Yang Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yang Lu has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Thomas G. Bifano
Department of Mechanical Engineering, Boston University, Boston, Massachusetts 02215, USA
10 shared publications - Selim Unlu
Department of Electrical and Computer Engineering, Boston University, Boston, USA
9 shared publications Bennett B. Goldberg
Boston University, Boston, MA, USA
4 shared publicationsE. Ramsay
Boston University, Boston, MA, USA
4 shared publicationsEuan Ramsay
Boston University, Boston, MA, USA
4 shared publicationsJason B. Stewart
MIT Lincoln Lab. (United States)
4 shared publications
Latest Publications
- Open Access
- 19 May 2020
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 9
CytoCensus, mapping cell identity and division in tissues and organs using machine learning
A major challenge in cell and developmental biology is the automated identification and quantitation of cells in complex multilayered tissues. We developed CytoCensus: an easily deployed implementation of supervised machine learning that extends convenient 2D ‘point-and-click’ user training to 3D detection of cells in challenging datasets with ill-defined cell boundaries. In tests on such datasets, CytoCensus outperforms other freely available image analysis software in accuracy and speed of cell detection. We used CytoCensus to count stem cells and their progeny, and to quantify individual cell divisions from time-lapse movies of explanted Drosophila larval brains, comparing wild-type and mutant phenotypes. We further illustrate the general utility and future potential of CytoCensus by analysing the 3D organisation of multiple cell classes in Zebrafish retinal organoids and cell distributions in mouse embryos. CytoCensus opens the possibility of straightforward and robust automated analysis of developmental phenotypes in complex tissues.
- 19 May 2020
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 9
Open AccessCytoCensus, mapping cell identity and division in tissues and organs using machine learning
A major challenge in cell and developmental biology is the automated identification and quantitation of cells in complex multilayered tissues. We developed CytoCensus: an easily deployed implementation of supervised machine learning that extends convenient 2D ‘point-and-click’ user training to 3D detection of cells in challenging datasets with ill-defined cell boundaries. In tests on such datasets, CytoCensus outperforms other freely available image analysis software in accuracy and speed of cell detection. We used CytoCensus to count stem cells and their progeny, and to quantify individual cell divisions from time-lapse movies of explanted Drosophila larval brains, comparing wild-type and mutant phenotypes. We further illustrate the general utility and future potential of CytoCensus by analysing the 3D organisation of multiple cell classes in Zebrafish retinal organoids and cell distributions in mouse embryos. CytoCensus opens the possibility of straightforward and robust automated analysis of developmental phenotypes in complex tissues.
- 12 December 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (1) , 167-180
Visualizing the vasculature of the entire human eye posterior hemisphere without a contrast agent
The platform described here combines the non-invasive measurement of the retina/choroid structure and ocular blood flow based on optical coherence tomography (OCT) and wide-field semi-quantitative global flow visualization using line-scanning Doppler flowmetry (LSDF). The combination of these two imaging modalities within the same platform enables comprehensive assessment of blood flow in the retina and choroid in animals and human subjects for diagnostic purposes. Ultra-widefield vasculature visualization is demonstrated here for the first time without injecting additional contrast agents and based only on the motion of particles within the vasculature.
- 12 December 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (1) , 167-180
Visualizing the vasculature of the entire human eye posterior hemisphere without a contrast agent
The platform described here combines the non-invasive measurement of the retina/choroid structure and ocular blood flow based on optical coherence tomography (OCT) and wide-field semi-quantitative global flow visualization using line-scanning Doppler flowmetry (LSDF). The combination of these two imaging modalities within the same platform enables comprehensive assessment of blood flow in the retina and choroid in animals and human subjects for diagnostic purposes. Ultra-widefield vasculature visualization is demonstrated here for the first time without injecting additional contrast agents and based only on the motion of particles within the vasculature.
- Open Access
- 7 September 2018
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 9, 989
Estimation of Diabetic Retinal Microaneurysm Perfusion Parameters Based on Computational Fluid Dynamics Modeling of Adaptive Optics Scanning Laser Ophthalmoscopy
Diabetic retinopathy (DR) is a leading cause of vision loss worldwide. Microaneurysms (MAs), which are abnormal outpouchings of the retinal vessels, are early and hallmark lesions of DR. The presence and severity of MAs are utilized to determine overall DR severity. In addition, MAs can directly contribute to retinal neural pathology by leaking fluid into the surrounding retina, causing abnormal central retinal thickening and thereby frequently leading to vision loss. Vascular perfusion parameters such as shear rate (SR) or wall shear stress (WSS) have been linked to blood clotting and endothelial cell dysfunction, respectively in non-retinal vasculature. However, despite the importance of MAs as a key aspect of diabetic retinal pathology, much remains unknown as to how structural characteristics of individual MAs are associated with these perfusion attributes. MA structural information obtained on high resolution adaptive optics scanning laser ophthalmoscopy (AOSLO) was utilized to estimate perfusion parameters through Computational Fluid Dynamics (CFD) analysis of the AOSLO images. The HemeLB solver was used to simulate steady-state and time-dependent flow using both commodity hospital-based and high-performance-computing resources, depending on the degree of detail required in the simulations. Our results indicate that WSS is lowest in MA regions furthest away from the feeding vessels. Furthermore, areas of low SR are associated with clot location in saccular MAs. These findings suggest that morphology and CFD estimation of perfusion parameters may be useful tools for determining the likelihood of clot presence in individual diabetic MAs.
- 7 September 2018
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 9, 989
Open AccessEstimation of Diabetic Retinal Microaneurysm Perfusion Parameters Based on Computational Fluid Dynamics Modeling of Adaptive Optics Scanning Laser Ophthalmoscopy
Diabetic retinopathy (DR) is a leading cause of vision loss worldwide. Microaneurysms (MAs), which are abnormal outpouchings of the retinal vessels, are early and hallmark lesions of DR. The presence and severity of MAs are utilized to determine overall DR severity. In addition, MAs can directly contribute to retinal neural pathology by leaking fluid into the surrounding retina, causing abnormal central retinal thickening and thereby frequently leading to vision loss. Vascular perfusion parameters such as shear rate (SR) or wall shear stress (WSS) have been linked to blood clotting and endothelial cell dysfunction, respectively in non-retinal vasculature. However, despite the importance of MAs as a key aspect of diabetic retinal pathology, much remains unknown as to how structural characteristics of individual MAs are associated with these perfusion attributes. MA structural information obtained on high resolution adaptive optics scanning laser ophthalmoscopy (AOSLO) was utilized to estimate perfusion parameters through Computational Fluid Dynamics (CFD) analysis of the AOSLO images. The HemeLB solver was used to simulate steady-state and time-dependent flow using both commodity hospital-based and high-performance-computing resources, depending on the degree of detail required in the simulations. Our results indicate that WSS is lowest in MA regions furthest away from the feeding vessels. Furthermore, areas of low SR are associated with clot location in saccular MAs. These findings suggest that morphology and CFD estimation of perfusion parameters may be useful tools for determining the likelihood of clot presence in individual diabetic MAs.
- 1 January 2018
- Published by Optica Publishing Group
- p. JW3P.3
Simultaneous Multi-Channel AOSLO Imaging for Visualizing Inner Retina Structures
A new detection scheme was demonstrated for multiple channels simultaneous imaging that provides isotropic images of inner retina structures free of directionality artifacts. The channels can be combined to reveal additional structural and functional details.
- 1 January 2018
- Published by Optica Publishing Group
- p. JW3P.3
Simultaneous Multi-Channel AOSLO Imaging for Visualizing Inner Retina Structures
A new detection scheme was demonstrated for multiple channels simultaneous imaging that provides isotropic images of inner retina structures free of directionality artifacts. The channels can be combined to reveal additional structural and functional details.
- Open Access
Single molecule fluorescence in situ hybridisation for quantitating post-transcriptional regulation in Drosophila brains
RNA in situ hybridization can be a powerful method to investigate post-transcriptional regulation, but analysis of intracellular mRNA distributions in thick, complex tissues like the brain poses significant challenges. Here, we describe the application of single-molecule fluorescent in situ hybridization (smFISH) to quantitate primary transcription and post-transcriptional regulation in whole-mount Drosophila larval and adult brains. Combining immunofluorescence and smFISH probes for different regions of a single gene, i.e., exons, 3’UTR, and introns, we show examples of a gene that is regulated post-transcriptionally and one that is regulated at the level of transcription. We also show that the method can be used to co-visualise a variety of different transcripts and proteins in neuronal stems cells as well as deep brain structures such as mushroom body neuropils. Finally, we introduce the use of smFISH as asensitivealternative to conventional antibody labelling to mark specific neural stem cell populations in the brain.
Open AccessSingle molecule fluorescence in situ hybridisation for quantitating post-transcriptional regulation in Drosophila brains
RNA in situ hybridization can be a powerful method to investigate post-transcriptional regulation, but analysis of intracellular mRNA distributions in thick, complex tissues like the brain poses significant challenges. Here, we describe the application of single-molecule fluorescent in situ hybridization (smFISH) to quantitate primary transcription and post-transcriptional regulation in whole-mount Drosophila larval and adult brains. Combining immunofluorescence and smFISH probes for different regions of a single gene, i.e., exons, 3’UTR, and introns, we show examples of a gene that is regulated post-transcriptionally and one that is regulated at the level of transcription. We also show that the method can be used to co-visualise a variety of different transcripts and proteins in neuronal stems cells as well as deep brain structures such as mushroom body neuropils. Finally, we introduce the use of smFISH as asensitivealternative to conventional antibody labelling to mark specific neural stem cell populations in the brain.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2015 (1094687X) , 8070-8073
Characterization of parafoveal hemodynamics associated with diabetic retinopathy with adaptive optics scanning laser ophthalmoscopy and computational fluid dynamics
Diabetic retinopathy (DR) remains the leading cause of visual loss in working age adults in the United States and other developed countries worldwide. Previous studies have reported hemodynamic changes in the diabetic eye that precede clinically evident pathological alterations of the retinal microvasculature. There exists a pressing need for new methods to allow greater understanding of these early hemodynamic changes that occur in DR. In the current study, we propose a noninvasive method for the assessment of hemodynamics around the fovea (a region of the eye of paramount importance for vision). The proposed methodology combines adaptive optics scanning laser ophthalmoscopy and computational fluid dynamics modeling and simulation. Our preliminary results indicate that the technique presented here is feasible for the assessment of hemodynamics in the foveal region of the eye and, moreover, that it is capable of detecting differences in hemodynamics between eyes that may be associated with DR status. We believe that the proposed methodology has the potential to become a useful tool for the evaluation of human retinal hemodynamics in a clinical context.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2015 (1094687X) , 8070-8073
Characterization of parafoveal hemodynamics associated with diabetic retinopathy with adaptive optics scanning laser ophthalmoscopy and computational fluid dynamics
Diabetic retinopathy (DR) remains the leading cause of visual loss in working age adults in the United States and other developed countries worldwide. Previous studies have reported hemodynamic changes in the diabetic eye that precede clinically evident pathological alterations of the retinal microvasculature. There exists a pressing need for new methods to allow greater understanding of these early hemodynamic changes that occur in DR. In the current study, we propose a noninvasive method for the assessment of hemodynamics around the fovea (a region of the eye of paramount importance for vision). The proposed methodology combines adaptive optics scanning laser ophthalmoscopy and computational fluid dynamics modeling and simulation. Our preliminary results indicate that the technique presented here is feasible for the assessment of hemodynamics in the foveal region of the eye and, moreover, that it is capable of detecting differences in hemodynamics between eyes that may be associated with DR status. We believe that the proposed methodology has the potential to become a useful tool for the evaluation of human retinal hemodynamics in a clinical context.
- 8 November 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (23) , 28189-28197
Aberration compensation in aplanatic solid immersion lens microscopy
The imaging quality of an aplanatic SIL microscope is shown to be significantly degraded by aberrations, especially when the samples have thicknesses that are more than a few micrometers thicker or thinner than the design thickness. Aberration due to the sample thickness error is modeled and compared with measurements obtained in a high numerical aperture (NA ~3.5) microscope. A technique to recover near-ideal imaging quality by compensating aberrations using a MEMS deformable mirror is described and demonstrated.
- 8 November 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (23) , 28189-28197
Aberration compensation in aplanatic solid immersion lens microscopy
The imaging quality of an aplanatic SIL microscope is shown to be significantly degraded by aberrations, especially when the samples have thicknesses that are more than a few micrometers thicker or thinner than the design thickness. Aberration due to the sample thickness error is modeled and compared with measurements obtained in a high numerical aperture (NA ~3.5) microscope. A technique to recover near-ideal imaging quality by compensating aberrations using a MEMS deformable mirror is described and demonstrated.
- 1 November 2013
- Published by ASM International
- Vol. 80224, 417-419
Adaptive Optics Compensation of Aberrations Introduced by Sample Thickness Error in aSIL Confocal Scanning Microscopy
We report on aberration compensation in an aplanatic solid immersion lens microscope used for high-resolution backside inspection of silicon integrated circuits. The imaging quality of aplanatic SIL microscope is shown to be significantly degraded by aberrations, especially when the silicon integrated circuit samples have thicknesses that are more than a few micrometers thicker or thinner than ideal. We describe and demonstrate a technique to recover near-ideal imaging quality by compensating those aberrations using a MEMS deformable mirror. The mirror, located in an optical plane conjugate to the microscope objective, is shaped in a way that counteracts spherical aberration errors associated with non-ideal sample thickness.
- 1 November 2013
- Published by ASM International
- Vol. 80224, 417-419
Adaptive Optics Compensation of Aberrations Introduced by Sample Thickness Error in aSIL Confocal Scanning Microscopy
We report on aberration compensation in an aplanatic solid immersion lens microscope used for high-resolution backside inspection of silicon integrated circuits. The imaging quality of aplanatic SIL microscope is shown to be significantly degraded by aberrations, especially when the silicon integrated circuit samples have thicknesses that are more than a few micrometers thicker or thinner than ideal. We describe and demonstrate a technique to recover near-ideal imaging quality by compensating those aberrations using a MEMS deformable mirror. The mirror, located in an optical plane conjugate to the microscope objective, is shaped in a way that counteracts spherical aberration errors associated with non-ideal sample thickness.
- 1 November 2012
- Published by ASM International
- Vol. 39791, 6-10
Closer to the Theoretical Limit: Spherical Corrections to Aplanatic Solid Immersion Imaging with Adaptive Optics
Aplanatic solid immersion lens (SIL) microscopy is required to achieve the highest possible resolution for next generation silicon IC backside inspection and failure analysis. However, aplanatic SILs are susceptible to spherical aberration introduced by substrate thickness mismatch. We have developed a wavefront precompensation technique using a MEMS deformable mirror and demonstrated an increase in substrate thickness tolerance in aplanatic SIL imaging. Good agreement between theory and experiment is achieved and spot intensity increases by at least a factor of two to three are demonstrated for thicknesses deviating several percent from ideal. This technique is also capable of fixing aberrations due to SIL fabrication, off-axis imaging and refractive index mismatch.
- 1 November 2012
- Published by ASM International
- Vol. 39791, 6-10
Closer to the Theoretical Limit: Spherical Corrections to Aplanatic Solid Immersion Imaging with Adaptive Optics
Aplanatic solid immersion lens (SIL) microscopy is required to achieve the highest possible resolution for next generation silicon IC backside inspection and failure analysis. However, aplanatic SILs are susceptible to spherical aberration introduced by substrate thickness mismatch. We have developed a wavefront precompensation technique using a MEMS deformable mirror and demonstrated an increase in substrate thickness tolerance in aplanatic SIL imaging. Good agreement between theory and experiment is achieved and spot intensity increases by at least a factor of two to three are demonstrated for thicknesses deviating several percent from ideal. This technique is also capable of fixing aberrations due to SIL fabrication, off-axis imaging and refractive index mismatch.
- 1 November 2012
- Published by ASM International
- p. 172-175
Dual-Phase Interferometric Confocal Imaging for Electrical Signal Modulation Mapping in ICs
This paper demonstrates a differential dual-phase interferometric imaging method in which the reflected probe beam modulated weakly by the charge carriers is mixed separately with two reference beams with a known phase shift in between. Performing a balanced detection scheme on these two channels, the common-mode-noise associated with strong DC background and its noise can be significantly reduced. The performance of the interferometric technique is systematically compared with the conventional mapping method through investigating inverter chains on two test chips of 180nm bulk silicon technology and 32nm SOI technology. The future work will focus on adapting the method for GHz frequency regime and time-domain implementation of the method. The method will find applications in failure analysis and testing of advanced technology IC chips for which the high sensitivity in modulation mapping is required.
- 1 November 2012
- Published by ASM International
- p. 172-175
Dual-Phase Interferometric Confocal Imaging for Electrical Signal Modulation Mapping in ICs
This paper demonstrates a differential dual-phase interferometric imaging method in which the reflected probe beam modulated weakly by the charge carriers is mixed separately with two reference beams with a known phase shift in between. Performing a balanced detection scheme on these two channels, the common-mode-noise associated with strong DC background and its noise can be significantly reduced. The performance of the interferometric technique is systematically compared with the conventional mapping method through investigating inverter chains on two test chips of 180nm bulk silicon technology and 32nm SOI technology. The future work will focus on adapting the method for GHz frequency regime and time-domain implementation of the method. The method will find applications in failure analysis and testing of advanced technology IC chips for which the high sensitivity in modulation mapping is required.