Holger Keil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Holger Keil has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Jochen Franke
BG Trauma Center at Ruprecht-Karls-Universität Heidelberg, Ludwigshafen, Germany
13 shared publications - Marc Schnetzke
Deutsches Gelenkzentrum, ATOS Klinik Heidelberg, Heidelberg, Deutschland
12 shared publications - Paul Alfred Gruetzner
BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, Ludwig-Guttmann-Str. 13, 67071 Ludwigshafen, Germany
10 shared publications - Sven Yves Vetter
BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, Ludwig-Guttmann-Str. 13, 67071 Ludwigshafen, Germany
9 shared publications - Benedict Swartman
Department for Orthopaedics and Trauma Surgery at Heidelberg University, BG Klinik Ludwigshafen, Ludwigshafen, Germany
6 shared publications - Nils Beisemann
BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, Ludwig-Guttmann-Str. 13, 67071 Ludwigshafen, Germany
6 shared publications
Latest Publications
- 1 March 2024
- Published by Georg Thieme Verlag KG in The Journal of Hip Surgery
- Vol. 08 (01) , 043-049
Intraoperative Computed Tomography in Orthopaedic Trauma Surgery
Background When using mobile 3D C-arms, impairments in image quality occur due to artefacts caused by metal implants as well as to the limited field of view. To avoid these restrictions, special computed tomography devices were designed, in order to improve image quality and to meet requirements for intraoperative usage. Objectives To analyse practicability and benefits of a mobile intraoperative CT device (Airo, Brainlab, Munich, Germany) on the basis of several parameters that were obtained during a 40-month period. Materials and Methods All procedures that were performed with usage of intraoperative CT between January 2017 and April 2020 were analysed with respect to anatomical region, count of scans, duration of scans, consequences drawn from the scans and use of navigation. Results 354 CT-scans were performed in 171 patients (mean 2.07 [1–6] scans per procedure). 47.81% of the procedures were spinal, 52.19% affected the pelvis. 83% of the procedures were navigated. In 22% of patients, improvement in implant placement or reduction was achieved; in most patients (55%), a guidewire for pedicle screws was corrected. The mean scan duration was 10.33 s (3.54–21.72). Conclusions Use of intraoperative CT was reliable and helpful. Integration in OR standards requires more effort than mobile 3D C-arms. Image quality was outstanding for intraoperative conditions and allowed proper assessment of implant placement and reduction in all cases. Due to the high financial outlay of the system and the good image quality of 3D C-arms in the extremities, we assume that this procedure can be applied in intraoperative CT in traumatological cases in spinal and pelvic surgery in high-level trauma centres. Hintergrund Bei der Anwendung mobiler 3-D-C-Bögen bestehen Einschränkungen hinsichtlich der Bildqualität, insbesondere durch Artefaktbildung und die limitierte Größe des 3-D-Volumens. Um diese Limitationen zu umgehen, wurden spezielle mobile intraoperative Computertomografen (iCT) konstruiert, die sowohl eine Verbesserung der Bildqualität sowie ein größeres „Field of View“ bieten als auch den Anforderungen eines intraoperativen Einsatzes gerecht werden sollen. Ziel der Arbeit Praktikabilität und Bildqualität eines Systems zur mobilen intraoperativen CT-Diagnostik (Airo, Brainlab, München) werden anhand verschiedener Parameter über einen Zeitraum von 40 Monaten evaluiert. Material und Methoden Alle operativen Eingriffe, die im Zeitraum zwischen Januar 2017 und April 2020 unter Anwendung der iCT erfolgten, wurden hinsichtlich der Parameter Operationsgebiet, Anzahl der Scans, Scandauer, Konsequenz aus dem Scan und Verwendung eines Navigationssystems ausgewertet. Ergebnisse 354 CT-Scans von 171 Patienten wurden ausgewertet (durchschnittlich 2,07 [1–6] Scans pro Eingriff). Hierbei erfolgten 47,81% der Eingriffe an der Wirbelsäule und 52,19% am Becken. 83% (42–100) der Eingriffe erfolgten navigiert. In 22% der Eingriffe wurde nach einem Scan eine Maßnahme durchgeführt, am häufigsten (55%) erfolgte hierbei die Korrektur eines Führungsdrahts an der Wirbelsäule. Die durchschnittliche Scandauer betrug 10,33 s (3,54–21,72). Diskussion Die Anwendung war zuverlässig und hilfreich. Der Prozess der Integration in die Abläufe ist aufwendiger als bei der Verwendung mobiler 3-D-C-Bögen. Die Bildqualität ist für intraoperative Bedingungen hervorragend und erlaubt in allen Fällen eine sichere und eindeutige Beurteilung der Situation. Aufgrund des hohen intraoperativen Aufwands sowie der hohen Investitionskosten des Systems bei ebenfalls guter Bildqualität mobiler 3-D-C-Bögen in der Extremitätenchirurgie ist die traumatologische Anwendung der iCT hauptsächlich in der operativen Therapie von Körperstammverletzungen in großen Traumazentren zu sehen. * This article is a republished version of: Keil H, Vetter SY, Grützner PA, Franke J. Intraoperative Computed Tomography in Orthopaedic Trauma Surgery. Z Orthop Unfall 2022;160(4):407–413. Article published online: 09 January 2025 © 2024. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
- 1 March 2024
- Published by Georg Thieme Verlag KG in The Journal of Hip Surgery
- Vol. 08 (01) , 043-049
Intraoperative Computed Tomography in Orthopaedic Trauma Surgery
Background When using mobile 3D C-arms, impairments in image quality occur due to artefacts caused by metal implants as well as to the limited field of view. To avoid these restrictions, special computed tomography devices were designed, in order to improve image quality and to meet requirements for intraoperative usage. Objectives To analyse practicability and benefits of a mobile intraoperative CT device (Airo, Brainlab, Munich, Germany) on the basis of several parameters that were obtained during a 40-month period. Materials and Methods All procedures that were performed with usage of intraoperative CT between January 2017 and April 2020 were analysed with respect to anatomical region, count of scans, duration of scans, consequences drawn from the scans and use of navigation. Results 354 CT-scans were performed in 171 patients (mean 2.07 [1–6] scans per procedure). 47.81% of the procedures were spinal, 52.19% affected the pelvis. 83% of the procedures were navigated. In 22% of patients, improvement in implant placement or reduction was achieved; in most patients (55%), a guidewire for pedicle screws was corrected. The mean scan duration was 10.33 s (3.54–21.72). Conclusions Use of intraoperative CT was reliable and helpful. Integration in OR standards requires more effort than mobile 3D C-arms. Image quality was outstanding for intraoperative conditions and allowed proper assessment of implant placement and reduction in all cases. Due to the high financial outlay of the system and the good image quality of 3D C-arms in the extremities, we assume that this procedure can be applied in intraoperative CT in traumatological cases in spinal and pelvic surgery in high-level trauma centres. Hintergrund Bei der Anwendung mobiler 3-D-C-Bögen bestehen Einschränkungen hinsichtlich der Bildqualität, insbesondere durch Artefaktbildung und die limitierte Größe des 3-D-Volumens. Um diese Limitationen zu umgehen, wurden spezielle mobile intraoperative Computertomografen (iCT) konstruiert, die sowohl eine Verbesserung der Bildqualität sowie ein größeres „Field of View“ bieten als auch den Anforderungen eines intraoperativen Einsatzes gerecht werden sollen. Ziel der Arbeit Praktikabilität und Bildqualität eines Systems zur mobilen intraoperativen CT-Diagnostik (Airo, Brainlab, München) werden anhand verschiedener Parameter über einen Zeitraum von 40 Monaten evaluiert. Material und Methoden Alle operativen Eingriffe, die im Zeitraum zwischen Januar 2017 und April 2020 unter Anwendung der iCT erfolgten, wurden hinsichtlich der Parameter Operationsgebiet, Anzahl der Scans, Scandauer, Konsequenz aus dem Scan und Verwendung eines Navigationssystems ausgewertet. Ergebnisse 354 CT-Scans von 171 Patienten wurden ausgewertet (durchschnittlich 2,07 [1–6] Scans pro Eingriff). Hierbei erfolgten 47,81% der Eingriffe an der Wirbelsäule und 52,19% am Becken. 83% (42–100) der Eingriffe erfolgten navigiert. In 22% der Eingriffe wurde nach einem Scan eine Maßnahme durchgeführt, am häufigsten (55%) erfolgte hierbei die Korrektur eines Führungsdrahts an der Wirbelsäule. Die durchschnittliche Scandauer betrug 10,33 s (3,54–21,72). Diskussion Die Anwendung war zuverlässig und hilfreich. Der Prozess der Integration in die Abläufe ist aufwendiger als bei der Verwendung mobiler 3-D-C-Bögen. Die Bildqualität ist für intraoperative Bedingungen hervorragend und erlaubt in allen Fällen eine sichere und eindeutige Beurteilung der Situation. Aufgrund des hohen intraoperativen Aufwands sowie der hohen Investitionskosten des Systems bei ebenfalls guter Bildqualität mobiler 3-D-C-Bögen in der Extremitätenchirurgie ist die traumatologische Anwendung der iCT hauptsächlich in der operativen Therapie von Körperstammverletzungen in großen Traumazentren zu sehen. * This article is a republished version of: Keil H, Vetter SY, Grützner PA, Franke J. Intraoperative Computed Tomography in Orthopaedic Trauma Surgery. Z Orthop Unfall 2022;160(4):407–413. Article published online: 09 January 2025 © 2024. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
- 1 November 2022
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 108 (7) , 102922
Influence of reduction quality on functional outcome and quality of life in the surgical treatment of tibial plateau fractures: A retrospective cohort study
- 1 November 2022
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 108 (7) , 102922
Influence of reduction quality on functional outcome and quality of life in the surgical treatment of tibial plateau fractures: A retrospective cohort study
- Open Access
Fluoroscopic imaging: New advances
- Open Access
- 24 March 2022
- Published by Springer Nature in Research Square
CT-Navigated Percutaneous Posterior Positioning of Pedicle Screws in The Cervical Spine
Background To evaluate reliability, practicability and precision of a novel intraoperative computed tomography(iCT)-based (Airo mobile CT scanner, Brainlab, Munich, Germany) navigated procedure to minimally-invasive positioning of cervical pedicle screws.Methods Ten consecutive patients that suffered from a cervical traumatic instability needing posterior fixation were included in this retrospective analysis. Posterior pedicle screws were positioned iCT-navigated percutaneously. After positioning of the screws, a control scan was performed to assess screw placement and correction if needed. All CT scans were randomly evaluated by two investigators with experience in skeletal CT diagnostics. In the iCT scans, positioning of the screws regarding affection of the medial pedicle cortex as well as the neuroforamina were measured. Additionally, image quality was evaluated with a subjective Likert-Scale (0-5) and a semi-objective Assessability score (0-4).Results 44 screws were placed in an average duration of surgery of 139min [83-209]. The average subjective image quality was 3.9 [2-5], the average assessability score was 3.7 [2-4]. 27 screws (61%) were positioned exactly centered in the pedicle. 4 screws perforated the medial wall by more than 2mm [2.8-2.9]. 9 screws were positioned laterally by more than 2mm [2.5-4.9]. No postoperative neurological deficits were observed.Conclusion iCT-navigated percutaneous placement of pedicle screws is a rather safe and reliable method for posterior fixation of the cervical spine that allows fixation of traumatic cervical instabilities with minimal additional trauma. Even in shallow anatomic structures, visualization of instruments and implants allows for minimally invasive surgery.
- 24 March 2022
- Published by Springer Nature in Research Square
Open AccessCT-Navigated Percutaneous Posterior Positioning of Pedicle Screws in The Cervical Spine
Background To evaluate reliability, practicability and precision of a novel intraoperative computed tomography(iCT)-based (Airo mobile CT scanner, Brainlab, Munich, Germany) navigated procedure to minimally-invasive positioning of cervical pedicle screws.Methods Ten consecutive patients that suffered from a cervical traumatic instability needing posterior fixation were included in this retrospective analysis. Posterior pedicle screws were positioned iCT-navigated percutaneously. After positioning of the screws, a control scan was performed to assess screw placement and correction if needed. All CT scans were randomly evaluated by two investigators with experience in skeletal CT diagnostics. In the iCT scans, positioning of the screws regarding affection of the medial pedicle cortex as well as the neuroforamina were measured. Additionally, image quality was evaluated with a subjective Likert-Scale (0-5) and a semi-objective Assessability score (0-4).Results 44 screws were placed in an average duration of surgery of 139min [83-209]. The average subjective image quality was 3.9 [2-5], the average assessability score was 3.7 [2-4]. 27 screws (61%) were positioned exactly centered in the pedicle. 4 screws perforated the medial wall by more than 2mm [2.8-2.9]. 9 screws were positioned laterally by more than 2mm [2.5-4.9]. No postoperative neurological deficits were observed.Conclusion iCT-navigated percutaneous placement of pedicle screws is a rather safe and reliable method for posterior fixation of the cervical spine that allows fixation of traumatic cervical instabilities with minimal additional trauma. Even in shallow anatomic structures, visualization of instruments and implants allows for minimally invasive surgery.
- 13 April 2021
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und Unfallchirurgie
- Vol. 160 (04) , 407-413
Intraoperative Computed Tomography in Orthopaedic Trauma Surgery
Background When using mobile 3D C-arms, impairments in image quality occur due to artefacts caused by metal implants as well as to the limited field of view. To avoid these restrictions, special computed tomography devices were designed, in order to improve image quality and to meet requirements for intraoperative usage. Objectives To analyse practicability and benefits of a mobile intraoperative CT device (Airo, Brainlab, Munich, Germany) on the basis of several parameters that were obtained during a 40-month period. Materials and Methods All procedures that were performed with usage of intraoperative CT between January 2017 and April 2020 were analysed with respect to anatomical region, count of scans, duration of scans, consequences drawn from the scans and use of navigation. Results 354 CT-scans were performed in 171 patients (mean 2.07 [1 – 6] scans per procedure). 47.81% of the procedures were spinal, 52.19% affected the pelvis. 83% of the procedures were navigated. In 22% of patients, improvement in implant placement or reduction was achieved; in most patients (55%), a guidewire for pedicle screws was corrected. The mean scan duration was 10.33 s (3.54 – 21.72). Conclusions Use of intraoperative CT was reliable and helpful. Integration in OR standards requires more effort than mobile 3D C-arms. Image quality was outstanding for intraoperative conditions and allowed proper assessment of implant placement and reduction in all cases. Due to the high financial outlay of the system and the good image quality of 3D C-arms in the extremities, we assume that this procedure can be applied in intraoperative CT in traumatological cases in spinal and pelvic surgery in high-level trauma centres.
- 13 April 2021
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und Unfallchirurgie
- Vol. 160 (04) , 407-413
Intraoperative Computed Tomography in Orthopaedic Trauma Surgery
Background When using mobile 3D C-arms, impairments in image quality occur due to artefacts caused by metal implants as well as to the limited field of view. To avoid these restrictions, special computed tomography devices were designed, in order to improve image quality and to meet requirements for intraoperative usage. Objectives To analyse practicability and benefits of a mobile intraoperative CT device (Airo, Brainlab, Munich, Germany) on the basis of several parameters that were obtained during a 40-month period. Materials and Methods All procedures that were performed with usage of intraoperative CT between January 2017 and April 2020 were analysed with respect to anatomical region, count of scans, duration of scans, consequences drawn from the scans and use of navigation. Results 354 CT-scans were performed in 171 patients (mean 2.07 [1 – 6] scans per procedure). 47.81% of the procedures were spinal, 52.19% affected the pelvis. 83% of the procedures were navigated. In 22% of patients, improvement in implant placement or reduction was achieved; in most patients (55%), a guidewire for pedicle screws was corrected. The mean scan duration was 10.33 s (3.54 – 21.72). Conclusions Use of intraoperative CT was reliable and helpful. Integration in OR standards requires more effort than mobile 3D C-arms. Image quality was outstanding for intraoperative conditions and allowed proper assessment of implant placement and reduction in all cases. Due to the high financial outlay of the system and the good image quality of 3D C-arms in the extremities, we assume that this procedure can be applied in intraoperative CT in traumatological cases in spinal and pelvic surgery in high-level trauma centres.
- Open Access
- 1 April 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (4) , 746-754
Vascular impulse technology versus elevation for the reduction of swelling of lower extremity joint fractures: results of a prospective randomized controlled study
Aims: Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation.Methods: A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).Results: The mean length of time until operability was 8.2 days (SD 3.0) in the intervention group and 10.2 days (SD 3.7) in the control group across all three fractures groups combined (p = 0.004). An analysis of the subgroups revealed that a significant reduction in the time to operability was achieved in two of the three: with 8.6 days (SD 2.2) versus 10.6 days (SD 3.6) in ankle fractures (p = 0.043), 9.8 days (SD 4.1) versus 12.5 days (SD 5.1) in pilon fractures (p = 0.205), and 7.0 days (SD 2.6) versus 8.4 days (SD 1.5) in calcaneal fractures (p = 0.043). A lower length of stay (p = 0.007), a reduction in pain (ppreop= 0.05; pdischarge< 0.001) and need for narcotics (ppreop= 0.064; ppostop= 0.072), an increased reduction in swelling (p < 0.001), and a lower revision rate (p = 0.044) could also be seen, and a trend towards fewer complications (p = 0.216) became apparent.Conclusion: Compared with elevation, VIT results in a significant reduction in the time to achieve operability in complex joint fractures of the lower limb. Cite this article: Bone Joint J 2021;103-B(4):746–754.
- 1 April 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (4) , 746-754
Open AccessVascular impulse technology versus elevation for the reduction of swelling of lower extremity joint fractures: results of a prospective randomized controlled study
Aims: Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation.Methods: A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).Results: The mean length of time until operability was 8.2 days (SD 3.0) in the intervention group and 10.2 days (SD 3.7) in the control group across all three fractures groups combined (p = 0.004). An analysis of the subgroups revealed that a significant reduction in the time to operability was achieved in two of the three: with 8.6 days (SD 2.2) versus 10.6 days (SD 3.6) in ankle fractures (p = 0.043), 9.8 days (SD 4.1) versus 12.5 days (SD 5.1) in pilon fractures (p = 0.205), and 7.0 days (SD 2.6) versus 8.4 days (SD 1.5) in calcaneal fractures (p = 0.043). A lower length of stay (p = 0.007), a reduction in pain (ppreop= 0.05; pdischarge< 0.001) and need for narcotics (ppreop= 0.064; ppostop= 0.072), an increased reduction in swelling (p < 0.001), and a lower revision rate (p = 0.044) could also be seen, and a trend towards fewer complications (p = 0.216) became apparent.Conclusion: Compared with elevation, VIT results in a significant reduction in the time to achieve operability in complex joint fractures of the lower limb. Cite this article: Bone Joint J 2021;103-B(4):746–754.
- Open Access
- 30 December 2020
- Published by Springer Nature in Research Square
Early Outcomes of Pelvic Trauma Patients – Complications, ICU Stay and Treatment Concepts in Two ATLS Compliant Trauma Centers: Germany and Qatar
Background: Pelvic trauma causes severe threats especially to polytraumatized patients. Not only it is in itself a possible cause for significant bleeding but it also indicates a high risk for intra-abdominal injuries. The initial treatment of patients with pelvic trauma follows the ATLS principles of priority-oriented treatment. To examine the value of this highly standardized concept and to evaluate the effect of different patient collectives on early outcome parameters, two large collectives from Germany and Qatar were analyzed regarding injury parameters and early outcomes.Methods: Patients were recruited in Hamad General Hospital, Doha, Qatar (HGH) and BG Trauma Center Ludwigshafen, Germany (BG). All patients that were treated with a pelvic fracture between 2013 and 2016 were included in this retrospective analysis. Demographic parameters were collected as well as type of injury and the frequency of complication parameters as pneumonia, acute kidney failure, ARDS, sepsis and amount of blood transfusion.Results: We recruited 1436 patients with pelvic fracture (645 from BG and 791 from HGH). The mean age was 57.4 years in the BG and 33.6 years in the HGH group (p<0.000). The mean ISS was 17.81 in the BG and 15.88 in the HGH group (p=0.009). The mean pelvic AIS was 2.65 in the BG and 2.25 in the HGH group (p<0.000). The mean frequency of complications was 9.3% in the BG and 9.9% in the HGH group (p=0.128). The mean frequency of ARDS was significantly higher in the BG group than in the HGH group (5.6% vs. 1.8%, p<0.000). The mean frequency of blood transfusion was significantly lower in the BG group than in the HGH group (28.8% vs. 39.2%, p<0.000).Conclusions: Despite significant differences in the two collectives, this analysis shows comparable results regarding early outcome parameters in patients with pelvic injuries. In total, pelvic injuries are accompanied by a relatively high complication risk and need to be evaluated and treated according to priority-based algorithms.
- 30 December 2020
- Published by Springer Nature in Research Square
Open AccessEarly Outcomes of Pelvic Trauma Patients – Complications, ICU Stay and Treatment Concepts in Two ATLS Compliant Trauma Centers: Germany and Qatar
Background: Pelvic trauma causes severe threats especially to polytraumatized patients. Not only it is in itself a possible cause for significant bleeding but it also indicates a high risk for intra-abdominal injuries. The initial treatment of patients with pelvic trauma follows the ATLS principles of priority-oriented treatment. To examine the value of this highly standardized concept and to evaluate the effect of different patient collectives on early outcome parameters, two large collectives from Germany and Qatar were analyzed regarding injury parameters and early outcomes.Methods: Patients were recruited in Hamad General Hospital, Doha, Qatar (HGH) and BG Trauma Center Ludwigshafen, Germany (BG). All patients that were treated with a pelvic fracture between 2013 and 2016 were included in this retrospective analysis. Demographic parameters were collected as well as type of injury and the frequency of complication parameters as pneumonia, acute kidney failure, ARDS, sepsis and amount of blood transfusion.Results: We recruited 1436 patients with pelvic fracture (645 from BG and 791 from HGH). The mean age was 57.4 years in the BG and 33.6 years in the HGH group (p<0.000). The mean ISS was 17.81 in the BG and 15.88 in the HGH group (p=0.009). The mean pelvic AIS was 2.65 in the BG and 2.25 in the HGH group (p<0.000). The mean frequency of complications was 9.3% in the BG and 9.9% in the HGH group (p=0.128). The mean frequency of ARDS was significantly higher in the BG group than in the HGH group (5.6% vs. 1.8%, p<0.000). The mean frequency of blood transfusion was significantly lower in the BG group than in the HGH group (28.8% vs. 39.2%, p<0.000).Conclusions: Despite significant differences in the two collectives, this analysis shows comparable results regarding early outcome parameters in patients with pelvic injuries. In total, pelvic injuries are accompanied by a relatively high complication risk and need to be evaluated and treated according to priority-based algorithms.
- 13 October 2020
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (2) , e2181
Evaluation of image quality and assessability of a new flat‐panel 3D C‐arm compared to mobile and fixed computed tomography in posterior spinal fixation
Background: This study evaluates image quality of a new flat‐panel three‐dimensional (3D) C‐arm to the current generation and to intraoperative and stationary computed tomography (CT) in spinal surgery.Methods: Three‐dimensional‐imaging of 44 posterior screws acquired with two generations of 3D C‐arms (Arcadis Orbic, AO and Cios Spin, CS, Siemens, Germany) and CT scans (mobile intraoperative CT Airo, iCT, Brainlab, Germany and stationary CT Aquilion 32, sCT, Toshiba, Japan) were performed. Evaluation regarded assessability and measurements of implant position.Results: Assessability score was 0.11 in AO, 0.56 in sCT, 0.91 in iCT and 1.46 in CS (p < 0.0005). AO and CS showed a significant difference in accuracy (p = 0.001) as well as CS and iCT (p < 0.001). Measurements of protrusion over the anterior edge did not show a significant difference (p = 0.341).Conclusions: Image quality of the new generation of flat‐panel 3D C‐arms competes with CT imaging and offers significant advantages compared to the former generation.
- 13 October 2020
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (2) , e2181
Evaluation of image quality and assessability of a new flat‐panel 3D C‐arm compared to mobile and fixed computed tomography in posterior spinal fixation
Background: This study evaluates image quality of a new flat‐panel three‐dimensional (3D) C‐arm to the current generation and to intraoperative and stationary computed tomography (CT) in spinal surgery.Methods: Three‐dimensional‐imaging of 44 posterior screws acquired with two generations of 3D C‐arms (Arcadis Orbic, AO and Cios Spin, CS, Siemens, Germany) and CT scans (mobile intraoperative CT Airo, iCT, Brainlab, Germany and stationary CT Aquilion 32, sCT, Toshiba, Japan) were performed. Evaluation regarded assessability and measurements of implant position.Results: Assessability score was 0.11 in AO, 0.56 in sCT, 0.91 in iCT and 1.46 in CS (p < 0.0005). AO and CS showed a significant difference in accuracy (p = 0.001) as well as CS and iCT (p < 0.001). Measurements of protrusion over the anterior edge did not show a significant difference (p = 0.341).Conclusions: Image quality of the new generation of flat‐panel 3D C‐arms competes with CT imaging and offers significant advantages compared to the former generation.
- Open Access
- 10 September 2020
- Published by Springer Nature in Research Square
Early Outcomes of Pelvic Trauma Patients – Complications, ICU Stay and Treatment Concepts in Two ATLS® Compliant Trauma Centers: Germany and Qatar
Background : Pelvic trauma causes severe threats especially to polytraumatized patients. Not only it is in itself a possible cause for significant bleeding but it also indicates a high risk for intra-abdominal injuries. The initial treatment of patients with pelvic trauma follows the ATLS principles of priority-oriented treatment. To examine the value of this highly standardized concept and to evaluate the effect of different patient collectives on early outcome parameters, two large collectives from Germany and Qatar were analyzed regarding injury parameters and early outcomes. Methods : Patients were recruited in Hamad General Hospital, Doha, Qatar (HGH) and BG Trauma Center Ludwigshafen, Germany (BG). All patients that were treated with a pelvic fracture between 2013 and 2016 were included in this retrospective analysis. Demographic parameters were collected as well as type of injury and the frequency of complication parameters as pneumonia, acute kidney failure, ARDS, sepsis and amount of blood transfusion. Results : We recruited 1436 patients with pelvic fracture (645 from BG and 791 from HGH). The mean age was 57.4 years in the BG and 33.6 years in the HGH group (p<0.000). The mean ISS was 17.81 in the BG and 15.88 in the HGH group (p=0.009). The mean pelvic AIS was 2.65 in the BG and 2.25 in the HGH group (p<0.000). The mean frequency of complications was 9.3% in the BG and 9.9% in the HGH group (p=0.128). The mean frequency of ARDS was significantly higher in the BG group than in the HGH group (5.6% vs. 1.8%, p<0.000). The mean frequency of blood transfusion was significantly lower in the BG group than in the HGH group (28.8% vs. 39.2%, p<0.000). Discussion and Conclusion : Despite significant differences in the two collectives, this analysis shows comparable results regarding early outcome parameters in patients with pelvic injuries. In total, pelvic injuries are accompanied by a relatively high complication risk and need to be evaluated and treated according to priority-based algorithms.
- 10 September 2020
- Published by Springer Nature in Research Square
Open AccessEarly Outcomes of Pelvic Trauma Patients – Complications, ICU Stay and Treatment Concepts in Two ATLS® Compliant Trauma Centers: Germany and Qatar
Background : Pelvic trauma causes severe threats especially to polytraumatized patients. Not only it is in itself a possible cause for significant bleeding but it also indicates a high risk for intra-abdominal injuries. The initial treatment of patients with pelvic trauma follows the ATLS principles of priority-oriented treatment. To examine the value of this highly standardized concept and to evaluate the effect of different patient collectives on early outcome parameters, two large collectives from Germany and Qatar were analyzed regarding injury parameters and early outcomes. Methods : Patients were recruited in Hamad General Hospital, Doha, Qatar (HGH) and BG Trauma Center Ludwigshafen, Germany (BG). All patients that were treated with a pelvic fracture between 2013 and 2016 were included in this retrospective analysis. Demographic parameters were collected as well as type of injury and the frequency of complication parameters as pneumonia, acute kidney failure, ARDS, sepsis and amount of blood transfusion. Results : We recruited 1436 patients with pelvic fracture (645 from BG and 791 from HGH). The mean age was 57.4 years in the BG and 33.6 years in the HGH group (p<0.000). The mean ISS was 17.81 in the BG and 15.88 in the HGH group (p=0.009). The mean pelvic AIS was 2.65 in the BG and 2.25 in the HGH group (p<0.000). The mean frequency of complications was 9.3% in the BG and 9.9% in the HGH group (p=0.128). The mean frequency of ARDS was significantly higher in the BG group than in the HGH group (5.6% vs. 1.8%, p<0.000). The mean frequency of blood transfusion was significantly lower in the BG group than in the HGH group (28.8% vs. 39.2%, p<0.000). Discussion and Conclusion : Despite significant differences in the two collectives, this analysis shows comparable results regarding early outcome parameters in patients with pelvic injuries. In total, pelvic injuries are accompanied by a relatively high complication risk and need to be evaluated and treated according to priority-based algorithms.