Piet W. Boonstra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Piet W. Boonstra has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Aaron Crowley
Clinical Trials Center, Cardiovascular Research Foundation, New York, New York
1 shared publicationArie Pieter Kappetein
Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands
1 shared publicationBernard J. Gersh
Department of Cardiovascular Medicine, Mayo Clinic College of Medicine, Rochester, Minnesota
1 shared publicationG. Rakhorst
Department of Biomedical Engineering, Groningen University Medical Center, Groningen - The Netherlands
1 shared publication- Gregg Whitney Stone
Icahn School of Medicine at Mount Sinai , New York, NY
1 shared publication Ioanna Kosmidou
Clinical Trials Center, Cardiovascular Research Foundation, New York, New York; NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
1 shared publication
Latest Publications
- 1 January 2020
- Published by Elsevier in The American Journal of Cardiology
- Vol. 125 (2) , 169-175
Usefulness of Discharge Resting Heart Rate to Predict Adverse Cardiovascular Outcomes in Patients With Left Main Coronary Artery Disease Revascularized With Percutaneous Coronary Intervention vs Coronary Artery Bypass Grafting (from the EXCEL Trial)
- 1 January 2020
- Published by Elsevier in The American Journal of Cardiology
- Vol. 125 (2) , 169-175
Usefulness of Discharge Resting Heart Rate to Predict Adverse Cardiovascular Outcomes in Patients With Left Main Coronary Artery Disease Revascularized With Percutaneous Coronary Intervention vs Coronary Artery Bypass Grafting (from the EXCEL Trial)
- 1 January 2005
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 28 (1) , 35-43
Augmentation of Abdominal Organ Perfusion during Cardiopulmonary Bypass with a Novel Intra-aortic Pulsatile Catheter Pump
Background: Current pulsatile pumps for cardiopulmonary bypass (CPB) are far from satisfactory because of the poor pulsatility. This study was undertaken to examine the efficiency of a novel pulsatile catheter pump on pulsatility and its effect on abdominal organ perfusion during CPB. Methods: Twelve pigs weighing 89±11 kg were randomly divided into a pulsatile group (n=6) and a non-pulsatile group (n=6). All animals had a CPB for 120 min, aorta clamped for 60 min, temperature down to 32°C, and a perfusion flow of 60 ml/kg/min. In the pulsatile group, a 21 Fr intra-aortic pulsatile catheter, which was connected to a 40 mL membrane pump, was placed in the descending aorta and activated by a balloon pump driver during the first 90 minutes of CPB until aortic declamping. Hemodynamics, organ blood flow, body metabolism, and blood trauma were studied during experiments. Results: Compared with the non-pulsatile group during CPB, the pulsatile group had a higher systolic blood pressure (P&0.01), higher mean arterial pressure (P&0.05), and higher blood flow to the superior mesenteric artery (P&0.05). The hemodynamic energy, indicated by the energy equivalent pressure (EEP) was higher in the gastrointestinal tract and kidney in the pulsatile group (P&0.01, P&0.01). Abdominal organ perfusion status, as indicated by SvO2 in the inferior vena cava, was higher in the pulsatile group (P&0.05) 30 min after cessation of CPB. Hemolysis indicated by release of free hemoglobin during CPB was similar in the two groups. Conclusion: Applying the pulsatile catheter pump in the descending aorta is effective in supplying the pulsatile flow to the abdominal organs and results in improved abdominal organ perfusion during the ischemic phase of CPB.
- 1 January 2005
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 28 (1) , 35-43
Augmentation of Abdominal Organ Perfusion during Cardiopulmonary Bypass with a Novel Intra-aortic Pulsatile Catheter Pump
Background: Current pulsatile pumps for cardiopulmonary bypass (CPB) are far from satisfactory because of the poor pulsatility. This study was undertaken to examine the efficiency of a novel pulsatile catheter pump on pulsatility and its effect on abdominal organ perfusion during CPB. Methods: Twelve pigs weighing 89±11 kg were randomly divided into a pulsatile group (n=6) and a non-pulsatile group (n=6). All animals had a CPB for 120 min, aorta clamped for 60 min, temperature down to 32°C, and a perfusion flow of 60 ml/kg/min. In the pulsatile group, a 21 Fr intra-aortic pulsatile catheter, which was connected to a 40 mL membrane pump, was placed in the descending aorta and activated by a balloon pump driver during the first 90 minutes of CPB until aortic declamping. Hemodynamics, organ blood flow, body metabolism, and blood trauma were studied during experiments. Results: Compared with the non-pulsatile group during CPB, the pulsatile group had a higher systolic blood pressure (P&0.01), higher mean arterial pressure (P&0.05), and higher blood flow to the superior mesenteric artery (P&0.05). The hemodynamic energy, indicated by the energy equivalent pressure (EEP) was higher in the gastrointestinal tract and kidney in the pulsatile group (P&0.01, P&0.01). Abdominal organ perfusion status, as indicated by SvO2 in the inferior vena cava, was higher in the pulsatile group (P&0.05) 30 min after cessation of CPB. Hemolysis indicated by release of free hemoglobin during CPB was similar in the two groups. Conclusion: Applying the pulsatile catheter pump in the descending aorta is effective in supplying the pulsatile flow to the abdominal organs and results in improved abdominal organ perfusion during the ischemic phase of CPB.