TLThomas Langø

Thomas Langø

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas Langø has a total of 204 co-authors. Here are the top co-authors by number of shared publications:

  • Erlend Fagertun Hofstad

    Affiliation Department of Health Research, SINTEF, Trondheim, Norway

    15 shared publications
  • Ronald Mårvik

    Norwegian National Advisory Unit on Ultrasound and Image-Guided Therapy, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway

    13 shared publications
  • Frank Lindseth

    Affiliations Department of Computer Science, Norwegian University of Science and Technology (NTNU), Trondheim, Norway, Norwegian Open AI Lab, Norwegian University of Science and Technology (NTNU), Trondheim, Norway

    11 shared publications
  • Håkon Olav Leira

    Department of Circulation and Medical Imaging, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, 7030 Trondheim, Norway

    9 shared publications
  • Håkon Olav Leira

    Affiliation Department of Thoracic Medicine, St. Olavs Hospital, Trondheim, Norway

    8 shared publications
  • Tore Amundsen

    Department of Thoracic Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway

    8 shared publications

Latest Publications

  • Open Access

    Explainability of a Deep Learning Model for Mediastinal Lymph Node Station Classification in Endobronchial Ultrasound (EBUS)

    by Øyvind Ervik, Mia Rødde, Erlend Fagertun Hofstad, Thomas Langø, Håkon O. Leira, Tore Amundsen, Hanne Sorger

    Accurate localization of thoracic lymph nodes during endobronchial ultrasound (EBUS) is crucial for lung cancer staging, treatment planning, and prognostication. Artificial intelligence (AI) has the potential to support this process. Deep learning (DL) models often lack transparency but can benefit from explainable AI (XAI) tools like Gradient-weighted Class Activation Mapping (Grad-CAM). However, no prior study has quantitatively assessed whether model attention in EBUS imaging corresponds to relevant anatomy. This study developed a convolutional neural network (CNN) to classify thoracic lymph node stations and evaluated the anatomical relevance of Grad-CAM activations using a structured annotation framework. Applied on 35,527 labeled EBUS images, the CNN achieved 63.1% accuracy, with the highest F1-score in stations 4L, 4R, and 10R. Three expert bronchoscopists independently annotated Grad-CAM maps from 3131 test images. Activations predominantly aligned with lymph nodes and/or blood vessels, yielding an accuracy of 65.9% and an F1-score of 58.4%, with moderate interobserver agreement. These findings indicate that DL can aid lymph node station classification and that XAI offers meaningful insight into model behavior. The proposed framework may enhance anatomical orientation and operator training during EBUS, although further optimization and multicenter validation are required.


  • Open Access

    OKEN: A Supervised Evolutionary Optimizable Dimensionality Reduction Framework for Whole Slide Image Classification

    by Soroush Oskouei, André Pedersen, Marit Valla, Vibeke Grotnes Dale, Sissel Gyrid Freim Wahl, Mats Dehli Haugum, Thomas Langø, Maria Paula Ramnefjell, Lars Andreas Akslen, Gabriel Kiss, et al.

    Classification of lung cancer subtypes is a critical clinical step; however, relying solely on H&E-stained histopathology images can pose challenges, and additional immunohistochemical analysis is sometimes required for definitive subtyping. Digital pathology facilitates the use of artificial intelligence for automatic classification of digital tissue slides. Automatic classification of Whole Slide Images (WSIs) typically involves extracting features from patches obtained from them. The aim of this study was to develop a WSI classification framework utilizing an optimizable kernel to encode features from each patch from a WSI into a desirable and adjustable latent space using an evolutionary algorithm. The encoded data can then be used for classification and segmentation while being computationally more efficient. Our proposed framework is compared with a state-of-the-art model, Vim4Path, on an internal and external dataset of lung cancer WSIs. The proposed model outperforms Vim-S16 in accuracy and F1 score at both ×2.5 and ×10 magnification levels on the internal test set, with the highest accuracy (0.833) and F1 score (0.721) at ×2.5. On the external test set, Vim-S16 at ×10 achieves the highest accuracy (0.732), whereas OKEN-DenseNet121 at ×2.5 has the best F1 score (0.772). In future work, finding a dynamic way to tune the output dimensions of the evolutionary algorithm would be of value.


  • Open Access

    Segmentation of Non-Small Cell Lung Carcinomas: Introducing DRU-Net and Multi-Lens Distortion

    by Soroush Oskouei, Marit Valla, André Pedersen, Erik Smistad, Vibeke Grotnes Dale, Maren Høibø, Sissel Gyrid Freim Wahl, Mats Dehli Haugum, Thomas Langø, Maria Paula Ramnefjell, et al.

    The increased workload in pathology laboratories today means automated tools such as artificial intelligence models can be useful, helping pathologists with their tasks. In this paper, we propose a segmentation model (DRU-Net) that can provide a delineation of human non-small cell lung carcinomas and an augmentation method that can improve classification results. The proposed model is a fused combination of truncated pre-trained DenseNet201 and ResNet101V2 as a patch-wise classifier, followed by a lightweight U-Net as a refinement model. Two datasets (Norwegian Lung Cancer Biobank and Haukeland University Lung Cancer cohort) were used to develop the model. The DRU-Net model achieved an average of 0.91 Dice similarity coefficient. The proposed spatial augmentation method (multi-lens distortion) improved the Dice similarity coefficient from 0.88 to 0.91. Our findings show that selecting image patches that specifically include regions of interest leads to better results for the patch-wise classifier compared to other sampling methods. A qualitative analysis by pathology experts showed that the DRU-Net model was generally successful in tumor detection. Results in the test set showed some areas of false-positive and false-negative segmentation in the periphery, particularly in tumors with inflammatory and reactive changes. In summary, the presented DRU-Net model demonstrated the best performance on the segmentation task, and the proposed augmentation technique proved to improve the results.


  • Open Access

    A New Deep Learning-Based Method for Automated Identification of Thoracic Lymph Node Stations in Endobronchial Ultrasound (EBUS): A Proof-of-Concept Study

    by Øyvind Ervik, Mia Rødde, Erlend Fagertun Hofstad, Ingrid Tveten, Thomas Langø, Håkon O. Leira, Tore Amundsen, Hanne Sorger

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a cornerstone in minimally invasive thoracic lymph node sampling. In lung cancer staging, precise assessment of lymph node position is crucial for clinical decision-making. This study aimed to demonstrate a new deep learning method to classify thoracic lymph nodes based on their anatomical location using EBUS images. Bronchoscopists labeled lymph node stations in real-time according to the Mountain Dressler nomenclature. EBUS images were then used to train and test a deep neural network (DNN) model, with intraoperative labels as ground truth. In total, 28,134 EBUS images were acquired from 56 patients. The model achieved an overall classification accuracy of 59.5 ± 5.2%. The highest precision, sensitivity, and F1 score were observed in station 4L, 77.6 ± 13.1%, 77.6 ± 15.4%, and 77.6 ± 15.4%, respectively. The lowest precision, sensitivity, and F1 score were observed in station 10L. The average processing and prediction time for a sequence of ten images was 0.65 ± 0.04 s, demonstrating the feasibility of real-time applications. In conclusion, the new DNN-based model could be used to classify lymph node stations from EBUS images. The method performance was promising with a potential for clinical use.


  • Open Access

    Comparing assisting technologies for proficiency in cardiac morphology: 3D printing and mixed reality versus CT slice images for morphological understanding of congenital heart defects by medical students

    by Henrik Brun, Matthias Lippert, Thomas Langø, Juan Sanchez‐Margallo, Francisco Sanchez‐Margallo, Ole Jakob Elle

    Learning cardiac morphology largely involves spatial abilities and studies indicate benefits from innovative 3D visualization technologies that speed up and increase the learning output. Studies comparing these teaching tools and their educational output are rare and few studies include complex congenital heart defects. This study compared the effects of 3D prints, mixed reality (MR) viewing of 3D meshes and standard cardiac CT slice images on medical students′ understanding of complex congenital heart defect morphology, measuring both objective level of understanding and subjective educational experience. The objective of this study was to compare morphological understanding and user experiences of 3D printed models, MR 3D visualization and axial 2D CT slices, in medical students examining morphological details in complex congenital heart defects. Medical students in the median 4th year of study (range 2nd to 6th) examined three of five different complex congenital heart defects by three different modalities: 3D printed model, MR viewed 3D mesh, and cardiac CT slices, answering a questionnaire on morphology and user experience. Time to complete task, diagnostic accuracy, and user experience data were collected and compared on group level. Task times were similar for all modalities. The percentage of correct answers was higher with MR visualization, which was also the preferred modality overall. Medical students both prefer and better understand the morphology of complex congenital heart disease with 3D models viewed using MR, without spending more time than with 3D prints or 2D CT images.


  • Top Cited Papers
    Open Access

    AeroPath: An airway segmentation benchmark dataset with challenging pathology and baseline method

    by Karen-Helene Støverud, David Bouget, André Pedersen, Håkon Olav Leira, Tore Amundsen, Thomas Langø, Erlend Fagertun Hofstad

    To improve the prognosis of patients suffering from pulmonary diseases, such as lung cancer, early diagnosis and treatment are crucial. The analysis of CT images is invaluable for diagnosis, whereas high quality segmentation of the airway tree are required for intervention planning and live guidance during bronchoscopy. Recently, the Multi-domain Airway Tree Modeling (ATM’22) challenge released a large dataset, both enabling training of deep-learning based models and bringing substantial improvement of the state-of-the-art for the airway segmentation task. The ATM’22 dataset includes a large group of COVID’19 patients and a range of other lung diseases, however, relatively few patients with severe pathologies affecting the airway tree anatomy was found. In this study, we introduce a new public benchmark dataset (AeroPath), consisting of 27 CT images from patients with pathologies ranging from emphysema to large tumors, with corresponding trachea and bronchi annotations. Second, we present a multiscale fusion design for automatic airway segmentation. Models were trained on the ATM’22 dataset, tested on the AeroPath dataset, and further evaluated against competitive open-source methods. The same performance metrics as used in the ATM’22 challenge were used to benchmark the different considered approaches. Lastly, an open web application is developed, to easily test the proposed model on new data. The results demonstrated that our proposed architecture predicted topologically correct segmentations for all the patients included in the AeroPath dataset. The proposed method is robust and able to handle various anomalies, down to at least the fifth airway generation. In addition, the AeroPath dataset, featuring patients with challenging pathologies, will contribute to development of new state-of-the-art methods. The AeroPath dataset and the web application are made openly available.


  • Open Access

    Navigated ultrasound bronchoscopy with integrated positron emission tomography—A human feasibility study

    by Arne Kildahl-Andersen, Erlend Fagertun Hofstad, Ole-Vegard Solberg, Hanne Sorger, Tore Amundsen, Thomas Langø, Håkon Olav Leira

    Background and objective: Patients suspected to have lung cancer, undergo endobronchial ultrasound bronchoscopy (EBUS) for the purpose of diagnosis and staging. For presumptive curable patients, the EBUS bronchoscopy is planned based on images and data from computed tomography (CT) images and positron emission tomography (PET). Our study aimed to evaluate the feasibility of a multimodal electromagnetic navigation platform for EBUS bronchoscopy, integrating ultrasound and segmented CT, and PET scan imaging data. Methods: The proof-of-concept study included patients with suspected lung cancer and pathological mediastinal/hilar lymph nodes identified on both CT and PET scans. Images obtained from these two modalities were segmented to delineate target lymph nodes and then incorporated into the CustusX navigation platform. The EBUS bronchoscope was equipped with a sensor, calibrated, and affixed to a 3D printed click-on device positioned at the bronchoscope’s tip. Navigation accuracy was measured postoperatively using ultrasound recordings. Results: The study enrolled three patients, all presenting with suspected mediastinal lymph node metastasis (N1-3). All PET-positive lymph nodes were displayed in the navigation platform during the EBUS procedures. In total, five distinct lymph nodes were sampled, yielding malignant cells from three nodes and lymphocytes from the remaining two. The median accuracy of the navigation system was 7.7 mm. Conclusion: Our study introduces a feasible multimodal electromagnetic navigation platform that combines intraoperative ultrasound with preoperative segmented CT and PET imaging data for EBUS lymph node staging examinations. This innovative approach holds promise for enhancing the accuracy and effectiveness of EBUS procedures.

  • Open Access

    Automatic Segmentation of Mediastinal Lymph Nodes and Blood Vessels in Endobronchial Ultrasound (EBUS) Images Using Deep Learning

    by Øyvind Ervik, Ingrid Tveten, Erlend Fagertun Hofstad, Thomas Langø, Håkon Olav Leira, Tore Amundsen, Hanne Sorger

    Endobronchial ultrasound (EBUS) is used in the minimally invasive sampling of thoracic lymph nodes. In lung cancer staging, the accurate assessment of mediastinal structures is essential but challenged by variations in anatomy, image quality, and operator-dependent image interpretation. This study aimed to automatically detect and segment mediastinal lymph nodes and blood vessels employing a novel U-Net architecture-based approach in EBUS images. A total of 1161 EBUS images from 40 patients were annotated. For training and validation, 882 images from 30 patients and 145 images from 5 patients were utilized. A separate set of 134 images was reserved for testing. For lymph node and blood vessel segmentation, the mean ± standard deviation (SD) values of the Dice similarity coefficient were 0.71 ± 0.35 and 0.76 ± 0.38, those of the precision were 0.69 ± 0.36 and 0.82 ± 0.22, those of the sensitivity were 0.71 ± 0.38 and 0.80 ± 0.25, those of the specificity were 0.98 ± 0.02 and 0.99 ± 0.01, and those of the F1 score were 0.85 ± 0.16 and 0.81 ± 0.21, respectively. The average processing and segmentation run-time per image was 55 ± 1 ms (mean ± SD). The new U-Net architecture-based approach (EBUS-AI) could automatically detect and segment mediastinal lymph nodes and blood vessels in EBUS images. The method performed well and was feasible and fast, enabling real-time automatic labeling.


  • Open Access

    Automated segmentation of the median nerve in patients with carpal tunnel syndrome

    by Florentin Moser, Sébastien Muller, Torgrim Lie, Thomas Langø, Mari Hoff

    Machine learning and deep learning are novel methods which are revolutionizing medical imaging. In our study we trained an algorithm with a U-Net shaped network to recognize ultrasound images of the median nerve in the complete distal half of the forearm and to measure the cross-sectional area at the inlet of the carpal tunnel. Images of 25 patient hands with carpal tunnel syndrome (CTS) and 26 healthy controls were recorded on a video loop covering 15 cm of the distal forearm and 2355 images were manually segmented. We found an average Dice score of 0.76 between manual and automated segmentation of the median nerve in its complete course, while the measurement of the cross-sectional area at the carpal tunnel inlet resulted in a 10.9% difference between manually and automated measurements. We regard this technology as a suitable device for verifying the diagnosis of CTS.


  • Open Access

    Navigated ultrasound bronchoscopy with integrated positron emission tomography - A human feasibility study

    by Arne Kildahl-Andersen, Erlend Fagertun Hofstad, Ole-Vegard Solberg, Hanne Sorger, Tore Amundsen, Thomas Langø, Håkon Olav Leira

    Background and objective Patients suspected to have lung cancer, undergo endobronchial ultrasound bronchoscopy (EBUS) for the purpose of diagnosis and staging. For presumptive curable patients, the EBUS bronchoscopy is planned based on images and data from computed tomography (CT) images and positron emission tomography (PET). Our study aimed to evaluate the feasibility of a multimodal electromagnetic navigation platform for EBUS bronchoscopy, integrating ultrasound and segmented CT, and PET scan imaging data. Methods The proof-of-concept study included patients with suspected lung cancer and pathological mediastinal/hilar lymph nodes identified on both CT and PET scans. Images obtained from these two modalities were segmented to delineate target lymph nodes and then incorporated into the CustusX navigation platform. The EBUS bronchoscope was equipped with a sensor, calibrated, and affixed to a 3D printed click-on device positioned at the bronchoscope’s tip. Navigation accuracy was measured postoperatively using ultrasound recordings. Results The study enrolled three patients, all presenting with suspected mediastinal lymph node metastasis (N1-3). All PET-positive lymph nodes were displayed in the navigation platform during the EBUS procedures. In total, five distinct lymph nodes were sampled, yielding malignant cells from three nodes and lymphocytes from the remaining two. The median accuracy of the navigation system was 7.7 mm. Conclusion Our study introduces a feasible multimodal electromagnetic navigation platform that combines intraoperative ultrasound with preoperative segmented CT and PET imaging data for EBUS lymph node staging examinations. This innovative approach holds promise for enhancing the accuracy and effectiveness of EBUS procedures.