CZCunyi Zhao

Cunyi Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cunyi Zhao has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design and Development of Robust, Daylight-Activated, and Rechargeable Biocidal Polymeric Films as Promising Active Food Packaging Materials

    by Shahid Ul Islam, Zheng Zhang, Cunyi Zhao, Nicharee Wisuthiphaet, Nitin Nitin, Gang Sun

    The emerging infectious diseases have created one of the major practical needs to develop active packaging materials with durable antibacterial and antiviral properties for the food industry. To meet this demand, the development of new technologies applicable to food contact surfaces is highly desired but challenging. The recent discovery of the photoactive properties of vitamin K (VK) derivatives has raised great expectations as promising candidates in functional film development due to the generation of biocidal reactive oxygen species (ROS) by these compounds. Inspired by the excellent photoactivity of one of the light-stable VK derivatives, menadione (VK3), under visible daylight irradiation, we demonstrate a protocol for the fabrication of daylight-mediated biocidal packaging materials by incorporating VK3 into a poly (ethylene-co-vinyl acetate) (EVA) matrix. The VK3 (i.e., 1-5% w/w) incorporated EVA films successfully demonstrated the production of ROS and antibacterial and antiviral performance against Escherichia coli, Listeria innocua, and T7 bacteriophage, respectively, under daylight exposure conditions. The results revealed that the addition of a proper percentage of VK3 significantly enhanced the ROS productivity of the films and created a novel daylight-induced microbial killing performance on the films. The biocidal functions of the films are long-lasting and rechargeable when exposed to light repeatedly, making them a viable contender for replacing currently available conventional packaging films.


  • Open Access

    Discovery of Peptidic Ligands against the SARS-CoV-2 Spike Protein and Their Use in the Development of a Highly Sensitive Personal Use Colorimetric COVID-19 Biosensor

    by Xingjian Yu, Bofeng Pan, Cunyi Zhao, Diedra Shorty, Lucas N. Solano, Gang Sun, Ruiwu Liu, Kit S. Lam

    In addition to efficacious vaccines and antiviral therapeutics, reliable and flexible in-home personal use diagnostics for the detection of viral antigens are needed for effective control of the COVID-19 pandemic. Despite the approval of several PCR-based and affinity-based in-home COVID-19 testing kits, many of them suffer from problems such as a high false-negative rate, long waiting time, and short storage period. Using the enabling one-bead-one-compound (OBOC) combinatorial technology, several peptidic ligands with a nanomolar binding affinity toward the SARS-CoV-2 spike protein (S-protein) were successfully discovered. Taking advantage of the high surface area of porous nanofibers, immobilization of these ligands on nanofibrous membranes allows the development of personal use sensors that can achieve low nanomolar sensitivity in the detection of the S-protein in saliva. This simple biosensor employing naked-eye reading exhibits detection sensitivity comparable to some of the current FDA-approved home detection kits. Furthermore, the ligand used in the biosensor was found to detect the S-protein derived from both the original strain and the Delta variant. The workflow reported here may enable us to rapidly respond to the development of home-based biosensors against future viral outbreaks.


  • Improving the Sensitivity of Nanofibrous Membrane-Based ELISA for On-Site Antibiotics Detection

    by Cunyi Zhao, Bofeng Pan, Minyuan Wang, Yang Si, Ameer Y Taha, Gangyu Liu, Tingrui Pan, Gang Sun

    An ultrasensitive and portable colorimetric enzyme-linked immunosorbent assay (ELISA) sensor for antibiotics was fabricated by immobilizing antibodies inside the largely porous and highly hydrophilic nanofibrous membranes. Different from regular electrospun nanofibrous membranes where antibodies may frequently be blocked by the heterogeneous porous structure and sterically crowded loaded on the surface, the controlled microporous structure and increased hydrophilicity of nanofibrous membranes could improve the diffusion properties of antibodies, reduce the sterically crowding effect, and dramatically improve the sensitivity of the membrane-based ELISA. The limitation of detection (LOD) for chloramphenicol (CAP) reached 0.005 ng/mL, around 200 times lower than the conventional paper-based ELISA, making quantitative analysis and portable on-site detection achievable via the use of smartphones. The successful design and fabrication of the nanofibrous membrane-based ELISA with novel features overcome the structural drawbacks of regular electrospun nanofibrous membranes and provide new paths to develop highly sensitive on-site detection of hazardous chemical agents.


  • Sample-to-Answer Robotic ELISA

    by Chuqing Zhou, Zecong Fang, Cunyi Zhao, Xiyan Mai, Shiva Emami, Ameer Y. Taha, Gang Sun, Tingrui Pan

    Enzyme-linked immunosorbent assays (ELISA), as one of the most used immunoassays, have been conducted ubiquitously in hospitals, research laboratories, etc. However, the conventional ELISA procedure is usually laborious, occupies bulky instruments, consumes lengthy operation time, and relies considerably on the skills of technicians, and such limitations call for innovations to develop a fully automated ELISA platform. In this paper, we have presented a system incorporating a robotic-microfluidic interface (RoMI) and a modular hybrid microfluidic chip that embeds a highly sensitive nanofibrous membrane, referred to as the Robotic ELISA, to achieve human-free sample-to-answer ELISA tests in a fully programmable and automated manner. It carries out multiple bioanalytical procedures to replace the manual steps involved in classic ELISA operations, including the pneumatically driven high-precision pipetting, efficient mixing and enrichment enabled by back-and-forth flows, washing, and integrated machine vision for colorimetric readout. The Robotic ELISA platform has achieved a low limit of detection of 0.1 ng/mL in the detection of a low sample volume (15 μL) of chloramphenicol within 20 min without human intervention, which is significantly faster than that of the conventional ELISA procedure. Benefiting from its modular design and automated operations, the Robotic ELISA platform has great potential to be deployed for a broad range of detections in various resource-limited settings or high-risk environments, where human involvement needs to be minimized while the testing timeliness, consistency, and sensitivity are all desired.


  • Diffusion of Protein Molecules through Microporous Nanofibrous Polyacrylonitrile Membranes

    by Cunyi Zhao, Yang Si, Shenghan Zhu, Kevin Bradley, Ameer Y Taha, Tingrui Pan, Gang Sun

    Porous nanofibrous membranes have ultrahigh specific surface areas and could be broadly employed in protein purification, enzyme immobilization, and biosensors with enhanced selectivity, sensitivity, and efficiency. However, large biomolecules, such as proteins, have hindered diffusion behavior in microporous media, significantly reducing the benefits provided by the nanofibrous membranes. The study of protein diffusion in polyacrylonitrile nanofibrous membranes produced under varied humidity and polymer concentration of electrospinning revealed that heterogeneous structures of the nanofibrous membranes possess much smaller effective pore sizes than the measured pore sizes, which significantly affects the diffusion of large molecules through the system though sizes of proteins and pH conditions also have great impacts. Only when the measured membrane pore size is at least 1000 times higher than the protein size, the diffusion behavior of the protein is predictable in the system. The results provide insights into the design and applications of proper nanofibrous materials for improved applications in protein purification and immobilizations.


  • Design and Synthesis of Core–Shell Carbon Polymer Dots with Highly Stable Fluorescence in Polymeric Materials

    by Yuan Yu, Peixin Tang, Bogdan Barnych, Cunyi Zhao, Gang Sun, Mingqiao Ge

    In recent years, fluorescent carbon dots have attracted great attention due to their good luminescence and low toxicity. Here, blue fluorescent core–shell structured carbon polymer dots (CPDs) with high stability under a wide range of pH values, long storage time, and excellent fluorescence in various solvents and even in the solid state were prepared by hydrothermal synthesis of dendritic tris(2-aminoethyl)amine (TAEA) and citric acid. The CPD core structure provides strong fluorescent luminescence; a shell structure of the core possesses a high amount of dendritic primary amino groups connected by ethylene groups to the core. This unique structure prevents aggregation of the cores and the self-quenching effect of CPDs. As a result, the CPDs have high fluorescence in both aqueous and hydrophobic solutions and even as pure solid-state powder. In addition, the CPDs are also insensitive to pH of solutions, and the fluorescence intensity of the solution was stable in the pH range of 4–14. The CPD embedded polymer films and fibers revealed excellent fluorescent properties.


  • Flexible and Washable Poly(Ionic Liquid) Nanofibrous Membrane with Moisture Proof Pressure Sensing for Real-Life Wearable Electronics

    by Zehong Wang, Yang Si, Cunyi Zhao, Dan Yu, Wei Wang, Gang Sun

    Real-life wearable electronics with long-term stable sensing performance are of significant practical interest to public. Wearable pressure sensors with washable, comfortable, breathable and stable sensing ability are a key requirement to meet the desire. However, effects of ubiquitous ambient moisture and intrinsic defects of current capacitive sensing materials are two factors leading to unstable sensing performance of current pressure sensors. Existing ionic liquid-based materials (i.e., ionic hydrogel, ionic film or ionic/elastomers composite) have been used for efficient capacitive-pressure sensing but are highly sensitive and especially affected by moisture. In this work, we introduce a washable capacitive pressure sensing textile based on use of a hydrophobic poly (ionic liquid) nanofibrous membrane (PILNM) with good mechanical properties and satisfactory moisture proof sensing performance. The PILNM membranes possessing rich ions and microporous structures are novel ideal polymeric dielectric materials for amplifications of signals with negligible stimulations. Moreover, the PILNMs exhibit very high stable sensing signals under moisture interference (up to 70% RH) and repeated washings (more than 10 washings), especially suitable for wearable electronics. Notably, the PILNM-based wearable pressure sensing textiles offer high sensitivity for tiny pressure and bent chord length changes with a low-pressure detection limit even under harsh deformations. Owing to the superior performance, the PILNM-based wearable pressure sensing textiles are comfortable to wear and suitable for monitoring different human motions and pulse vibrations at various body positions. Meanwhile, the assembled multiple wearable pressure sensing array can spatially map the contact area of the pressure stimuli and synchronously reflect finger movements.