Zhao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhao Li has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Jose Lee
Professor, Dept. of Civil and Natural Resources Engineering, College of Engineering, Univ. of Canterbury, Christchurch 8020, New Zealand. ORCID
14 shared publications - Ross D. Murch
The Hong Kong University of Science and Technology
11 shared publications - Liwen Jing
Peng Cheng Laboratory, Shenzhen, China
9 shared publications Ross Murch
Hong Kong Univ. of Science and Technology
9 shared publications- Wenjie Wang
Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong
8 shared publications Liwen Jing
Department of Electronic and Computer Engineering, the Hong Kong University of Science and Technology, Hong Kong, 999077, China
6 shared publications
Latest Publications
- 1 November 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 152 (11) , 04026050
Optimization of Sensor Placement for Passive Pipeline Deterioration Monitoring Using Ambient Noise Correlation
Passive monitoring based on the correlation of ambient noise enables the estimation of pipeline wave speed and the assessment of pipe wall deterioration without active hydraulic transient generation. To scale this approach to large water distribution networks, efficient sensor placement is essential. This study develops an optimization framework that maximizes monitoring coverage while minimizing sensor count. Practical deployment constraints, including dual-peak visibility, prioritization of critical pipes, and installation at feasible access points, are incorporated. A customized genetic algorithm is applied to identify Pareto-optimal tradeoffs. Simulations on branched-looped networks show that the framework achieves full coverage under unconstrained conditions and adapts effectively to more restrictive deployment scenarios. The results demonstrate that combining passive acoustic sensing with optimization supports cost-effective and scalable deterioration monitoring for smart water networks.
- 1 November 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 152 (11) , 04026050
Optimization of Sensor Placement for Passive Pipeline Deterioration Monitoring Using Ambient Noise Correlation
Passive monitoring based on the correlation of ambient noise enables the estimation of pipeline wave speed and the assessment of pipe wall deterioration without active hydraulic transient generation. To scale this approach to large water distribution networks, efficient sensor placement is essential. This study develops an optimization framework that maximizes monitoring coverage while minimizing sensor count. Practical deployment constraints, including dual-peak visibility, prioritization of critical pipes, and installation at feasible access points, are incorporated. A customized genetic algorithm is applied to identify Pareto-optimal tradeoffs. Simulations on branched-looped networks show that the framework achieves full coverage under unconstrained conditions and adapts effectively to more restrictive deployment scenarios. The results demonstrate that combining passive acoustic sensing with optimization supports cost-effective and scalable deterioration monitoring for smart water networks.
- Open Access
- 11 September 2026
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 62 (9)
Comparative Field Evaluation of Active and Passive Transient‐Based Techniques for Pipeline Condition Assessment
Hydraulic transient‐based techniques are increasingly applied for non‐intrusive condition assessment of buried water pipelines. This study presents systematic field experiments comparing active and passive approaches within the asbestos cement water supply network at the University of Canterbury. In the active approach, controlled valve closures generated hydraulic transients analyzed via time‐domain reflectometry, while the passive approach utilized cross‐ and auto‐correlation of ambient pressure noise. Their performance was evaluated in terms of operational range, detection accuracy, and measurement duration. Results demonstrate that, for wave speed estimation, the passive approach enabled reliable time‐of‐flight estimation over a substantially greater sensor‐to‐sensor separation (projected maximum range of 980 m) than the active approach (459 m), while maintaining comparable accuracy (2%–3% error in time‐of‐flight). However, the active approach showed better robustness than the passive approach in identifying reflections from branches, valves, and joints, although the corresponding regression analysis showed only moderate performance. Measurement duration beyond 5 min showed only marginal benefit for passive wave speed estimation and negligible improvement for pipeline anomaly identification. Numerical simulations further clarified unexpected reflection features and provided insight into complex wave interactions. These findings highlight the complementary strengths of active and passive approaches and their potential for practical application in real‐world water pipeline monitoring.
- 11 September 2026
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 62 (9)
Open AccessComparative Field Evaluation of Active and Passive Transient‐Based Techniques for Pipeline Condition Assessment
Hydraulic transient‐based techniques are increasingly applied for non‐intrusive condition assessment of buried water pipelines. This study presents systematic field experiments comparing active and passive approaches within the asbestos cement water supply network at the University of Canterbury. In the active approach, controlled valve closures generated hydraulic transients analyzed via time‐domain reflectometry, while the passive approach utilized cross‐ and auto‐correlation of ambient pressure noise. Their performance was evaluated in terms of operational range, detection accuracy, and measurement duration. Results demonstrate that, for wave speed estimation, the passive approach enabled reliable time‐of‐flight estimation over a substantially greater sensor‐to‐sensor separation (projected maximum range of 980 m) than the active approach (459 m), while maintaining comparable accuracy (2%–3% error in time‐of‐flight). However, the active approach showed better robustness than the passive approach in identifying reflections from branches, valves, and joints, although the corresponding regression analysis showed only moderate performance. Measurement duration beyond 5 min showed only marginal benefit for passive wave speed estimation and negligible improvement for pipeline anomaly identification. Numerical simulations further clarified unexpected reflection features and provided insight into complex wave interactions. These findings highlight the complementary strengths of active and passive approaches and their potential for practical application in real‐world water pipeline monitoring.
- Open Access
- 1 October 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (4) , 3083-3096
Analytical modelling and simulations of acoustic interaction with avian egg
Sound reception inside avian eggs is crucial for embryonic development and hatching synchrony, yet, conventional techniques are unable to directly measure the complex transmission of sound within the egg. To address this, an analytical model is developed to predict the interaction between acoustic waves and avian eggs, providing comprehensive insights into the acoustic characteristics inside the eggshell. The model approximates the egg as a layered spherical system, consisting of an eggshell, albumen, and yolk, with the potential inclusion of an embedded sensor or embryonic structure. Governing equations for elastic and viscous media are formulated, and continuity conditions for displacement and stress are enforced at each interface. Comprehensive parametric simulations are conducted to examine the effects of geometric and mechanical properties on resonance frequencies and internal pressure amplification. The results demonstrate that the eggshell radius predominantly governs the acoustic response, whereas variations in shell thickness and material properties have secondary effects. Frequency-dependent pressure gains in the albumen and yolk reveal significant amplification near resonance. Additionally, the impact of sensor insertion is assessed to determine optimal dimensions for minimising measurement distortion.
- 1 October 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (4) , 3083-3096
Open AccessAnalytical modelling and simulations of acoustic interaction with avian egg
Sound reception inside avian eggs is crucial for embryonic development and hatching synchrony, yet, conventional techniques are unable to directly measure the complex transmission of sound within the egg. To address this, an analytical model is developed to predict the interaction between acoustic waves and avian eggs, providing comprehensive insights into the acoustic characteristics inside the eggshell. The model approximates the egg as a layered spherical system, consisting of an eggshell, albumen, and yolk, with the potential inclusion of an embedded sensor or embryonic structure. Governing equations for elastic and viscous media are formulated, and continuity conditions for displacement and stress are enforced at each interface. Comprehensive parametric simulations are conducted to examine the effects of geometric and mechanical properties on resonance frequencies and internal pressure amplification. The results demonstrate that the eggshell radius predominantly governs the acoustic response, whereas variations in shell thickness and material properties have secondary effects. Frequency-dependent pressure gains in the albumen and yolk reveal significant amplification near resonance. Additionally, the impact of sensor insertion is assessed to determine optimal dimensions for minimising measurement distortion.
- Open Access
- 21 August 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 238
Extended theoretical model for water pipeline passive assessment using ambient noise correlation
- 21 August 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 238
Open AccessExtended theoretical model for water pipeline passive assessment using ambient noise correlation
- Open Access
- 14 October 2023
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 205
Whitening method for passive water pipeline assessment using ambient noise
- 14 October 2023
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 205
Open AccessWhitening method for passive water pipeline assessment using ambient noise
- Open Access
- 29 March 2023
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 195
Compressive sensing-based correlation sidelobe suppression for passive water pipeline fault detection using ambient noise
- 29 March 2023
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 195
Open AccessCompressive sensing-based correlation sidelobe suppression for passive water pipeline fault detection using ambient noise
- 7 October 2022
- Published by Springer Nature
- p. 1077-1084
Passive Measurement of Pressure Wave Speed in Water Pipelines Using Ambient Noise
- 7 October 2022
- Published by Springer Nature
- p. 1077-1084
Passive Measurement of Pressure Wave Speed in Water Pipelines Using Ambient Noise
- 12 July 2022
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 181
Passive detection in water pipelines using ambient noise II: Field experiments
- 12 July 2022
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 181
Passive detection in water pipelines using ambient noise II: Field experiments
- 26 May 2022
- Published by SAGE Publications in Structural Health Monitoring
- Vol. 22 (2) , 814-831
Laboratory and field experiment validations on the use of hydraulic transients for estimating buried water pipeline deterioration
This paper investigates the validity of using fluid transients as a rapid screening tool to augment existing methods for assessing the condition of buried water systems. In particular, the paper provides one of the first detailed investigations on the impact of pipe wall deterioration on the characteristic of transient waves in both laboratory and field experiments. Laboratory pipeline sections were deteriorated by an accelerated corrosion process using controlled electrolytic cell reactions, and three cases were considered: where corrosion is limited to the internal wall, limited to the external wall, and where both internal and external walls are corroded. Hydraulic transient tests were carried out to measure the transient wave speed in these corroded pipe sections, and the measurements are found to be consistent with the theoretical predictions using the observed wall thickness loss, confirming that wave speed can be used as an indicator of pipe wall deterioration. Field experiments were carried out in the water supply network in the Waimakariri District, New Zealand, to validate the performance of this pipe condition diagnostic methodology. Transient tests were conducted on selected 60-year-old sections of asbestos cement (AC) pipelines and sensors were connected to standard fire hydrants to measure the wave speeds and wave reflections. Compared with the theoretical calculated wave speed of intact pipelines, a 140–300 m/s wave speed decrease was observed in most of the tested sections which is in line with the expectation for pipelines of this age. The wave speeds were used to predict the in-situ thickness of the pipe wall and these predictions were found to match with computed tomography X-ray scan results of the excavated pipe with good accuracy. The same methodology was also used to correctly detect an unrecorded plastic pipe section in the AC pipe network.
- 26 May 2022
- Published by SAGE Publications in Structural Health Monitoring
- Vol. 22 (2) , 814-831
Laboratory and field experiment validations on the use of hydraulic transients for estimating buried water pipeline deterioration
This paper investigates the validity of using fluid transients as a rapid screening tool to augment existing methods for assessing the condition of buried water systems. In particular, the paper provides one of the first detailed investigations on the impact of pipe wall deterioration on the characteristic of transient waves in both laboratory and field experiments. Laboratory pipeline sections were deteriorated by an accelerated corrosion process using controlled electrolytic cell reactions, and three cases were considered: where corrosion is limited to the internal wall, limited to the external wall, and where both internal and external walls are corroded. Hydraulic transient tests were carried out to measure the transient wave speed in these corroded pipe sections, and the measurements are found to be consistent with the theoretical predictions using the observed wall thickness loss, confirming that wave speed can be used as an indicator of pipe wall deterioration. Field experiments were carried out in the water supply network in the Waimakariri District, New Zealand, to validate the performance of this pipe condition diagnostic methodology. Transient tests were conducted on selected 60-year-old sections of asbestos cement (AC) pipelines and sensors were connected to standard fire hydrants to measure the wave speeds and wave reflections. Compared with the theoretical calculated wave speed of intact pipelines, a 140–300 m/s wave speed decrease was observed in most of the tested sections which is in line with the expectation for pipelines of this age. The wave speeds were used to predict the in-situ thickness of the pipe wall and these predictions were found to match with computed tomography X-ray scan results of the excavated pipe with good accuracy. The same methodology was also used to correctly detect an unrecorded plastic pipe section in the AC pipe network.
- 28 December 2020
- Published by World Scientific Pub Co Pte Ltd in Journal of Theoretical and Computational Acoustics
- Vol. 29 (04)
Wave Scattering from Step Discontinuities in a Water Pipeline Waveguide: Analytical Modeling and Discontinuity Material Influence
Step discontinuities, which are formed in pipeline repair and maintenance, will introduce additional wave scattering in the pipeline diagnosing work. Therefore, an analytical model is established in this paper to investigate the longitudinal wave scattering from a step discontinuity and the influence of discontinuity material on the scattering characteristics in water pipelines. In the model, axial wavenumber, displacement and stress profiles of the unblemished pipeline and discontinuity sections are calculated by a multi-layered cylindrical waveguide model. To concatenate these sections and predict the overall influences of the discontinuity, the mode matching method is applied by enforcing the flexible axial boundary conditions with an extended bi-orthogonality relation. Based on the established model, numerical calculations are carried out to investigate the reflection/transmission characteristics when discontinuity material and attenuation are considered. Both finite element method (FEM) software and laboratory experiments are also conducted for modeling verification: the maximum root mean square errors of the predicted reflection and transmission coefficients are 0.01 and 0.1 compared with FEM and experiment results, respectively. It indicates the proposed model is accurate in predicting the wave scattering from a step discontinuity in a water pipeline with the influence of discontinuity material accounted for. In addition, this pure analytical model introduces advantages in computational cost when modeling long pipelines compared with existing FEM packages.
- 28 December 2020
- Published by World Scientific Pub Co Pte Ltd in Journal of Theoretical and Computational Acoustics
- Vol. 29 (04)
Wave Scattering from Step Discontinuities in a Water Pipeline Waveguide: Analytical Modeling and Discontinuity Material Influence
Step discontinuities, which are formed in pipeline repair and maintenance, will introduce additional wave scattering in the pipeline diagnosing work. Therefore, an analytical model is established in this paper to investigate the longitudinal wave scattering from a step discontinuity and the influence of discontinuity material on the scattering characteristics in water pipelines. In the model, axial wavenumber, displacement and stress profiles of the unblemished pipeline and discontinuity sections are calculated by a multi-layered cylindrical waveguide model. To concatenate these sections and predict the overall influences of the discontinuity, the mode matching method is applied by enforcing the flexible axial boundary conditions with an extended bi-orthogonality relation. Based on the established model, numerical calculations are carried out to investigate the reflection/transmission characteristics when discontinuity material and attenuation are considered. Both finite element method (FEM) software and laboratory experiments are also conducted for modeling verification: the maximum root mean square errors of the predicted reflection and transmission coefficients are 0.01 and 0.1 compared with FEM and experiment results, respectively. It indicates the proposed model is accurate in predicting the wave scattering from a step discontinuity in a water pipeline with the influence of discontinuity material accounted for. In addition, this pure analytical model introduces advantages in computational cost when modeling long pipelines compared with existing FEM packages.