Tatsuo Nozokido
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tatsuo Nozokido has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Jongsuck Bae
Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya, Aichi, 466-8555, Japan
25 shared publications K. Mizuno
Research Institute of Electrical Communication, Tohoku University, 2-1-1, Katahira, Aoba-ku, Sendai, Miyagi 980-8577, Japan
14 shared publicationsKoji Mizuno
The authors are with the Faculty of Systems Science and Thecnology, Akita Prefectural University; Tsuchiya Ebinokuchi 84-4, Honjyo 015-0055, Japan, and the Research Institute of Electrical Communication, Tohoku University, Aoba-ku Katahira 2-1-1, Sendai 980-8577, Japan
14 shared publicationsK. Furuya
7 shared publications- Manabu Ishino
Graduate School of Science and Engineering for Research, University of Toyama, Japan
7 shared publications H. Shirai
6 shared publications
Latest Publications
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (21) , 25927-25937
Highly Sensitive Sensing of Refractive Index Using Surface Lattice Resonance in Capacitive Metal Meshes at Millimeter Wave Frequencies
We propose the use of surface lattice resonance (SLR) in capacitive metal meshes (CMMs) to permit highly sensitive measurement of the refractive index in the millimeter wave (MMW) range. CMMs, which comprise two-dimensional periodic arrays of square metal patches on thin quartz substrates, are one of the simplest and most classical metasurfaces. Experiments and numerical simulations performed at frequencies around 0.1 THz show that SLRs in such CMMs have extraordinarily high unloaded Q -factors of greater than 1000, when the ratio of the length of the metal patch to the mesh period of the CMM and the thickness of the quartz substrate are optimized. An intense and sharp dip in transmission in excess of -60 dB at the SLR frequency with this high unloaded Q -factor was produced in a CMM. Using a CMM as a refractive index sensor, a figure of merit of greater than 340 for frequency interrogation and a refractive index resolution of better than 1.9×10 -6 refractive index units for phase interrogation were experimentally demonstrated. These results indicate that CMMs are superior sensors with high performance in the MMW region.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (21) , 25927-25937
Highly Sensitive Sensing of Refractive Index Using Surface Lattice Resonance in Capacitive Metal Meshes at Millimeter Wave Frequencies
We propose the use of surface lattice resonance (SLR) in capacitive metal meshes (CMMs) to permit highly sensitive measurement of the refractive index in the millimeter wave (MMW) range. CMMs, which comprise two-dimensional periodic arrays of square metal patches on thin quartz substrates, are one of the simplest and most classical metasurfaces. Experiments and numerical simulations performed at frequencies around 0.1 THz show that SLRs in such CMMs have extraordinarily high unloaded Q -factors of greater than 1000, when the ratio of the length of the metal patch to the mesh period of the CMM and the thickness of the quartz substrate are optimized. An intense and sharp dip in transmission in excess of -60 dB at the SLR frequency with this high unloaded Q -factor was produced in a CMM. Using a CMM as a refractive index sensor, a figure of merit of greater than 340 for frequency interrogation and a refractive index resolution of better than 1.9×10 -6 refractive index units for phase interrogation were experimentally demonstrated. These results indicate that CMMs are superior sensors with high performance in the MMW region.
- Open Access
- 20 March 2023
- Published by Springer Nature in Research Square
Surface Lattice Resonance with an Ultra-High Unloaded Q-Factor in Capacitive Metal Meshes at Terahertz Frequencies
We investigated the surface lattice resonance (SLR) occurring in capacitive metal meshes (CMMs) in the terahertz (THz) range. CMMs, which comprise two-dimensional periodic arrays of square metal patches on thin quartz substrates, are one of the simplest metasurfaces. Experiments and theoretical simulations performed at frequencies around 0.1 THz show that the SLR in such CMMs has an extraordinarily high unloaded Q-factor of greater than 1000, when the ratio of the length of the metal patch to the mesh period of the CMM and the thickness of the quartz substrate are optimized. An intense and sharp dip in transmission in excess of -60 dB at the SLR frequency was produced with this high unloaded Q-factor in the CMM. Using the CMM as a refractive index sensor, a figure of merit of greater than 340 for frequency interrogation and a refractive index resolution of better than 1.9×10− 6 refractive index units for phase interrogation were experimentally demonstrated. These results indicate that CMMs are superior sensors with high performance in the THz-wave region.
- 20 March 2023
- Published by Springer Nature in Research Square
Open AccessSurface Lattice Resonance with an Ultra-High Unloaded Q-Factor in Capacitive Metal Meshes at Terahertz Frequencies
We investigated the surface lattice resonance (SLR) occurring in capacitive metal meshes (CMMs) in the terahertz (THz) range. CMMs, which comprise two-dimensional periodic arrays of square metal patches on thin quartz substrates, are one of the simplest metasurfaces. Experiments and theoretical simulations performed at frequencies around 0.1 THz show that the SLR in such CMMs has an extraordinarily high unloaded Q-factor of greater than 1000, when the ratio of the length of the metal patch to the mesh period of the CMM and the thickness of the quartz substrate are optimized. An intense and sharp dip in transmission in excess of -60 dB at the SLR frequency was produced with this high unloaded Q-factor in the CMM. Using the CMM as a refractive index sensor, a figure of merit of greater than 340 for frequency interrogation and a refractive index resolution of better than 1.9×10− 6 refractive index units for phase interrogation were experimentally demonstrated. These results indicate that CMMs are superior sensors with high performance in the THz-wave region.
- 26 February 2021
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 42 (4) , 416-425
Sensitive Near-Field Slit Probe with High Spatial Resolution for Passive Millimeter-Wave Microscopy
- 26 February 2021
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 42 (4) , 416-425
Sensitive Near-Field Slit Probe with High Spatial Resolution for Passive Millimeter-Wave Microscopy
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. j83 d ii, 1-2
Compressed Sensing Image Reconstruction For Millimeter-Wave Near-Field Scanning Microscopy Using a Metal Slit Probe
We report on the use of a compressed sensing technique for two-dimensional image reconstruction in millimeter-wave near-field scanning microscopy that enables the measurement time required to acquire the projection data sets to be reduced. Experiments performed at 60 GHz to image the electrical response anisotropy of the sample using compressed sensing image reconstruction show that just 1/8th of the full scan data needs to be measured to allow perfect image reconstruction.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. j83 d ii, 1-2
Compressed Sensing Image Reconstruction For Millimeter-Wave Near-Field Scanning Microscopy Using a Metal Slit Probe
We report on the use of a compressed sensing technique for two-dimensional image reconstruction in millimeter-wave near-field scanning microscopy that enables the measurement time required to acquire the projection data sets to be reduced. Experiments performed at 60 GHz to image the electrical response anisotropy of the sample using compressed sensing image reconstruction show that just 1/8th of the full scan data needs to be measured to allow perfect image reconstruction.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Passive millimeter-wave microscopy of aqueous protein solutions at low temperatures
Thermal radiation emitted from aqueous solutions of bovine serum albumin (BSA), which is a serum albumin protein derived from cows, was measured and analyzed by passive millimeter-wave microscopy at temperatures below the freezing point of water. The thermal radiation emitted from 0.9 ml BSA aqueous solutions with different concentrations was measured at 50 GHz and temperatures ranging from 130 K to 260 K. Two different conformational states of the BSA were observed. The emissivities of the BSA solutions were successfully determined from the measured results. Imaging of small $1.0 \mu \mathrm{l}$ volumes of allayed BSA aqueous solutions was carried out at 230 K.- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Passive millimeter-wave microscopy of aqueous protein solutions at low temperatures
Thermal radiation emitted from aqueous solutions of bovine serum albumin (BSA), which is a serum albumin protein derived from cows, was measured and analyzed by passive millimeter-wave microscopy at temperatures below the freezing point of water. The thermal radiation emitted from 0.9 ml BSA aqueous solutions with different concentrations was measured at 50 GHz and temperatures ranging from 130 K to 260 K. Two different conformational states of the BSA were observed. The emissivities of the BSA solutions were successfully determined from the measured results. Imaging of small $1.0 \mu \mathrm{l}$ volumes of allayed BSA aqueous solutions was carried out at 230 K.- 2 April 2019
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 40 (5) , 585-594
Observation of Protein Thermodynamics in Ice by Passive Millimeter-Wave Microscopy
- 2 April 2019
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 40 (5) , 585-594
Observation of Protein Thermodynamics in Ice by Passive Millimeter-Wave Microscopy
- Open Access
Observation of protein thermodynamics in ice by passive millimeter-wave microscopy
The study of protein functions attributed to the conformation and fluctuation that are ruled by both the amino acid sequence and thermodynamics, requires thermodynamic quantities given by calorimetry using thermometric techniques. The increased need for protein function in different applications requires improvements of measurement systems assessing protein thermodynamics to handle many kinds of samples quickly. We have developed a passive millimeter-wave microscope that allows near-field imaging of thermal radiation, even in the low temperature range under room temperature where passive infrared imaging systems are ineffective. This advantage of our microscope system in combination with low thermal emission property of water ice in the millimeter-wave region enables the characterization of the thermal radiation from the proteins themselves in aqueous solution at a temperature range low enough to freeze water and to trap conformation intermediates in the proteins. Experiments performed at a millimeter-wave frequency of 50 GHz in a temperature range from 130 K to 270 K for a 20 % bovine serum albumin (BSA) aqueous solution showed a displacement between two conformational states of BSA at a temperature of approximately 190 K as a boundary. Our microscope system using this freeze-trapping method is expected to provide noninvasive thermal images to enable novel high-throughput calorimetry useful for the analysis of protein functions.
Open AccessObservation of protein thermodynamics in ice by passive millimeter-wave microscopy
The study of protein functions attributed to the conformation and fluctuation that are ruled by both the amino acid sequence and thermodynamics, requires thermodynamic quantities given by calorimetry using thermometric techniques. The increased need for protein function in different applications requires improvements of measurement systems assessing protein thermodynamics to handle many kinds of samples quickly. We have developed a passive millimeter-wave microscope that allows near-field imaging of thermal radiation, even in the low temperature range under room temperature where passive infrared imaging systems are ineffective. This advantage of our microscope system in combination with low thermal emission property of water ice in the millimeter-wave region enables the characterization of the thermal radiation from the proteins themselves in aqueous solution at a temperature range low enough to freeze water and to trap conformation intermediates in the proteins. Experiments performed at a millimeter-wave frequency of 50 GHz in a temperature range from 130 K to 270 K for a 20 % bovine serum albumin (BSA) aqueous solution showed a displacement between two conformational states of BSA at a temperature of approximately 190 K as a boundary. Our microscope system using this freeze-trapping method is expected to provide noninvasive thermal images to enable novel high-throughput calorimetry useful for the analysis of protein functions.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Dual-Polarization Imaging with Real-Time Capability Using a Terahertz Noise Source for Food Inspection
A dual-polarization terahertz imaging system using a noise source which has frequency components between 0.075 THz and 0.11 THz has been newly developed for food inspection. The imaging system can take horizontal and vertical polarization images independently and simultaneously with a spatial resolution of better than 4 mm and a high data acquisition speed of 10 lines data (1,200 pixels) /msec. These characteristics of the imaging system fulfill industrial requirements for inspection of foods conveyed at a velocity of higher than 20 m/min.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Dual-Polarization Imaging with Real-Time Capability Using a Terahertz Noise Source for Food Inspection
A dual-polarization terahertz imaging system using a noise source which has frequency components between 0.075 THz and 0.11 THz has been newly developed for food inspection. The imaging system can take horizontal and vertical polarization images independently and simultaneously with a spatial resolution of better than 4 mm and a high data acquisition speed of 10 lines data (1,200 pixels) /msec. These characteristics of the imaging system fulfill industrial requirements for inspection of foods conveyed at a velocity of higher than 20 m/min.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Measurement of Protein Conformational Fluctuation in Ice by Passive Millimeter-Wave Microscopy
Thermal radiation emitted from an aqueous solution of bovine serum albumin (BSA) was measured and analyzed by passive millimeter-wave microscopy at a temperature range low enough to freeze water and to trap conformational intermediates in BSA. Experiments were performed at a millimeter-wave frequency of 50 GHz in a temperature range from 130 K to 270 K for a 20 % BSA aqueous solution, showing a displacement between two conformational states of BSA at a boundary temperature of approximately 190 K. Our microscope system using this freeze-trapping method is expected to provide noninvasive thermal images to enable novel high-throughput calorimetry useful for the analysis of protein functions.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Measurement of Protein Conformational Fluctuation in Ice by Passive Millimeter-Wave Microscopy
Thermal radiation emitted from an aqueous solution of bovine serum albumin (BSA) was measured and analyzed by passive millimeter-wave microscopy at a temperature range low enough to freeze water and to trap conformational intermediates in BSA. Experiments were performed at a millimeter-wave frequency of 50 GHz in a temperature range from 130 K to 270 K for a 20 % BSA aqueous solution, showing a displacement between two conformational states of BSA at a boundary temperature of approximately 190 K. Our microscope system using this freeze-trapping method is expected to provide noninvasive thermal images to enable novel high-throughput calorimetry useful for the analysis of protein functions.