SYSheng Yan

Sheng Yan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sheng Yan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Su-Schrieffer-Heeger model inspired acoustic interface states and edge states

    by Xin Li, Yan Meng, Xiaoxiao Wu, Sheng Yan, Yingzhou Huang, Shuxia Wang, Weijia Wen

    If a full bandgap closes and then reopens when we continuously deform a periodic system while keeping its symmetry, a topological phase transition usually occurs. A common model demonstrating such a topological phase transition in condensed matter physics is the Su-Schrieffer-Heeger (SSH) model. As is well known, two distinct topological phases emerge when the intracell hopping is tuned from smaller to larger with respect to the intercell hopping in the model. The former case is topologically trivial, while the latter case is topologically non-trivial. Here, we design a 1D periodic acoustic system in exact analogy with the SSH model. The unit cell of the acoustic system is composed of two resonators and two junction tubes connecting them. We show that the topological phase transition happens in our acoustic analog when we tune the radii of the junction tubes which control the intercell and intracell hoppings. The topological phase transition is characterized by the abrupt change in the geometric Zak phase. The topological interface states between non-trivial and trivial phases of our acoustic analog are experimentally measured, and the results agree very well with the numerical values. Furthermore, we show that topologically non-trivial phases of our acoustic analog of the SSH model can support edge states, on which the discussion is absent in previous works about topological acoustics. The edge states are robust against localized defects and perturbations.


  • High-throughput, sheathless, magnetophoretic separation of magnetic and non-magnetic particles with a groove-based channel

    by S. Yan, J. Zhang, D. Yuan, Q. Zhao, J. Ma, W. H. Li

    The separation of target objects conjugated with magnetic particles is a significant application in biomedicine and clinical diagnosis. Conventional magnetophoresis-based devices use a sheath flow to pre-focus the particles into a single stream and typically operate at a low flow rate. We demonstrate in this work a high-throughput, sheathless, magnetophoretic separation of magnetic and non-magnetic beads in a groove-based channel, and also report on an interesting phenomenon where the same magnetic beads in the same microchannel, but with different setups, has a different particle tracing; a binary mixture of magnetic and non-magnetic beads in a diluted ferrofluid, is then fed into the channel. These magnetic beads are focused near the centreline of the channel by exploiting positive magnetophoresis and microvortices generated by grooves, whereas the non-magnetic beads are focused along the sidewalls of the channel by negative magnetophoresis and hydrophoresis. These magnetic and non-magnetic beads are separated in a wide range of flow rates (up to 80 μl min−1).


  • A label-free and high-throughput separation of neuron and glial cells using an inertial microfluidic platform

    by Tiantian Jin, Sheng Yan, Jun Zhang, Dan Yuan, Xu-Feng Huang, Weihua Li

    While neurons and glial cells both play significant roles in the development and therapy of schizophrenia, their specific contributions are difficult to differentiate because the methods used to separate neurons and glial cells are ineffective and inefficient. In this study, we reported a high-throughput microfluidic platform based on the inertial microfluidic technique to rapidly and continuously separate neurons and glial cells from dissected brain tissues. The optimal working condition for an inertial biochip was investigated and evaluated by measuring its separation under different flow rates. Purified and enriched neurons in a primary neuron culture were verified by confocal immunofluorescence imaging, and neurons performed neurite growth after separation, indicating the feasibility and biocompatibility of an inertial separation. Phencyclidine disturbed the neuroplasticity and neuron metabolism in the separated and the unseparated neurons, with no significant difference. Apart from isolating the neurons, purified and enriched viable glial cells were collected simultaneously. This work demonstrates that an inertial microchip can provide a label-free, high throughput, and harmless tool to separate neurological primary cells.


  • Dean-flow-coupled elasto-inertial three-dimensional particle focusing under viscoelastic flow in a straight channel with asymmetrical expansion–contraction cavity arrays

    by D. Yuan, J. Zhang, S. Yan, C. Pan, G. Alici, N. T. Nguyen, W. H. Li

    In this paper, 3D particle focusing in a straight channel with asymmetrical expansion–contraction cavity arrays (ECCA channel) is achieved by exploiting the dean-flow-coupled elasto-inertial effects. First, the mechanism of particle focusing in both Newtonian and non-Newtonian fluids was introduced. Then particle focusing was demonstrated experimentally in this channel with Newtonian and non-Newtonian fluids using three different sized particles (3.2 μm, 4.8 μm, and 13 μm), respectively. Also, the effects of dean flow (or secondary flow) induced by expansion–contraction cavity arrays were highlighted by comparing the particle distributions in a single straight rectangular channel with that in the ECCA channel. Finally, the influences of flow rates and distances from the inlet on focusing performance in the ECCA channel were studied. The results show that in the ECCA channel particles are focused on the cavity side in Newtonian fluid due to the synthesis effects of inertial and dean-drag force, whereas the particles are focused on the opposite cavity side in non-Newtonian fluid due to the addition of viscoelastic force. Compared with the focusing performance in Newtonian fluid, the particles are more easily and better focused in non-Newtonian fluid. Besides, the Dean flow in visco-elastic fluid in the ECCA channel improves the particle focusing performance compared with that in a straight channel. A further advantage is three-dimensional (3D) particle focusing that in non-Newtonian fluid is realized according to the lateral side view of the channel while only two-dimensional (2D) particle focusing can be achieved in Newtonian fluid. Conclusively, this novel Dean-flow-coupled elasto-inertial microfluidic device could offer a continuous, sheathless, and high throughput (>10 000 s−1) 3D focusing performance, which may be valuable in various applications from high speed flow cytometry to cell counting, sorting, and analysis.


  • Open Access

    Making a hydrophoretic focuser tunable using a diaphragm

    by Sheng Yan, Jun Zhang, Huaying Chen, Gursel Alici, Haiping Du, Yonggang Zhu, Weihua Li

    Microfluidic diagnostic devices often require handling particles or cells with different sizes. In this investigation, a tunable hydrophoretic device was developed which consists of a polydimethylsiloxane (PDMS) slab with hydrophoretic channel, a PDMS diaphragm with pressure channel, and a glass slide. The height of the hydrophoretic channel can be tuned simply and reliably by deforming the elastomeric diaphragm with pressure applied on the pressure channel. This operation allows the device to have a large operating range where different particles and complex biological samples can be processed. The focusing performance of this device was tested using blood cells that varied in shape and size. The hydrophoretic channel had a large cross section which enabled a throughput capability for cell focusing of ∼15 000 cells s−1, which was more than the conventional hydrophoretic focusing and dielectrophoresis (DEP)-active hydrophoretic methods. This tunable hydrophoretic focuser can potentially be integrated into advanced lab-on-a-chip bioanalysis devices.