Tasuku Fujii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tasuku Fujii has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Kimitoshi Nishiwaki
Department of Anesthesiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
13 shared publications- Kimitoshi Nishiwaki
Department of Anesthesiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
7 shared publications Shogo Suzuki
Department of Anesthesiology, Nagoya University Hospital, Nagoya, Japan
6 shared publicationsTomoya Taniguchi
Department of Anesthesiology, Nagoya University Hospital, Nagoya, Japan
6 shared publicationsMasashi Takakura
Department of Anesthesiology, Nagoya University Hospital, Nagoya, Japan
5 shared publicationsK. Nishiwaki
Nagoya University Graduate School of Medicine, Nagoya, Japan
4 shared publications
Latest Publications
- Open Access
- 19 September 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-11
Effect of combination therapy with recombinant thrombomodulin and antithrombin on outcomes in patients with sepsis-induced disseminated intravascular coagulation in a surgical intensive care unit: a retrospective observational study
- 19 September 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-11
Open AccessEffect of combination therapy with recombinant thrombomodulin and antithrombin on outcomes in patients with sepsis-induced disseminated intravascular coagulation in a surgical intensive care unit: a retrospective observational study
- 22 March 2025
- Published by Springer Nature in Journal of Anesthesia
- Vol. 39 (4) , 664-665
Reply to the letter by Moradi M and Cheraghi MR
- 22 March 2025
- Published by Springer Nature in Journal of Anesthesia
- Vol. 39 (4) , 664-665
Reply to the letter by Moradi M and Cheraghi MR
- Open Access
- 11 September 2024
- Published by Springer Nature in Journal of Anesthesia
- Vol. 38 (6) , 848-854
Accuracy of non-invasive core temperature monitoring in infant and toddler patients: a prospective observational study
Purpose: Careful perioperative temperature management is important because it influences clinical outcomes. In pediatric patients, the esophageal temperature is the most accurate indicator of core temperature. However, it requires probe insertion into the body cavity, which is mildly invasive. Therefore, a non-invasive easily and continuously temperature monitor system is ideal. This study aimed to assess the accuracy of Temple Touch Pro™ (TTP), a non-invasive temperature monitoring using the heat flux technique, compared with esophageal (Tesoph) and rectal (Trect) temperature measurements in pediatric patients, especially in infants and toddlers. Methods: This single-center prospective observational study included 40 pediatric patients (< 3 years old) who underwent elective non-cardiac surgery. The accuracy of TTP was analyzed using Bland–Altman analysis and compared with Tesoph or Trect temperature measurements. The error was within ± 0.5 °C and was considered clinically acceptable. Results: The bias ± precision between TTP and Tesoph was 0.09 ± 0.28 °C, and 95% limits of agreement were – 0.48 to 0.65 °C (error within ± 0.5 °C: 94.0%). The bias ± precision between TTP and Trect was 0.41 ± 0.38 °C and 95% limits of agreement were – 0.35 to 1.17 °C (error within ± 0.5 °C: 68.5%). In infants, bias ± precision with 95% limits of agreement were 0.10 ± 0.30 °C with – 0.50 to 0.69 °C (TTP vs. Tesoph) and 0.35 ± 0.29 °C with – 0.23 to 0.92 °C (TTP vs. Trect). Conclusion: Core temperature measurements using TTP in infants and toddlers were more accurate with Tesoph than with Trect. In the future, non-invasive TTP temperature monitoring will help perioperative temperature management in pediatric patients.
- 11 September 2024
- Published by Springer Nature in Journal of Anesthesia
- Vol. 38 (6) , 848-854
Open AccessAccuracy of non-invasive core temperature monitoring in infant and toddler patients: a prospective observational study
Purpose: Careful perioperative temperature management is important because it influences clinical outcomes. In pediatric patients, the esophageal temperature is the most accurate indicator of core temperature. However, it requires probe insertion into the body cavity, which is mildly invasive. Therefore, a non-invasive easily and continuously temperature monitor system is ideal. This study aimed to assess the accuracy of Temple Touch Pro™ (TTP), a non-invasive temperature monitoring using the heat flux technique, compared with esophageal (Tesoph) and rectal (Trect) temperature measurements in pediatric patients, especially in infants and toddlers. Methods: This single-center prospective observational study included 40 pediatric patients (< 3 years old) who underwent elective non-cardiac surgery. The accuracy of TTP was analyzed using Bland–Altman analysis and compared with Tesoph or Trect temperature measurements. The error was within ± 0.5 °C and was considered clinically acceptable. Results: The bias ± precision between TTP and Tesoph was 0.09 ± 0.28 °C, and 95% limits of agreement were – 0.48 to 0.65 °C (error within ± 0.5 °C: 94.0%). The bias ± precision between TTP and Trect was 0.41 ± 0.38 °C and 95% limits of agreement were – 0.35 to 1.17 °C (error within ± 0.5 °C: 68.5%). In infants, bias ± precision with 95% limits of agreement were 0.10 ± 0.30 °C with – 0.50 to 0.69 °C (TTP vs. Tesoph) and 0.35 ± 0.29 °C with – 0.23 to 0.92 °C (TTP vs. Trect). Conclusion: Core temperature measurements using TTP in infants and toddlers were more accurate with Tesoph than with Trect. In the future, non-invasive TTP temperature monitoring will help perioperative temperature management in pediatric patients.
- 4 September 2024
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 141 (4) , 801-806
Evaluation of the Noninvasive Estimated Continuous Cardiac Output System for Pediatric Patients: A Prospective Observational Study
BACKGROUND: The estimated continuous cardiac output (esCCO) system is a hemodynamic monitor that uses electrocardiograms and pulse oximeter waves to noninvasively estimate cardiac output. The coefficients for esCCO measurement have been established for adult patients, but the appropriate coefficients for pediatric patients are unclear. Therefore, this study determined esCCO coefficients for pediatric patients and validated the accuracy and tracking ability of a modified esCCO system. METHODS: An initial study compared cardiac output measurements using transthoracic echocardiography and esCCO in 60 pediatric patients aged <15 years who underwent elective noncardiac surgery. Consequently, the coefficients for the esCCO measurements were redefined for pediatric patients. The main study compared cardiac output measurements between transthoracic echocardiography and modified esCCO in 80 pediatric patients. Measurements were performed pre- and postoperatively, and the accuracy and trending ability of the cardiac output measurements were evaluated using Bland-Altman analysis and a polar plot. RESULTS: The correlation coefficients between the modified esCCO and transthoracic echocardiography were 0.96 and 0.98 in the pre- and postoperative measurements, respectively. In Bland-Altman analysis, the bias (standard deviation [SD]), 95% limits of agreement, and percentage error were 0.03 (0.28), −0.53 to 0.60, and 18% in the preoperative measurement, and −0.04 (0.19), –0.42 to 0.35, and 15% in the postoperative measurement, respectively. The polar plot showed that the cardiac output changes were well tracked, with an angular bias (SD) of 2.9° (6.0°) and radial 95% limits of agreement ranging from −9.2° to 14.9°. CONCLUSIONS: Cardiac output measurement by esCCO with modified coefficients for pediatric patients showed high accuracy and tracking ability compared with cardiac output measurement by transthoracic echocardiography. This noninvasive cardiac output measurement could benefit perioperative hemodynamic monitoring in children.
- 4 September 2024
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 141 (4) , 801-806
Evaluation of the Noninvasive Estimated Continuous Cardiac Output System for Pediatric Patients: A Prospective Observational Study
BACKGROUND: The estimated continuous cardiac output (esCCO) system is a hemodynamic monitor that uses electrocardiograms and pulse oximeter waves to noninvasively estimate cardiac output. The coefficients for esCCO measurement have been established for adult patients, but the appropriate coefficients for pediatric patients are unclear. Therefore, this study determined esCCO coefficients for pediatric patients and validated the accuracy and tracking ability of a modified esCCO system. METHODS: An initial study compared cardiac output measurements using transthoracic echocardiography and esCCO in 60 pediatric patients aged <15 years who underwent elective noncardiac surgery. Consequently, the coefficients for the esCCO measurements were redefined for pediatric patients. The main study compared cardiac output measurements between transthoracic echocardiography and modified esCCO in 80 pediatric patients. Measurements were performed pre- and postoperatively, and the accuracy and trending ability of the cardiac output measurements were evaluated using Bland-Altman analysis and a polar plot. RESULTS: The correlation coefficients between the modified esCCO and transthoracic echocardiography were 0.96 and 0.98 in the pre- and postoperative measurements, respectively. In Bland-Altman analysis, the bias (standard deviation [SD]), 95% limits of agreement, and percentage error were 0.03 (0.28), −0.53 to 0.60, and 18% in the preoperative measurement, and −0.04 (0.19), –0.42 to 0.35, and 15% in the postoperative measurement, respectively. The polar plot showed that the cardiac output changes were well tracked, with an angular bias (SD) of 2.9° (6.0°) and radial 95% limits of agreement ranging from −9.2° to 14.9°. CONCLUSIONS: Cardiac output measurement by esCCO with modified coefficients for pediatric patients showed high accuracy and tracking ability compared with cardiac output measurement by transthoracic echocardiography. This noninvasive cardiac output measurement could benefit perioperative hemodynamic monitoring in children.
- Open Access
- 1 December 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (48) , e36465
Intraoperative hypotension affects postoperative acute kidney injury depending on the invasiveness of abdominal surgery: A retrospective cohort study
Intraoperative hypotension (IOH) or highly invasive surgery adversely affects postoperative clinical outcomes. It is, however, unclear whether IOH affects postoperative acute kidney injury (AKI) depending on the invasiveness of abdominal surgery. We speculated that IOH in highly invasive abdominal surgery is a significant risk factor for postoperative AKI. We retrospectively reviewed the data of 448 patients who underwent abdominal surgery. Patients were divided into 3 groups: highly (such as pancreaticoduodenectomy and hepatectomy), moderately (open abdominal surgery), and minimally (laparoscopic surgery) invasive surgeries. The association between the time-weighted average (TWA) of mean arterial pressure (MAP) values (≤60 and ≤ 55 mm Hg) and AKI occurrences in each group was assessed. Postoperative AKI occurred after highly, moderately, and minimally invasive surgeries in 33 of 222 (14.9%), 14 of 110 (12.7%), and 12 of 116 (10.3%) cases, respectively (P = .526). The median [interquartile range] of TWA-MAP ≤ 60 mm Hg, as an IOH parameter, was 0.94 [0.33–2.08] mm Hg in highly, 0.54 [0.16–1.46] mm Hg in moderately, and 0.14 [0.03–0.57] mm Hg in minimally invasive surgeries (P < 0001). In addition, there was a significant association between TWA-MAP and AKI in highly invasive surgery, unlike in moderately and minimally invasive surgery, with adjusted odds ratios (95% confidence interval) for TWA-MAP ≤ 60 and ≤ 55 mm Hg associated with AKI of 1.23 [1.00–1.52] (P = .049) and 1.55 [1.02–2.36] (P = .041), respectively. Intraoperative MAP ≤ 60 mm Hg in highly invasive abdominal surgery is associated with postoperative AKI, compared to moderately and minimally invasive surgeries. Additionally, low MAP thresholds in highly invasive surgery increase postoperative AKI risk.
- 1 December 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (48) , e36465
Open AccessIntraoperative hypotension affects postoperative acute kidney injury depending on the invasiveness of abdominal surgery: A retrospective cohort study
Intraoperative hypotension (IOH) or highly invasive surgery adversely affects postoperative clinical outcomes. It is, however, unclear whether IOH affects postoperative acute kidney injury (AKI) depending on the invasiveness of abdominal surgery. We speculated that IOH in highly invasive abdominal surgery is a significant risk factor for postoperative AKI. We retrospectively reviewed the data of 448 patients who underwent abdominal surgery. Patients were divided into 3 groups: highly (such as pancreaticoduodenectomy and hepatectomy), moderately (open abdominal surgery), and minimally (laparoscopic surgery) invasive surgeries. The association between the time-weighted average (TWA) of mean arterial pressure (MAP) values (≤60 and ≤ 55 mm Hg) and AKI occurrences in each group was assessed. Postoperative AKI occurred after highly, moderately, and minimally invasive surgeries in 33 of 222 (14.9%), 14 of 110 (12.7%), and 12 of 116 (10.3%) cases, respectively (P = .526). The median [interquartile range] of TWA-MAP ≤ 60 mm Hg, as an IOH parameter, was 0.94 [0.33–2.08] mm Hg in highly, 0.54 [0.16–1.46] mm Hg in moderately, and 0.14 [0.03–0.57] mm Hg in minimally invasive surgeries (P < 0001). In addition, there was a significant association between TWA-MAP and AKI in highly invasive surgery, unlike in moderately and minimally invasive surgery, with adjusted odds ratios (95% confidence interval) for TWA-MAP ≤ 60 and ≤ 55 mm Hg associated with AKI of 1.23 [1.00–1.52] (P = .049) and 1.55 [1.02–2.36] (P = .041), respectively. Intraoperative MAP ≤ 60 mm Hg in highly invasive abdominal surgery is associated with postoperative AKI, compared to moderately and minimally invasive surgeries. Additionally, low MAP thresholds in highly invasive surgery increase postoperative AKI risk.
- 11 March 2023
- Published by Springer Nature in Journal of Anesthesia
- Vol. 37 (3) , 394-400
Accuracy of a noninvasive estimated continuous cardiac output measurement under different respiratory conditions: a prospective observational study
Purpose The estimated continuous cardiac output (esCCO) system was recently developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared to TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO. Methods Forty patients who had undergone cardiac surgery with a pulmonary artery catheter were enrolled. We compared the esCCO with TDCO from mechanical ventilation to spontaneous respiration through extubation. Patients undergoing cardiac pacing during esCCO measurement, those receiving treatment with an intra-aortic balloon pump, and those with measurement errors or missing data were excluded. In total, 23 patients were included. Agreement between the esCCO and TDCO measurements was evaluated using Bland–Altman analysis with a 20 min moving average of the esCCO. Results The paired esCCO and TDCO measurements (939 points before extubation and 1112 points after extubation) were compared. The respective bias and standard deviation (SD) values were 0.13 L/min and 0.60 L/min before extubation, and − 0.48 L/min and 0.78 L/min after extubation. There was a significant difference in bias before and after extubation (P < 0.001); the SD before and after extubation was not significant (P = 0.315). The percentage errors were 25.1% before extubation and 29.6% after extubation, which is the criterion for acceptance of a new technique. Conclusion The accuracy of the esCCO system is clinically acceptable to that of TDCO under mechanical ventilation and spontaneous respiration.
- 11 March 2023
- Published by Springer Nature in Journal of Anesthesia
- Vol. 37 (3) , 394-400
Accuracy of a noninvasive estimated continuous cardiac output measurement under different respiratory conditions: a prospective observational study
Purpose The estimated continuous cardiac output (esCCO) system was recently developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared to TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO. Methods Forty patients who had undergone cardiac surgery with a pulmonary artery catheter were enrolled. We compared the esCCO with TDCO from mechanical ventilation to spontaneous respiration through extubation. Patients undergoing cardiac pacing during esCCO measurement, those receiving treatment with an intra-aortic balloon pump, and those with measurement errors or missing data were excluded. In total, 23 patients were included. Agreement between the esCCO and TDCO measurements was evaluated using Bland–Altman analysis with a 20 min moving average of the esCCO. Results The paired esCCO and TDCO measurements (939 points before extubation and 1112 points after extubation) were compared. The respective bias and standard deviation (SD) values were 0.13 L/min and 0.60 L/min before extubation, and − 0.48 L/min and 0.78 L/min after extubation. There was a significant difference in bias before and after extubation (P < 0.001); the SD before and after extubation was not significant (P = 0.315). The percentage errors were 25.1% before extubation and 29.6% after extubation, which is the criterion for acceptance of a new technique. Conclusion The accuracy of the esCCO system is clinically acceptable to that of TDCO under mechanical ventilation and spontaneous respiration.
- Open Access
- 1 March 2023
- Published by Springer Nature in Research Square
Accuracy of a noninvasive estimated continuous cardiac output measurement under different respiratory conditions: A prospective observational study
Purpose Recently, the estimated continuous cardiac output (esCCO) system was developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared with TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO. Methods Forty patients who had undergone cardiac surgery with a pulmonary artery catheter were enrolled. We compared the esCCO with TDCO from mechanical ventilation to spontaneous respiration through extubation. Patients undergoing cardiac pacing during esCCO measurement, those receiving treatment with an intra-aortic balloon pump, and those with measurement errors or missing data were excluded. In total, 23 patients were included. Agreement between the esCCO and TDCO measurements was evaluated using Bland–Altman analysis with a 20-minute moving average of the esCCO. Results The paired esCCO and TDCO measurements (939 points before extubation and 1112 points after extubation) were compared. The respective bias and standard deviation (SD) values were 0.13 L/min and 0.60 L/min before extubation and −0.48 L/min and 0.78 L/min after extubation. There was a significant difference in bias before and after extubation (P<0.001); the SD before and after extubation was not significant (P=0.315). The percentage errors were 25.1% before extubation and 29.6% after extubation, which is the criterion for acceptance of a new technique. Conclusion The accuracy of esCCO system is clinically acceptable to that of TDCO under mechanical ventilation and spontaneous respiration.
- 1 March 2023
- Published by Springer Nature in Research Square
Open AccessAccuracy of a noninvasive estimated continuous cardiac output measurement under different respiratory conditions: A prospective observational study
Purpose Recently, the estimated continuous cardiac output (esCCO) system was developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared with TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO. Methods Forty patients who had undergone cardiac surgery with a pulmonary artery catheter were enrolled. We compared the esCCO with TDCO from mechanical ventilation to spontaneous respiration through extubation. Patients undergoing cardiac pacing during esCCO measurement, those receiving treatment with an intra-aortic balloon pump, and those with measurement errors or missing data were excluded. In total, 23 patients were included. Agreement between the esCCO and TDCO measurements was evaluated using Bland–Altman analysis with a 20-minute moving average of the esCCO. Results The paired esCCO and TDCO measurements (939 points before extubation and 1112 points after extubation) were compared. The respective bias and standard deviation (SD) values were 0.13 L/min and 0.60 L/min before extubation and −0.48 L/min and 0.78 L/min after extubation. There was a significant difference in bias before and after extubation (P<0.001); the SD before and after extubation was not significant (P=0.315). The percentage errors were 25.1% before extubation and 29.6% after extubation, which is the criterion for acceptance of a new technique. Conclusion The accuracy of esCCO system is clinically acceptable to that of TDCO under mechanical ventilation and spontaneous respiration.
- Open Access
- 1 November 2022
- Published by Japanese Society of Intensive Care Medicine in Journal of the Japanese Society of Intensive Care Medicine
- Vol. 29 (6) , 601-602
Favorable glycemic control using artificial pancreas STG®-55 for severe perioperative hyperglycemia in a patient with infected abdominal aortic aneurysm: a case report
- 1 November 2022
- Published by Japanese Society of Intensive Care Medicine in Journal of the Japanese Society of Intensive Care Medicine
- Vol. 29 (6) , 601-602
Open AccessFavorable glycemic control using artificial pancreas STG®-55 for severe perioperative hyperglycemia in a patient with infected abdominal aortic aneurysm: a case report
- 18 October 2022
- Published by Wiley in Artificial Organs
- Vol. 47 (6) , 982-989
Effect of intensive insulin therapy on inflammatory response after cardiac surgery using bedside artificial pancreas: A propensity score‐matched analysis
Background Perioperative hyperglycemia leads to poor postoperative clinical outcomes, including compromised immune function, cardiovascular events, and mortality. The optimal perioperative blood glucose levels during cardiac surgery remain unclear. A closed-loop glycemic control system (artificial pancreas, target blood glucose range:120-150 mg/dl) prevents postoperative inflammatory response more effectively than conventional insulin therapy (<200 mg/dl). However, the clinical effects of intensive insulin therapy with strict glycemic control (80-110 mg/dl) are controversial. This study aimed to determine whether intensive insulin therapy would further suppress postoperative inflammatory reactions. Methods This study analyzed 262 patients who underwent cardiovascular surgery with cardiopulmonary bypass. The patients were divided into two groups according to their target blood glucose range: 80-110 mg/dl and 120-150 mg/dl. The primary outcome was the difference in the C-reactive protein levels between the two groups. Results Propensity score matching resulted in 95 patients in each group based on their covariates. There was no difference in the postoperative maximum C-reactive protein levels between the two groups (14.81 +/- 5.93 mg/dl vs. 14.34 +/- 5.52 mg/dl; p = 0.571) following propensity score matching. Hypoglycemia did not occur during intensive insulin therapy. Conclusions Intensive insulin therapy following cardiac surgery with cardiopulmonary bypass did not demonstrate significant advantages in the suppression of postoperative inflammatory reactions compared to that with mild glycemic control. However, intensive insulin therapy using an artificial pancreas was found to be safe, with no hypoglycemic events.
- 18 October 2022
- Published by Wiley in Artificial Organs
- Vol. 47 (6) , 982-989
Effect of intensive insulin therapy on inflammatory response after cardiac surgery using bedside artificial pancreas: A propensity score‐matched analysis
Background Perioperative hyperglycemia leads to poor postoperative clinical outcomes, including compromised immune function, cardiovascular events, and mortality. The optimal perioperative blood glucose levels during cardiac surgery remain unclear. A closed-loop glycemic control system (artificial pancreas, target blood glucose range:120-150 mg/dl) prevents postoperative inflammatory response more effectively than conventional insulin therapy (<200 mg/dl). However, the clinical effects of intensive insulin therapy with strict glycemic control (80-110 mg/dl) are controversial. This study aimed to determine whether intensive insulin therapy would further suppress postoperative inflammatory reactions. Methods This study analyzed 262 patients who underwent cardiovascular surgery with cardiopulmonary bypass. The patients were divided into two groups according to their target blood glucose range: 80-110 mg/dl and 120-150 mg/dl. The primary outcome was the difference in the C-reactive protein levels between the two groups. Results Propensity score matching resulted in 95 patients in each group based on their covariates. There was no difference in the postoperative maximum C-reactive protein levels between the two groups (14.81 +/- 5.93 mg/dl vs. 14.34 +/- 5.52 mg/dl; p = 0.571) following propensity score matching. Hypoglycemia did not occur during intensive insulin therapy. Conclusions Intensive insulin therapy following cardiac surgery with cardiopulmonary bypass did not demonstrate significant advantages in the suppression of postoperative inflammatory reactions compared to that with mild glycemic control. However, intensive insulin therapy using an artificial pancreas was found to be safe, with no hypoglycemic events.