Amine Yazidi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amine Yazidi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Franck Betin
Laboratory of Innovative Technologies (LTI, UR 3899), University of Picardie Jules Verne, 80000 Amiens, France
14 shared publications - Gerard-Andre Capolino
Department of Electrical Engineering, University of Picardie Jules Verne, Amiens, France
7 shared publications - Omar Bouyahia
Laboratory of Innovative Technologies (LTI, UR 3899), University of Picardie Jules Verne, 80000 Amiens, France
5 shared publications - Marius Ouédraogo
Laboratory of Innovative Technologies (LTI, UR 3899), University of Picardie Jules Verne, 80000 Amiens, France
3 shared publications Alin Pantea
Laboratory of Innovative Technologies; University of Picardie Jules Verne, Amiens, France
2 shared publications- Bruno Vacossin
France
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (6) , 9790-9799
Advances in Six-Phase Induction Machines: Design, Modeling, Control, and Diagnosis
This review paper provides an overview of recent advancements in the design, modeling, control, and diagnosis techniques of six-phase induction machines. With an increasing focus on multiphase machines for various applications, the study highlights key developments in six-phase induciton machines, including innovations in design methodologies, advancements in modeling techniques, novel control strategies, and emerging diagnosis approaches. By synthesizing findings from recent research, this paper aims to offer insights into the current state of the field and inspire further exploration and refinement of methodologies for optimizing the performance and reliability of six-phase induction machines.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (6) , 9790-9799
Advances in Six-Phase Induction Machines: Design, Modeling, Control, and Diagnosis
This review paper provides an overview of recent advancements in the design, modeling, control, and diagnosis techniques of six-phase induction machines. With an increasing focus on multiphase machines for various applications, the study highlights key developments in six-phase induciton machines, including innovations in design methodologies, advancements in modeling techniques, novel control strategies, and emerging diagnosis approaches. By synthesizing findings from recent research, this paper aims to offer insights into the current state of the field and inspire further exploration and refinement of methodologies for optimizing the performance and reliability of six-phase induction machines.
- Open Access
Sensorless Field-Oriented Control of a Low-Speed Six-Phase Induction Generator
This paper presents a sensorless control strategy for a six-phase induction generator (6PIG) operating at low speed (125 rpm). The proposed approach is based on the Model Reference Adaptive System (MRAS), with an initial estimation scheme developed using the reference model as the rotor flux. Simulation studies were conducted in MATLAB/Simulink 24.2.0.2740171 (R2024b) Update 1 and experimentally validated on a 24 kW–125 rpm 6PIG, to demonstrate the feasibility and performance of this method. A reactive power-based MRAS variant was also proposed to overcome the observed limitations. Comparative analysis showed a significant improvement in estimation accuracy and dynamic response compared with the flux-based MRAS. Robustness tests under fault conditions, such as opening phases, confirmed that the reactive power-based MRAS maintains a stable and accurate rotor speed estimation. These findings demonstrate the potential of reactive-power-based MRAS for the sensorless control of six-phase induction generators (6PIGs) in renewable energy systems.
Open AccessSensorless Field-Oriented Control of a Low-Speed Six-Phase Induction Generator
This paper presents a sensorless control strategy for a six-phase induction generator (6PIG) operating at low speed (125 rpm). The proposed approach is based on the Model Reference Adaptive System (MRAS), with an initial estimation scheme developed using the reference model as the rotor flux. Simulation studies were conducted in MATLAB/Simulink 24.2.0.2740171 (R2024b) Update 1 and experimentally validated on a 24 kW–125 rpm 6PIG, to demonstrate the feasibility and performance of this method. A reactive power-based MRAS variant was also proposed to overcome the observed limitations. Comparative analysis showed a significant improvement in estimation accuracy and dynamic response compared with the flux-based MRAS. Robustness tests under fault conditions, such as opening phases, confirmed that the reactive power-based MRAS maintains a stable and accurate rotor speed estimation. These findings demonstrate the potential of reactive-power-based MRAS for the sensorless control of six-phase induction generators (6PIGs) in renewable energy systems.
- Open Access
Online Efficiency Optimization of a Six-Phase Induction Generator Using Loss Model Control for Micro-Hydropower Systems
This paper presents an online efficiency optimization strategy for a six-phase induction generator (6PIG) operating in both healthy and faulty modes for micro-hydropower applications. The proposed method is based on an extended Loss Model Control (LMC) approach, in which the direct axis stator current Id is dynamically optimized in real time to minimize the total electrical losses. Unlike conventional LMC strategies, this method explicitly incorporates switching losses into the loss model, along with stator and rotor copper losses and iron losses. The optimization problem is solved using a numerical minimization routine, allowing the control system to adapt continuously to variations in torque requests. The proposed approach is validated under both healthy and faulty configurations of the 6PIG. It is implemented and tested through simulation in MATLAB/Simulink® and experimentally validated on a 24 kW squirrel cage six-phase induction generator (SC6PIG). The results are compared in terms of power losses, energy saving, and efficiency.
Open AccessOnline Efficiency Optimization of a Six-Phase Induction Generator Using Loss Model Control for Micro-Hydropower Systems
This paper presents an online efficiency optimization strategy for a six-phase induction generator (6PIG) operating in both healthy and faulty modes for micro-hydropower applications. The proposed method is based on an extended Loss Model Control (LMC) approach, in which the direct axis stator current Id is dynamically optimized in real time to minimize the total electrical losses. Unlike conventional LMC strategies, this method explicitly incorporates switching losses into the loss model, along with stator and rotor copper losses and iron losses. The optimization problem is solved using a numerical minimization routine, allowing the control system to adapt continuously to variations in torque requests. The proposed approach is validated under both healthy and faulty configurations of the 6PIG. It is implemented and tested through simulation in MATLAB/Simulink® and experimentally validated on a 24 kW squirrel cage six-phase induction generator (SC6PIG). The results are compared in terms of power losses, energy saving, and efficiency.
- Open Access
Control of Grid-Connected and Standalone Microhydraulic Turbine Using a Six-Phase Induction Generator
Microhydraulic turbines offer a promising solution for decentralized energy production, suitable for both grid-connected and standalone applications, due to their compactness and high efficiency. This paper introduces a control approach for such systems employing microhydraulic turbines as distributed generators (DGs), utilizing six-phase induction generators for electricity production. This study emphasizes control strategies for both grid-connected and standalone modes utilizing proportional-integral (PI) controllers. An integrated energy storage system based on Li-Ion battery technology is also implemented to store the excess energy and compensate for production deficits to meet demand. The results obtained using MATLAB/Simulink demonstrate efficient and reliable power management among production sources, the grid and the local load, highlighting the unique contribution of employing a six-phase induction generator with the energy storage system.
Open AccessControl of Grid-Connected and Standalone Microhydraulic Turbine Using a Six-Phase Induction Generator
Microhydraulic turbines offer a promising solution for decentralized energy production, suitable for both grid-connected and standalone applications, due to their compactness and high efficiency. This paper introduces a control approach for such systems employing microhydraulic turbines as distributed generators (DGs), utilizing six-phase induction generators for electricity production. This study emphasizes control strategies for both grid-connected and standalone modes utilizing proportional-integral (PI) controllers. An integrated energy storage system based on Li-Ion battery technology is also implemented to store the excess energy and compensate for production deficits to meet demand. The results obtained using MATLAB/Simulink demonstrate efficient and reliable power management among production sources, the grid and the local load, highlighting the unique contribution of employing a six-phase induction generator with the energy storage system.
- Open Access
Experimental Comparison of Robust Control Algorithms for Torque Ripple Reduction in Multiphase Induction Generators
This paper introduces robust nonlinear controller strategies for multiphase induction machines, aiming to enhance operational reliability under healthy and faulty conditions, including stator phase and converter leg openings. Due to the induction machine’s inherent nonlinearities and parameter variations, a robust control is required. The study evaluates the effectiveness of the sliding mode control with linear feedback and switched gains, the fuzzy proportional integral control, and their combined application in both healthy and faulty modes. The experimental assessment involves a symmetrical six-phase induction machine in generation mode, with comparisons with a classic proportional integral controller for inner current loop regulations. Experimental results show that the fuzzy proportional integral controller presents the best performance by minimizing torque ripples during both healthy and faulty operations.
Open AccessExperimental Comparison of Robust Control Algorithms for Torque Ripple Reduction in Multiphase Induction Generators
This paper introduces robust nonlinear controller strategies for multiphase induction machines, aiming to enhance operational reliability under healthy and faulty conditions, including stator phase and converter leg openings. Due to the induction machine’s inherent nonlinearities and parameter variations, a robust control is required. The study evaluates the effectiveness of the sliding mode control with linear feedback and switched gains, the fuzzy proportional integral control, and their combined application in both healthy and faulty modes. The experimental assessment involves a symmetrical six-phase induction machine in generation mode, with comparisons with a classic proportional integral controller for inner current loop regulations. Experimental results show that the fuzzy proportional integral controller presents the best performance by minimizing torque ripples during both healthy and faulty operations.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (6) , 7308-7317
Optimal Sliding Mode Control of a Symmetrical Six-Phase Induction Generator for Wind Turbines
In this paper, a Sliding Mode Control (SMC) is applied to regulate the delivered power of a symmetrical six-phase induction generator. For this, the SMC strategy associated to the Field Oriented Control (FOC) strategy is used in order to adjust the inner current loops of a Squirrel Cage Six-Phase Induction Generator (SC6PIG). In this way, the control algorithm switches between positive and negative feedbacks according to the position of the operating point in the phase plane. This technique guarantees the robustness of the SC6PIG in case of the loss of one to three stator phases or machine converter legs. The switching line slope and the initial operating point have been set so that the system starts with a negative feedback, then it continuously switches back and forth to positive feedback in order to maintain the desired trajectory of the system. The simulation and experimental results demonstrate the effectiveness and the robustness of this technique since the delivered power of the SC6PIG presents the same dynamics in healthy or faulty modes with one to two phase losses.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (6) , 7308-7317
Optimal Sliding Mode Control of a Symmetrical Six-Phase Induction Generator for Wind Turbines
In this paper, a Sliding Mode Control (SMC) is applied to regulate the delivered power of a symmetrical six-phase induction generator. For this, the SMC strategy associated to the Field Oriented Control (FOC) strategy is used in order to adjust the inner current loops of a Squirrel Cage Six-Phase Induction Generator (SC6PIG). In this way, the control algorithm switches between positive and negative feedbacks according to the position of the operating point in the phase plane. This technique guarantees the robustness of the SC6PIG in case of the loss of one to three stator phases or machine converter legs. The switching line slope and the initial operating point have been set so that the system starts with a negative feedback, then it continuously switches back and forth to positive feedback in order to maintain the desired trajectory of the system. The simulation and experimental results demonstrate the effectiveness and the robustness of this technique since the delivered power of the SC6PIG presents the same dynamics in healthy or faulty modes with one to two phase losses.
- 14 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 171-176
Robust Control Based on Variable Structure of a Symmetrical Six Phase PMSM For Wind Turbine
In this paper, we propose one of the most advanced controllers in order to increase the reliability and efficiency of the multiphase generators. A variable structure control (VSC) based on the sliding mode theory is designed to control the inner current loops of a symmetrical Six-Phase Axial Flux Permanent Magnet Synchronous Generator (6P-AF-PMSG). This technique presents a good performance between static accuracy and speed of the response. However, the proposed controller law is not only insensitive to the plant parameters, but it is also robust under external disturbances. The stability of the system will be demonstrated via Lyapunov analysis. Experimental tests illustrate the robustness of this law control strategy in healthy and faulty conditions with one to three missing phases.
- 14 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 171-176
Robust Control Based on Variable Structure of a Symmetrical Six Phase PMSM For Wind Turbine
In this paper, we propose one of the most advanced controllers in order to increase the reliability and efficiency of the multiphase generators. A variable structure control (VSC) based on the sliding mode theory is designed to control the inner current loops of a symmetrical Six-Phase Axial Flux Permanent Magnet Synchronous Generator (6P-AF-PMSG). This technique presents a good performance between static accuracy and speed of the response. However, the proposed controller law is not only insensitive to the plant parameters, but it is also robust under external disturbances. The stability of the system will be demonstrated via Lyapunov analysis. Experimental tests illustrate the robustness of this law control strategy in healthy and faulty conditions with one to three missing phases.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1
Fault Tolerant Variable Structure Control Of Six-phase Induction Generator For Wind Turbines
In this paper, a fault-tolerant control of the six-phase induction generator based on a variable structure strategy is experimentally tested and compared with a classical proportional-integral controller. For this, we use a linear feedback sliding mode with switched feedback gains with the objective to control the current inner loops of this machine. One main drawback of the classical three-phase induction generator is that it is no longer possible to generate electrical power if only one phase is lost on the stator side. To overcome this issue, we will use a squirrel cage six-phase induction machine that can still operate when at least three phases remain on the stator side. This article proposes to use a variable structure control in order to cope with unbalanced currents and also maintain the generation of power when a loss of the stators phases occurs. The proposed controller shows its robustness and good regulation performance in healthy and faulty modes. The simulation and experimental tests were carried out with a 24kW induction machine that represents 1/100 of the electrical power of a real wind turbine.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. PP (08858969) , 1
Fault Tolerant Variable Structure Control Of Six-phase Induction Generator For Wind Turbines
In this paper, a fault-tolerant control of the six-phase induction generator based on a variable structure strategy is experimentally tested and compared with a classical proportional-integral controller. For this, we use a linear feedback sliding mode with switched feedback gains with the objective to control the current inner loops of this machine. One main drawback of the classical three-phase induction generator is that it is no longer possible to generate electrical power if only one phase is lost on the stator side. To overcome this issue, we will use a squirrel cage six-phase induction machine that can still operate when at least three phases remain on the stator side. This article proposes to use a variable structure control in order to cope with unbalanced currents and also maintain the generation of power when a loss of the stators phases occurs. The proposed controller shows its robustness and good regulation performance in healthy and faulty modes. The simulation and experimental tests were carried out with a 24kW induction machine that represents 1/100 of the electrical power of a real wind turbine.
- Open Access
Fault-Tolerant Fuzzy Logic Control of a 6-Phase Axial Flux Permanent-Magnet Synchronous Generator
The objective of this paper is to propose the real-time implementation of a fault-tolerant strategy based on fuzzy logic controller (FLC) for a Six-Phase Axial Flux Permanent Magnet Synchronous Machine (6P-AFPMSM) for electrical energy production. This type of machine, suitable for high-power applications, is highly affected by the harmonics of the inductances and the electromotive force (emf) compared to the classical three-phase radial flux machine, which will influence the controller parameters of the machine. The proposed control strategy based on FLC is independent of the system model and guarantees the robustness of the process against disturbances and parameter variations of the model. An experimental comparison between FLC and a classical PI controller confirms the efficiency and the robustness of the proposed controller in healthy and faulty conditions with one open phase.
Open AccessFault-Tolerant Fuzzy Logic Control of a 6-Phase Axial Flux Permanent-Magnet Synchronous Generator
The objective of this paper is to propose the real-time implementation of a fault-tolerant strategy based on fuzzy logic controller (FLC) for a Six-Phase Axial Flux Permanent Magnet Synchronous Machine (6P-AFPMSM) for electrical energy production. This type of machine, suitable for high-power applications, is highly affected by the harmonics of the inductances and the electromotive force (emf) compared to the classical three-phase radial flux machine, which will influence the controller parameters of the machine. The proposed control strategy based on FLC is independent of the system model and guarantees the robustness of the process against disturbances and parameter variations of the model. An experimental comparison between FLC and a classical PI controller confirms the efficiency and the robustness of the proposed controller in healthy and faulty conditions with one open phase.
- 14 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (1) , 426-436
Fault-Tolerant Control of a Low-Speed Six-Phase Induction Generator for Wind Turbines
In this paper, a fault tolerant control scheme for a low speed squirrel cage 6-phase induction generator (SC6PIG) connected to a full-scale back-to-back converter structure is proposed and tested on an experimental 24kW wind turbine test bed that represents a 1/100 of the electrical power of a grid connected real wind turbine multiphase generator (2.5MW). The aim is to define a suitable control algorithm that allows the electrical generation despite the loss of one to three phases on the generator or converter sides. Furthermore, the pole number of the generator is increased to simplify or eliminate the gearbox in such a way as to reduce mechanical sensitivity. Indeed, by multiplying the phase and pole numbers, the robustness against mechanical and electrical faults is improved compared to that of a classic 3-phase generator associated with a gearbox. Simulation and experimental tests carried out on a 24kW-230V-24-pole SC6PIG in healthy and faulty mode (1 phase missing) assess the feasibility and capacity of the proposed strategy.
- 14 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (1) , 426-436
Fault-Tolerant Control of a Low-Speed Six-Phase Induction Generator for Wind Turbines
In this paper, a fault tolerant control scheme for a low speed squirrel cage 6-phase induction generator (SC6PIG) connected to a full-scale back-to-back converter structure is proposed and tested on an experimental 24kW wind turbine test bed that represents a 1/100 of the electrical power of a grid connected real wind turbine multiphase generator (2.5MW). The aim is to define a suitable control algorithm that allows the electrical generation despite the loss of one to three phases on the generator or converter sides. Furthermore, the pole number of the generator is increased to simplify or eliminate the gearbox in such a way as to reduce mechanical sensitivity. Indeed, by multiplying the phase and pole numbers, the robustness against mechanical and electrical faults is improved compared to that of a classic 3-phase generator associated with a gearbox. Simulation and experimental tests carried out on a 24kW-230V-24-pole SC6PIG in healthy and faulty mode (1 phase missing) assess the feasibility and capacity of the proposed strategy.