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 33 (4) , 797-813
Open AccessEvaluation and Comparison of Current Fetal Ultrasound Image Segmentation Methods for Biometric Measurements: A Grand Challenge
This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.
- Open Access
- 1 September 2012
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 177 (9S) , 68-71
Where are They Now? USU School of Medicine Graduates After Their Military Obligation is Complete
The Uniformed Services University’s (USU) F. Edward Hébert School of Medicine was chartered in 1972, with the goal of providing high-quality physicians for the Uniformed Services. In exchange for their education, USU graduates incur an active duty service obligation, after which they may choose to stay on active duty or transition to civilian practice. The purpose of this study is to describe the practice characteristics of USU graduates after this obligation has been completed in order to determine the societal benefits during this phase of their careers. To accomplish this purpose, we performed a retrospective cohort study of the first 20 years of USU graduates (1980–1999). We used the American Medical Association Physician Masterfile to determine the graduates’ current practice location and characteristics, as well as their board certification status. Of these 2,760 graduates, nearly all (91%) were involved in active clinical practice in over 100 self-declared specialties, the vast majority (89%) practiced in locations other than the immediate vicinity of the medical school (i.e., Maryland and the District of Columbia), and most still worked for the federal government (71%). Finally, USU graduates in full-time clinical practice had a board certification rate of 93%, which was better than the average of all other graduates of U.S. Medical Schools (88%) in the same time period. Thus, it seems USU is attaining its goal of producing high-quality physicians who continue to benefit the nation after their service obligation has been completed, with many still in federal service.
- 1 September 2012
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 177 (9S) , 68-71
Open AccessWhere are They Now? USU School of Medicine Graduates After Their Military Obligation is Complete
The Uniformed Services University’s (USU) F. Edward Hébert School of Medicine was chartered in 1972, with the goal of providing high-quality physicians for the Uniformed Services. In exchange for their education, USU graduates incur an active duty service obligation, after which they may choose to stay on active duty or transition to civilian practice. The purpose of this study is to describe the practice characteristics of USU graduates after this obligation has been completed in order to determine the societal benefits during this phase of their careers. To accomplish this purpose, we performed a retrospective cohort study of the first 20 years of USU graduates (1980–1999). We used the American Medical Association Physician Masterfile to determine the graduates’ current practice location and characteristics, as well as their board certification status. Of these 2,760 graduates, nearly all (91%) were involved in active clinical practice in over 100 self-declared specialties, the vast majority (89%) practiced in locations other than the immediate vicinity of the medical school (i.e., Maryland and the District of Columbia), and most still worked for the federal government (71%). Finally, USU graduates in full-time clinical practice had a board certification rate of 93%, which was better than the average of all other graduates of U.S. Medical Schools (88%) in the same time period. Thus, it seems USU is attaining its goal of producing high-quality physicians who continue to benefit the nation after their service obligation has been completed, with many still in federal service.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 290-293
Modified Hough transform for left ventricle myocardium segmentation in 3-D echocardiogram images
Segmentation of the left ventricular myocardium from 3D echocardiograms is complicated by speckle, artifact, and complex anatomy. Typical segmentation methods benefit from accurate initialization. We propose a two-step Hough transform to find an annular approximation of the myocardium in short-axis echo slices. The method was compared to manual segmentation of 5641 slices by center points and endocardial and epicardial radii. Centers deviated by a mean 3.31 mm, and radii by 2.57 mm and 3.04 mm, respectively. Dice's coefficient of similarity was 0.70. Similarity is higher when apical slices are ignored. 93.8% of all slices and 96.8% of non-apical slices met criteria that suggest they would be appropriate to initialize further segmentation.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 290-293
Modified Hough transform for left ventricle myocardium segmentation in 3-D echocardiogram images
Segmentation of the left ventricular myocardium from 3D echocardiograms is complicated by speckle, artifact, and complex anatomy. Typical segmentation methods benefit from accurate initialization. We propose a two-step Hough transform to find an annular approximation of the myocardium in short-axis echo slices. The method was compared to manual segmentation of 5641 slices by center points and endocardial and epicardial radii. Centers deviated by a mean 3.31 mm, and radii by 2.57 mm and 3.04 mm, respectively. Dice's coefficient of similarity was 0.70. Similarity is higher when apical slices are ignored. 93.8% of all slices and 96.8% of non-apical slices met criteria that suggest they would be appropriate to initialize further segmentation.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 238-241
Interpreting edge information for improved endocardium delineation in echocardiograms
Successful segmentation of the left ventricle in echocardiograms relies on strong edge responses to ensure that segmentation methods converge to the endocardial boundary. However, segmentation methods that do not interpret edge responses using local shape information or global context are often led astray by imaging artifacts. An extension to a boundary fragment model borrowed from computer vision literature is presented as a method for determining which edge responses contribute to the endocardial boundary. To demonstrate its applicability, the proposed method is applied to a data set composed of long-axis echocardiogram slices from five subjects. Results show that the process is effective at locating the endocardium and identifying the edge responses which correspond to the endocardial boundary.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 238-241
Interpreting edge information for improved endocardium delineation in echocardiograms
Successful segmentation of the left ventricle in echocardiograms relies on strong edge responses to ensure that segmentation methods converge to the endocardial boundary. However, segmentation methods that do not interpret edge responses using local shape information or global context are often led astray by imaging artifacts. An extension to a boundary fragment model borrowed from computer vision literature is presented as a method for determining which edge responses contribute to the endocardial boundary. To demonstrate its applicability, the proposed method is applied to a data set composed of long-axis echocardiogram slices from five subjects. Results show that the process is effective at locating the endocardium and identifying the edge responses which correspond to the endocardial boundary.
- 26 August 2011
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 47 (38) , 10641-10643
Patterning small-molecule biocapture surfaces: microcontact insertion printing vs. photolithography
Chemical patterns prepared by self-assembly, combined with soft lithography or photolithography, are directly compared. Pattern fidelity can be controlled in both cases but patterning at the low densities necessary for small-molecule probe capture of large biomolecule targets is better accomplished using microcontact insertion printing (μCIP). Surfaces patterned by μCIP are used to capture biomolecule binding partners for the small molecules dopamine and biotin.
- 26 August 2011
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 47 (38) , 10641-10643
Patterning small-molecule biocapture surfaces: microcontact insertion printing vs. photolithography
Chemical patterns prepared by self-assembly, combined with soft lithography or photolithography, are directly compared. Pattern fidelity can be controlled in both cases but patterning at the low densities necessary for small-molecule probe capture of large biomolecule targets is better accomplished using microcontact insertion printing (μCIP). Surfaces patterned by μCIP are used to capture biomolecule binding partners for the small molecules dopamine and biotin.