Daniel Forsberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Forsberg has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
Hans Knutsson
Department of Biomedical Engineering, Linköping University, Sweden
10 shared publicationsMats Andersson
Department of Biomedical Engineering, Linköping University, Sweden
7 shared publicationsBeverly Rosipko
Department of Radiology, Case Western Reserve University and University Hospitals Case Medical Center, Cleveland, OH, USA
5 shared publicationsJeffrey L. Sunshine
Department of Radiology, Case Western Reserve University and University Hospitals Cleveland Medical Center, 11100 Euclid Avenue, Cleveland, OH, 44106, USA
5 shared publications- Claes Lundström
Department of Science and Technology Linköping University Sweden
4 shared publications - Anders Eklund
Department of Biomedical Engineering, Linköping University, Linköping, Sweden
2 shared publications
Latest Publications
- 1 March 2018
- Published by Springer Nature in Spine Deformity
- Vol. 6 (2) , 112-120.e1
Vertebral Axial Asymmetry in Adolescent Idiopathic Scoliosis
Retrospective study. To investigate parameters of axial vertebral deformation in patients with scoliosis compared to a control group, and to determine whether these parameters correlated with the severity of spine curvature, measured as the Cobb angle. Adolescent idiopathic scoliosis (AIS) is the most common type of spinal deformity. Many studies have investigated vertebral deformation, in terms of wedging and pedicle deformations, but few studies have investigated actual structural changes within vertebrae. This study included 20 patients with AIS (Lenke 1–3, mean age: 15.6 years, range: 11–20). We compared preoperative low-dose computed tomography (CT) examinations of patients with AIS to those of a control group matched for age and sex. The control individuals had no spinal deformity, but they were admitted to the emergency department for trauma CTs. We measured the Cobb angles and the axial vertebral rotation (AVR), axial vertebral body asymmetry (AVBA), and frontal vertebral body rotation (FVBR) for the superior end, inferior end, and apical vertebrae, with in-house–developed software. Correlations between entities were investigated with the Pearson correlation test. The average Cobb angles were 49.3° and 1.3° for the scoliotic and control groups, respectively. The patient and control groups showed significant differences in the AVRs of all three vertebra levels (p < .01), the AVBAs of the superior end and apical vertebrae (p < .008), and the FVBR of the apical vertebra (p = .011). Correlations were only found between the AVBA and FVBR in the superior end vertebra (r = 0.728, p < .001) and in the apical vertebra (r = 0.713, p < .001). Compared with controls, patients with scoliosis showed clear morphologic differences in the midaxial plane vertebrae. Differences in AVR, AVBA, and FVBR were most pronounced at the apical vertebra. The FVBR provided valuable additional information about the internal rotation and deformation of vertebrae. Level III.
- 1 March 2018
- Published by Springer Nature in Spine Deformity
- Vol. 6 (2) , 112-120.e1
Vertebral Axial Asymmetry in Adolescent Idiopathic Scoliosis
Retrospective study. To investigate parameters of axial vertebral deformation in patients with scoliosis compared to a control group, and to determine whether these parameters correlated with the severity of spine curvature, measured as the Cobb angle. Adolescent idiopathic scoliosis (AIS) is the most common type of spinal deformity. Many studies have investigated vertebral deformation, in terms of wedging and pedicle deformations, but few studies have investigated actual structural changes within vertebrae. This study included 20 patients with AIS (Lenke 1–3, mean age: 15.6 years, range: 11–20). We compared preoperative low-dose computed tomography (CT) examinations of patients with AIS to those of a control group matched for age and sex. The control individuals had no spinal deformity, but they were admitted to the emergency department for trauma CTs. We measured the Cobb angles and the axial vertebral rotation (AVR), axial vertebral body asymmetry (AVBA), and frontal vertebral body rotation (FVBR) for the superior end, inferior end, and apical vertebrae, with in-house–developed software. Correlations between entities were investigated with the Pearson correlation test. The average Cobb angles were 49.3° and 1.3° for the scoliotic and control groups, respectively. The patient and control groups showed significant differences in the AVRs of all three vertebra levels (p < .01), the AVBAs of the superior end and apical vertebrae (p < .008), and the FVBR of the apical vertebra (p = .011). Correlations were only found between the AVBA and FVBR in the superior end vertebra (r = 0.728, p < .001) and in the apical vertebra (r = 0.713, p < .001). Compared with controls, patients with scoliosis showed clear morphologic differences in the midaxial plane vertebrae. Differences in AVR, AVBA, and FVBR were most pronounced at the apical vertebra. The FVBR provided valuable additional information about the internal rotation and deformation of vertebrae. Level III.
- 12 January 2017
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 30 (4) , 406-412
Detection and Labeling of Vertebrae in MR Images Using Deep Learning with Clinical Annotations as Training Data
The purpose of this study was to investigate the potential of using clinically provided spine label annotations stored in a single institution image archive as training data for deep learning-based vertebral detection and labeling pipelines. Lumbar and cervical magnetic resonance imaging cases with annotated spine labels were identified and exported from an image archive. Two separate pipelines were configured and trained for lumbar and cervical cases respectively, using the same setup with convolutional neural networks for detection and parts-based graphical models to label the vertebrae. The detection sensitivity, precision and accuracy rates ranged between 99.1–99.8, 99.6–100, and 98.8–99.8% respectively, the average localization error ranges were 1.18–1.24 and 2.38–2.60 mm for cervical and lumbar cases respectively, and with a labeling accuracy of 96.0–97.0%. Failed labeling results typically involved failed S1 detections or missed vertebrae that were not fully visible on the image. These results show that clinically annotated image data from one image archive is sufficient to train a deep learning-based pipeline for accurate detection and labeling of MR images depicting the spine. Further, these results support using deep learning to assist radiologists in their work by providing highly accurate labels that only require rapid confirmation.
- 12 January 2017
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 30 (4) , 406-412
Detection and Labeling of Vertebrae in MR Images Using Deep Learning with Clinical Annotations as Training Data
The purpose of this study was to investigate the potential of using clinically provided spine label annotations stored in a single institution image archive as training data for deep learning-based vertebral detection and labeling pipelines. Lumbar and cervical magnetic resonance imaging cases with annotated spine labels were identified and exported from an image archive. Two separate pipelines were configured and trained for lumbar and cervical cases respectively, using the same setup with convolutional neural networks for detection and parts-based graphical models to label the vertebrae. The detection sensitivity, precision and accuracy rates ranged between 99.1–99.8, 99.6–100, and 98.8–99.8% respectively, the average localization error ranges were 1.18–1.24 and 2.38–2.60 mm for cervical and lumbar cases respectively, and with a labeling accuracy of 96.0–97.0%. Failed labeling results typically involved failed S1 detections or missed vertebrae that were not fully visible on the image. These results show that clinically annotated image data from one image archive is sufficient to train a deep learning-based pipeline for accurate detection and labeling of MR images depicting the spine. Further, these results support using deep learning to assist radiologists in their work by providing highly accurate labels that only require rapid confirmation.
- 1 January 2017
- Published by Elsevier in Medical Image Analysis
- Vol. 35, 327-344
Evaluation and comparison of 3D intervertebral disc localization and segmentation methods for 3D T2 MR data: A grand challenge
- 1 January 2017
- Published by Elsevier in Medical Image Analysis
- Vol. 35, 327-344
Evaluation and comparison of 3D intervertebral disc localization and segmentation methods for 3D T2 MR data: A grand challenge
- 26 November 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (3) , 431-438
Synchronized navigation of current and prior studies using image registration improves radiologist’s efficiency
The purpose of this study was to investigate how the use of multi-modal rigid image registration integrated within a standard picture archiving and communication system affects the efficiency of a radiologist while performing routine interpretations of cases including prior examinations.
- 26 November 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (3) , 431-438
Synchronized navigation of current and prior studies using image registration improves radiologist’s efficiency
The purpose of this study was to investigate how the use of multi-modal rigid image registration integrated within a standard picture archiving and communication system affects the efficiency of a radiologist while performing routine interpretations of cases including prior examinations.
- 20 October 2016
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 30 (2) , 133-140
Improved Screening Mammogram Workflow by Maximizing PACS Streamlining Capabilities in an Academic Breast Center
The aim of this study was to perform an operational improvement project targeted at the breast imaging reading workflow of mammography examinations at an academic medical center with its associated breast centers and satellite sites. Through careful analysis of the current workflow, two major issues were identified: stockpiling of paperwork and multiple worklists. Both issues were considered to cause significant delays to the start of interpreting screening mammograms. Four workflow changes were suggested (scanning of paperwork, worklist consolidation, use of chat functionality, and tracking of case distribution among trainees) and implemented in July 2015. Timestamp data was collected 2 months before (May–Jun) and after (Aug–Sep) the implemented changes. Generalized linear models were used to analyze the data. The results showed significant improvements for the interpretation of screening mammograms. The average time elapsed for time to open a case reduced from 70 to 28 min (60 % decrease, p < 0.001), report turn-around time with preliminary signature decreased from 151 to 107 min (29 % decrease, p < 0.001), and report turn-around time final signature from 153 to 139 min (9 % decrease, p = 0.002). These improvements were achieved while keeping the efficiency of the workflow for diagnostic mammograms at large unaltered even with increased volume of mammography examinations (31 % increase of 4344 examinations for May–Jun to 5678 examinations for Aug–Sep). In conclusion, targeted efforts to improve the breast imaging reading workflow for screening mammograms in a teaching environment provided significant performance improvements without affecting the workflow of diagnostic mammograms.
- 20 October 2016
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 30 (2) , 133-140
Improved Screening Mammogram Workflow by Maximizing PACS Streamlining Capabilities in an Academic Breast Center
The aim of this study was to perform an operational improvement project targeted at the breast imaging reading workflow of mammography examinations at an academic medical center with its associated breast centers and satellite sites. Through careful analysis of the current workflow, two major issues were identified: stockpiling of paperwork and multiple worklists. Both issues were considered to cause significant delays to the start of interpreting screening mammograms. Four workflow changes were suggested (scanning of paperwork, worklist consolidation, use of chat functionality, and tracking of case distribution among trainees) and implemented in July 2015. Timestamp data was collected 2 months before (May–Jun) and after (Aug–Sep) the implemented changes. Generalized linear models were used to analyze the data. The results showed significant improvements for the interpretation of screening mammograms. The average time elapsed for time to open a case reduced from 70 to 28 min (60 % decrease, p < 0.001), report turn-around time with preliminary signature decreased from 151 to 107 min (29 % decrease, p < 0.001), and report turn-around time final signature from 153 to 139 min (9 % decrease, p = 0.002). These improvements were achieved while keeping the efficiency of the workflow for diagnostic mammograms at large unaltered even with increased volume of mammography examinations (31 % increase of 4344 examinations for May–Jun to 5678 examinations for Aug–Sep). In conclusion, targeted efforts to improve the breast imaging reading workflow for screening mammograms in a teaching environment provided significant performance improvements without affecting the workflow of diagnostic mammograms.
- 6 October 2016
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 30 (1) , 86-94
Radiologists’ Variation of Time to Read Across Different Procedure Types
The workload of US radiologists has increased over the past two decades as measured through total annual relative value units (RVUs). This increase in RVUs generated suggests that radiologists’ productivity has increased. However, true productivity (output unit per input unit; RVU per time) is at large unknown since actual time required to interpret and report a case is rarely recorded. In this study, we analyzed how the time to read a case varies between radiologists over a set of different procedure types by retrospectively extracting reading times from PACS usage logs. Specifically, we tested two hypotheses that; i) relative variation in time to read per procedure type increases as the median time to read a procedure type increases, and ii) relative rankings in terms of median reading speed for individual radiologists are consistent across different procedure types. The results that, i) a correlation of -0.25 between the coefficient of variation and median time to read and ii) that only 12 out of 46 radiologists had consistent rankings in terms of time to read across different procedure types, show both hypotheses to be without support. The results show that workload distribution will not follow any general rule for a radiologist across all procedures or a general rule for a specific procedure across many readers. Rather the findings suggest that improved overall practice efficiency can be achieved only by taking into account radiologists’ individual productivity per procedure type when distributing unread cases.
- 6 October 2016
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 30 (1) , 86-94
Radiologists’ Variation of Time to Read Across Different Procedure Types
The workload of US radiologists has increased over the past two decades as measured through total annual relative value units (RVUs). This increase in RVUs generated suggests that radiologists’ productivity has increased. However, true productivity (output unit per input unit; RVU per time) is at large unknown since actual time required to interpret and report a case is rarely recorded. In this study, we analyzed how the time to read a case varies between radiologists over a set of different procedure types by retrospectively extracting reading times from PACS usage logs. Specifically, we tested two hypotheses that; i) relative variation in time to read per procedure type increases as the median time to read a procedure type increases, and ii) relative rankings in terms of median reading speed for individual radiologists are consistent across different procedure types. The results that, i) a correlation of -0.25 between the coefficient of variation and median time to read and ii) that only 12 out of 46 radiologists had consistent rankings in terms of time to read across different procedure types, show both hypotheses to be without support. The results show that workload distribution will not follow any general rule for a radiologist across all procedures or a general rule for a specific procedure across many readers. Rather the findings suggest that improved overall practice efficiency can be achieved only by taking into account radiologists’ individual productivity per procedure type when distributing unread cases.
- 1 July 2016
- Published by Springer Nature
- p. 107-116
Segmentation of Intervertebral Discs in 3D MRI Data Using Multi-atlas Based Registration
- 1 July 2016
- Published by Springer Nature
- p. 107-116
Segmentation of Intervertebral Discs in 3D MRI Data Using Multi-atlas Based Registration
- 1 July 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (7) , 812-818.e2
State of Integration Between PACS and Other IT Systems: A National Survey of Academic Radiology Departments
- 1 July 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 13 (7) , 812-818.e2
State of Integration Between PACS and Other IT Systems: A National Survey of Academic Radiology Departments
- 20 April 2016
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 29 (6) , 670-676
Factors Affecting Radiologist’s PACS Usage
The purpose of this study was to determine if any of the factors radiologist, examination category, time of week, and week effect PACS usage, with PACS usage defined as the sequential order of computer commands issued by a radiologist in a PACS during interpretation and dictation. We initially hypothesized that only radiologist and examination category would have significant effects on PACS usage. Command logs covering 8 weeks of PACS usage were analyzed. For each command trace (describing performed activities of an attending radiologist interpreting a single examination), the PACS usage variables number of commands, number of command classes, bigram repetitiveness, and time to read were extracted. Generalized linear models were used to determine the significance of the factors on the PACS usage variables. The statistical results confirmed the initial hypothesis that radiologist and examination category affect PACS usage and that the factors week and time of week to a large extent have no significant effect. As such, this work provides direction for continued efforts to analyze system data to better understand PACS utilization, which in turn can provide input to enable optimal utilization and configuration of corresponding systems. These continued efforts were, in this work, exemplified by a more detailed analysis using PACS usage profiles, which revealed insights directly applicable to improve PACS utilization through modified system configuration.
- 20 April 2016
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 29 (6) , 670-676
Factors Affecting Radiologist’s PACS Usage
The purpose of this study was to determine if any of the factors radiologist, examination category, time of week, and week effect PACS usage, with PACS usage defined as the sequential order of computer commands issued by a radiologist in a PACS during interpretation and dictation. We initially hypothesized that only radiologist and examination category would have significant effects on PACS usage. Command logs covering 8 weeks of PACS usage were analyzed. For each command trace (describing performed activities of an attending radiologist interpreting a single examination), the PACS usage variables number of commands, number of command classes, bigram repetitiveness, and time to read were extracted. Generalized linear models were used to determine the significance of the factors on the PACS usage variables. The statistical results confirmed the initial hypothesis that radiologist and examination category affect PACS usage and that the factors week and time of week to a large extent have no significant effect. As such, this work provides direction for continued efforts to analyze system data to better understand PACS utilization, which in turn can provide input to enable optimal utilization and configuration of corresponding systems. These continued efforts were, in this work, exemplified by a more detailed analysis using PACS usage profiles, which revealed insights directly applicable to improve PACS utilization through modified system configuration.
- 1 April 2016
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 49, 16-28
A multi-center milestone study of clinical vertebral CT segmentation
- 1 April 2016
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 49, 16-28
A multi-center milestone study of clinical vertebral CT segmentation