Peter Bako
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter Bako has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Adrienn Nemeth
Department of Oto-Rhino-Laryngology and Head-Neck Surgery, University of Pécs, 7621 Pécs, Hungary
2 shared publications - Zalán Piski
University of Pécs, Department of Otorhinolaryngology, Pécs, 7621, Munkácsy M Str 2, Hungary
2 shared publications - Andras Burian
University of Pécs, Department of Otorhinolaryngology, Pécs, 7621, Munkácsy M Str 2, Hungary
1 shared publication - Andras Burian
Department of Otorhinolaryngology, Head and Neck Surgery, Medical School, University of Pécs, Pécs, Hungary
1 shared publication - Arnold Tóth
Department of Medical Imaging, Medical School, University of Pecs, Pecs, Hungary
1 shared publication - Gabor Rath
Department of Pediatrics, University of Pécs, Hungary Pécs, Hungary
1 shared publication
Latest Publications
- Open Access
- 10 October 2022
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 26 (4) , 214-222
Subtotal Petrosectomy and Cochlear Implantation in Children With Chronic Suppurative Otitis Media: A Single Institutional Experience
Background and Objectives: Chronic suppurative otitis media (CSOM) with or without cholesteatoma is a frequent chronic inflammatory condition in children, which may lead to severe hearing loss that affects speech development. Treatment of recurrent CSOM associated with unserviceable hearing requires a specialized approach with regard to disease eradication and hearing rehabilitation. In this study, we investigated the advantages of subtotal petrosectomy (SP) combined with cochlear implantation (CI) in children with CSOM associated with unserviceable hearing and describe our experience with regard to the efficacy of this method, together with a literature review.Subjects and Methods: SP with sequential or simultaneous CI was performed in three children (four ears), and postoperative audiometric data were recorded.Results: The study included two male and one female patient. Mean age at the time of SP was 10.75 years (7–13 years). Sequential implantation was performed in three ears. Facial nerve palsy occurred after SP in one patient. The latest word recognition scores of Cases 1, 2, and 3 were 80% (at 60 dB), 75% (at 60 dB), and 70% (at 50 dB) and 90% (at 50 dB), respectively.Conclusions: SP with CI may be safe and reliable in children with CSOM associated with unserviceable hearing.
- 10 October 2022
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 26 (4) , 214-222
Open AccessSubtotal Petrosectomy and Cochlear Implantation in Children With Chronic Suppurative Otitis Media: A Single Institutional Experience
Background and Objectives: Chronic suppurative otitis media (CSOM) with or without cholesteatoma is a frequent chronic inflammatory condition in children, which may lead to severe hearing loss that affects speech development. Treatment of recurrent CSOM associated with unserviceable hearing requires a specialized approach with regard to disease eradication and hearing rehabilitation. In this study, we investigated the advantages of subtotal petrosectomy (SP) combined with cochlear implantation (CI) in children with CSOM associated with unserviceable hearing and describe our experience with regard to the efficacy of this method, together with a literature review.Subjects and Methods: SP with sequential or simultaneous CI was performed in three children (four ears), and postoperative audiometric data were recorded.Results: The study included two male and one female patient. Mean age at the time of SP was 10.75 years (7–13 years). Sequential implantation was performed in three ears. Facial nerve palsy occurred after SP in one patient. The latest word recognition scores of Cases 1, 2, and 3 were 80% (at 60 dB), 75% (at 60 dB), and 70% (at 50 dB) and 90% (at 50 dB), respectively.Conclusions: SP with CI may be safe and reliable in children with CSOM associated with unserviceable hearing.
- Open Access
- 17 February 2022
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 372, 109527
The ototoxic effect of locally applied kanamycin and furosemide in guinea pigs
- 17 February 2022
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 372, 109527
Open AccessThe ototoxic effect of locally applied kanamycin and furosemide in guinea pigs
- 28 November 2018
- Published by Wolters Kluwer Health in Hearing Balance and Communication
- Vol. 16 (4) , 232-237
Cochlear implantation in patients afflicted with inner ear malformations – the Pécs experience
Purpose: To successfully analyze the surgical and audiological results of cochlear implantation in patients afflicted with inner ear malformations. This study briefly presents our surgical strategies, the selected implants and the audiological results. Method: Objective hearing threshold was measured using an auditory brainstem response and middle latency response audiometry. Structural imaging of high resolution temporal bone computer tomography and inner ear MR scan was performed in support of all patients. Images revealed bilateral cochlear malformation in seven patients. Three ears with common cavity deformity, two ears with incomplete partition type I and three ears suffering from cochlear hypoplasia were all rehabilitated using cochlear implantation. The type of the electrode and the surgical technique were individually determined reflective of the type of malformation. The success of the surgery and potential postoperative complications were duly noted and fully registered. Postoperative audiological measurements were performed and the results were analyzed. Results: The average audiological follow-up was 40.3 months. The average free field, pure-tone threshold of speech frequencies (0.5–3 kHz) gained postoperatively were within the range of 32.5–41.6 dB. In two of the procedures, a cerebrospinal fluid gusher did occur and was successfully managed intraoperatively, all without any postoperative complications. Conclusion: Temporal bone high resolution CT and inner ear MRI imaging are mandatory to detect and characterize the inner ear malformation. Early implantation of malformed cochlea is crucial towards achieving ideal postoperative audiological results. Notably, an intraoperative gusher is not regarded as a contraindication of the cochlear implantation.
- 28 November 2018
- Published by Wolters Kluwer Health in Hearing Balance and Communication
- Vol. 16 (4) , 232-237
Cochlear implantation in patients afflicted with inner ear malformations – the Pécs experience
Purpose: To successfully analyze the surgical and audiological results of cochlear implantation in patients afflicted with inner ear malformations. This study briefly presents our surgical strategies, the selected implants and the audiological results. Method: Objective hearing threshold was measured using an auditory brainstem response and middle latency response audiometry. Structural imaging of high resolution temporal bone computer tomography and inner ear MR scan was performed in support of all patients. Images revealed bilateral cochlear malformation in seven patients. Three ears with common cavity deformity, two ears with incomplete partition type I and three ears suffering from cochlear hypoplasia were all rehabilitated using cochlear implantation. The type of the electrode and the surgical technique were individually determined reflective of the type of malformation. The success of the surgery and potential postoperative complications were duly noted and fully registered. Postoperative audiological measurements were performed and the results were analyzed. Results: The average audiological follow-up was 40.3 months. The average free field, pure-tone threshold of speech frequencies (0.5–3 kHz) gained postoperatively were within the range of 32.5–41.6 dB. In two of the procedures, a cerebrospinal fluid gusher did occur and was successfully managed intraoperatively, all without any postoperative complications. Conclusion: Temporal bone high resolution CT and inner ear MRI imaging are mandatory to detect and characterize the inner ear malformation. Early implantation of malformed cochlea is crucial towards achieving ideal postoperative audiological results. Notably, an intraoperative gusher is not regarded as a contraindication of the cochlear implantation.
- 20 November 2013
- Published by Springer Nature
- Vol. 271 (12) , 3171-3177
KTP laser stapedotomy with a self-crimping, thermal shape memory Nitinol piston: follow-up study reporting intermediate-term hearing
The aim of this study was an evaluation of the mid-term hearing results after the implantation of a self-crimping heat memory Nitinol piston in stapes surgery. The 12-month postoperative results were compared with those at a minimum of 3 years (maximum 6.7, average 4.4 years). The medical records of all 44 patients who underwent surgery with a Nitinol piston for stapes fixation between November 2005 and January 2007 were evaluated retrospectively. The prostheses used in all cases measured either 4.5 or 4.75 × 0.6 mm. We hypothesized that the 12-month postoperative hearing results would be permanent after an average follow-up of 4.4 years. Thirty-two of the 44 consecutive patients were females and 12 were males. Their mean age was 40.4 years (range 27–69). All underwent a 12-month postoperative audiometric evaluation. 38 (30 females, 8 males, average age 45, range 28–77 years) of the 44 were available for mid-term 4.4-year (minimum 3 years, maximum 6.7 years) postoperative audiometric evaluation. The mean air–bone gap (ABG) for the frequencies 0.5, 1, 2 and 3 kHz at the 12-month postoperative follow-up was 11 dB (SD 4.1) and that after an average 4.4-year postoperative evaluation was 6.4 dB (SD 3.6). The mean decrease in ABG after 12 months was 19.5 dB, and that after the average 4.4 years was 21.3 dB. ABG closure within 10 dB was achieved in 77.2 % after 12 months and in 89.5 % after the average 4.4 years. No patient with an ABG > 20 dB was recorded after the average 4.4 years. The mean air conduction threshold at 4 kHz was examined pre and postoperatively so as to indicate any possible inner ear damage. At the 12-month follow-up, the difference between the pre and postoperative values was −2.5 dB, whereas after the average 4.4 years the difference was surprisingly +13 dB. The individual AC improvements were also demonstrated with the use of Amsterdam Hearing Evaluation Plots (AHEPs). The Nitinol prosthesis allowed excellent intraoperative handling and no postoperative complication was reported. As compared with conventional stapes prostheses, the Nitinol-based SMart prosthesis is a safe and reliable stapes prosthesis. Our mid-term audiometric evaluations revealed that the audiometric parameters demonstrated a hearing improvement between the postoperative 12-month and average 4.4-year examinations. We consider the elimination of manual crimping and the use of a “non-touch” hand-held laser technique has a positive impact on the mid-term audiometric results. Most of the previous studies presented only relatively short-term (from 6 weeks up to 6–12 months) audiometric evaluations. Complications are rare, but a longer follow-up is needed to establish the long-term stability.
- 20 November 2013
- Published by Springer Nature
- Vol. 271 (12) , 3171-3177
KTP laser stapedotomy with a self-crimping, thermal shape memory Nitinol piston: follow-up study reporting intermediate-term hearing
The aim of this study was an evaluation of the mid-term hearing results after the implantation of a self-crimping heat memory Nitinol piston in stapes surgery. The 12-month postoperative results were compared with those at a minimum of 3 years (maximum 6.7, average 4.4 years). The medical records of all 44 patients who underwent surgery with a Nitinol piston for stapes fixation between November 2005 and January 2007 were evaluated retrospectively. The prostheses used in all cases measured either 4.5 or 4.75 × 0.6 mm. We hypothesized that the 12-month postoperative hearing results would be permanent after an average follow-up of 4.4 years. Thirty-two of the 44 consecutive patients were females and 12 were males. Their mean age was 40.4 years (range 27–69). All underwent a 12-month postoperative audiometric evaluation. 38 (30 females, 8 males, average age 45, range 28–77 years) of the 44 were available for mid-term 4.4-year (minimum 3 years, maximum 6.7 years) postoperative audiometric evaluation. The mean air–bone gap (ABG) for the frequencies 0.5, 1, 2 and 3 kHz at the 12-month postoperative follow-up was 11 dB (SD 4.1) and that after an average 4.4-year postoperative evaluation was 6.4 dB (SD 3.6). The mean decrease in ABG after 12 months was 19.5 dB, and that after the average 4.4 years was 21.3 dB. ABG closure within 10 dB was achieved in 77.2 % after 12 months and in 89.5 % after the average 4.4 years. No patient with an ABG > 20 dB was recorded after the average 4.4 years. The mean air conduction threshold at 4 kHz was examined pre and postoperatively so as to indicate any possible inner ear damage. At the 12-month follow-up, the difference between the pre and postoperative values was −2.5 dB, whereas after the average 4.4 years the difference was surprisingly +13 dB. The individual AC improvements were also demonstrated with the use of Amsterdam Hearing Evaluation Plots (AHEPs). The Nitinol prosthesis allowed excellent intraoperative handling and no postoperative complication was reported. As compared with conventional stapes prostheses, the Nitinol-based SMart prosthesis is a safe and reliable stapes prosthesis. Our mid-term audiometric evaluations revealed that the audiometric parameters demonstrated a hearing improvement between the postoperative 12-month and average 4.4-year examinations. We consider the elimination of manual crimping and the use of a “non-touch” hand-held laser technique has a positive impact on the mid-term audiometric results. Most of the previous studies presented only relatively short-term (from 6 weeks up to 6–12 months) audiometric evaluations. Complications are rare, but a longer follow-up is needed to establish the long-term stability.