Edxon Eduardo Licón Bernal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Edxon Eduardo Licón Bernal has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Andriy Yaroshchuk
ICREA, pg.L.Companys 23, 08010 Barcelona, Spain
8 shared publications - José Luis Cortina
Chemical Engineering Department, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC)-Barcelona TECH, Campus Diagonal-Besòs, 08930 Barcelona, Spain
6 shared publications - César Valderrama
Chemical Engineering Department, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC)-BarcelonaTECH, C/Eduard Maristany 10-14, Campus Diagonal-Besòs, 08930 Barcelona, Spain
3 shared publications E. K. Zholkovskiy
National Academy of Sciences of Ukraine
2 shared publications- Mònica Reig
Chemical Engineering Department, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC)-Barcelona TECH, Campus Diagonal-Besòs, 08930 Barcelona, Spain
2 shared publications Oriol Gibert
2 shared publications
Latest Publications
- Open Access
Integration of Membrane Contactors and Bioelectrochemical Systems for CO2 Conversion to CH4
Anaerobic digestion of sewage sludge produces large amounts of CO2 which contribute to global CO2 emissions. Capture and conversion of CO2 into valuable products is a novel way to reduce CO2 emissions and valorize it. Membrane contactors can be used for CO2 capture in liquid media, while bioelectrochemical systems (BES) can valorize dissolved CO2 converting it to CH4, through electromethanogenesis (EMG). At the same time, EMG process, which requires electricity to drive the conversion, can be utilized to store electrical energy (eventually coming from renewables surplus) as methane. The study aims integrating the two technologies at a laboratory scale, using for the first time real wastewater as CO2 capture medium. Five replicate EMG-BES cells were built and operated individually at 0.7 V. They were fed with both synthetic and real wastewater, saturated with CO2 by membrane contactors. In a subsequent experimental step, four EMG-BES cells were electrical stacked in series while one was kept as reference. CH4 production reached 4.6 L CH4 m−2 d−1, in line with available literature data, at a specific energy consumption of 16–18 kWh m−3 CH4 (65% energy efficiency). Organic matter was removed from wastewater at approximately 80% efficiency. CO2 conversion efficiency was limited (0.3–3.7%), depending on the amount of CO2 injected in wastewater. Even though achieved performances are not yet competitive with other mature methanation technologies, key knowledge was gained on the integrated operation of membrane contactors and EMG-BES cells, setting the base for upscaling and future implementation of the technology.
Open AccessIntegration of Membrane Contactors and Bioelectrochemical Systems for CO2 Conversion to CH4
Anaerobic digestion of sewage sludge produces large amounts of CO2 which contribute to global CO2 emissions. Capture and conversion of CO2 into valuable products is a novel way to reduce CO2 emissions and valorize it. Membrane contactors can be used for CO2 capture in liquid media, while bioelectrochemical systems (BES) can valorize dissolved CO2 converting it to CH4, through electromethanogenesis (EMG). At the same time, EMG process, which requires electricity to drive the conversion, can be utilized to store electrical energy (eventually coming from renewables surplus) as methane. The study aims integrating the two technologies at a laboratory scale, using for the first time real wastewater as CO2 capture medium. Five replicate EMG-BES cells were built and operated individually at 0.7 V. They were fed with both synthetic and real wastewater, saturated with CO2 by membrane contactors. In a subsequent experimental step, four EMG-BES cells were electrical stacked in series while one was kept as reference. CH4 production reached 4.6 L CH4 m−2 d−1, in line with available literature data, at a specific energy consumption of 16–18 kWh m−3 CH4 (65% energy efficiency). Organic matter was removed from wastewater at approximately 80% efficiency. CO2 conversion efficiency was limited (0.3–3.7%), depending on the amount of CO2 injected in wastewater. Even though achieved performances are not yet competitive with other mature methanation technologies, key knowledge was gained on the integrated operation of membrane contactors and EMG-BES cells, setting the base for upscaling and future implementation of the technology.
- 1 April 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 584-585, 244-251
Recovery of ammonia from domestic wastewater effluents as liquid fertilizers by integration of natural zeolites and hollow fibre membrane contactors
- 1 April 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 584-585, 244-251
Recovery of ammonia from domestic wastewater effluents as liquid fertilizers by integration of natural zeolites and hollow fibre membrane contactors
- Open Access
- 1 December 2016
- Published by Elsevier in Journal of Membrane Science
- Vol. 520, 693-698
Implications of inhomogeneous distribution of concentration polarization for interpretation of pressure-driven membrane measurements
- 1 December 2016
- Published by Elsevier in Journal of Membrane Science
- Vol. 520, 693-698
Open AccessImplications of inhomogeneous distribution of concentration polarization for interpretation of pressure-driven membrane measurements
- Open Access
- 1 November 2016
- Published by Elsevier in Chemical Engineering Journal
- Vol. 303, 401-408
Rejection of ammonium and nitrate from sodium chloride solutions by nanofiltration: Effect of dominant-salt concentration on the trace-ion rejection
- 1 November 2016
- Published by Elsevier in Chemical Engineering Journal
- Vol. 303, 401-408
Open AccessRejection of ammonium and nitrate from sodium chloride solutions by nanofiltration: Effect of dominant-salt concentration on the trace-ion rejection
- 1 October 2016
- Published by Elsevier in Chemical Engineering Journal
- Vol. 302, 641-649
Valorization of ammonia concentrates from treated urban wastewater using liquid–liquid membrane contactors
- 1 October 2016
- Published by Elsevier in Chemical Engineering Journal
- Vol. 302, 641-649
Valorization of ammonia concentrates from treated urban wastewater using liquid–liquid membrane contactors
- Open Access
- 19 March 2016
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 20 (4) , 58
Hydrodynamic dispersion in long microchannels under conditions of electroosmotic circulation: II. Electrolytes
- 19 March 2016
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 20 (4) , 58
Open AccessHydrodynamic dispersion in long microchannels under conditions of electroosmotic circulation: II. Electrolytes
- 11 February 2016
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 91 (12) , 2983-2993
Trace ammonium removal by liquid–liquid membrane contactors as water polishing step of water electrolysis for hydrogen production from a wastewater treatment plant effluent
BACKGROUND: This work evaluates hollow fiber liquid–liquid membrane contactors (HFMC) as a polishing step for the removal of low levels of ammonium from water purified by (or being supplied to) a membrane distillation unit in order to fulfil the conductivity requirements of hydrogen production by water electrolysis.RESULTS: The influence of the operating conditions (flow, pH, ammonium concentration, buffer capacity) were evaluated under a closed‐loop setup in order to achieve a reduction of total ammonia concentration in water, from 15 to 1 mg L−1 to assure the production of water in the membrane distillation with a conductivity lower than 1 µS cm−1. These values were used to validate a numerical algorithm describing the system performance. In order to reach the ammonia concentration requirements and considering the low concentration of bicarbonate (low pH buffer capacity) in the treated water a buffer agent was added to the working solution.CONCLUSIONS: HFMC technology is a suitable solution to remove low levels of ammonium from water to values as low as 1 mg L−1NH3 through appropriate control of pH. The ammonium removal efficiency of the HFMC was improved by raising the pH or the flow rate. Finally, the model proposed provides a good description of the membrane contactor performance with minimal deviations when compared with experimental results. © 2016 Society of Chemical Industry
- 11 February 2016
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 91 (12) , 2983-2993
Trace ammonium removal by liquid–liquid membrane contactors as water polishing step of water electrolysis for hydrogen production from a wastewater treatment plant effluent
BACKGROUND: This work evaluates hollow fiber liquid–liquid membrane contactors (HFMC) as a polishing step for the removal of low levels of ammonium from water purified by (or being supplied to) a membrane distillation unit in order to fulfil the conductivity requirements of hydrogen production by water electrolysis.RESULTS: The influence of the operating conditions (flow, pH, ammonium concentration, buffer capacity) were evaluated under a closed‐loop setup in order to achieve a reduction of total ammonia concentration in water, from 15 to 1 mg L−1 to assure the production of water in the membrane distillation with a conductivity lower than 1 µS cm−1. These values were used to validate a numerical algorithm describing the system performance. In order to reach the ammonia concentration requirements and considering the low concentration of bicarbonate (low pH buffer capacity) in the treated water a buffer agent was added to the working solution.CONCLUSIONS: HFMC technology is a suitable solution to remove low levels of ammonium from water to values as low as 1 mg L−1NH3 through appropriate control of pH. The ammonium removal efficiency of the HFMC was improved by raising the pH or the flow rate. Finally, the model proposed provides a good description of the membrane contactor performance with minimal deviations when compared with experimental results. © 2016 Society of Chemical Industry
- Open Access
- 1 December 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3519-3529
Evolution of electrolyte mixtures rejection behaviour using nanofiltration membranes under spiral wound and flat-sheet configurations
Nanofiltration (NF) membranes can be used in different configurations. The aim of this work was to determine the reliability of the data obtained using flat-sheet (FS) laboratory-scale configuration when NF membranes are implemented at industrial scale level using spiral wound (SW) configuration. Ion rejections in salt mixtures with the two configurations types were analysed, modelled, evaluated and compared. In both cases of the study, the operation was carried out in cross-flow mode and with recirculation of permeate and concentrate streams into the feed tank. Different feed synthetic salt solutions were used based on a dominant and a trace salt. In both cases, the operating temperature was kept constant (21.5 ± 2.5°C), and the trans-membrane pressure range varied from the osmotic pressure to 20 bar. The same NF membrane was used for both configurations: NF270 (Dow Chemical). The solution–diffusion–electromigration–film model was employed to describe the experimental results. Comparing both membrane configurations, the trans-membrane flux obtained with the FS configuration was higher than that observed with the SW configuration under the same operating conditions. In general, it is proved that ion rejection curves for both membrane configurations were fairly similar. Moreover, the membrane permeances with respect to each ion in both configurations were quantitatively similar.
- 1 December 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3519-3529
Open AccessEvolution of electrolyte mixtures rejection behaviour using nanofiltration membranes under spiral wound and flat-sheet configurations
Nanofiltration (NF) membranes can be used in different configurations. The aim of this work was to determine the reliability of the data obtained using flat-sheet (FS) laboratory-scale configuration when NF membranes are implemented at industrial scale level using spiral wound (SW) configuration. Ion rejections in salt mixtures with the two configurations types were analysed, modelled, evaluated and compared. In both cases of the study, the operation was carried out in cross-flow mode and with recirculation of permeate and concentrate streams into the feed tank. Different feed synthetic salt solutions were used based on a dominant and a trace salt. In both cases, the operating temperature was kept constant (21.5 ± 2.5°C), and the trans-membrane pressure range varied from the osmotic pressure to 20 bar. The same NF membrane was used for both configurations: NF270 (Dow Chemical). The solution–diffusion–electromigration–film model was employed to describe the experimental results. Comparing both membrane configurations, the trans-membrane flux obtained with the FS configuration was higher than that observed with the SW configuration under the same operating conditions. In general, it is proved that ion rejection curves for both membrane configurations were fairly similar. Moreover, the membrane permeances with respect to each ion in both configurations were quantitatively similar.
- Open Access
- 1 December 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3607-3616
Ammonium removal by liquid–liquid membrane contactors in water purification process for hydrogen production
© 2014 Balaban Desalination Publications. All rights reserved.\ud In this work, a liquid–liquid membrane contactor (LLMC) was evaluated to remove ammonia traces from water used for hydrogen production by electrolysis. Three operational parameters were evaluated: the feed flow rate, the initial ammonia concentration in the water stream, and the pH of solution. Synthetic aqueous solutions with ammonium concentration of 5–25 mg L-1 and a sulfuric acid solution (pH 2) were supplied to the LLMC in countercurrent and open-loop configuration with flow rates between 2.72 × 10-6 and 22.6 × 10-6 m3 s-1 and the pH values of the solution with ammonium between 8 and 11. A 2D numerical model was developed considering advection–diffusion equation inside a single fiber of the lumen with fully developed laminar flow and liquid–gas equilibrium in the membrane–solution interface. Predictions of the model were then validated against experimental data, which were found to be in good agreement. According to both, experimental data and numerical predictions, the hollow-fiber membrane contactor technology is a suitable alternative to remove ammonium from water and to feed the membrane distillation unit in order to fulfill water quality requirements for electrolysis-based hydrogen production.Peer ReviewedPostprint (author's final draft
- 1 December 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (13) , 3607-3616
Open AccessAmmonium removal by liquid–liquid membrane contactors in water purification process for hydrogen production
© 2014 Balaban Desalination Publications. All rights reserved.\ud In this work, a liquid–liquid membrane contactor (LLMC) was evaluated to remove ammonia traces from water used for hydrogen production by electrolysis. Three operational parameters were evaluated: the feed flow rate, the initial ammonia concentration in the water stream, and the pH of solution. Synthetic aqueous solutions with ammonium concentration of 5–25 mg L-1 and a sulfuric acid solution (pH 2) were supplied to the LLMC in countercurrent and open-loop configuration with flow rates between 2.72 × 10-6 and 22.6 × 10-6 m3 s-1 and the pH values of the solution with ammonium between 8 and 11. A 2D numerical model was developed considering advection–diffusion equation inside a single fiber of the lumen with fully developed laminar flow and liquid–gas equilibrium in the membrane–solution interface. Predictions of the model were then validated against experimental data, which were found to be in good agreement. According to both, experimental data and numerical predictions, the hollow-fiber membrane contactor technology is a suitable alternative to remove ammonium from water and to feed the membrane distillation unit in order to fulfill water quality requirements for electrolysis-based hydrogen production.Peer ReviewedPostprint (author's final draft
- 29 October 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 18 (5-6) , 1139-1154
Hydrodynamic dispersion in long microchannels under conditions of electroosmotic circulation. I. Non-electrolytes
- 29 October 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 18 (5-6) , 1139-1154
Hydrodynamic dispersion in long microchannels under conditions of electroosmotic circulation. I. Non-electrolytes