Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Choon Siew Kit has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Metabolic Optimisation in Total Joint Arthroplasty: A Single-Centre Retrospective Cohort Pilot Study on the Safety and Feasibility of a Digitally Supported Perioperative Diet Modification

    by Hwee Wen Ong, Khairul Anwar Ayob, David Siew-Kit Choon, Virginia Hartono

    Background/Objectives: Obesity and type 2 diabetes are increasingly common among patients undergoing hip and knee arthroplasty and are associated with higher risks of prosthetic joint infection, impaired wound healing, and prolonged hospitalisation. Dietary carbohydrate restriction has demonstrated benefits in glycemic control and weight reduction, but its feasibility and safety in the perioperative arthroplasty population remain underexplored. This pilot study evaluated the safety, feasibility, and short-term metabolic effects of a low-carbohydrate diet supported by WhatsApp-based meal photo-logging in patients undergoing total hip or knee arthroplasty. Methods: A retrospective cohort analysis was performed on 43 patients enrolled in a carbohydrate-restricted dietary programme between 2021 and 2024. Patients submitted photographs of all meals via WhatsApp with a minimum contact frequency of four times daily, enabling real-time feedback and medication adjustment. Anthropometric and metabolic parameters, including weight, BMI, HbA1c, renal function, and lipid profile, were assessed before and after the intervention. Results: Participants (mean age 69.12 ± 7.51 years) demonstrated significant improvement across several metabolic markers. Mean weight decreased by 5.74 kg (p < 0.001), BMI by 2.26 kg/m2 (p < 0.001), and HbA1c by 0.72% (p < 0.001). No episodes of severe hypoglycaemia or perioperative discharge delays related to glycemic instability were observed. Renal function remained stable, with no significant change in eGFR (p = 0.442). Among patients with available lipid data (n = 14), LDL-cholesterol and total cholesterol increased, while triglycerides showed a non-significant downward trend. Conclusions: A low-carbohydrate diet combined with high-frequency digital monitoring appears feasible and safe, achieving meaningful short-term improvements in weight and glycemic control without adverse renal or hypoglycemic events. The lipid changes observed, however, warrant cautious interpretation. These findings are hypothesis-generating, and larger prospective studies are needed to confirm the clinical impact of this approach and its relevance to perioperative optimisation.


  • Open Access

    Metabolic Optimization in Total Joint Arthroplasty: A Single-Centre Retrospective Cohort Pilot Study on the Safety and Feasibility of a Digitally Supported Perioperative Diet Modification

    by Hwee Wen Ong, Khairul Anwar bin Ayob, Siew Kit Choon, Virginia Hartono

    Background/Objectives: Obesity and type 2 diabetes are increasingly common among patients undergoing hip and knee arthroplasty and are associated with higher risks of prosthetic joint infection, impaired wound healing, and prolonged hospitalization. Dietary carbohydrate restriction has demonstrated benefits in glycemic control and weight reduction, but its feasibility and safety in the perioperative arthroplasty population remain underexplored. This pilot study evaluated the safety, feasibility, and short-term metabolic effects of a low-carbohydrate diet supported by WhatsApp-based meal photo-logging in patients undergoing total hip or knee arthroplasty. Methods: A retrospective cohort analysis was performed on 43 patients enrolled in a carbohydrate-restricted dietary programme between 2021 and 2024. Patients submitted photographs of all meals via WhatsApp with a minimum contact frequency of four times daily, enabling real-time feedback and medication adjustment. Anthropometric and metabolic parameters, including weight, BMI, HbA1c, renal function, and lipid profile, were assessed before and after the intervention. Results: Participants (mean age 69.12 ± 7.51 years) demonstrated significant improvement across several metabolic markers. Mean weight decreased by 5.74 kg (p < 0.001), BMI by 2.26 kg/m² (p < 0.001), and HbA1c by 0.72% (p < 0.001). No episodes of severe hypoglycemia or perioperative discharge delays related to glycemic instability were observed. Renal function remained stable, with no significant change in eGFR (p = 0.442). Among patients with available lipid data, LDL-cholesterol and total cholesterol increased, while triglycerides showed a non-significant downward trend. Conclusions: A low-carbohydrate diet combined with high-frequency digital monitoring appears feasible and safe in an elderly arthroplasty population, achieving meaningful short-term improvements in weight and glycemic control without adverse renal or hypoglycemic events. The lipid changes observed warrant cautious interpretation. Larger prospective studies are needed to confirm the clinical impact of this approach and its relevance to perioperative optimization.


  • Open Access

    Rising within the leadership of an orthopaedic society: learning from the presidents

    by Gowreeson Thevendran, Mark Glazebrook, Deborah Eastwood, Kristy Weber, David Choon Siew Kit, Ashok Johari, Shanmuganathan Rajasekaran, Vikas Khanduja

    Orthopaedic societies, with their diverse membership from across the world, serve a mission to endorse the progress and innovation in the field of orthopaedics and traumatology with a focus on improving patient care, as well as to encourage and develop education, teaching and research. Such organizations, whether small or large, have been successful in meeting the professional, educational and training needs of its members. The past and future presidents of these societies share insights addressing their professional experiences, lessons learnt and their vision for future leaders of the field. The objective of this article is to summarize the thoughts of presidents of orthopaedic societies from around the globe and to inspire younger and aspiring members of the global orthopaedic fraternity.


  • Open Access

    Accuracy, Consistency, and Reproducibility of the Triaxial Accelerometer in the iPod Touch: A Pilot Study

    by Christopher Khoo Chee Han, Rukmanikanthan Al Shanmugam, David Choon Siew Kit

    The use of a mobile consumer communicative device as a motion analysis tool for patients has been researched and documented previously, examining the triaxial accelerometer embedded in such devices. However, there have been few reports in the literature testing the sensitivity of an embedded triaxial accelerometer. Our goal in this study was to test the accuracy, consistency, and reproducibility of the triaxial accelerometer in the iPod Touch. In this pilot study, we subjected the triaxial accelerometer in the iPod Touch to a free fall from a height of 100 cm in order to test its accuracy, consistency, and reproducibility under dynamic conditions. The resultant vectorial sum acceleration was mean 0.999 g (standard gravity; SD 1.51%; 95% CI 0.99-1.01), indicating very high accuracy and sensitivity under dynamic conditions. Our results highlighted the reproducibility of the capability of the triaxial accelerometer in the iPod Touch to capture data accurately and consistently. Thus, the device has huge potential as a motion analysis tool for measuring gait and studying balance and mobility in patients before and after surgery.


  • Open Access

    Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    by Guntur E Luis, Chee-Khuen Yong, Deepak A Singh, S Sengupta, David Sk Choon

    Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation. There is no difference, biomechanically, amongst the various reconstruction and augmentative methods. Controlled laboratory cadaveric study. 54 cadaveric native (acromioclavicular and coracoclavicular) ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1) in the intact states, 2) after modified Weaver-Dunn reconstruction (WD), 3) after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ), 4) after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP) or 5) after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS) and 6) after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt). Posterior-anterior (horizontal) loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005). Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p < 0.005). WD.ACJ provided additional posterior-anterior (P = 0. 039) but not superior (p = 0.250) stability when compared to WD alone. WD+PLmt, in loads and stiffness at failure superiorly, was similar to WD+CP (p = 0.066). WD+PLmt, in loads and stiffness at failure postero-anteriorly, was similar to WD+ACJ (p = 0.084). Superiorly, WD+CP had similar strength as WD+BS (p = 0.057), but it was less stiff (p < 0.005). Modified Weaver-Dunn procedure must always be supplemented with acromioclavicular capsuloligamentous repair to increase posterior-anterior stability. Palmaris-Longus tendon graft provides both additional superior and posterior-anterior stability when used for acromioclavicular capsuloligamentous reconstruction. It is a good alternative to clavicle hook plate in acromioclavicular dislocation.