Samantha Thomas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samantha Thomas has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
Jillian Clarke
Faculty of Medicine and Health, Medical Imaging Science, University of Sydney, Sydney, Australia
4 shared publications- Jillian Clarke
Faculty of Medicine and Health The University of Sydney Sydney New South Wales Australia
4 shared publications - Ann Quinton
School of Health, Medical and Applied Sciences, College of Clinical Sciences Central Queensland University Sydney New South Wales Australia
2 shared publications - Donna Oomens
Faculty of Medicine and Health The University of Sydney Sydney New South Wales Australia
2 shared publications Kate O’lOughlin
Faculty of Medicine and Health, Ageing, Work and Health Research Unit, University of Sydney, Sydney, Australia
2 shared publications- Sarah Dowthwaite
Faculty of Medicine and Health The University of Sydney Sydney New South Wales Australia
2 shared publications
Latest Publications
- Open Access
- 6 March 2026
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 105 (5) , 827-835
Outcomes from blind versus ultrasound‐guided uterine evacuation: A retrospective cohort analysis
Introduction: Women may need a surgical uterine evacuation for miscarriage, surgical termination, or retained products of conception. Previous research has indicated possible complications of uterine dilatation and curettage and potential benefits of an ultrasound‐guided procedure. This study aimed to compare the rate of complications for uterine evacuation when performed blind or with ultrasound guidance, including whether the presence of patient risk factors determined the use of ultrasound guidance. Material and Methods: This retrospective cohort study included 733 cases in an Australian hospital between January 2019 and December 2023. Medical records, imaging, and surgical reports were searched for patient demographics, risk factors, and the presence of surgical complications. Primary outcomes were complications of uterine perforation, false passage, incomplete curettage, heavy blood loss, or laparoscopy. Secondary outcomes were patient demographics and potential presurgical complication factors. The study created two cohorts: patients receiving evacuation performed blind or with ultrasound guidance. Results: The uterine evacuation was performed blind for 421/733 (57%) women and ultrasound‐guided for 312/733 (43%) women. The ultrasound‐guided group included higher gestational ages 8 [7–11] weeks vs blind 8 [7–9] weeks, more patients with risk factors (OR 1.7, CI: 1.3 to 2.3), more patients for surgical termination (OR 15.3, CI: 5.4 to 43.3), or postpartum RPOC removal (OR 2.3, CI: 1.3 to 3.9). The ultrasound group had lower overall blood loss (20 mLs vs 30 mL) and clinically significantly lower volumes of continuing retained products of conception, 0.66 cm 3 [0.53–1.23] vs 8.35 cm 3 [1.49–18.94]. There was no difference in complications between groups after adjusting for gestational age (OR 1.0, CI: 0.5 to 2.0). Conclusions: There were low complication rates for blind and ultrasound‐guided uterine evacuations. However, ultrasound guidance was utilized for higher‐risk cases and significantly reduced the volume of retained tissue in complicated cases. The use of ultrasound guidance by doctors and sonographers for uterine evacuation is a compelling choice where available.
- 6 March 2026
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 105 (5) , 827-835
Open AccessOutcomes from blind versus ultrasound‐guided uterine evacuation: A retrospective cohort analysis
Introduction: Women may need a surgical uterine evacuation for miscarriage, surgical termination, or retained products of conception. Previous research has indicated possible complications of uterine dilatation and curettage and potential benefits of an ultrasound‐guided procedure. This study aimed to compare the rate of complications for uterine evacuation when performed blind or with ultrasound guidance, including whether the presence of patient risk factors determined the use of ultrasound guidance. Material and Methods: This retrospective cohort study included 733 cases in an Australian hospital between January 2019 and December 2023. Medical records, imaging, and surgical reports were searched for patient demographics, risk factors, and the presence of surgical complications. Primary outcomes were complications of uterine perforation, false passage, incomplete curettage, heavy blood loss, or laparoscopy. Secondary outcomes were patient demographics and potential presurgical complication factors. The study created two cohorts: patients receiving evacuation performed blind or with ultrasound guidance. Results: The uterine evacuation was performed blind for 421/733 (57%) women and ultrasound‐guided for 312/733 (43%) women. The ultrasound‐guided group included higher gestational ages 8 [7–11] weeks vs blind 8 [7–9] weeks, more patients with risk factors (OR 1.7, CI: 1.3 to 2.3), more patients for surgical termination (OR 15.3, CI: 5.4 to 43.3), or postpartum RPOC removal (OR 2.3, CI: 1.3 to 3.9). The ultrasound group had lower overall blood loss (20 mLs vs 30 mL) and clinically significantly lower volumes of continuing retained products of conception, 0.66 cm 3 [0.53–1.23] vs 8.35 cm 3 [1.49–18.94]. There was no difference in complications between groups after adjusting for gestational age (OR 1.0, CI: 0.5 to 2.0). Conclusions: There were low complication rates for blind and ultrasound‐guided uterine evacuations. However, ultrasound guidance was utilized for higher‐risk cases and significantly reduced the volume of retained tissue in complicated cases. The use of ultrasound guidance by doctors and sonographers for uterine evacuation is a compelling choice where available.
- 21 November 2025
- Published by Wiley in Australian and New Zealand Journal of Obstetrics and Gynaecology
- Vol. 66 (1)
Ultrasound Guidance to Reduce Complications During Uterine Curettage: A Systematic Review and Meta‐Analysis
Background: Surgical management of pregnancy loss with retained products of conception (RPOC), may result in uterine perforation, incomplete evacuation, heavy blood loss, infection or cervical trauma. Ultrasound guidance could reduce complications. Aims: To review studies on uterine curettage for RPOC comparing real‐time ultrasound and blinded guidance and perform a meta‐analysis to determine whether ultrasound reduces complications. Materials and Methods: A systematic literature review was performed to identify studies on 24 August 2023 with further reference mining occurring up until 29 February 2024. Six studies with 1491 participants provided data on 585 participants assigned to ultrasound guidance and 906 assigned to blinded guidance. The measures of treatment effect for dichotomous outcomes—uterine perforation, RPOC, blood loss, infection and cervical trauma—were analysed and compared between the ultrasound and blinded group. A meta‐analysis was performed for each outcome using inverse‐variance and calculated I 2 to test heterogeneity. Estimated relative risk (95% CIs), odds ratio (OR, 95% CIs), absolute risk reduction and number needed to treat were calculated. Risk of bias was assessed using the Downs and Black tool and GRADE for certainty. Results: Five studies including 1218 women provided data for persistent RPOC. Compared to blinded guidance, ultrasound‐guided women had a decreased chance of persistent RPOC (OR, 0.19, 95% CI 0.08–0.43, I 2 0%, high‐certainty evidence). The association between ultrasound guidance and uterine perforation, blood loss, infection and cervical trauma was not significant, with serious concern for imprecision or inconsistency. Conclusion: Ultrasound reduces the risk of persistent RPOC with a high certainty of evidence. Trial Registration: Prospective register of systematic reviews (PROSPERO): CRD42023447614 (1st August 2023)
- 21 November 2025
- Published by Wiley in Australian and New Zealand Journal of Obstetrics and Gynaecology
- Vol. 66 (1)
Ultrasound Guidance to Reduce Complications During Uterine Curettage: A Systematic Review and Meta‐Analysis
Background: Surgical management of pregnancy loss with retained products of conception (RPOC), may result in uterine perforation, incomplete evacuation, heavy blood loss, infection or cervical trauma. Ultrasound guidance could reduce complications. Aims: To review studies on uterine curettage for RPOC comparing real‐time ultrasound and blinded guidance and perform a meta‐analysis to determine whether ultrasound reduces complications. Materials and Methods: A systematic literature review was performed to identify studies on 24 August 2023 with further reference mining occurring up until 29 February 2024. Six studies with 1491 participants provided data on 585 participants assigned to ultrasound guidance and 906 assigned to blinded guidance. The measures of treatment effect for dichotomous outcomes—uterine perforation, RPOC, blood loss, infection and cervical trauma—were analysed and compared between the ultrasound and blinded group. A meta‐analysis was performed for each outcome using inverse‐variance and calculated I 2 to test heterogeneity. Estimated relative risk (95% CIs), odds ratio (OR, 95% CIs), absolute risk reduction and number needed to treat were calculated. Risk of bias was assessed using the Downs and Black tool and GRADE for certainty. Results: Five studies including 1218 women provided data for persistent RPOC. Compared to blinded guidance, ultrasound‐guided women had a decreased chance of persistent RPOC (OR, 0.19, 95% CI 0.08–0.43, I 2 0%, high‐certainty evidence). The association between ultrasound guidance and uterine perforation, blood loss, infection and cervical trauma was not significant, with serious concern for imprecision or inconsistency. Conclusion: Ultrasound reduces the risk of persistent RPOC with a high certainty of evidence. Trial Registration: Prospective register of systematic reviews (PROSPERO): CRD42023447614 (1st August 2023)
- Open Access
- 3 April 2025
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 65 (5) , 624-632
Automated multivolume placental reconstruction using three‐dimensional power Doppler ultrasound and infrared camera tracking
Objectives: Placental insufficiency contributes to many obstetric pathologies, but there is no bedside clinical tool to evaluate placental perfusion. We have developed a method to acquire multiple three‐dimensional (3D) power Doppler (PD) ultrasound (US) volumes of placental vasculature, with infrared camera tracking of the precise spatial location of the transducer providing global coordinates. These volumes are reconstructed automatically (‘stitched’) into a model of the entire placenta. The purpose of this study was to evaluate the accuracy of automated reconstruction in an US phantom and to assess the feasibility of this technique in second‐to‐third‐trimester human placentae.Methods: A custom‐designed acrylic phantom was constructed with dimensions mimicking a third‐trimester placenta, containing 12 rectangular cuboid towers of various heights submersed in tissue‐mimicking solution. Multiple overlapping 3D‐US volumes of this phantom were acquired using three different insonation angles and infrared camera tracking. Data were transformed into a 3D cartesian volume and stitched automatically into six 3D‐US volumes, each covering the entire phantom, for each of the three different insonation angles. Reconstruction accuracy was evaluated by calculating local distance error (assessment of towers in overlapping US volumes to determine accuracy of stitching) and global distance error (subtraction of true measurements in phantom model from corresponding measurements in stitched 3D‐US volumes). A single‐center, cross‐sectional feasibility study was then conducted in women with an uncomplicated second‐to‐third‐trimester singleton pregnancy, with data obtained using standardized ultrasound settings. Multiple 3D PD‐US and grayscale volumes of the placentae were acquired with infrared camera‐tracked coordinates. Volumes were stitched to create a model of placental vasculature, and these were assessed for quality and repeatability of volume measurement.Results: Six entire phantom datasets were reconstructed at each of three insonation angles, giving a total of 18 extended phanom datasets. A median of nine 3D‐US volumes required to reconstruct the entire phantom. Twelve towers per volume were assessed on three separate occasions, generating 648 datapoints. Of these datapoints, 67.1% were perfectly aligned. The mean local distance error was 2.92 (range, 0–25.51) mm. Measurements between towers of 120 distances in each stitched 3D‐US volume (2160 distances in total) differed by an average of 1.51 (range, −4.78 to 4.23) mm from the true measurements in the phantom model. In the feasibility study, 17 participants were scanned, and 49 3D‐US volume datasets acquired, with 92% reconstruction success per placental volume set and at least one complete volume being obtained per participant (100% participant achievability). The median volume acquisition and reconstruction time was 10 min. Reconstructed placental vasculature was assessed qualitatively to be present, continuous and detailed throughout. Volume measurement of entire segmented placentae was highly repeatable (intraclass correlation coefficient, 0.96 (95% CI, 0.89–0.99)).Conclusion: We present an automated method to model the entire structure and vasculature of second‐to‐third‐trimester placentae using multiple 3D PD‐US volumes, with verified accuracy and clinical feasibility. This study builds a foundation on which to develop a practical screening tool for detecting placental insufficiency and has the potential for expansion to evaluation of adult organ perfusion. © 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- 3 April 2025
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 65 (5) , 624-632
Open AccessAutomated multivolume placental reconstruction using three‐dimensional power Doppler ultrasound and infrared camera tracking
Objectives: Placental insufficiency contributes to many obstetric pathologies, but there is no bedside clinical tool to evaluate placental perfusion. We have developed a method to acquire multiple three‐dimensional (3D) power Doppler (PD) ultrasound (US) volumes of placental vasculature, with infrared camera tracking of the precise spatial location of the transducer providing global coordinates. These volumes are reconstructed automatically (‘stitched’) into a model of the entire placenta. The purpose of this study was to evaluate the accuracy of automated reconstruction in an US phantom and to assess the feasibility of this technique in second‐to‐third‐trimester human placentae.Methods: A custom‐designed acrylic phantom was constructed with dimensions mimicking a third‐trimester placenta, containing 12 rectangular cuboid towers of various heights submersed in tissue‐mimicking solution. Multiple overlapping 3D‐US volumes of this phantom were acquired using three different insonation angles and infrared camera tracking. Data were transformed into a 3D cartesian volume and stitched automatically into six 3D‐US volumes, each covering the entire phantom, for each of the three different insonation angles. Reconstruction accuracy was evaluated by calculating local distance error (assessment of towers in overlapping US volumes to determine accuracy of stitching) and global distance error (subtraction of true measurements in phantom model from corresponding measurements in stitched 3D‐US volumes). A single‐center, cross‐sectional feasibility study was then conducted in women with an uncomplicated second‐to‐third‐trimester singleton pregnancy, with data obtained using standardized ultrasound settings. Multiple 3D PD‐US and grayscale volumes of the placentae were acquired with infrared camera‐tracked coordinates. Volumes were stitched to create a model of placental vasculature, and these were assessed for quality and repeatability of volume measurement.Results: Six entire phantom datasets were reconstructed at each of three insonation angles, giving a total of 18 extended phanom datasets. A median of nine 3D‐US volumes required to reconstruct the entire phantom. Twelve towers per volume were assessed on three separate occasions, generating 648 datapoints. Of these datapoints, 67.1% were perfectly aligned. The mean local distance error was 2.92 (range, 0–25.51) mm. Measurements between towers of 120 distances in each stitched 3D‐US volume (2160 distances in total) differed by an average of 1.51 (range, −4.78 to 4.23) mm from the true measurements in the phantom model. In the feasibility study, 17 participants were scanned, and 49 3D‐US volume datasets acquired, with 92% reconstruction success per placental volume set and at least one complete volume being obtained per participant (100% participant achievability). The median volume acquisition and reconstruction time was 10 min. Reconstructed placental vasculature was assessed qualitatively to be present, continuous and detailed throughout. Volume measurement of entire segmented placentae was highly repeatable (intraclass correlation coefficient, 0.96 (95% CI, 0.89–0.99)).Conclusion: We present an automated method to model the entire structure and vasculature of second‐to‐third‐trimester placentae using multiple 3D PD‐US volumes, with verified accuracy and clinical feasibility. This study builds a foundation on which to develop a practical screening tool for detecting placental insufficiency and has the potential for expansion to evaluation of adult organ perfusion. © 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 11 February 2025
- Published by Health Education and Training Institute - HETI in Health Education in Practice: Journal of Research for Professional Learning
- Vol. 8 (1)
Emotion and learning influence the learning landscape in sonography
Introduction: Ultrasound is a rapidly expanding field that requires sonographers to continually update their skills through peer learning for optimal patient care. The exchange of skills between learner and teacher involves the cognitive, psychomotor and affective domains, which form a ‘learning landscape’. Significant literature is available regarding the first two of these, but the integration of affective skills (emotion and communication) is often overlooked. Feedback and feedback literacy are also factors contributing to and developing from the interaction. Therefore, our aim was to expand on our previous work to understand how the learning landscape and role of feedback impact Australian sonographers performing complex arteriovenous fistula (AVF) ultrasound examinations. Methods: As previously reported, 50 surveys and 16 semi-structured interviews with Australian sonographers on their experience learning a new, complex ultrasound study (AVF) were linked, to report further in-depth findings of their learning experience and the effects of the learning landscape. Recruitment occurred via an Australian professional association. After transcribing the interviews, thematic analysis was conducted and integrated with the survey data. Results: The combination of survey and interview data allowed the investigation of self-reported levels of competency and confidence, and how this aligned with learners’ subsequent positive and/or negative attitudes towards performing the new study, demonstrating both the influence of the support provided in the initial learning landscape, and the role of feedback / feedback literacy in consequent attitudes to towards the new skill. Conclusion: The learning landscape significantly influences how learners perceive taught skills and process acquired knowledge. The importance of pedagogical support and resources for both peers and learners, in the areas of the affective domain and feedback literacy, is imperative in peer learning situations to optimise the learning experience.
- 11 February 2025
- Published by Health Education and Training Institute - HETI in Health Education in Practice: Journal of Research for Professional Learning
- Vol. 8 (1)
Open AccessEmotion and learning influence the learning landscape in sonography
Introduction: Ultrasound is a rapidly expanding field that requires sonographers to continually update their skills through peer learning for optimal patient care. The exchange of skills between learner and teacher involves the cognitive, psychomotor and affective domains, which form a ‘learning landscape’. Significant literature is available regarding the first two of these, but the integration of affective skills (emotion and communication) is often overlooked. Feedback and feedback literacy are also factors contributing to and developing from the interaction. Therefore, our aim was to expand on our previous work to understand how the learning landscape and role of feedback impact Australian sonographers performing complex arteriovenous fistula (AVF) ultrasound examinations. Methods: As previously reported, 50 surveys and 16 semi-structured interviews with Australian sonographers on their experience learning a new, complex ultrasound study (AVF) were linked, to report further in-depth findings of their learning experience and the effects of the learning landscape. Recruitment occurred via an Australian professional association. After transcribing the interviews, thematic analysis was conducted and integrated with the survey data. Results: The combination of survey and interview data allowed the investigation of self-reported levels of competency and confidence, and how this aligned with learners’ subsequent positive and/or negative attitudes towards performing the new study, demonstrating both the influence of the support provided in the initial learning landscape, and the role of feedback / feedback literacy in consequent attitudes to towards the new skill. Conclusion: The learning landscape significantly influences how learners perceive taught skills and process acquired knowledge. The importance of pedagogical support and resources for both peers and learners, in the areas of the affective domain and feedback literacy, is imperative in peer learning situations to optimise the learning experience.
- 9 January 2024
- Published by SAGE Publications in Ultrasound
- Vol. 32 (2) , 103-113
Does matrix transducer technology improve quality and repeatability of four-dimensional tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements?
Background: Novel ultrasound technology and software processing allow offline evaluation of tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements. We wished to compare both novel 4D matrix (eM6C) and conventional (RAB6-D) transducers with variable settings (electronic spatiotemporal image correlation, spatiotemporal image correlation and four-dimensional real time) to determine if there was a significant difference in absolute value, quality and repeatability of the resultant reconstructed image and M-mode trace. Methods: A blinded prospective cross-sectional study of normal fetuses from 23 to 38 weeks’ gestation were recruited. After routine sonography, four-dimensional volumes were stored and analysed using GE 4DView™ software. Statistical analysis explored variability, correlations and repeatability of the measurements with chi-square analysis, intraclass correlations and the Bland–Altman comparison plots. A scoring system was devised for image quality. Results: Eighteen participants generated 282 data volumes. Absolute values demonstrated some inconsistencies for both tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements with variations between transducers: the highest for the RAB6-D/spatiotemporal image correlation setting and the lowest for the four-dimensional real-time settings. The RAB6-D/spatiotemporal image correlation setting was the most repeatable combination (intraclass correlation coefficient = 0.85). Poorest image quality (M-mode trace, four-chamber view, annuli) came from the RAB6-D/four-dimensional real-time combination with the eM6C/electronic spatiotemporal image correlation and RAB6-D/spatiotemporal image correlation settings being nearly identical. Conclusion: We show that transducer and setting combinations influence absolute tricuspid annular plane systolic excursion/mitral annular plane systolic excursion measurements, so need to be articulated in future research. The transducer setting (electronic spatiotemporal image correlation/spatiotemporal image correlation/four-dimensional real time) was a more significant factor than the type of transducer (conventional vs matrix). Subjective image evaluation does not correlate well with repeatability of image acquisition. Further studies are needed to compare measurements using four-dimensional post-processing tools against conventional real-time measurements.
- 9 January 2024
- Published by SAGE Publications in Ultrasound
- Vol. 32 (2) , 103-113
Does matrix transducer technology improve quality and repeatability of four-dimensional tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements?
Background: Novel ultrasound technology and software processing allow offline evaluation of tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements. We wished to compare both novel 4D matrix (eM6C) and conventional (RAB6-D) transducers with variable settings (electronic spatiotemporal image correlation, spatiotemporal image correlation and four-dimensional real time) to determine if there was a significant difference in absolute value, quality and repeatability of the resultant reconstructed image and M-mode trace. Methods: A blinded prospective cross-sectional study of normal fetuses from 23 to 38 weeks’ gestation were recruited. After routine sonography, four-dimensional volumes were stored and analysed using GE 4DView™ software. Statistical analysis explored variability, correlations and repeatability of the measurements with chi-square analysis, intraclass correlations and the Bland–Altman comparison plots. A scoring system was devised for image quality. Results: Eighteen participants generated 282 data volumes. Absolute values demonstrated some inconsistencies for both tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements with variations between transducers: the highest for the RAB6-D/spatiotemporal image correlation setting and the lowest for the four-dimensional real-time settings. The RAB6-D/spatiotemporal image correlation setting was the most repeatable combination (intraclass correlation coefficient = 0.85). Poorest image quality (M-mode trace, four-chamber view, annuli) came from the RAB6-D/four-dimensional real-time combination with the eM6C/electronic spatiotemporal image correlation and RAB6-D/spatiotemporal image correlation settings being nearly identical. Conclusion: We show that transducer and setting combinations influence absolute tricuspid annular plane systolic excursion/mitral annular plane systolic excursion measurements, so need to be articulated in future research. The transducer setting (electronic spatiotemporal image correlation/spatiotemporal image correlation/four-dimensional real time) was a more significant factor than the type of transducer (conventional vs matrix). Subjective image evaluation does not correlate well with repeatability of image acquisition. Further studies are needed to compare measurements using four-dimensional post-processing tools against conventional real-time measurements.
- 29 September 2021
- Published by Wiley in Sonography
- Vol. 9 (1) , 16-22
Ultrasound of dialysis fistulae: Factors influencing Australian practice
- 29 September 2021
- Published by Wiley in Sonography
- Vol. 9 (1) , 16-22
Ultrasound of dialysis fistulae: Factors influencing Australian practice
- Open Access
- 4 August 2020
- Published by SAGE Publications in Ultrasound
- Vol. 28 (4) , 235-245
UK consensus guidelines for the delivery of unexpected news in obstetric ultrasound: The ASCKS framework
Studies indicate there is a need to improve the delivery of unexpected news via obstetric ultrasound, but there have been few advances in this area. One factor preventing improvement has been a lack of consensus regarding the appropriate phrases and behaviours which sonographers and ultrasound practitioners should use in these situations. To develop consensus guidelines for unexpected news delivery in Early Pregnancy Unit and Fetal Anomaly Screening Programme NHS settings. A workshop was conducted to identify priorities and reach consensus on areas of contention. Contributors included interdisciplinary healthcare professionals, policy experts, representatives from third-sector organisations, lay experts and academic researchers (n = 28). Written and verbal feedback was used to draft initial guidance which was then circulated amongst the wider writing group (n = 39). Revisions were undertaken until consensus was reached. Consensus guidelines were developed outlining the behaviours and phrases which should be used during scans where unexpected findings are identified. Specific recommendations included that: honest and clear communication should be prioritised, even with uncertain findings; technical terms should be used, but these should be written down together with their lay interpretations; unless expectant parents use other terminology (e.g. ‘foetus’), the term ‘baby’ should be used as a default, even in early pregnancy; at the initial news disclosure, communication should focus on information provision. Expectant parents should not be asked to make decisions during the scan. These recommendations can be used to develop and improve news delivery interventions in obstetric ultrasound settings. The full guidelines can be accessed online as supplemental material and at https://doi.org/10.5518/100/24.
- 4 August 2020
- Published by SAGE Publications in Ultrasound
- Vol. 28 (4) , 235-245
Open AccessUK consensus guidelines for the delivery of unexpected news in obstetric ultrasound: The ASCKS framework
Studies indicate there is a need to improve the delivery of unexpected news via obstetric ultrasound, but there have been few advances in this area. One factor preventing improvement has been a lack of consensus regarding the appropriate phrases and behaviours which sonographers and ultrasound practitioners should use in these situations. To develop consensus guidelines for unexpected news delivery in Early Pregnancy Unit and Fetal Anomaly Screening Programme NHS settings. A workshop was conducted to identify priorities and reach consensus on areas of contention. Contributors included interdisciplinary healthcare professionals, policy experts, representatives from third-sector organisations, lay experts and academic researchers (n = 28). Written and verbal feedback was used to draft initial guidance which was then circulated amongst the wider writing group (n = 39). Revisions were undertaken until consensus was reached. Consensus guidelines were developed outlining the behaviours and phrases which should be used during scans where unexpected findings are identified. Specific recommendations included that: honest and clear communication should be prioritised, even with uncertain findings; technical terms should be used, but these should be written down together with their lay interpretations; unless expectant parents use other terminology (e.g. ‘foetus’), the term ‘baby’ should be used as a default, even in early pregnancy; at the initial news disclosure, communication should focus on information provision. Expectant parents should not be asked to make decisions during the scan. These recommendations can be used to develop and improve news delivery interventions in obstetric ultrasound settings. The full guidelines can be accessed online as supplemental material and at https://doi.org/10.5518/100/24.
- 9 June 2020
- Published by SAGE Publications in Ultrasound
- Vol. 28 (3) , 136-144
Sonographers’ level of autonomy in communication in Australian obstetric settings: Does it affect their professional identity?
Introduction: Unlike the United Kingdom, policies in Australia prevent sonographers from exercising autonomy in their level of communication with pregnant patients in the event of adverse findings. The organisational structure makes the sonographer dependent on the sonologist because sonographers do not have the authority to provide the official report. The emotional labour on sonographers is increased as they struggle to provide patient-centred care, given the limits put on their communication during the ultrasound examination. The aim of this study was to explore Australian sonographers’ views on communicating adverse findings, including their level of autonomy in communicating with patients and how this influences their sense of professional identity. Methods: Following a national survey, seven purposively selected participants, who were qualified to perform obstetric ultrasound examinations, completed follow-up interviews. The interviews were thematically analysed with iterative comparison to the survey results. Three case studies show sonographers differed in their ‘communicator type’ due to geographical location and workplace setting. Results: The case studies illustrate a sonographer’s communication role, and level of autonomy is negotiated/renegotiated depending on the needs and expectations of each workplace. Their communication practices varied due to the sonologist (radiologist/obstetrician) policy on sonographer/patient communication, presence and support in the clinical setting. A strong professional identity and level of autonomy came from the construction of attributes that were built over time based on multiple factors, including previous experience, geographical location, critical incidents, training and supportive work environments. Conclusion: The sonography profession demands autonomy and a strong professional identity free of hierarchical barriers within a collaborative model of care.
- 9 June 2020
- Published by SAGE Publications in Ultrasound
- Vol. 28 (3) , 136-144
Sonographers’ level of autonomy in communication in Australian obstetric settings: Does it affect their professional identity?
Introduction: Unlike the United Kingdom, policies in Australia prevent sonographers from exercising autonomy in their level of communication with pregnant patients in the event of adverse findings. The organisational structure makes the sonographer dependent on the sonologist because sonographers do not have the authority to provide the official report. The emotional labour on sonographers is increased as they struggle to provide patient-centred care, given the limits put on their communication during the ultrasound examination. The aim of this study was to explore Australian sonographers’ views on communicating adverse findings, including their level of autonomy in communicating with patients and how this influences their sense of professional identity. Methods: Following a national survey, seven purposively selected participants, who were qualified to perform obstetric ultrasound examinations, completed follow-up interviews. The interviews were thematically analysed with iterative comparison to the survey results. Three case studies show sonographers differed in their ‘communicator type’ due to geographical location and workplace setting. Results: The case studies illustrate a sonographer’s communication role, and level of autonomy is negotiated/renegotiated depending on the needs and expectations of each workplace. Their communication practices varied due to the sonologist (radiologist/obstetrician) policy on sonographer/patient communication, presence and support in the clinical setting. A strong professional identity and level of autonomy came from the construction of attributes that were built over time based on multiple factors, including previous experience, geographical location, critical incidents, training and supportive work environments. Conclusion: The sonography profession demands autonomy and a strong professional identity free of hierarchical barriers within a collaborative model of care.
- 28 February 2020
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 36 (3) , 199-209
Factors that Influence the Communication of Adverse Findings in Obstetrics: A Survey of Current Sonographer Practices in Australia
Objective: To identify factors influencing sonographers’ practices in communicating adverse obstetric findings and to understand their views on the need for standardized national policies and guidelines. Methods: Qualified and trainee sonographers who currently perform obstetric sonography were invited to complete a survey through the Australasian Sonographers Association. Closed-ended questions sought information on the demographic profile of the participants and their experiences on a range of issues related to workplace practices and policies. Open-ended questions allowed respondents to elaborate on workplace interactions and their views on the communication roles of sonologists (radiologists and obstetricians) and sonographers. Results: The practice setting, the background of the sonologist, the type of adverse finding, and the trimester in which a patient is scanned have an impact on the level of difficulty for sonographers in obstetric communication. These findings highlight a lack of uniformity of sonographer and sonologist communication with patients due to limited training, lack of formalized departmental policies, inadequate support, and communication practices by radiologists. As a result, respondents strongly supported the development of a standardized national policy. Conclusion: In the current environment of patient-centered care, sonographers are in a challenging position as they do not have policies supporting them as independent health care professionals, autonomously deciding on the best approach to communicate findings with their patients. This may lead to anxiety and stress if they lack control over the interaction. More support from sonologists in a radiology setting is needed. These findings should encourage professional bodies to address these issues by working collaboratively and to recognize the importance of the sonographers’ role and their unique position with pregnant patients.
- 28 February 2020
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 36 (3) , 199-209
Factors that Influence the Communication of Adverse Findings in Obstetrics: A Survey of Current Sonographer Practices in Australia
Objective: To identify factors influencing sonographers’ practices in communicating adverse obstetric findings and to understand their views on the need for standardized national policies and guidelines. Methods: Qualified and trainee sonographers who currently perform obstetric sonography were invited to complete a survey through the Australasian Sonographers Association. Closed-ended questions sought information on the demographic profile of the participants and their experiences on a range of issues related to workplace practices and policies. Open-ended questions allowed respondents to elaborate on workplace interactions and their views on the communication roles of sonologists (radiologists and obstetricians) and sonographers. Results: The practice setting, the background of the sonologist, the type of adverse finding, and the trimester in which a patient is scanned have an impact on the level of difficulty for sonographers in obstetric communication. These findings highlight a lack of uniformity of sonographer and sonologist communication with patients due to limited training, lack of formalized departmental policies, inadequate support, and communication practices by radiologists. As a result, respondents strongly supported the development of a standardized national policy. Conclusion: In the current environment of patient-centered care, sonographers are in a challenging position as they do not have policies supporting them as independent health care professionals, autonomously deciding on the best approach to communicate findings with their patients. This may lead to anxiety and stress if they lack control over the interaction. More support from sonologists in a radiology setting is needed. These findings should encourage professional bodies to address these issues by working collaboratively and to recognize the importance of the sonographers’ role and their unique position with pregnant patients.
- 2 November 2019
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 23 (2) , 129-139
Sonographers’ communication in obstetrics: Challenges to their professional role and practice in Australia
Introduction/Purpose: Despite the clinical importance of patient‐centred care in the sonographer/patient interaction in obstetric ultrasound, there has been very little current research in Australia on sonographer and sonologist communication practices in the event of an adverse finding. This study sought the views, experiences and practices of Australian sonographers, particularly in relation to adverse findings, with consideration of the implications for their professional role and practice.Methods: Qualified and trainee sonographers who perform obstetric ultrasound were invited to complete a survey through the Australasian Sonographers Association. Using qualitative methodology, the authors developed themes on a range of issues related to sonographer and sonologist communication practices and roles from responses to three open‐ended questions within the survey.Result: Analysis of 249 responses revealed three distinct ‘Communicator types’. ‘Open Communicators’ confidently practice open and direct communication; ‘Limited Communicators’ perceived barriers preventing them from openly communicating; ‘Variable Communicators’ indicated various challenging ‘grey areas’ which created inconsistent communication practices. Variables, such as the complexity of an adverse finding and a reporting sonologist's role, attitude and level of control they exercised over sonographer communication, all influenced respondents’ communication practices. Respondents believed professional bodies should agree on a standardised policy regarding sonographers’ roles.Discussion: This paper highlights the complexity of the sonographer/patient interaction and outlines the difficulty in providing true patient‐centred care in obstetric ultrasound.Conclusion: The need for a collaborative, patient‐focussed policy, which defines and recognises the role of the sonographer in the event of obstetric adverse findings, will improve the current model of care.
- 2 November 2019
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 23 (2) , 129-139
Sonographers’ communication in obstetrics: Challenges to their professional role and practice in Australia
Introduction/Purpose: Despite the clinical importance of patient‐centred care in the sonographer/patient interaction in obstetric ultrasound, there has been very little current research in Australia on sonographer and sonologist communication practices in the event of an adverse finding. This study sought the views, experiences and practices of Australian sonographers, particularly in relation to adverse findings, with consideration of the implications for their professional role and practice.Methods: Qualified and trainee sonographers who perform obstetric ultrasound were invited to complete a survey through the Australasian Sonographers Association. Using qualitative methodology, the authors developed themes on a range of issues related to sonographer and sonologist communication practices and roles from responses to three open‐ended questions within the survey.Result: Analysis of 249 responses revealed three distinct ‘Communicator types’. ‘Open Communicators’ confidently practice open and direct communication; ‘Limited Communicators’ perceived barriers preventing them from openly communicating; ‘Variable Communicators’ indicated various challenging ‘grey areas’ which created inconsistent communication practices. Variables, such as the complexity of an adverse finding and a reporting sonologist's role, attitude and level of control they exercised over sonographer communication, all influenced respondents’ communication practices. Respondents believed professional bodies should agree on a standardised policy regarding sonographers’ roles.Discussion: This paper highlights the complexity of the sonographer/patient interaction and outlines the difficulty in providing true patient‐centred care in obstetric ultrasound.Conclusion: The need for a collaborative, patient‐focussed policy, which defines and recognises the role of the sonographer in the event of obstetric adverse findings, will improve the current model of care.