Pavel Alexandrovich Taranenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pavel Alexandrovich Taranenko has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
A.A. Yaushev
4 shared publications- Afrasyab Khan
Institute of Engineering and Technology, Department of Hydraulics and Hydraulic and Pneumatic Systems, South Ural State University, Lenin Prospect 76, 454080 Chelyabinsk, Russia
3 shared publications - Andrew Ragai Henry Rigit
Faculty of Mechanical Engineering, Universiti Malaysia Sarawak, Jalan Datuk Mohammad Musa, 94300 Kota Samarahan, Sarawak, Malaysia
3 shared publications - Khairuddin Sanaullah
Department of Chemical and Energy Sustainability, Faculty of Engineering, Universiti Malaysia Sarawak (UNIMAS), Malaysia
3 shared publications V.A. Loginovskiy
3 shared publications- Vladimir Vladimirovich Sinitsin
Research Laboratory of Technical Self-Diagnostics and Self-Control of Devices and Systems, Department of Scientific and Innovative Activities, South Ural State University, Lenin prospect 76, Chelyabinsk, 454080, Russian Federation
3 shared publications
Latest Publications
- Open Access
- 26 May 2025
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 631, 02002
Hydrodynamics of Steam-Water Two-Phase Flows Through Grooved Walled Passages
In this study, we investigated the flow hydrodynamics of mixture of steam and water through a pipe that has grooved walls. The walls were roughened using collars that has circular and squared shapes throughout the inner walls of the flow channel. Our findings indicate that the factors related to the friction of the walls have been associated with wall roughness ranged from 0.6 to 0.63. The velocity deficit near the wall was slightly greater above the smooth walls compared to the rough walls, reflecting the impact of the friction factor. However, the profiles used to quantify the Reynolds normal stresses showed a distinct contrast. In the grooved surface channel, pressure-induced drag dominated, leaving little room for viscous effects and resulting in lower peaks. These stresses were heavily influenced by wall geometry. Notably, in channels with squared grooves, flow profiles were shows a slight decrease compared to those observed over smooth and rough walls.
- 26 May 2025
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 631, 02002
Open AccessHydrodynamics of Steam-Water Two-Phase Flows Through Grooved Walled Passages
In this study, we investigated the flow hydrodynamics of mixture of steam and water through a pipe that has grooved walls. The walls were roughened using collars that has circular and squared shapes throughout the inner walls of the flow channel. Our findings indicate that the factors related to the friction of the walls have been associated with wall roughness ranged from 0.6 to 0.63. The velocity deficit near the wall was slightly greater above the smooth walls compared to the rough walls, reflecting the impact of the friction factor. However, the profiles used to quantify the Reynolds normal stresses showed a distinct contrast. In the grooved surface channel, pressure-induced drag dominated, leaving little room for viscous effects and resulting in lower peaks. These stresses were heavily influenced by wall geometry. Notably, in channels with squared grooves, flow profiles were shows a slight decrease compared to those observed over smooth and rough walls.
- Open Access
- 20 January 2025
- Published by MDPI AG in Preprints.org
An Experimental Study Of The Vortical Structures In Supersonic Steam Jet Impinged On To The Wall
This study presents an experimental investigation into the impingement of a supersonic steam jet onto a wall. Steam was injected through a supersonic nozzle at a varying total pressure of 1.5-3.0 bars, producing a supersonic steam jet at a pressure gradient of 0.5-2.0 bars. The whole fluid domain is comprised of two regions: the jet region and the region near the wall involving the impingement of the supersonic steam jet. Within this region, the transformation of primary vortices into secondary vortices occurs and these vortices expel outward in the radial direction after impingement. Measurements have shown the spreading of the normalized density of the vortical structures along the axial length within the region near the wall. However, the probability density function analysis has indicated that the vortical structures become denser within the impingement region. Whereas subsequent to an impingement of the steam jet onto the wall, along the radial direction, weak traces of their existence in the jet region may be attributed to the vorticity diffusion within the jet region.
- 20 January 2025
- Published by MDPI AG in Preprints.org
Open AccessAn Experimental Study Of The Vortical Structures In Supersonic Steam Jet Impinged On To The Wall
This study presents an experimental investigation into the impingement of a supersonic steam jet onto a wall. Steam was injected through a supersonic nozzle at a varying total pressure of 1.5-3.0 bars, producing a supersonic steam jet at a pressure gradient of 0.5-2.0 bars. The whole fluid domain is comprised of two regions: the jet region and the region near the wall involving the impingement of the supersonic steam jet. Within this region, the transformation of primary vortices into secondary vortices occurs and these vortices expel outward in the radial direction after impingement. Measurements have shown the spreading of the normalized density of the vortical structures along the axial length within the region near the wall. However, the probability density function analysis has indicated that the vortical structures become denser within the impingement region. Whereas subsequent to an impingement of the steam jet onto the wall, along the radial direction, weak traces of their existence in the jet region may be attributed to the vorticity diffusion within the jet region.
- Open Access
- 1 January 2025
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 17 (1) , 32-39
INVESTIGATION OF TWO-COMPONENT FLOW “LIQUID–GAS” INFLUENCE ON A CORIOLIS FLOWMETER DYNAMIC PARAMETERS
In connection with the development of methods for determining the volume-mass parameters of “liquid–gas” performed by a team of scientists from the South Ural State University, the paper presents the results of full-scale tests and modeling of the operation of a Coriolis flowmeter with a gasliquid mixture flow. The study aims to establish the causes of reduction of measurement accuracy by the device with an increase in the gas phase in the fluid flow. For this purpose, a series of pouring tests were performed on a specialized stand with the possibility of injecting a gas fraction into the liquid flow. The gas volume fraction in the fluid was calculated. A simulation model of the measuring tube of the Coriolis flowmeter was built and a non-stationary calculation was performed in the mechanical and hydrodynamic module with two-way transmission of pressure and displacement fields at each time step. The gas-liquid mixture was modeled using the VOF model. Based on the simulation results, it was found that the reduction in mass flow measurement accuracy is affected by the physics of the process occurring in the “flow tube – gas-liquid flow” system. A comparative analysis of the calculation and test results was performed, and their qualitative coincidence was shown. It was found that in the case of a two-phase flow, the control electronics and signal processing algorithms are not the main source of measurement error.
- 1 January 2025
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 17 (1) , 32-39
Open AccessINVESTIGATION OF TWO-COMPONENT FLOW “LIQUID–GAS” INFLUENCE ON A CORIOLIS FLOWMETER DYNAMIC PARAMETERS
In connection with the development of methods for determining the volume-mass parameters of “liquid–gas” performed by a team of scientists from the South Ural State University, the paper presents the results of full-scale tests and modeling of the operation of a Coriolis flowmeter with a gasliquid mixture flow. The study aims to establish the causes of reduction of measurement accuracy by the device with an increase in the gas phase in the fluid flow. For this purpose, a series of pouring tests were performed on a specialized stand with the possibility of injecting a gas fraction into the liquid flow. The gas volume fraction in the fluid was calculated. A simulation model of the measuring tube of the Coriolis flowmeter was built and a non-stationary calculation was performed in the mechanical and hydrodynamic module with two-way transmission of pressure and displacement fields at each time step. The gas-liquid mixture was modeled using the VOF model. Based on the simulation results, it was found that the reduction in mass flow measurement accuracy is affected by the physics of the process occurring in the “flow tube – gas-liquid flow” system. A comparative analysis of the calculation and test results was performed, and their qualitative coincidence was shown. It was found that in the case of a two-phase flow, the control electronics and signal processing algorithms are not the main source of measurement error.
- Open Access
Optimization of Tensile Strength and Young’s Modulus of CNT–CF/Epoxy Composites Using Response Surface Methodology (RSM)
Composites such as carbon fiber are used extensively by automotive, aerospace, marine, and energy industries due to their strong mechanical properties. However, there are still many areas it is lacking in testing, especially related to its electrophoretic deposition. In this research work, the tensile strength and Young’s modulus of CNT–CF/epoxy composites were measured using the tensile test by varying the electrophoretic deposition (EPD) process parameters. Response surface methodology (RSM) was used to optimize the three main parameters in this EPD process: the volume ratio (water as the basis), deposition voltage, and time to obtain the maximum tensile properties of the composites. There were four volume ratios (0%, 20%, 80% and 100%) used in this design of experiment (DoE) with ratios’ pairs of 0%, 100%, and 20%, 80%. For this study, water and methanol were used as the suspension medium. This design’s deposition voltage and time were 10 to 20 V and 5 to 15 min. ANOVA further verified the responses’ adequacy. The optimum conditions for the first Design of Experiment (DoE) (0% and 100%) were identified as a volume ratio of 99.99% water, deposition voltage of 10 V, and 12.14 min. These conditions provided the maximum strength of these composites with a tensile strength of 7.41 N/mm2 and Young’s modulus of 279.9 N/mm2. Subsequently, for the second DoE (20% and 80%), tensile strength of 7.28 N/mm2 and Young’s modulus of 274.1 N/mm2 were achieved with the ideal conditions: volume ratio of 44.80% water, deposition voltage of 10.04 V, and time of 6.89 min. It can be concluded that the ideal interaction between these three EPD parameters was necessary to achieve composites with good tensile properties.
Open AccessOptimization of Tensile Strength and Young’s Modulus of CNT–CF/Epoxy Composites Using Response Surface Methodology (RSM)
Composites such as carbon fiber are used extensively by automotive, aerospace, marine, and energy industries due to their strong mechanical properties. However, there are still many areas it is lacking in testing, especially related to its electrophoretic deposition. In this research work, the tensile strength and Young’s modulus of CNT–CF/epoxy composites were measured using the tensile test by varying the electrophoretic deposition (EPD) process parameters. Response surface methodology (RSM) was used to optimize the three main parameters in this EPD process: the volume ratio (water as the basis), deposition voltage, and time to obtain the maximum tensile properties of the composites. There were four volume ratios (0%, 20%, 80% and 100%) used in this design of experiment (DoE) with ratios’ pairs of 0%, 100%, and 20%, 80%. For this study, water and methanol were used as the suspension medium. This design’s deposition voltage and time were 10 to 20 V and 5 to 15 min. ANOVA further verified the responses’ adequacy. The optimum conditions for the first Design of Experiment (DoE) (0% and 100%) were identified as a volume ratio of 99.99% water, deposition voltage of 10 V, and 12.14 min. These conditions provided the maximum strength of these composites with a tensile strength of 7.41 N/mm2 and Young’s modulus of 279.9 N/mm2. Subsequently, for the second DoE (20% and 80%), tensile strength of 7.28 N/mm2 and Young’s modulus of 274.1 N/mm2 were achieved with the ideal conditions: volume ratio of 44.80% water, deposition voltage of 10.04 V, and time of 6.89 min. It can be concluded that the ideal interaction between these three EPD parameters was necessary to achieve composites with good tensile properties.
- Open Access
Hydrodynamics of Direct Contact Condensation Process in Desuperheater
Due to global environmental conditions, the focus of household heating has shifted from fossil fuels towards environmentally friendly and renewable energy sources. Desuperheaters have attracted attention as a domestic provision involving steam-induced direct contact condensation (DCC)to warm the water. The present study is an attempt to investigate the hydrodynamics in the desuperheater vessel experimentally, namely, when the pressurized pulsating steam is injected into the vessel, where the steam jet interacts co-currently with the slow-moving water. Flow visualization showed a circulation region when the pulsating steam was injected into the slow-moving water, and the peaked vorticity corresponded to the steam injection duration of 10–60 s. Sevenhot film anemometers (HFAs) were traversed axially and radially to determine the velocity fluctuations at 0–20 cm from the steam’s nozzle exit. Vortical structures indicated the entrainment of the steam with the surrounding moving water. The circulation regions were thus exhibited in relation to the steam’s injection durations as well as the downstream axial distances of 2 and 15 cm from the nozzle exit, which showed that the core local circulation at 2 cm downstream of the nozzle exit lost 75–79% of its circulation at 15 cm downstream of the nozzle exit.
Open AccessHydrodynamics of Direct Contact Condensation Process in Desuperheater
Due to global environmental conditions, the focus of household heating has shifted from fossil fuels towards environmentally friendly and renewable energy sources. Desuperheaters have attracted attention as a domestic provision involving steam-induced direct contact condensation (DCC)to warm the water. The present study is an attempt to investigate the hydrodynamics in the desuperheater vessel experimentally, namely, when the pressurized pulsating steam is injected into the vessel, where the steam jet interacts co-currently with the slow-moving water. Flow visualization showed a circulation region when the pulsating steam was injected into the slow-moving water, and the peaked vorticity corresponded to the steam injection duration of 10–60 s. Sevenhot film anemometers (HFAs) were traversed axially and radially to determine the velocity fluctuations at 0–20 cm from the steam’s nozzle exit. Vortical structures indicated the entrainment of the steam with the surrounding moving water. The circulation regions were thus exhibited in relation to the steam’s injection durations as well as the downstream axial distances of 2 and 15 cm from the nozzle exit, which showed that the core local circulation at 2 cm downstream of the nozzle exit lost 75–79% of its circulation at 15 cm downstream of the nozzle exit.
- 25 July 2022
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 11 (3) , 1101-1113
Effects of External Oscillations on Cocurrently Flowing Steam–Water in Pipes
- 25 July 2022
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 11 (3) , 1101-1113
Effects of External Oscillations on Cocurrently Flowing Steam–Water in Pipes
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1067 (1) , 012119
Experimental and numerical evaluation of natural frequencies and mode shapes in a satellite model-plate connecting interface without vibration isolators
This paper numerically and experimentally examines the natural frequencies and mode shapes in a satellite model-plate connecting interface installed on flexible gas-inflated jacks in order to assess the effect of external impacts on the natural frequencies of the satellite model and to thus generate a reference for appropriate vibration isolators for transportation and launch as required. The experimental determination of the frequencies and mode shapes of vibration in the system was carried out using modern software in conjunction with the hardware loading model satellite (LMS). Numerical calculation of the natural frequencies and mode shapes of the research object was performed in the finite element package ANSYS Workbench, with results suggesting that the suspension system (gas inflatable jacks) was sufficiently flexible and did not affect the natural frequencies at which the system under investigation, the satellite model-connecting interface plate, began to deform. Experimental determination of the natural frequencies and mode shapes of vibration for the satellite model-connecting interface plate was then conducted in the range from 44 Hz to 200 Hz; the differences in natural frequencies between the calculations and experiments averaged 10 to 15%.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1067 (1) , 012119
Open AccessExperimental and numerical evaluation of natural frequencies and mode shapes in a satellite model-plate connecting interface without vibration isolators
This paper numerically and experimentally examines the natural frequencies and mode shapes in a satellite model-plate connecting interface installed on flexible gas-inflated jacks in order to assess the effect of external impacts on the natural frequencies of the satellite model and to thus generate a reference for appropriate vibration isolators for transportation and launch as required. The experimental determination of the frequencies and mode shapes of vibration in the system was carried out using modern software in conjunction with the hardware loading model satellite (LMS). Numerical calculation of the natural frequencies and mode shapes of the research object was performed in the finite element package ANSYS Workbench, with results suggesting that the suspension system (gas inflatable jacks) was sufficiently flexible and did not affect the natural frequencies at which the system under investigation, the satellite model-connecting interface plate, began to deform. Experimental determination of the natural frequencies and mode shapes of vibration for the satellite model-connecting interface plate was then conducted in the range from 44 Hz to 200 Hz; the differences in natural frequencies between the calculations and experiments averaged 10 to 15%.
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1094 (1) , 012020
An Experimental and Numerical Evaluation of Natural Frequencies and Mode Shapes using Vibration Isolator to Transport “Satellite Model–Plate Connecting Interface” System
This paper examines the natural frequencies and mode shape numerically and experimentally using vibration isolator for satellite model-plate connecting interface. The experiment was carried out using a modern software and hardware complex LMS. Vibration accelerations on the object were measured at 13 points in three mutually perpendicular directions using one-component and three-component PCB accelerometers with a sensitivity of 100 mV/g. Excitation was carried out with a PCB 086D50 m modal hammer. The SCADAS mobile data acquisition system was utilized to record the response from the sensors. While the numerical calculations were performed in the finite element package ANSYS Workbench. The result shows that the natural frequencies are less dependent on the system damping where the most considerable difference (about 10%) is observed in those forms, which plate makes flexural vibrations; the six natural modes of vibration of the satellite model (as a rigid body), the first three lowest forms correspond to vibrations in the plane. While the other oscillations were out of the plane, to reduce the oscillation frequency of the product from the plane (around the x and z axes), it is recommended to reduce the distance between the shock absorbers.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1094 (1) , 012020
Open AccessAn Experimental and Numerical Evaluation of Natural Frequencies and Mode Shapes using Vibration Isolator to Transport “Satellite Model–Plate Connecting Interface” System
This paper examines the natural frequencies and mode shape numerically and experimentally using vibration isolator for satellite model-plate connecting interface. The experiment was carried out using a modern software and hardware complex LMS. Vibration accelerations on the object were measured at 13 points in three mutually perpendicular directions using one-component and three-component PCB accelerometers with a sensitivity of 100 mV/g. Excitation was carried out with a PCB 086D50 m modal hammer. The SCADAS mobile data acquisition system was utilized to record the response from the sensors. While the numerical calculations were performed in the finite element package ANSYS Workbench. The result shows that the natural frequencies are less dependent on the system damping where the most considerable difference (about 10%) is observed in those forms, which plate makes flexural vibrations; the six natural modes of vibration of the satellite model (as a rigid body), the first three lowest forms correspond to vibrations in the plane. While the other oscillations were out of the plane, to reduce the oscillation frequency of the product from the plane (around the x and z axes), it is recommended to reduce the distance between the shock absorbers.
- Open Access
- 1 March 2019
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mechanical Engineering Industry"
- Vol. 19 (1) , 47-55
CALCULATED AND EXPERIMENTAL ZERO STABILITY OF A CORIOLIS FLOWMETER RELATED TO THE ELASTIC AND DAMPING PROPERTIES OF ITS FIXTURE
РАСЧЕТНО-ЭКСПЕРИМЕНТАЛЬНОЕ ИССЛЕДОВАНИЕ СТАБИЛЬНОСТИ НУЛЯ КОРИОЛИСОВОГО РАСХОДОМЕРА В ЗАВИСИМОСТИ ОТ УПРУГОДЕМПФИРУЮЩИХ СВОЙСТВ ЗАКРЕПЛЕНИЯ
- 1 March 2019
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mechanical Engineering Industry"
- Vol. 19 (1) , 47-55
Open AccessCALCULATED AND EXPERIMENTAL ZERO STABILITY OF A CORIOLIS FLOWMETER RELATED TO THE ELASTIC AND DAMPING PROPERTIES OF ITS FIXTURE
РАСЧЕТНО-ЭКСПЕРИМЕНТАЛЬНОЕ ИССЛЕДОВАНИЕ СТАБИЛЬНОСТИ НУЛЯ КОРИОЛИСОВОГО РАСХОДОМЕРА В ЗАВИСИМОСТИ ОТ УПРУГОДЕМПФИРУЮЩИХ СВОЙСТВ ЗАКРЕПЛЕНИЯ
- Open Access
- 1 January 2019
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 11 (3) , 47-55
GAS BUBBLES EFFECT ON THE VIBRATION PARAMETERS OF THE CORIOLIS FLOWMETER MEASURING TUBES
- 1 January 2019
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 11 (3) , 47-55
Open AccessGAS BUBBLES EFFECT ON THE VIBRATION PARAMETERS OF THE CORIOLIS FLOWMETER MEASURING TUBES