Matthieu Vegreville
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matthieu Vegreville has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Normand
Nokia Health, Issy-les-Moulineaux, France
2 shared publications - Brooke Brawley
Brigham & Women's Hospital, Boston, MA, United States
2 shared publications - Eric J. Topol
Scripps Research Translational Institute, Scripps Research, La Jolla, USA
2 shared publications - Erin Woodbury
Brigham & Women's Hospital, Boston, MA, United States
2 shared publications - Eva Roitmann
Department of Digital Health, Data and Studies, Nokia Technologies, Issy-Les-Moulineaux, France
2 shared publications - Giorgio Quer
Scripps Research Translational Institute, La Jolla, USA
2 shared publications
Latest Publications
- Open Access
- 1 February 2019
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 7 (2) , e11190
Middle-Aged Men With HIV Have Diminished Accelerometry-Based Activity Profiles Despite Similar Lab-Measured Gait Speed: Pilot Study
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- 1 February 2019
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 7 (2) , e11190
Open AccessMiddle-Aged Men With HIV Have Diminished Accelerometry-Based Activity Profiles Despite Similar Lab-Measured Gait Speed: Pilot Study
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- Open Access
- 2 June 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Middle-Aged Men With HIV Have Diminished Accelerometry-Based Activity Profiles Despite Similar Lab-Measured Gait Speed: Pilot Study (Preprint)
BACKGROUND People aging with HIV are living with increased risk for functional decline compared with uninfected adults of the same age. Early preclinical changes in biomarkers in middle-aged individuals at risk for mobility and functional decline are needed. OBJECTIVE This pilot study aims to compare measures of free-living activity with lab-based measures. In addition, we aim to examine differences in the activity level and patterns by HIV status. METHODS Forty-six men (23 HIV+, 23 HIV−) currently in the MATCH (Muscle and Aging Treated Chronic HIV) cohort study wore a consumer-grade wristband accelerometer continuously for 3 weeks. We used free-living activity to calculate the gait speed and time spent at different activity intensities. Accelerometer data were compared with lab-based gait speed using the 6-minute walk test (6-MWT). Plasma biomarkers were measured and biobehavioral questionnaires were administered. RESULTS HIV+ men more often lived alone (P=.02), reported more pain (P=.02), and fatigue (P=.048). In addition, HIV+ men had lower blood CD4/CD8 ratios (P<.001) and higher Veterans Aging Cohort Study Index scores (P=.04) and T-cell activation (P<.001) but did not differ in levels of inflammation (P=.30) or testosterone (P=.83). For all participants, accelerometer-based gait speed was significantly lower than the lab-based 6-MWT gait speed (P<.001). Moreover, accelerometer-based gait speed was significantly lower in HIV+ participants (P=.04) despite the absence of differences in the lab-based 6-MWT (P=.39). HIV+ participants spent more time in the lowest quartile of activity compared with uninfected (P=.01), who spent more time in the middle quartiles of activity (P=.02). CONCLUSIONS Accelerometer-based assessment of gait speed and activity patterns are lower for asymptomatic men living with HIV compared with uninfected controls and may be useful as preclinical digital biomarkers that precede differences captured in lab-based measures.
- 2 June 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessMiddle-Aged Men With HIV Have Diminished Accelerometry-Based Activity Profiles Despite Similar Lab-Measured Gait Speed: Pilot Study (Preprint)
BACKGROUND People aging with HIV are living with increased risk for functional decline compared with uninfected adults of the same age. Early preclinical changes in biomarkers in middle-aged individuals at risk for mobility and functional decline are needed. OBJECTIVE This pilot study aims to compare measures of free-living activity with lab-based measures. In addition, we aim to examine differences in the activity level and patterns by HIV status. METHODS Forty-six men (23 HIV+, 23 HIV−) currently in the MATCH (Muscle and Aging Treated Chronic HIV) cohort study wore a consumer-grade wristband accelerometer continuously for 3 weeks. We used free-living activity to calculate the gait speed and time spent at different activity intensities. Accelerometer data were compared with lab-based gait speed using the 6-minute walk test (6-MWT). Plasma biomarkers were measured and biobehavioral questionnaires were administered. RESULTS HIV+ men more often lived alone (P=.02), reported more pain (P=.02), and fatigue (P=.048). In addition, HIV+ men had lower blood CD4/CD8 ratios (P<.001) and higher Veterans Aging Cohort Study Index scores (P=.04) and T-cell activation (P<.001) but did not differ in levels of inflammation (P=.30) or testosterone (P=.83). For all participants, accelerometer-based gait speed was significantly lower than the lab-based 6-MWT gait speed (P<.001). Moreover, accelerometer-based gait speed was significantly lower in HIV+ participants (P=.04) despite the absence of differences in the lab-based 6-MWT (P=.39). HIV+ participants spent more time in the lowest quartile of activity compared with uninfected (P=.01), who spent more time in the middle quartiles of activity (P=.02). CONCLUSIONS Accelerometer-based assessment of gait speed and activity patterns are lower for asymptomatic men living with HIV compared with uninfected controls and may be useful as preclinical digital biomarkers that precede differences captured in lab-based measures.
- Open Access
- 23 December 2017
- Published by Oxford University Press (OUP) in American Journal of Hypertension
- Vol. 31 (5) , 566-573
Real World Home Blood Pressure Variability in Over 56,000 Individuals With Nearly 17 Million Measurements
Using the data from 56,365 individuals, from 185 countries, and a Nokia Health Wireless blood pressure (BP) monitor, we investigated real-world characteristics of BP variability (BPV). All included individuals self-measured and uploaded their BP using Bluetooth at least 20 times over a period of ≥1 month at a frequency and duration of their choosing. In total, 16,904,844 BP measurements were analyzed, with a median of 146 measurements per person (interquartile range [IQR] 73–321) over a median of 14 months (IQR 7–31). SD, coefficient of variation, maximum BP, and maximum minus minimum BP difference were all calculated as measures of BPV. BPV showed a distinct pattern, influenced by season of year, day of week, and time of day. BPV index was higher in females compared with males (P < 0.001) and increased with age (P < 0.001). Compared to the weekend, the weekday BPV index was significantly higher, and this finding was more prominent in females (P = 0.001). In multivariate analysis, BPV index were significantly associated with age, gender, geographic location, and mean BP values. Using the largest BP data set we are aware of, with the benefits and limitations of real-world measurement, we could show the pattern of BPV and provide reference values that may be helpful in understanding the nature of BPV as self-measurement at home becomes more common, and help guide individualized management.
- 23 December 2017
- Published by Oxford University Press (OUP) in American Journal of Hypertension
- Vol. 31 (5) , 566-573
Open AccessReal World Home Blood Pressure Variability in Over 56,000 Individuals With Nearly 17 Million Measurements
Using the data from 56,365 individuals, from 185 countries, and a Nokia Health Wireless blood pressure (BP) monitor, we investigated real-world characteristics of BP variability (BPV). All included individuals self-measured and uploaded their BP using Bluetooth at least 20 times over a period of ≥1 month at a frequency and duration of their choosing. In total, 16,904,844 BP measurements were analyzed, with a median of 146 measurements per person (interquartile range [IQR] 73–321) over a median of 14 months (IQR 7–31). SD, coefficient of variation, maximum BP, and maximum minus minimum BP difference were all calculated as measures of BPV. BPV showed a distinct pattern, influenced by season of year, day of week, and time of day. BPV index was higher in females compared with males (P < 0.001) and increased with age (P < 0.001). Compared to the weekend, the weekday BPV index was significantly higher, and this finding was more prominent in females (P = 0.001). In multivariate analysis, BPV index were significantly associated with age, gender, geographic location, and mean BP values. Using the largest BP data set we are aware of, with the benefits and limitations of real-world measurement, we could show the pattern of BPV and provide reference values that may be helpful in understanding the nature of BPV as self-measurement at home becomes more common, and help guide individualized management.
- 23 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (5) , 1691-1698
Home Monitoring of Blood Pressure: Short–Term Changes During Serial Measurements for 56398 Subjects
Hypertension is one of the greatest contributors to premature morbidity and mortality worldwide. It has been demonstrated that lowering blood pressure (BP) by just a few mmHg can bring substantial clinical benefits, reducing the risk of stroke and ischemic heart disease. Properly managing high BP is one of the most pressing global health issues, but accurate methods to continuously monitoring BP at home are still under discussion. Indeed, the BP for any given individual can fluctuate significantly during intervals as short as a few minutes. In clinical settings, the guidelines suggest to wait for 5 or 10 minutes in seated rest before taking the measure, in order to alleviate the effect of the stress induced by the clinical environment. Alternatively, BP measured in the home environment is thought to provide a more accurate measure free of the stress of a clinical environment, but there is currently a lack of extensive studies on the trajectory of serial BP measurements over minutes in the home setting. In this paper, we aim at filling this gap by analyzing a large dataset of more than 16 million BP measurements taken at home with commercial BP monitoring devices. In particular, we propose new techniques to analyze this dataset, taking into account the limitations due to the uncontrolled data collection, and we study the characteristics of the BP trajectory for consecutive measures over several minutes. We show that the BP values significantly decrease after 10 minutes minutes from the initial measurement (4.1 and 6.6 mmHg for the diastolic and systolic BP, respectively), and continue to decrease for about 25 minutes. We also describe statistically the clinical relevance of this change, observing more than 50% misclassifications for measurements in the hypertension region. We then propose a model to study the inter-subject variability, showing significant variations in the expected decrease in systolic BP. These results may provide the initial evidence for future large clinical studies using participant-monitored BP.
- 23 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (5) , 1691-1698
Home Monitoring of Blood Pressure: Short–Term Changes During Serial Measurements for 56398 Subjects
Hypertension is one of the greatest contributors to premature morbidity and mortality worldwide. It has been demonstrated that lowering blood pressure (BP) by just a few mmHg can bring substantial clinical benefits, reducing the risk of stroke and ischemic heart disease. Properly managing high BP is one of the most pressing global health issues, but accurate methods to continuously monitoring BP at home are still under discussion. Indeed, the BP for any given individual can fluctuate significantly during intervals as short as a few minutes. In clinical settings, the guidelines suggest to wait for 5 or 10 minutes in seated rest before taking the measure, in order to alleviate the effect of the stress induced by the clinical environment. Alternatively, BP measured in the home environment is thought to provide a more accurate measure free of the stress of a clinical environment, but there is currently a lack of extensive studies on the trajectory of serial BP measurements over minutes in the home setting. In this paper, we aim at filling this gap by analyzing a large dataset of more than 16 million BP measurements taken at home with commercial BP monitoring devices. In particular, we propose new techniques to analyze this dataset, taking into account the limitations due to the uncontrolled data collection, and we study the characteristics of the BP trajectory for consecutive measures over several minutes. We show that the BP values significantly decrease after 10 minutes minutes from the initial measurement (4.1 and 6.6 mmHg for the diastolic and systolic BP, respectively), and continue to decrease for about 25 minutes. We also describe statistically the clinical relevance of this change, observing more than 50% misclassifications for measurements in the hypertension region. We then propose a model to study the inter-subject variability, showing significant variations in the expected decrease in systolic BP. These results may provide the initial evidence for future large clinical studies using participant-monitored BP.
- Open Access
- 23 October 2017
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 19 (10) , e363
An International Study on the Determinants of Poor Sleep Amongst 15,000 Users of Connected Devices
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet
- 23 October 2017
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 19 (10) , e363
Open AccessAn International Study on the Determinants of Poor Sleep Amongst 15,000 Users of Connected Devices
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet