D. Jed Harrison
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
D. Jed Harrison has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Abebaw B. Jemere
National Institute for Nanotechnology, NRC, Edmonton, Alberta, Canada
9 shared publicationsYong Zeng
Department of Chemistry, University of Alberta, Edmonton, Alb., Canada
5 shared publicationsJacob H. Masliyah
Department of Chemical and Materials Engineering University of Alberta Alberta Canada
4 shared publicationsMei He
Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
4 shared publicationsSubir Bhattacharjee
Department of Mechanical Engineering University of Alberta Alberta Canada
4 shared publications- Yufeng Zhao
Department of Neurobiology, Stanford University, Stanford, CA 94305, USA
4 shared publications
Latest Publications
- Open Access
- 18 December 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (12) , 2257
An Automated Centrifugal Microfluidic Platform for Efficient Multistep Blood Sample Preparation and Clean-Up towards Small Ion-Molecule Analysis
Sample preparation for mass spectroscopy typically involves several liquid and solid phase clean-ups, extractions, and other unit operations, which are labour-intensive and error-prone. We demonstrate a centrifugal microfluidic platform that automates the whole blood sample’s preparation and clean-up by combining traditional liquid-phase and multiple solid-phase extractions for applications in mass spectroscopy (MS)-based small molecule detection. Liquid phase extraction was performed using methanol to precipitate proteins in plasma separated from a blood sample under centrifugal force. The preloaded solid phase composed of C18 beads then removed lipids with a combination of silica particles, which further cleaned up any remaining proteins. We further integrated the application of this sample prep disc with matrix-assisted laser desorption/ionization (MALDI) MS by using glancing angle deposition films, which further cleaned up the processed sample by segregating the electrolyte background from the sample salts. Additionally, hydrophilic interaction liquid chromatography (HILIC) MS was employed for detecting targeted free amino acids. Therefore, several representative ionic metabolites, including several amino acids and organic acids from blood samples, were analysed by both MALDI-MS and HILIC-MS to demonstrate the performance of this sample preparation disc. The fully automated blood sample preparation procedure only took 35 mins, with a throughput of three parallel units.
- 18 December 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (12) , 2257
Open AccessAn Automated Centrifugal Microfluidic Platform for Efficient Multistep Blood Sample Preparation and Clean-Up towards Small Ion-Molecule Analysis
Sample preparation for mass spectroscopy typically involves several liquid and solid phase clean-ups, extractions, and other unit operations, which are labour-intensive and error-prone. We demonstrate a centrifugal microfluidic platform that automates the whole blood sample’s preparation and clean-up by combining traditional liquid-phase and multiple solid-phase extractions for applications in mass spectroscopy (MS)-based small molecule detection. Liquid phase extraction was performed using methanol to precipitate proteins in plasma separated from a blood sample under centrifugal force. The preloaded solid phase composed of C18 beads then removed lipids with a combination of silica particles, which further cleaned up any remaining proteins. We further integrated the application of this sample prep disc with matrix-assisted laser desorption/ionization (MALDI) MS by using glancing angle deposition films, which further cleaned up the processed sample by segregating the electrolyte background from the sample salts. Additionally, hydrophilic interaction liquid chromatography (HILIC) MS was employed for detecting targeted free amino acids. Therefore, several representative ionic metabolites, including several amino acids and organic acids from blood samples, were analysed by both MALDI-MS and HILIC-MS to demonstrate the performance of this sample preparation disc. The fully automated blood sample preparation procedure only took 35 mins, with a throughput of three parallel units.
- Open Access
- 5 December 2019
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 4 (25) , 21131-21140
Fabrication of Rugged and Reliable Fluidic Chips for Autonomous Environmental Analyzers Using Combined Thermal and Pressure Bonding of Polymethyl Methacrylate Layers
The fabrication of highly reliable and rugged fluidic chips designed for use in autonomous analyses for nutrient monitoring is described. The chips are based on a two-layer configuration with the fluidic channels produced in one layer using precision micromilling. The second capping layer contains through holes for sample/standard and reagent addition and waste removal post-analysis. Two optically clear polymethyl methacrylate (PMMA) windows are integrated into the opaque PMMA chip, orthogonal to a 22.5 mm-long section of the channel downstream from a serpentine reagent and sample/standard mixing region. An LED source is coupled into the channel through one of the windows, and the light intensity is monitored with a photodiode located at the distal end of the channel outside the second optically clear window. Efficient coupling of the source through the channel to the detector is achieved using custom-designed alignment units produced using 3D printing. In contrast to fluidic chips produced using solvent adhesion, the thermal-/pressure-bonded simplified method presented removes the need for surface treatment. Optimization of the thermal/pressure conditions leads to very strong adhesion between the PMMA layers, requiring forces in the region of 2000 N to separate them, which is necessary for the use in long-term deployments. Profilometry imaging shows minimal evidence of channel distortion after bonding. Finally, we show the potential of these techniques for environmental applications. The fluidic chips were integrated into prototype nutrient analyzers that display no evidence of leakage in extensive lab tests involving 2500 phosphate measurements using the yellow (vanadomolybdophosphoric acid) method. Similarly, excellent analytical performance (LOD is 0.09 μM) is reported for a 28-day field trial comprising 188 in situ autonomous phosphate measurements (564 measurements) in total including calibration.
- 5 December 2019
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 4 (25) , 21131-21140
Open AccessFabrication of Rugged and Reliable Fluidic Chips for Autonomous Environmental Analyzers Using Combined Thermal and Pressure Bonding of Polymethyl Methacrylate Layers
The fabrication of highly reliable and rugged fluidic chips designed for use in autonomous analyses for nutrient monitoring is described. The chips are based on a two-layer configuration with the fluidic channels produced in one layer using precision micromilling. The second capping layer contains through holes for sample/standard and reagent addition and waste removal post-analysis. Two optically clear polymethyl methacrylate (PMMA) windows are integrated into the opaque PMMA chip, orthogonal to a 22.5 mm-long section of the channel downstream from a serpentine reagent and sample/standard mixing region. An LED source is coupled into the channel through one of the windows, and the light intensity is monitored with a photodiode located at the distal end of the channel outside the second optically clear window. Efficient coupling of the source through the channel to the detector is achieved using custom-designed alignment units produced using 3D printing. In contrast to fluidic chips produced using solvent adhesion, the thermal-/pressure-bonded simplified method presented removes the need for surface treatment. Optimization of the thermal/pressure conditions leads to very strong adhesion between the PMMA layers, requiring forces in the region of 2000 N to separate them, which is necessary for the use in long-term deployments. Profilometry imaging shows minimal evidence of channel distortion after bonding. Finally, we show the potential of these techniques for environmental applications. The fluidic chips were integrated into prototype nutrient analyzers that display no evidence of leakage in extensive lab tests involving 2500 phosphate measurements using the yellow (vanadomolybdophosphoric acid) method. Similarly, excellent analytical performance (LOD is 0.09 μM) is reported for a 28-day field trial comprising 188 in situ autonomous phosphate measurements (564 measurements) in total including calibration.
- 14 October 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (22) , 3880-3887
A single-phase flow microfluidic cell sorter for multiparameter screening to assist the directed evolution of Ca2+ sensors
We introduce a single-phase flow microfluidic cell sorter with a two-point detection system capable of two-parameter screening to assist with directed evolution of a fluorescent protein based Ca2+ sensor expressed in bacterial cells.
- 14 October 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (22) , 3880-3887
A single-phase flow microfluidic cell sorter for multiparameter screening to assist the directed evolution of Ca2+ sensors
We introduce a single-phase flow microfluidic cell sorter with a two-point detection system capable of two-parameter screening to assist with directed evolution of a fluorescent protein based Ca2+ sensor expressed in bacterial cells.
- 15 May 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (12) , 7570-7577
Sample Preparation in Centrifugal Microfluidic Discs for Human Serum Metabolite Analysis by Surface Assisted Laser Desorption/Ionization Mass Spectrometry
We introduce a centrifugal microfluidic disc that accepts a small volume in (~5 µL), performs sample clean-up on human serum samples, and delivers a small volume out, for subsequent metabolite analysis by surface assisted laser desorption/ionization (SALDI) mass spectrometry (MS) or hydrophilic interaction liquid chromatography (HILIC) MS. The centrifugal microfluidic disc improves the MS results by removing proteins and lipids from serum. In the case of SALDI-MS, sample background electrolytes are segregated from analytes during the spotting process by the action of the SALDI-chip during drying, for further clean-up, while HILIC separates the salts in HILIC-MS. The resulting mass spectra of disc-prepared samples shows a clean background and high signal to noise ratio for metabolite peaks. Several representative ionic metabolites from human serum samples were successfully quantified. The performance of the sample preparation disc for SALDI-MS and HILIC-MS were assessed and were comparable. Reproducibility, sample bias, and detection limits for SALDI-MS compared well to ultrafiltration sample preparation.
- 15 May 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (12) , 7570-7577
Sample Preparation in Centrifugal Microfluidic Discs for Human Serum Metabolite Analysis by Surface Assisted Laser Desorption/Ionization Mass Spectrometry
We introduce a centrifugal microfluidic disc that accepts a small volume in (~5 µL), performs sample clean-up on human serum samples, and delivers a small volume out, for subsequent metabolite analysis by surface assisted laser desorption/ionization (SALDI) mass spectrometry (MS) or hydrophilic interaction liquid chromatography (HILIC) MS. The centrifugal microfluidic disc improves the MS results by removing proteins and lipids from serum. In the case of SALDI-MS, sample background electrolytes are segregated from analytes during the spotting process by the action of the SALDI-chip during drying, for further clean-up, while HILIC separates the salts in HILIC-MS. The resulting mass spectra of disc-prepared samples shows a clean background and high signal to noise ratio for metabolite peaks. Several representative ionic metabolites from human serum samples were successfully quantified. The performance of the sample preparation disc for SALDI-MS and HILIC-MS were assessed and were comparable. Reproducibility, sample bias, and detection limits for SALDI-MS compared well to ultrafiltration sample preparation.
- Open Access
- 6 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 11758
Inverse-response Ca2+ indicators for optogenetic visualization of neuronal inhibition
We have developed a series of yellow genetically encoded Ca2+ indicators for optical imaging (Y-GECOs) with inverted responses to Ca2+ and apparent dissociation constants (Kd′) ranging from 25 to 2400 nM. To demonstrate the utility of this affinity series of Ca2+ indicators, we expressed the four highest affinity variants (Kd′s = 25, 63, 121, and 190 nM) in the Drosophila medulla intrinsic neuron Mi1. Hyperpolarization of Mi1 by optogenetic stimulation of the laminar monopolar neuron L1 produced a decrease in intracellular Ca2+ in layers 8–10, and a corresponding increase in Y-GECO fluorescence. These experiments revealed that lower Kd′ was associated with greater increases in fluorescence, but longer delays to reach the maximum signal change due to slower off-rate kinetics.
- 6 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 11758
Open AccessInverse-response Ca2+ indicators for optogenetic visualization of neuronal inhibition
We have developed a series of yellow genetically encoded Ca2+ indicators for optical imaging (Y-GECOs) with inverted responses to Ca2+ and apparent dissociation constants (Kd′) ranging from 25 to 2400 nM. To demonstrate the utility of this affinity series of Ca2+ indicators, we expressed the four highest affinity variants (Kd′s = 25, 63, 121, and 190 nM) in the Drosophila medulla intrinsic neuron Mi1. Hyperpolarization of Mi1 by optogenetic stimulation of the laminar monopolar neuron L1 produced a decrease in intracellular Ca2+ in layers 8–10, and a corresponding increase in Y-GECO fluorescence. These experiments revealed that lower Kd′ was associated with greater increases in fluorescence, but longer delays to reach the maximum signal change due to slower off-rate kinetics.
- 3 March 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (6) , 3362-3369
Salt Segregation and Sample Cleanup on Perfluoro-Coated Nanostructured Surfaces for Laser Desorption Ionization Mass Spectrometry of Biofluid Samples
We present a surface assisted laser desorption ionization (SALDI) technique, coupled with fluorocarbon coating, to achieve selective segregation of ionic and/or hydrophilic analytes from background biofluid electrolytes for quantiatve mass spectrometric analysis. By controlling the contact angle of (1H,1H,2H,2H-perfluorooctyl) trichlorosilane or (1H,1H,2H,2H-perfluorooctyl) dimethylchlorosilane to a specific range (105–120°), background electrolytes can be made to segregate from hydrophilic analytes during a drying step on the surface of a highly nanoporous thin film. Nanoporous silicon films were prepared using glancing angle deposition (GLAD) thin film technology, then coated with fluorcarbon. This desalting method directly separates highly polar, ionic metabolites, such as amino acids, from salty biofluids such as aritificial cerebrospinal fluid (aCSF) and serum. Derivatization, extraction and rinsing steps are not required to separate the analytes from the bioelectrolytes. With on-chip desalting, the limit of quantitation for histidine spiked in aCSF is ∼1 μM, and calibration curves with internal standards can achieve a precision of 1–9% within a 1 to 50 μM range. Five highly polar organic acids in serum were successfully quantified, and the SALDI-MS results obtained on the desalted serum sample spots show both good reproducibility and compare well to results from NMR and liquid chromatography–mass spectrometry. Putative identification of a total of 32 metabolites was accomplished in blood using time-of-flight MS with perfluoro coated Si-GLAD SALDI, by comparison to tabulated data.
- 3 March 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (6) , 3362-3369
Salt Segregation and Sample Cleanup on Perfluoro-Coated Nanostructured Surfaces for Laser Desorption Ionization Mass Spectrometry of Biofluid Samples
We present a surface assisted laser desorption ionization (SALDI) technique, coupled with fluorocarbon coating, to achieve selective segregation of ionic and/or hydrophilic analytes from background biofluid electrolytes for quantiatve mass spectrometric analysis. By controlling the contact angle of (1H,1H,2H,2H-perfluorooctyl) trichlorosilane or (1H,1H,2H,2H-perfluorooctyl) dimethylchlorosilane to a specific range (105–120°), background electrolytes can be made to segregate from hydrophilic analytes during a drying step on the surface of a highly nanoporous thin film. Nanoporous silicon films were prepared using glancing angle deposition (GLAD) thin film technology, then coated with fluorcarbon. This desalting method directly separates highly polar, ionic metabolites, such as amino acids, from salty biofluids such as aritificial cerebrospinal fluid (aCSF) and serum. Derivatization, extraction and rinsing steps are not required to separate the analytes from the bioelectrolytes. With on-chip desalting, the limit of quantitation for histidine spiked in aCSF is ∼1 μM, and calibration curves with internal standards can achieve a precision of 1–9% within a 1 to 50 μM range. Five highly polar organic acids in serum were successfully quantified, and the SALDI-MS results obtained on the desalted serum sample spots show both good reproducibility and compare well to results from NMR and liquid chromatography–mass spectrometry. Putative identification of a total of 32 metabolites was accomplished in blood using time-of-flight MS with perfluoro coated Si-GLAD SALDI, by comparison to tabulated data.
- 11 January 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (7) , 631-638
Engineering matrix‐free laser desorption ionization mass spectrometry using glancing angle deposition films
Rationale: Thin, nanoporous films fabricated using Glancing Angle Deposition (GLAD) technology are demonstrated for solid matrix laser desorption/ionization mass spectrometry (SMALDI‐MS). GLAD allows facile engineering of nanoporosity, film thickness, post alignment, and material composition, as demonstrated here by the fabrication of Co‐GLAD and Si‐GLAD films for SMALDI, and by exploration of the SMALDI performance as a function of thickness, post density, and angle of the post relative to surface normal. Methods: GLAD films were prepared by electron beam evaporation onto silicon substrates, using steep angles of incidence for the vacuum deposition, with computer controlled substrate rotation. LDI from the GLAD films was evaluated using an MDS‐Sciex time‐of‐flight (TOF) MALDI mass spectrometer. Results: Co‐GLAD films give a limit of quantitation of 6 fmol for complex carbohydrate derivatives, and slanted‐post Si‐GLAD films show up to three times higher sensitivity than vertical post structures. Reproducibility of both Si and Co films is much higher than conventional MALDI methods for m/z below at least 2100 Da. Both reproducibility and detection limits are comparable to or better than other nano‐structured materials. Co‐GLAD films are significantly better in performance than Co powders or Co thin films on silicon substrates previously evaluated. Conclusions: The flexibility of GLAD for thin film fabrication of LDI materials is demonstrated by the range of nanoporous materials that can be grown, and the fine control over structural conformation, thickness and porosity. Copyright © 2017 John Wiley & Sons, Ltd.
- 11 January 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (7) , 631-638
Engineering matrix‐free laser desorption ionization mass spectrometry using glancing angle deposition films
Rationale: Thin, nanoporous films fabricated using Glancing Angle Deposition (GLAD) technology are demonstrated for solid matrix laser desorption/ionization mass spectrometry (SMALDI‐MS). GLAD allows facile engineering of nanoporosity, film thickness, post alignment, and material composition, as demonstrated here by the fabrication of Co‐GLAD and Si‐GLAD films for SMALDI, and by exploration of the SMALDI performance as a function of thickness, post density, and angle of the post relative to surface normal. Methods: GLAD films were prepared by electron beam evaporation onto silicon substrates, using steep angles of incidence for the vacuum deposition, with computer controlled substrate rotation. LDI from the GLAD films was evaluated using an MDS‐Sciex time‐of‐flight (TOF) MALDI mass spectrometer. Results: Co‐GLAD films give a limit of quantitation of 6 fmol for complex carbohydrate derivatives, and slanted‐post Si‐GLAD films show up to three times higher sensitivity than vertical post structures. Reproducibility of both Si and Co films is much higher than conventional MALDI methods for m/z below at least 2100 Da. Both reproducibility and detection limits are comparable to or better than other nano‐structured materials. Co‐GLAD films are significantly better in performance than Co powders or Co thin films on silicon substrates previously evaluated. Conclusions: The flexibility of GLAD for thin film fabrication of LDI materials is demonstrated by the range of nanoporous materials that can be grown, and the fine control over structural conformation, thickness and porosity. Copyright © 2017 John Wiley & Sons, Ltd.
- 14 November 2016
- Published by Wiley in Electrophoresis
- Vol. 38 (2) , 342-349
Evaluation of protein separation mechanism and pore size distribution in colloidal self‐assembled nanoparticle sieves for on‐chip protein sizing
The separation behavior of 6.5–66 kDa proteins in silica particle array‐based sieves formed by colloidal self‐assembly in microchips is reported across a pore size range of 22–103 nm. The protein separation and resolution improves markedly with decreasing pore size. The variation of electrophoretic mobility with molecular weight of SDS–protein complexes and with particle size was evaluated using the Ogston sieving equation for a random pore gel structure, and using the modified Giddings equation developed by Wirth for uniform pore structures. The Wirth/Giddings equation provides the best fit for estimation of molecular weight of proteins, and demonstrates that even though experimental evidence shows there is some dispersion in measured pore sizes, these structures can best be described as having a uniform pore size.
- 14 November 2016
- Published by Wiley in Electrophoresis
- Vol. 38 (2) , 342-349
Evaluation of protein separation mechanism and pore size distribution in colloidal self‐assembled nanoparticle sieves for on‐chip protein sizing
The separation behavior of 6.5–66 kDa proteins in silica particle array‐based sieves formed by colloidal self‐assembly in microchips is reported across a pore size range of 22–103 nm. The protein separation and resolution improves markedly with decreasing pore size. The variation of electrophoretic mobility with molecular weight of SDS–protein complexes and with particle size was evaluated using the Ogston sieving equation for a random pore gel structure, and using the modified Giddings equation developed by Wirth for uniform pore structures. The Wirth/Giddings equation provides the best fit for estimation of molecular weight of proteins, and demonstrates that even though experimental evidence shows there is some dispersion in measured pore sizes, these structures can best be described as having a uniform pore size.
- 21 July 2016
- Published by Wiley in Electrophoresis
- Vol. 37 (20) , 2602-2609
Size‐based proteins separation using polymer‐entrapped colloidal self‐assembled nanoparticles on‐chip
We report on a facile method to stabilize colloidal self‐assembled (CSA) nanoparticles packed in microchannels for high speed size‐based separation of proteins. Silica nanoparticles, self‐assembled in a network of microfluidic channels, were stabilized with a methacrylate polymer prepared in situ through photopolymerization. The entrapment conditions were investigated to minimize the effect of the polymer matrix on the structure of the packing and the separation properties of the CSA beds. SEM shows that the methacrylate matrix links the nanoparticles at specific sphere–sphere contact points, improving the stability of the CSA structure at high electric fields (up to at least 1800 V/cm), allowing fast and efficient separation. The %RSD of the protein migration times varied between 0.3 and 0.5% (n = 4, in 1 day) and n = 28 runs) in a single device, at high field strength. The overall %RSD of protein migration times from chip‐to‐chip across a single fabrication run was 4.3% (n = 3) and between fabrication runs was 11% (n = 35), with 87% fabrication yield, demonstrating reproducible packing and entrapment behavior. The optimized entrapped CSA beds demonstrated better separation performance (plate height, H ∼ 200 nm) than similarly prepared on‐chip CSA beds without the polymer entrapment. Polymer‐entrapped CSA beds also exhibited superior protein resolving power: the minimum resolvable molecular weight difference of proteins in the polymer‐entrapped CSA bed is 0.6 kDa versus ∼9 kDa for the native silica CSA bed (i.e. without polymer entrapment).
- 21 July 2016
- Published by Wiley in Electrophoresis
- Vol. 37 (20) , 2602-2609
Size‐based proteins separation using polymer‐entrapped colloidal self‐assembled nanoparticles on‐chip
We report on a facile method to stabilize colloidal self‐assembled (CSA) nanoparticles packed in microchannels for high speed size‐based separation of proteins. Silica nanoparticles, self‐assembled in a network of microfluidic channels, were stabilized with a methacrylate polymer prepared in situ through photopolymerization. The entrapment conditions were investigated to minimize the effect of the polymer matrix on the structure of the packing and the separation properties of the CSA beds. SEM shows that the methacrylate matrix links the nanoparticles at specific sphere–sphere contact points, improving the stability of the CSA structure at high electric fields (up to at least 1800 V/cm), allowing fast and efficient separation. The %RSD of the protein migration times varied between 0.3 and 0.5% (n = 4, in 1 day) and n = 28 runs) in a single device, at high field strength. The overall %RSD of protein migration times from chip‐to‐chip across a single fabrication run was 4.3% (n = 3) and between fabrication runs was 11% (n = 35), with 87% fabrication yield, demonstrating reproducible packing and entrapment behavior. The optimized entrapped CSA beds demonstrated better separation performance (plate height, H ∼ 200 nm) than similarly prepared on‐chip CSA beds without the polymer entrapment. Polymer‐entrapped CSA beds also exhibited superior protein resolving power: the minimum resolvable molecular weight difference of proteins in the polymer‐entrapped CSA bed is 0.6 kDa versus ∼9 kDa for the native silica CSA bed (i.e. without polymer entrapment).
- 23 March 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (39) , 8307-8310
DNA strand displacement reaction for programmable release of biomolecules
Sample cleanup is a major processing step in many analytical assays. Here, we propose an approach to capture-and-release of analytes based on the DNA strand displacement reaction (SDR) and demonstrate its application to a fluoroimmunoassay on beads for a thyroid cancer biomarker, thyroglobulin. The SDR-based cleanup showed no interference from matrix molecules in serum.
- 23 March 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (39) , 8307-8310
DNA strand displacement reaction for programmable release of biomolecules
Sample cleanup is a major processing step in many analytical assays. Here, we propose an approach to capture-and-release of analytes based on the DNA strand displacement reaction (SDR) and demonstrate its application to a fluoroimmunoassay on beads for a thyroid cancer biomarker, thyroglobulin. The SDR-based cleanup showed no interference from matrix molecules in serum.