Mark E. Siemens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mark E. Siemens has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Mark T. Lusk
Colorado School of Mines
17 shared publications - Andrew A. Voitiv
Department of Physics and Astronomy, University of Denver 1 , Denver, Colorado 80208, USA
14 shared publications - Juliet T. Gopinath
University of Colorado
11 shared publications Andrew A. Voitiv
Department of Physics and Astronomy University of Denver Denver CO USA
10 shared publicationsChuanzhou Zhu
Department of Physics Colorado School of Mines 1500 Illinois Street 80401 Golden CO USA
7 shared publications- Geoffrey Diederich
Department of Physics and Astronomy, University of Denver, 2112 East Wesley Avenue, Denver, Colorado 80208, USA
5 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (3)
Recent advances in stimulated emission depletion (STED) super-resolution microscopy for in vivo imaging
Recent advances in stimulated emission depletion (STED) microscopy have resulted in breakthroughs in biological imaging. Such advances include three-dimensional (3D) imaging, aberration correction to enhance resolution at depth in tissue, reduction in photobleaching, and label-free STED-inspired alternatives, enabling in vivo applications. In this perspective, we first summarize the basic principles of stimulated emission depletion microscopy and its major challenges. Next, we discuss techniques to reduce photobleaching, 3D imaging with STED, deep tissue imaging with STED, fiber-coupled STED, live animal imaging, and label-free imaging with super-resolution. Finally, we summarize and provide perspectives for future research.
- 1 March 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (3)
Open AccessRecent advances in stimulated emission depletion (STED) super-resolution microscopy for in vivo imaging
Recent advances in stimulated emission depletion (STED) microscopy have resulted in breakthroughs in biological imaging. Such advances include three-dimensional (3D) imaging, aberration correction to enhance resolution at depth in tissue, reduction in photobleaching, and label-free STED-inspired alternatives, enabling in vivo applications. In this perspective, we first summarize the basic principles of stimulated emission depletion microscopy and its major challenges. Next, we discuss techniques to reduce photobleaching, 3D imaging with STED, deep tissue imaging with STED, fiber-coupled STED, live animal imaging, and label-free imaging with super-resolution. Finally, we summarize and provide perspectives for future research.
- Open Access
- 1 May 2025
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (5) , 055704
Two-step phase-shifting interferometry for phase-resolved imaging from a spatial light modulator
We demonstrate two-step phase-shifting interferometry (holography) of complex laser modes generated by a spatial light modulator (SLM), in which the amplitude and phase of the signal are determined directly from measurements of phase-shifted interferograms. The reference and signal beams are generated and phase-controlled with a single composite hologram on the SLM and propagated collinearly. This requires no additional optics and leads to measurements that are more accurate and less prone to noise, which we demonstrate with collinearly-referenced measurements of various Laguerre–Gaussian modes and structured images.
- 1 May 2025
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (5) , 055704
Open AccessTwo-step phase-shifting interferometry for phase-resolved imaging from a spatial light modulator
We demonstrate two-step phase-shifting interferometry (holography) of complex laser modes generated by a spatial light modulator (SLM), in which the amplitude and phase of the signal are determined directly from measurements of phase-shifted interferograms. The reference and signal beams are generated and phase-controlled with a single composite hologram on the SLM and propagated collinearly. This requires no additional optics and leads to measurements that are more accurate and less prone to noise, which we demonstrate with collinearly-referenced measurements of various Laguerre–Gaussian modes and structured images.
- Open Access
Two-step phase-shifting interferometry for phase-resolved imaging from a spatial light modulator
We demonstrate two-step phase-shifting interferometry (holography) of complex laser modes generated by a spatial light modulator (SLM), in which the amplitude and phase of the signal are determined directly from measurements of phase-shifted interferograms. The reference and signal beams are generated and phase-controlled with a single composite hologram on the SLM and propagated collinearly. This requires no additional optics and leads to measurements that are more accurate and less prone to noise, which we demonstrate with collinearly-referenced measurements of various Laguerre-Gaussian modes and structured images.
Open AccessTwo-step phase-shifting interferometry for phase-resolved imaging from a spatial light modulator
We demonstrate two-step phase-shifting interferometry (holography) of complex laser modes generated by a spatial light modulator (SLM), in which the amplitude and phase of the signal are determined directly from measurements of phase-shifted interferograms. The reference and signal beams are generated and phase-controlled with a single composite hologram on the SLM and propagated collinearly. This requires no additional optics and leads to measurements that are more accurate and less prone to noise, which we demonstrate with collinearly-referenced measurements of various Laguerre-Gaussian modes and structured images.
- 1 August 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (17) , 29558-29565
Using orbital angular momentum for temperature and force sensing in an optical fiber
We demonstrate an optical fiber sensor that uses the orbital angular momentum of light in a polarization maintaining fiber to act as a temperature and force sensor. The polarization of the input light is shown to greatly affect the sensitivity of the sensor. In addition, we show how our sensor can be used to resolve the direction and magnitude of a force applied to a fiber.
- 1 August 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (17) , 29558-29565
Using orbital angular momentum for temperature and force sensing in an optical fiber
We demonstrate an optical fiber sensor that uses the orbital angular momentum of light in a polarization maintaining fiber to act as a temperature and force sensor. The polarization of the input light is shown to greatly affect the sensitivity of the sensor. In addition, we show how our sensor can be used to resolve the direction and magnitude of a force applied to a fiber.
- 30 July 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (15) , 4417-4420
Fast finite difference solver for optical microscopy in deep biological tissue
Optical scattering poses a significant challenge to high-resolution microscopy within deep tissue. To accurately predict the performance of various microscopy techniques in thick samples, we present a computational model that efficiently solves Maxwell’s equation in highly scattering media. This toolkit simulates the deterioration of the laser beam point spread function (PSF) without making a paraxial approximation, enabling accurate modeling of high-numerical-aperture (NA) objective lenses commonly employed in experiments. Moreover, this framework is applicable to a broad range of scanning microscopy techniques including confocal microscopy, stimulated emission depletion (STED) microscopy, and ground-state depletion microscopy. Notably, the proposed method requires only readily obtainable macroscopic tissue parameters. As a practical demonstration, we investigate the performance of Laguerre–Gaussian (LG) versus Hermite–Gaussian (HG) depletion beams in STED microscopy.
- 30 July 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (15) , 4417-4420
Fast finite difference solver for optical microscopy in deep biological tissue
Optical scattering poses a significant challenge to high-resolution microscopy within deep tissue. To accurately predict the performance of various microscopy techniques in thick samples, we present a computational model that efficiently solves Maxwell’s equation in highly scattering media. This toolkit simulates the deterioration of the laser beam point spread function (PSF) without making a paraxial approximation, enabling accurate modeling of high-numerical-aperture (NA) objective lenses commonly employed in experiments. Moreover, this framework is applicable to a broad range of scanning microscopy techniques including confocal microscopy, stimulated emission depletion (STED) microscopy, and ground-state depletion microscopy. Notably, the proposed method requires only readily obtainable macroscopic tissue parameters. As a practical demonstration, we investigate the performance of Laguerre–Gaussian (LG) versus Hermite–Gaussian (HG) depletion beams in STED microscopy.
- Open Access
- 12 June 2024
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 11 (03) , 034311-14
OpenSTED: open-source dynamic intensity minimum system for stimulated emission depletion microscopy
SignificanceStimulated emission depletion (STED) is a powerful super-resolution microscopy technique that can be used for imaging live cells. However, the high STED laser powers can cause significant photobleaching and sample damage in sensitive biological samples. The dynamic intensity minimum (DyMIN) technique turns on the STED laser only in regions of the sample where there is fluorescence signal, thus saving significant sample photobleaching. The reduction in photobleaching allows higher resolution images to be obtained and longer time-lapse imaging of live samples. A stand-alone module to perform DyMIN is not available commercially.AimIn this work, we developed an open-source design to implement three-step DyMIN on a STED microscope and demonstrated reduced photobleaching for timelapse imaging of beads, cells, and tissue.ApproachThe DyMIN system uses a fast multiplexer circuit and inexpensive field-programmable gate array controlled by Labview software that operates as a stand-alone module for a STED microscope. All software and circuit diagrams are freely available.ResultsWe compared time-lapse images of bead samples using our custom DyMIN system to conventional STED and recorded a ∼46% higher signal when using DyMIN after a 50-image sequence. We further demonstrated the DyMIN system for time-lapse STED imaging of live cells and brain tissue slices.ConclusionsOur open-source DyMIN system is an inexpensive add-on to a conventional STED microscope that can reduce photobleaching. The system can significantly improve signal to noise for dynamic time-lapse STED imaging of live samples.
- 12 June 2024
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 11 (03) , 034311-14
Open AccessOpenSTED: open-source dynamic intensity minimum system for stimulated emission depletion microscopy
SignificanceStimulated emission depletion (STED) is a powerful super-resolution microscopy technique that can be used for imaging live cells. However, the high STED laser powers can cause significant photobleaching and sample damage in sensitive biological samples. The dynamic intensity minimum (DyMIN) technique turns on the STED laser only in regions of the sample where there is fluorescence signal, thus saving significant sample photobleaching. The reduction in photobleaching allows higher resolution images to be obtained and longer time-lapse imaging of live samples. A stand-alone module to perform DyMIN is not available commercially.AimIn this work, we developed an open-source design to implement three-step DyMIN on a STED microscope and demonstrated reduced photobleaching for timelapse imaging of beads, cells, and tissue.ApproachThe DyMIN system uses a fast multiplexer circuit and inexpensive field-programmable gate array controlled by Labview software that operates as a stand-alone module for a STED microscope. All software and circuit diagrams are freely available.ResultsWe compared time-lapse images of bead samples using our custom DyMIN system to conventional STED and recorded a ∼46% higher signal when using DyMIN after a 50-image sequence. We further demonstrated the DyMIN system for time-lapse STED imaging of live cells and brain tissue slices.ConclusionsOur open-source DyMIN system is an inexpensive add-on to a conventional STED microscope that can reduce photobleaching. The system can significantly improve signal to noise for dynamic time-lapse STED imaging of live samples.
- Open Access
- 1 June 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (6)
Phase-resolved measurement of entangled states via common-path interferometry
We propose and experimentally demonstrate a method to directly measure the phase of biphoton states using an entangled mode as a collinear reference. The technique is demonstrated with entangled photonic spatial modes in the Laguerre–Gaussian basis, and it is applicable to any pure quantum system containing an exploitable reference state in its entanglement spectrum. As one particularly useful application, we use the new methodology to directly measure the geometric phase accumulation of entangled photons.
- 1 June 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (6)
Open AccessPhase-resolved measurement of entangled states via common-path interferometry
We propose and experimentally demonstrate a method to directly measure the phase of biphoton states using an entangled mode as a collinear reference. The technique is demonstrated with entangled photonic spatial modes in the Laguerre–Gaussian basis, and it is applicable to any pure quantum system containing an exploitable reference state in its entanglement spectrum. As one particularly useful application, we use the new methodology to directly measure the geometric phase accumulation of entangled photons.
- Open Access
Measurement of nonequilibrium vortex propagation dynamics in a nonlinear medium
We observe and measure the nonequilibrium dynamics of optical vortices as a function of propagation distance through a nonlinear medium. The precession of a tilted-core vortex is quantified as is vortex-core sharpening, where the infinite width of a linear core subsequently shrinks and approaches the healing length of this nonlinear optical fluid. Experiments are performed with a variable-length nonlinear medium: a nonlinear fluid in a tank with an output window on a translating tube. This provides control over the distance the light propagates in the fluid and allows for the measurement of the dynamics throughout the entire propagation range. Results are compared to the predictions of a computational simulator to find the equivalent dimensionless nonlinear coefficient.
Open AccessMeasurement of nonequilibrium vortex propagation dynamics in a nonlinear medium
We observe and measure the nonequilibrium dynamics of optical vortices as a function of propagation distance through a nonlinear medium. The precession of a tilted-core vortex is quantified as is vortex-core sharpening, where the infinite width of a linear core subsequently shrinks and approaches the healing length of this nonlinear optical fluid. Experiments are performed with a variable-length nonlinear medium: a nonlinear fluid in a tank with an output window on a translating tube. This provides control over the distance the light propagates in the fluid and allows for the measurement of the dynamics throughout the entire propagation range. Results are compared to the predictions of a computational simulator to find the equivalent dimensionless nonlinear coefficient.
- Open Access
- 1 March 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (3)
Measurement of nonequilibrium vortex propagation dynamics in a nonlinear medium
We observe and measure the nonequilibrium dynamics of optical vortices as a function of propagation distance through a nonlinear medium. The precession of a tilted-core vortex is quantified as is vortex core sharpening, where the infinite width of a linear core subsequently shrinks and approaches the healing length of this nonlinear optical fluid. Experiments are performed with a variable-length nonlinear medium: a nonlinear fluid in a tank with an output window on a translating tube. This provides control over the distance the light propagates in the fluid and allows for the measurement of the dynamics throughout the propagation range. Results are compared with the predictions of a computational simulator to find the equivalent dimensionless nonlinear coefficient.
- 1 March 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (3)
Open AccessMeasurement of nonequilibrium vortex propagation dynamics in a nonlinear medium
We observe and measure the nonequilibrium dynamics of optical vortices as a function of propagation distance through a nonlinear medium. The precession of a tilted-core vortex is quantified as is vortex core sharpening, where the infinite width of a linear core subsequently shrinks and approaches the healing length of this nonlinear optical fluid. Experiments are performed with a variable-length nonlinear medium: a nonlinear fluid in a tank with an output window on a translating tube. This provides control over the distance the light propagates in the fluid and allows for the measurement of the dynamics throughout the propagation range. Results are compared with the predictions of a computational simulator to find the equivalent dimensionless nonlinear coefficient.
- 20 February 2024
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 41 (3) , 653-658
Obtaining the impulse response from nonlinear spectroscopy measurements by laser normalization
In nonlinear spectroscopies, the detected spectrum is determined by the response of the system to the particular excitation pulses, which can vary as excitation energy and pulse duration are tuned. Here, we analytically show that, under reasonable assumptions, the nested integrals that describe the light-matter interaction of the system can be simplified by application of the Fourier convolution and shift theorems, resulting in an expression for the nonlinear spectrum that is a product of the impulsive system response and the interaction laser spectra. The impulsive response can then be obtained by linearly dividing the laser spectrum from the detected signal. We demonstrate our normalization scheme by recovering the impulsive response from two different material systems, highlighting removal of distinct spectral artifacts.
- 20 February 2024
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 41 (3) , 653-658
Obtaining the impulse response from nonlinear spectroscopy measurements by laser normalization
In nonlinear spectroscopies, the detected spectrum is determined by the response of the system to the particular excitation pulses, which can vary as excitation energy and pulse duration are tuned. Here, we analytically show that, under reasonable assumptions, the nested integrals that describe the light-matter interaction of the system can be simplified by application of the Fourier convolution and shift theorems, resulting in an expression for the nonlinear spectrum that is a product of the impulsive system response and the interaction laser spectra. The impulsive response can then be obtained by linearly dividing the laser spectrum from the detected signal. We demonstrate our normalization scheme by recovering the impulsive response from two different material systems, highlighting removal of distinct spectral artifacts.