MOMonika Ostapiuk

Monika Ostapiuk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Monika Ostapiuk has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of dentin changes induced by sodium hypochlorite and their impact on the microstructure and mechanical properties of teeth

    by Bożena Tarczydło, Zuzanna Kosior, Monika Ostapiuk

    Endodontic treatment is based on two complementary principles: mechanical and chemical preparation of the root canal system. Studies have demonstrated that endodontic instruments are capable of preparing only approximately 65-80% of the root canal wall surface, with the remaining substantial...

  • Open Access

    Compressive strength and fractographic analysis of tooth crown models made of a short glass fibre-reinforced composite material

    by Janusz Tarczydło, Monika Ostapiuk, Karolina Jurek, Bożena Tarczydło

    The objective of this study was to evaluate the compressive strength of a glass fibre reinforced (GFR) composite material used in restorative conservative dentistry. The following dental composites were used in the work: EverX Posterior (GC Europe) GFR composite and Filtek Z250 (3M ESPE)...

  • Open Access

    The Effect of Self-healing on the Corrosion Resistance of a Mg Alloy Promoted by Isocyanate Microcapsules of Polyurethane/Polyurea Shell

    by Monika Ostapiuk, Jarosław Bieniaś, Mónica V. Loureiro, Ana C. Marques

    Self-healing properties of materials are no longer in the realm of fantasy. Such materials are increasingly capable of aiding in diminishing and/or avoiding structural damage. Self-healing leads to microcapsules reconstructing the damaged area or scaling the damaged component. The main aim of the present work was to analyze the occurrence of corrosion in the AZ31 magnesium alloy in potentiodynamic and electrochemical impedance spectroscopy to study the behavior of microcapsules as a self-healing barrier layer. The study employed isophorone diisocyanate (IPDI) as the core of the microcapsules. The dominant mechanism of corrosion was pitting corrosion. The behavior of microcapsules confirms their applicability as self-healing agents against corrosion in magnesium alloys.


  • Open Access

    New Biodegradable Polyester–Polyurethane Biocompositions Enriched by Urea

    by Iwona Zarzyka, Beata Krzykowska, Karol Hęclik, Wiesław Frącz, Grzegorz Janowski, Łukasz Bąk, Tomasz Klepka, Jarosław Bieniaś, Monika Ostapiuk, Aneta Tor-Świątek, et al.

    Novel polyester–polyurethane polymeric materials were formulated by combining a natural aliphatic polyester, poly(3-hydroxybutyrate) (P3HB), with a synthetic aliphatic polyurethane via melt blending. The resulting fully biodegradable compositions were functionally modified through the incorporation of urea, with the aim of enabling post-consumer utilization of the material residues as nitrogen-rich fertilizers. The fabrication process was systematically established and optimized, focusing on homogeneous blending and processability. Comprehensive mechanical characterization—including tensile strength, impact resistance, and Shore hardness—was performed. Among the tested formulations, composites containing 1 wt.% urea demonstrated superior mechanical performance and optimal processing behavior. Fourier-transform infrared (FTIR) spectroscopy was employed to investigate molecular-level interactions between polymeric phases and urea, while scanning electron microscopy (SEM) was utilized to assess the morphological characteristics of the resulting biocompositions. Comparative analyses of the physico-mechanical properties and biodegradability were conducted among the urea-modified compositions, binary P3HB–polyurethane blends, and neat P3HB. The observed improvements in mechanical integrity and functional biodegradability suggest that the developed urea-enriched compositions are promising candidates for the fabrication of eco-friendly seedling pots via injection molding technology.


  • Open Access

    Treatment of Ochronotic Osteoarthropathy and the Evaluation of Selected Lower Limb Muscle Properties, Including the Patellar Tendon: A Case Report and Mini Literature Review

    by Jaromir Jarecki, Agnieszka Tomczyk-Warunek, Agnieszka Posturzyńska, Edward Warda, Marcin Waśko, Kamil Arciszewski, Ewa Tomaszewska, Siemowit Muszyński, Jarosław Bieniaś, Monika Ostapiuk, et al.

    Background/Objectives: Alkaptonuria (AKU) is a rare genetic disorder characterized by elevated levels of circulating homogentisic acid (HGA), which accumulates in connective tissues. The musculoskeletal system is particularly susceptible to HGA deposition, often resulting in severe ochronotic osteoarthropathy, especially in the hips, shoulders, knees, and spine. However, little is known about the effects of AKU on skeletal muscle tissue. The study aimed to evaluate changes in lower limb muscles associated with AKU. Methods: This case report describes the treatment of ochronotic osteoarthropathy in the knee of a 73-year-old male patient. Muscle properties were assessed using the MyotonPRO device. The rectus femoris, vastus medialis, and patellar tendon were examined both preoperatively and three months postoperatively. Results: Following total knee arthroplasty (TKA) of the right knee, the patient demonstrated significant improvement in functional outcomes. The MyotonPRO assessment revealed measurable differences in muscle properties between the operated and non-operated limbs. Postoperative measurements indicated improvements in muscle tone, elasticity, and viscoelastic parameters in the treated limb. Conclusions: This case report supports the effectiveness of TKA as a treatment for ochronotic osteoarthropathy. Furthermore, it is the first study to use the MyotonPRO to assess muscle and tendon properties in a patient with AKU. These findings highlight the need for further research into the muscular effects of this rare metabolic disorder.


  • Open Access

    Novel Research on Selected Mechanical and Environmental Properties of the Polyurethane-Based P3HB Nanobiocomposites

    by Iwona Zarzyka, Beata Krzykowska, Karol Hęclik, Wiesław Frącz, Grzegorz Janowski, Łukasz Bąk, Tomasz Klepka, Jarosław Bieniaś, Monika Ostapiuk, Aneta Tor-Świątek, et al.

    This study focused on hybrid nanobiocomposite polymers produced with the use of poly(3-hydroxybutyrate), P3HB and aliphatic polyurethane (PU) as a matrix, including variable quantities of organomodified montmorillonite (Cloisite®30B). Mechanical, thermal, and biodegradability tests were conducted to evaluate their properties. The nanobiocomposites were tested using monotonic tensile tests, which revealed that the addition of PU and organomodified montmorillonite reduced the stiffness and strain at break compared to native P3HB. The material’s yield strength was higher for P3HB, while the PU-modified composites exhibited lower stiffness and increased ductility, especially with lower amounts of clay. Scanning electron microscopy (SEM) images showed that cracks in the samples propagated more rapidly as the clay content increased. The bending test showed that the P3HB–PU composites and the nanobiocomposites exhibited lower bending strength and elongation at break compared to pure polyester. However, the composites with lower clay content showed better performance, suggesting that clay promotes ductility to some extent. The Charpy impact tests indicated an increase in impact strength for the composites with the addition of PU and montmorillonite, especially for the samples with 1 wt.% clay. Biodegradability testing showed that P3HB has a biodegradability of 63.21%. However, the addition of clay reduced biodegradability, with a notable decrease as the clay content increased. The biodegradation of composites with 1 and 2% by mass clay was higher than that of P3HB. Thermal analysis indicates an improvement in the thermal stability of the nanomaterials, with the 1% by mass clay sample showing the highest decomposition onset temperature (263 °C). Overall, the study demonstrated that the presence of PU and montmorillonite moderated the mechanical and thermal properties and biodegradation of P3HB, with the optimal performance observed in the composites with 1% by mass clay.


  • Open Access

    Modification of Poly(3-Hydroxybutyrate) with a Linear Polyurethane Modifier and Organic Nanofiller—Preparation and Structure–Property Relationship

    by Iwona Zarzyka, Beata Krzykowska, Karol Hęclik, Wiesław Frącz, Grzegorz Janowski, Łukasz Bąk, Tomasz Klepka, Jarosław Bieniaś, Monika Ostapiuk, Aneta Tor-Świątek, et al.

    The growing demand for products made of polymeric materials, including the commonly used polypropylene (PP), is accompanied by the problem of storing and disposing of non-biodegradable waste, increasing greenhouse gas emissions, climate change and the creation of toxic products that constitute a health hazard of all living organisms. Moreover, most of the synthetic polymers used are made from petrochemical feedstocks from non-renewable resources. The use of petrochemical raw materials also causes degradation of the natural environment. A potential solution to these problems is the use of biopolymers. Biopolymers include biodegradable or biosynthesizable polymers, i.e., obtained from renewable sources or produced synthetically but from raw materials of natural origin. One of them is the poly(3-hydroxybutyrate) (P3HB) biopolymer, whose properties are comparable to PP. Unfortunately, it is necessary to modify its properties to improve its processing and operational properties. In the work, hybrid polymer nanobiocomposites based on P3HB, with the addition of chain, uncross-linked polyurethane (PU) and layered aluminosilicate modified with organic salts (Cloisite®30B) were produced by extrusion process. The introduction of PU and Cloisite®30B to the polymer matrix (P3HB) influenced the processing parameters beneficially and resulted in a decrease in the extrusion temperature of more than 10 °C. The influence of the simultaneous addition of a constant amount of PU (10 m/m%) and the different amounts of nanoadditives (1, 2 and 3 m/m%) on the compatibility, morphology and static mechanical properties of the resulted nanobiocomposites were examined. The component interactions by Fourier transformation infrared spectroscopy (FTIR) analysis, nano- and microscale structure studies using small-angle X-ray scattering (SAXS) and morphology by scanning electron microscopy (SEM) were carried out, and the hardness and tensile strength of the obtained polymer nanobiocomposites were determined. FTIR analysis identified the compatibility of the polyester matrix, PU, and organomodified montmorillonite, the greatest being 3 m/m% Cloisite30B content. The addition of PU to the polyester elasticizes the material and decreases the material’s strength and ductility. The presence of nanoclay enhanced the mechanical properties of nanobiocomposites. The resulting nanobiocomposites can be used in the production of short-life materials applied in gardening or agriculture.


  • Open Access

    Imaging methods to evaluate the quality of root canal system filling by endodontic sealers used in in vitro studies

    by Justyna Kulik-Sajewicz, Agnieszka Kochmańska, Wojciech Wilkoński, Bożena Tarczydło, Monika Ostapiuk, Katarzyna Barczak

    Three-dimensional obturation of the root canal system is the primary goal of endodontic treatment. Endodontic sealers should fill any irregularities in the root canal system and penetrate as deeply as possible into the dentinal tubules. They should also ensure that the gutta-percha points adhere well to the dentinal walls of the root canal without leaving voids at their margins. The purpose of this study was to evaluate contemporary imaging techniques used for in vitro testing of selected specimens consisting of tooth scrapings after endodontic treatment with gutta-percha and selected endodontic sealers: AH Plus-Dentsply Sirona, Well Root ST-Vericon, Korea, and AH Bioceramics Sealer-Dentsply Sirona. The following imaging techniques were used in the evaluation: scanning electron microscopy (SEM), confocal laser scanning microscopy (CLSM), micro-computed tomography (micro-CT), surgical microscopy, and light microscopy. A comparison of the imaging methods (SEM, CLSM, micro-CT, surgical microscopy, light microscopy) showed significant differences in their suitability for assessing the penetration depth of endodontic sealers into dentinal tubules in vitro. Based on the analysis of the imaging methods, it was concluded that confocal microscopy and SEM were the most objective and accurate methods for visually assessing the quality of root canal filling in vitro. However, the high cost of specimen preparation and the limited availability of specialized equipment are factors that limit their use in clinical settings.

  • Open Access

    The Effect of Self-Healing Microcapsules in Corrosion Testing on Magnesium AZ31 Alloy and Fibre Metal Laminates

    by Monika Ostapiuk, Jarosław Bieniaś, Mónica V. Loureiro, Ana C. Marques

    Fibre metal laminates (FMLs) are the most interesting composite materials of the past decade. They possess the properties of both polymer composites and metallic alloys. However, there is a problem with corrosion when the outer layers are made of aluminium or magnesium. The electrochemical changes that occur during the corrosion process and the mechanisms associated with the corrosion phenomenon are still being investigated. Recently, self-healing phenomena have emerged as a useful approach to prevent corrosion. However, there is limited research on the combination of FMLs and self-healing layers. Therefore, the main purpose of this article is to evaluate the self-healing ability of a magnesium/PEO layer based on microcapsules in a corrosion environment. It was observed that the corrosion mechanism in magnesium alloys is very complex. However, the use of a barrier layer with PEO treatment and microcapsules yielded positive anti-corrosion results. The FML samples were subjected to a 6-week corrosion test, and the addition of microcapsules to the layers showed positive results. In contrast, the samples without microcapsules exhibited intergranular corrosion. In the future, comprehensive tests using self-healing microcapsules in FMLs could greatly enhance their anti-corrosion properties and improve the integrity of the structure.


  • Open Access

    Compressive Strength Testing of Glass-Fibre-Reinforced Tooth Crown Tissues After Endodontic Treatment

    by Monika Ostapiuk, Janusz Tarczydło, Katarzyna Kamińska, Barbara Surowska, Bożena Tarczydło

    The objective of this study was to compare the effects of using short and continuous fibres for repairing compression-induced tooth crown damage. Human teeth were used for the study. They were upper medial incisors and maxillary first premolars lost due to periodontal causes. The teeth were divided into two groups with Hahnenkratt and short glass fibres. Teeth compressive strength tests were carried out. Then micro-CT imaging of the teeth and their fractures obtained after compression was performed. The teeth restored with Hahnenkratt’s glass fibre posts showed higher compressive strength than the teeth restored using the EverX Posterior material. The tooth’s most weakened and sensitive point after endodontic treatment was the cervical area of the tooth. All cracks were parallel to the root canal.