Kwok Hung Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kwok Hung Chan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Sai Wing Leung
Department of Electronic Engineering, City University of Hong Kong, Hong Kong
29 shared publications L. C. Fung
Department of Electronic Engineering, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong, SAR, P.R. China
15 shared publications- Yun Ming Siu
Department of Electronic Engineering, City University of Hong Kong, Hong Kong
10 shared publications C. K. Tang
Department of Electronic Engineering, City University of Hong Kong, Hong Kong
8 shared publications- Akimasa Hirata
Nagoya Institute of Technology
5 shared publications L.C. Fung
Dept. of Electron. Eng., City Univ. of Hong Kong, China
5 shared publications
Latest Publications
- 24 October 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 167 (4) , 642-652
Computational dosimetry for child and adult human models due to contact current from 10 Hz to 110 MHz
This study computationally investigates in situ electric field due to low-frequency contact current and specific absorption rate (SAR) due to high-frequency contact currents in a realistic child model and compared with those in the adult model. The in situ electric fields and SAR in the child model are found to exceed the corresponding values in the adult. At the finger tip, the electric field and SAR due to contact currents, both at the ICNIRP reference levels and IEEE Maximum Permissible Exposures, are well beyond the corresponding basic restrictions. In the remaining part, the largest difference was observed in spinal tissue, and the smallest effect was in the heart. With respect to brain and skin conductivities, one needs to strongly consider which values of tissue properties are used to interpret one's results. The in situ electric fields resulting from contact with the metal plane are similar to those for contact with the wire.
- 24 October 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 167 (4) , 642-652
Computational dosimetry for child and adult human models due to contact current from 10 Hz to 110 MHz
This study computationally investigates in situ electric field due to low-frequency contact current and specific absorption rate (SAR) due to high-frequency contact currents in a realistic child model and compared with those in the adult model. The in situ electric fields and SAR in the child model are found to exceed the corresponding values in the adult. At the finger tip, the electric field and SAR due to contact currents, both at the ICNIRP reference levels and IEEE Maximum Permissible Exposures, are well beyond the corresponding basic restrictions. In the remaining part, the largest difference was observed in spinal tissue, and the smallest effect was in the heart. With respect to brain and skin conductivities, one needs to strongly consider which values of tissue properties are used to interpret one's results. The in situ electric fields resulting from contact with the metal plane are similar to those for contact with the wire.
- 27 June 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (14) , 4001-4003
Corrigendum: Computational dosimetry for grounded and ungrounded human models due to contact current (2013 Phys. Med. Biol. 58 5153–72)
- 27 June 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (14) , 4001-4003
Corrigendum: Computational dosimetry for grounded and ungrounded human models due to contact current (2013 Phys. Med. Biol. 58 5153–72)
- 30 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 12, 579-582
Effects of Phase Difference in Dipole Phased-Array Antenna Above EBG Substrates on SAR
In this letter, we investigate the specific absorption rate (SAR) of a dipole phased-array antenna above an electromagnetic band-gap (EBG) substrate. A two-element array antenna above an EBG substrate is considered for fourth-generation mobile applications at the 3.5-GHz band. The computational results indicate that the use of an EBG substrate in a phased-array antenna can provide an SAR reduction of over 70%. The SAR reduction also depends on the phase difference of the phased-array antenna.
- 30 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 12, 579-582
Effects of Phase Difference in Dipole Phased-Array Antenna Above EBG Substrates on SAR
In this letter, we investigate the specific absorption rate (SAR) of a dipole phased-array antenna above an electromagnetic band-gap (EBG) substrate. A two-element array antenna above an EBG substrate is considered for fourth-generation mobile applications at the 3.5-GHz band. The computational results indicate that the use of an EBG substrate in a phased-array antenna can provide an SAR reduction of over 70%. The SAR reduction also depends on the phase difference of the phased-array antenna.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (10) , 2905-2912
Specific Absorption Rate Evaluation for Passengers Using Wireless Communication Devices Inside Vehicles With Different Handedness, Passenger Counts, and Seating Locations
Radiation from mobile phones inside vehicles, which are semiopen metallic enclosures with irregular shapes and apertures, has been a major concern and has warranted investigation in past years. In this paper, the specific absorption rate (SAR) induced in mobile phone users inside a vehicle was evaluated using different scenarios, including handedness, passenger counts, and seating locations. A computer simulation for SAR distributions in a human body was performed based on the finite-difference time-domain method. The SAR values in mobile phone users in free space were also compared to those inside a vehicle; results illustrated that the maximum SAR induced for mobile phone users in a vehicle is 5% higher than those in free space, but the SAR results showed no significant difference for the handedness. By comparing the SAR values between mobile phone users and nonusers inside a vehicle with a passenger count and seating locations, it was observed that the SAR values around the nonusers' body varied much in different situations, and were higher than those in free space, in some circumstances.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (10) , 2905-2912
Specific Absorption Rate Evaluation for Passengers Using Wireless Communication Devices Inside Vehicles With Different Handedness, Passenger Counts, and Seating Locations
Radiation from mobile phones inside vehicles, which are semiopen metallic enclosures with irregular shapes and apertures, has been a major concern and has warranted investigation in past years. In this paper, the specific absorption rate (SAR) induced in mobile phone users inside a vehicle was evaluated using different scenarios, including handedness, passenger counts, and seating locations. A computer simulation for SAR distributions in a human body was performed based on the finite-difference time-domain method. The SAR values in mobile phone users in free space were also compared to those inside a vehicle; results illustrated that the maximum SAR induced for mobile phone users in a vehicle is 5% higher than those in free space, but the SAR results showed no significant difference for the handedness. By comparing the SAR values between mobile phone users and nonusers inside a vehicle with a passenger count and seating locations, it was observed that the SAR values around the nonusers' body varied much in different situations, and were higher than those in free space, in some circumstances.
- 20 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electromagnetic Compatibility Magazine
- Vol. 1 (1) , 50-54
Development of electromagnetic compatibility courses at the City University of Hong Kong
EMC compliance is a mandatory requirement for electronic and electrical devices export to European countries and the USA. Hong Kong is an export-oriented city with 23% of the total export in electronic and electrical products; knowledge in EMC design and standards are highly desirable to engineers in Hong Kong. To cater for these particular needs of the local industry, EMC was introduced as an undergraduate course in 1994, prior to the effective date of implementation of EMC Directive 89/336/EEC in 1996. After 15-years of development and modification, the EMC course has now become one of the most popular postgraduate courses in Hong Kong. The course includes lectures, EMC standard interpretation, case studies, together with an emphasis on the hands-on experience of EMC tests and facilities in the EMC test laboratory. In this paper, a summary of the development of the EMC course at the City University of Hong Kong in the last decade are presented, and some possible future EMC needs are discussed at the end.
- 20 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electromagnetic Compatibility Magazine
- Vol. 1 (1) , 50-54
Development of electromagnetic compatibility courses at the City University of Hong Kong
EMC compliance is a mandatory requirement for electronic and electrical devices export to European countries and the USA. Hong Kong is an export-oriented city with 23% of the total export in electronic and electrical products; knowledge in EMC design and standards are highly desirable to engineers in Hong Kong. To cater for these particular needs of the local industry, EMC was introduced as an undergraduate course in 1994, prior to the effective date of implementation of EMC Directive 89/336/EEC in 1996. After 15-years of development and modification, the EMC course has now become one of the most popular postgraduate courses in Hong Kong. The course includes lectures, EMC standard interpretation, case studies, together with an emphasis on the hands-on experience of EMC tests and facilities in the EMC test laboratory. In this paper, a summary of the development of the EMC course at the City University of Hong Kong in the last decade are presented, and some possible future EMC needs are discussed at the end.
- 20 June 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (13) , 4447-4458
Dispersive FDTD analysis of induced electric field in human models due to electrostatic discharge
Contact currents flow from/into a charged human body when touching a grounded conductive object. An electrostatic discharge (ESD) or spark may occur just before contact or upon release. The current may stimulate muscles and peripheral nerves. In order to clarify the difference in the induced electric field between different sized human models, the in-situ electric fields were computed in anatomically based models of adults and a child for a contact current in a human body following ESD. A dispersive finite-difference time-domain method was used, in which biological tissue is assumed to obey a four-pole Debye model. From our computational results, the first peak of the discharge current was almost identical across adult and child models. The decay of the induced current in the child was also faster due mainly to its smaller body capacitance compared to the adult models. The induced electric fields in the forefingers were comparable across different models. However, the electric field induced in the arm of the child model was found to be greater than that in the adult models primarily because of its smaller cross-sectional area. The tendency for greater doses in the child has also been reported for power frequency sinusoidal contact current exposures as reported by other investigators.
- 20 June 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (13) , 4447-4458
Dispersive FDTD analysis of induced electric field in human models due to electrostatic discharge
Contact currents flow from/into a charged human body when touching a grounded conductive object. An electrostatic discharge (ESD) or spark may occur just before contact or upon release. The current may stimulate muscles and peripheral nerves. In order to clarify the difference in the induced electric field between different sized human models, the in-situ electric fields were computed in anatomically based models of adults and a child for a contact current in a human body following ESD. A dispersive finite-difference time-domain method was used, in which biological tissue is assumed to obey a four-pole Debye model. From our computational results, the first peak of the discharge current was almost identical across adult and child models. The decay of the induced current in the child was also faster due mainly to its smaller body capacitance compared to the adult models. The induced electric fields in the forefingers were comparable across different models. However, the electric field induced in the arm of the child model was found to be greater than that in the adult models primarily because of its smaller cross-sectional area. The tendency for greater doses in the child has also been reported for power frequency sinusoidal contact current exposures as reported by other investigators.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627673,p. 721-724
Analysis of millimeter wave radiation to human body using inhomogeneous multilayer skin model
A detail inhomogeneous multilayer skin model consists of Asian hair is developed. The Asian hair is modeled as a circular cone with basic radius of 100 μm, and the Cole-Cole equation is applied for estimating the dielectric properties of hair at 60 GHz in the skin model. To simulate the effect of millimeter wave radiation to human body, a radiation source generated by a 60 GHz co-planar waveguide (CPW) fed bowtie aperture antenna is used. This study is formulated by using finite element method (FEM); the electromagnetic field distribution, the induced SAR in the skin layers and blood vessel are investigated. Results have shown that more hair on the skin would decrease the induced specific absorption rate (SAR) in blood vessel in the study presented herein.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627673,p. 721-724
Analysis of millimeter wave radiation to human body using inhomogeneous multilayer skin model
A detail inhomogeneous multilayer skin model consists of Asian hair is developed. The Asian hair is modeled as a circular cone with basic radius of 100 μm, and the Cole-Cole equation is applied for estimating the dielectric properties of hair at 60 GHz in the skin model. To simulate the effect of millimeter wave radiation to human body, a radiation source generated by a 60 GHz co-planar waveguide (CPW) fed bowtie aperture antenna is used. This study is formulated by using finite element method (FEM); the electromagnetic field distribution, the induced SAR in the skin layers and blood vessel are investigated. Results have shown that more hair on the skin would decrease the induced specific absorption rate (SAR) in blood vessel in the study presented herein.
- 11 January 2011
- Published by Wiley in European Transactions on Electrical Power
- Vol. 21 (5) , 1711-1718
Investigation of power frequency magnetic field radiation in typical high-rise building
- 11 January 2011
- Published by Wiley in European Transactions on Electrical Power
- Vol. 21 (5) , 1711-1718
Investigation of power frequency magnetic field radiation in typical high-rise building