Mathias Glehr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mathias Glehr has a total of 173 co-authors. Here are the top co-authors by number of shared publications:
- Reinhard Windhager
Department of Orthopaedics and Trauma Surgery, Medical University of Vienna, 1090 Vienna, Austria
17 shared publications - Andreas Leithner
Department of Orthopaedics and Trauma Medical University of Graz Graz Austria
14 shared publications - Patrick Sadoghi
Department of Orthopaedics and Trauma Medical University of Graz Graz Austria
12 shared publications Andreas Leithner
7 shared publicationsG. Gruber
Medical University of Graz
7 shared publications- Gerald Gruber
Department of Orthopaedic Surgery, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria
6 shared publications
Latest Publications
- Open Access
- 21 December 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-9
Local anaesthesia vs. brachial plexus block in trapeziometacarpal joint arthroplasty
Introduction: An established anaesthetic procedure used during total trapeziometacarpal joint (TMCJ) arthroplasty is the brachial plexus block (BPB). It was hypothesized that local anaesthesia (LA) provides advantages in overall cost, enables intraoperative assessment of the prosthesis, and minimises the anaesthetic risk. In this study, LA to BPB was compared and outcomes, safety, and overall patient satisfaction were analyzed. Materials and methods: In this single-center cohort study, 32 patients (34 operated thumbs) who underwent total TMCJ arthroplasty between February 2018 and July 2021 were included. Two groups were formed depending on the anaesthetic method used. One group was operated under LA, and the other under BPB. Functionality scores were assessed preoperatively and three month postoperatively. Additionally, pain was assessed on the 1st and 12th postoperative day. Data on intraoperative pain and anxiety, overall satisfaction, pain medication use, and willingness to undergo the procedure again were gathered through a retrospective telephone survey. Results: No significant differences between LA and BPB were found in terms of functional outcomes, pain reduction, and willingness to repeat the procedure. The analysis further showed significant differences in intraoperative anxiety (higher in the LA group; LA 1.69, SD: 2.65; BPB 0.28, SD: 0.58; measured using a numeric rating scale 0–10; p = 0.045), operation length (higher in BPB group; LA 39 min, SD: 7.46; BPB 45 min, SD: 7.02; p = 0.018) and overall setup time (higher in BPB group; LA 76 min, SD: 15.85; BPB 102 min, SD: 19.66; p < 0.001). No conversion from LA to another anaesthetic method was necessary. Conclusion: The use of LA in total TMCJ arthroplasty is a practical and reliable alternative to the well-established BPB. LA reduces the cost of the procedure, necessity of an anaesthesiology team and the duration of the patients´ hospital stay. Patients should be actively involved in selecting the anaesthetic method to optimize the operative procedure and overall outcome.
- 21 December 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-9
Open AccessLocal anaesthesia vs. brachial plexus block in trapeziometacarpal joint arthroplasty
Introduction: An established anaesthetic procedure used during total trapeziometacarpal joint (TMCJ) arthroplasty is the brachial plexus block (BPB). It was hypothesized that local anaesthesia (LA) provides advantages in overall cost, enables intraoperative assessment of the prosthesis, and minimises the anaesthetic risk. In this study, LA to BPB was compared and outcomes, safety, and overall patient satisfaction were analyzed. Materials and methods: In this single-center cohort study, 32 patients (34 operated thumbs) who underwent total TMCJ arthroplasty between February 2018 and July 2021 were included. Two groups were formed depending on the anaesthetic method used. One group was operated under LA, and the other under BPB. Functionality scores were assessed preoperatively and three month postoperatively. Additionally, pain was assessed on the 1st and 12th postoperative day. Data on intraoperative pain and anxiety, overall satisfaction, pain medication use, and willingness to undergo the procedure again were gathered through a retrospective telephone survey. Results: No significant differences between LA and BPB were found in terms of functional outcomes, pain reduction, and willingness to repeat the procedure. The analysis further showed significant differences in intraoperative anxiety (higher in the LA group; LA 1.69, SD: 2.65; BPB 0.28, SD: 0.58; measured using a numeric rating scale 0–10; p = 0.045), operation length (higher in BPB group; LA 39 min, SD: 7.46; BPB 45 min, SD: 7.02; p = 0.018) and overall setup time (higher in BPB group; LA 76 min, SD: 15.85; BPB 102 min, SD: 19.66; p < 0.001). No conversion from LA to another anaesthetic method was necessary. Conclusion: The use of LA in total TMCJ arthroplasty is a practical and reliable alternative to the well-established BPB. LA reduces the cost of the procedure, necessity of an anaesthesiology team and the duration of the patients´ hospital stay. Patients should be actively involved in selecting the anaesthetic method to optimize the operative procedure and overall outcome.
- Open Access
- 29 October 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 39 (8) , 1700-1709
Risk of reinfection after two‐ or multiple‐stage knee revision surgery using superficial vancomycin coating and conventional spacers
This study investigates the effect of superficial vancomycin coating (SVC) in two‐ or more‐stage exchange procedures of prosthetic knee joint infections. We hypothesized that spacer treatment with SVC result in lower reinfection rates than conventional spacers after prosthetic reimplantation. Our secondary aim was to determine the demographic and treatment factors associated with reinfection rates. This retrospective cohort study compromised 96 cases with prosthetic knee infections. Twenty‐four cases were treated with a temporary SVC spacer and 72 cases with conventional spacers. Prosthetic reinfection occurred after a median observation period of 1.7 ± 4.0 years in 24 cases (25%). The prevalence of having a reinfection was not significantly different between the two treatment groups (13% [3 cases] in the SVC group vs. 29% [21 cases] in the conventional spacer group [p = .104]). In seven cases (7.3%), two in the SVC group (8.3%) and five (6.9%) in the conventional spacer group (p ≥ .999), histological, respectively microbiological evaluations from the intraoperative specimens revealed persistent infection at the second stage. Nevertheless, in all seven cases no significant higher risk of periprosthetic reinfection was observed during follow‐up (p = .750). Our secondary investigation of cofactors revealed that spacers additionally stabilized by nails were significantly associated with a 3.9‐fold higher hazard ratio of sustaining a reinfection of revision prosthesis (p = .005).
- 29 October 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 39 (8) , 1700-1709
Open AccessRisk of reinfection after two‐ or multiple‐stage knee revision surgery using superficial vancomycin coating and conventional spacers
This study investigates the effect of superficial vancomycin coating (SVC) in two‐ or more‐stage exchange procedures of prosthetic knee joint infections. We hypothesized that spacer treatment with SVC result in lower reinfection rates than conventional spacers after prosthetic reimplantation. Our secondary aim was to determine the demographic and treatment factors associated with reinfection rates. This retrospective cohort study compromised 96 cases with prosthetic knee infections. Twenty‐four cases were treated with a temporary SVC spacer and 72 cases with conventional spacers. Prosthetic reinfection occurred after a median observation period of 1.7 ± 4.0 years in 24 cases (25%). The prevalence of having a reinfection was not significantly different between the two treatment groups (13% [3 cases] in the SVC group vs. 29% [21 cases] in the conventional spacer group [p = .104]). In seven cases (7.3%), two in the SVC group (8.3%) and five (6.9%) in the conventional spacer group (p ≥ .999), histological, respectively microbiological evaluations from the intraoperative specimens revealed persistent infection at the second stage. Nevertheless, in all seven cases no significant higher risk of periprosthetic reinfection was observed during follow‐up (p = .750). Our secondary investigation of cofactors revealed that spacers additionally stabilized by nails were significantly associated with a 3.9‐fold higher hazard ratio of sustaining a reinfection of revision prosthesis (p = .005).
- Open Access
- 25 July 2020
- Published by Springer Nature in International Orthopaedics
- Vol. 44 (12) , 2515-2520
Combined serum biomarker analysis shows no benefit in the diagnosis of periprosthetic joint infection
Purpose: In many cases, the diagnosis of a periprosthetic joint infection (PJI) consisting of the clinical appearance, laboratory tests, and other diagnostic tools remains a difficult task. Single serum biomarkers are easy to collect, are suitable for periodical assessment, and are a crucial tool in PJI diagnosis, but limited sensitivity or specificity is reported in literature. The aim of this study was to combine the best-performing single serum biomarkers into a multi-biomarker model aiming to improve the diagnostic properties. Methods: Within a 27-month period, 124 surgical procedures (aseptic or septic revision total knee arthroplasty (TKA) or total hip arthroplasty (THA)) were prospectively included. The serum leukocyte count, C-reactive protein (CRP), interleukin-6, procalcitonin, interferon alpha, and fibrinogen were assessed 1 day prior to surgery. Logistic regression with lasso-regularization was used for the biomarkers and all their ratios. After randomly splitting the data into a training (75%) and a test set (25%), the multi-biomarker model was calculated and validated in a cross-validation approach. Results: CRP (AUC 0.91, specificity 0.67, sensitivity 0.90, p value 0.03) and fibrinogen (AUC 0.93, specificity 0.73, sensitivity 0.94, p value 0.02) had the best single-biomarker performances. The multi-biomarker model including fibrinogen, CRP, the ratio of fibrinogen to CRP, and the ratio of serum thrombocytes to CRP showed a similar performance (AUC 0.95, specificity 0.91, sensitivity 0.72, p value 0.01). Conclusion: In this study, multiple biomarkers were tested for their diagnostic performance, with CRP and fibrinogen showing the best results regarding the AUC, accuracy, sensitivity, and specificity. It was not possible to further increase the diagnostic accuracy by combining multiple biomarkers using sophisticated statistical methods.
- 25 July 2020
- Published by Springer Nature in International Orthopaedics
- Vol. 44 (12) , 2515-2520
Open AccessCombined serum biomarker analysis shows no benefit in the diagnosis of periprosthetic joint infection
Purpose: In many cases, the diagnosis of a periprosthetic joint infection (PJI) consisting of the clinical appearance, laboratory tests, and other diagnostic tools remains a difficult task. Single serum biomarkers are easy to collect, are suitable for periodical assessment, and are a crucial tool in PJI diagnosis, but limited sensitivity or specificity is reported in literature. The aim of this study was to combine the best-performing single serum biomarkers into a multi-biomarker model aiming to improve the diagnostic properties. Methods: Within a 27-month period, 124 surgical procedures (aseptic or septic revision total knee arthroplasty (TKA) or total hip arthroplasty (THA)) were prospectively included. The serum leukocyte count, C-reactive protein (CRP), interleukin-6, procalcitonin, interferon alpha, and fibrinogen were assessed 1 day prior to surgery. Logistic regression with lasso-regularization was used for the biomarkers and all their ratios. After randomly splitting the data into a training (75%) and a test set (25%), the multi-biomarker model was calculated and validated in a cross-validation approach. Results: CRP (AUC 0.91, specificity 0.67, sensitivity 0.90, p value 0.03) and fibrinogen (AUC 0.93, specificity 0.73, sensitivity 0.94, p value 0.02) had the best single-biomarker performances. The multi-biomarker model including fibrinogen, CRP, the ratio of fibrinogen to CRP, and the ratio of serum thrombocytes to CRP showed a similar performance (AUC 0.95, specificity 0.91, sensitivity 0.72, p value 0.01). Conclusion: In this study, multiple biomarkers were tested for their diagnostic performance, with CRP and fibrinogen showing the best results regarding the AUC, accuracy, sensitivity, and specificity. It was not possible to further increase the diagnostic accuracy by combining multiple biomarkers using sophisticated statistical methods.
- Open Access
Titanium-Nitride Coating Does Not Result in a Better Clinical Outcome Compared to Conventional Cobalt-Chromium Total Knee Arthroplasty after a Long-Term Follow-Up: A Propensity Score Matching Analysis
Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.
Open AccessTitanium-Nitride Coating Does Not Result in a Better Clinical Outcome Compared to Conventional Cobalt-Chromium Total Knee Arthroplasty after a Long-Term Follow-Up: A Propensity Score Matching Analysis
Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.
- 24 August 2018
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 33 (12) , 3734-3738
Septic Revision Total Knee Arthroplasty: Treatment of Metaphyseal Bone Defects Using Metaphyseal Sleeves
- 24 August 2018
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 33 (12) , 3734-3738
Septic Revision Total Knee Arthroplasty: Treatment of Metaphyseal Bone Defects Using Metaphyseal Sleeves
- 27 February 2015
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 127 (13-14) , 561-566
Limb salvage and functional outcomes among patients with traumatic popliteal artery injury: a review of 64 cases
Traumatic popliteal arterial injury carries the greatest risk of limb loss among all peripheral vascular injuries and is associated with high levels of morbidity and worse functional outcomes. The purpose of this study is to analyse the functional outcome among patients with popliteal artery injury (PAI) due to blunt and penetrating trauma and identify influencing factors. We critically reviewed 64 cases of PAI due to blunt and penetrating trauma treated at our institution over a 20-year period. We evaluated the influence of parameters, such as patient demographics, injury mechanism, initial ISS and performed interventions, on limb amputation rates and functional outcomes. Functional outcome was examined within the 12-months follow-up using the Functional Independence Measure (FIM) score for feeding, expression and locomotion. FIM scores for each category ranged from 1 (full assistance required) to 4 (fully independent), with a maximum total FIM score of 12 representing full independence. The mechanism of injury was blunt in 55 % and penetrating in 45 % of the patients. The overall amputation rate in our series was 28 %. Out of these, 83.3 % of all performed amputations in our series were due to blunt trauma and 88.6 % of all blunt trauma patients were severely injured (ISS > 9) or polytraumatized (ISS > 15). Blunt mechanism of injury has also shown a negative effect on the functional outcome. Analysis of the 1-year clinical follow-up showed that 30 patients (65.3 %) returned to their normal activity level within 1 year after trauma. A total of 16 patients (34.7 %) were recorded to have limited activity levels, 76.5 % of them sustained a blunt trauma. Using the FIM score to quantify the level of disability, we detected significantly worse results in both FIM total (8.8 vs. 10.4) and FIM locomotion score (3.1 vs. 2.7) following blunt trauma. The main findings of the present study were that PAI due to blunt trauma is associated with a high percentage of severely injured or even polytraumatized patients. Amputation rates following blunt trauma were significantly higher compared to penetrating trauma. Functional independence measurement, assessed 12 months after injury, also showed significantly worse results in both FIM total and FIM locomotion score after blunt trauma. Other factors that seem to have a negative influence on the outcome in terms of amputation rates after PAI are patient’s age, presence of associated injuries and prolonged lower extremity ischemia.
- 27 February 2015
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 127 (13-14) , 561-566
Limb salvage and functional outcomes among patients with traumatic popliteal artery injury: a review of 64 cases
Traumatic popliteal arterial injury carries the greatest risk of limb loss among all peripheral vascular injuries and is associated with high levels of morbidity and worse functional outcomes. The purpose of this study is to analyse the functional outcome among patients with popliteal artery injury (PAI) due to blunt and penetrating trauma and identify influencing factors. We critically reviewed 64 cases of PAI due to blunt and penetrating trauma treated at our institution over a 20-year period. We evaluated the influence of parameters, such as patient demographics, injury mechanism, initial ISS and performed interventions, on limb amputation rates and functional outcomes. Functional outcome was examined within the 12-months follow-up using the Functional Independence Measure (FIM) score for feeding, expression and locomotion. FIM scores for each category ranged from 1 (full assistance required) to 4 (fully independent), with a maximum total FIM score of 12 representing full independence. The mechanism of injury was blunt in 55 % and penetrating in 45 % of the patients. The overall amputation rate in our series was 28 %. Out of these, 83.3 % of all performed amputations in our series were due to blunt trauma and 88.6 % of all blunt trauma patients were severely injured (ISS > 9) or polytraumatized (ISS > 15). Blunt mechanism of injury has also shown a negative effect on the functional outcome. Analysis of the 1-year clinical follow-up showed that 30 patients (65.3 %) returned to their normal activity level within 1 year after trauma. A total of 16 patients (34.7 %) were recorded to have limited activity levels, 76.5 % of them sustained a blunt trauma. Using the FIM score to quantify the level of disability, we detected significantly worse results in both FIM total (8.8 vs. 10.4) and FIM locomotion score (3.1 vs. 2.7) following blunt trauma. The main findings of the present study were that PAI due to blunt trauma is associated with a high percentage of severely injured or even polytraumatized patients. Amputation rates following blunt trauma were significantly higher compared to penetrating trauma. Functional independence measurement, assessed 12 months after injury, also showed significantly worse results in both FIM total and FIM locomotion score after blunt trauma. Other factors that seem to have a negative influence on the outcome in terms of amputation rates after PAI are patient’s age, presence of associated injuries and prolonged lower extremity ischemia.
- Open Access
- 24 July 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 250
Quality of life after volar locked plating: a 10-year follow-up study of patients with intra-articular distal radius fractures
This study aimed to present functional results and patient’s health related quality of life (HRQOL) data ten years after volar locked plate fixation (VPF) of unstable intra-articular distal radial fractures (DRF).
- 24 July 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 250
Open AccessQuality of life after volar locked plating: a 10-year follow-up study of patients with intra-articular distal radius fractures
This study aimed to present functional results and patient’s health related quality of life (HRQOL) data ten years after volar locked plate fixation (VPF) of unstable intra-articular distal radial fractures (DRF).
- Open Access
- 3 February 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-5
Physician Awareness of Knee and Hip Pain in the Context of Coronary Heart Disease Treatment
Background. The benefit of physical activity for the prevention and treatment of cardiovascular disease (CVD) has been well documented. The aim of the present study was to determine the level of awareness among general practitioners (GPs) of knee and hip problems in patients with CVD or CVD risk.Design. Cross-sectional questionnaire survey.Setting and Subjects. Thirty-five Austrian GPs and 1,118 patients were included. The GPs completed an extraction form about the presence or absence of documented evidence of problems related to the knee and/or hip joint within the patient medical data. Patients, in turn, were asked to complete a questionnaire that included the Oxford Knee/Hip Score and the cardiovascular risk-chart established by the European Society of Cardiology.Results. In 748 patients’ data from medical records and questionnaires were available. 40.9% of these patients suffered from serious knee pain and 32.1% from hip pain. However, in the medical records, in only 51.3% (knee) and 48.1% (hip) of these pain-patients the problems were documented.Conclusion. Joint disorders of the knee and hip problems are considerable barriers to effective physical activity and can therefore contribute to the development of CVD. Our data showed that GP awareness of such knee/hip disorders should be improved.
- 3 February 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-5
Open AccessPhysician Awareness of Knee and Hip Pain in the Context of Coronary Heart Disease Treatment
Background. The benefit of physical activity for the prevention and treatment of cardiovascular disease (CVD) has been well documented. The aim of the present study was to determine the level of awareness among general practitioners (GPs) of knee and hip problems in patients with CVD or CVD risk.Design. Cross-sectional questionnaire survey.Setting and Subjects. Thirty-five Austrian GPs and 1,118 patients were included. The GPs completed an extraction form about the presence or absence of documented evidence of problems related to the knee and/or hip joint within the patient medical data. Patients, in turn, were asked to complete a questionnaire that included the Oxford Knee/Hip Score and the cardiovascular risk-chart established by the European Society of Cardiology.Results. In 748 patients’ data from medical records and questionnaires were available. 40.9% of these patients suffered from serious knee pain and 32.1% from hip pain. However, in the medical records, in only 51.3% (knee) and 48.1% (hip) of these pain-patients the problems were documented.Conclusion. Joint disorders of the knee and hip problems are considerable barriers to effective physical activity and can therefore contribute to the development of CVD. Our data showed that GP awareness of such knee/hip disorders should be improved.
- 27 September 2013
- Vol. 68, 336-42
The influence of resveratrol on the synovial expression of matrix metalloproteinases and receptor activator of NF-kappaB ligand in rheumatoid arthritis fibroblast-like synoviocytes.
Medication of rheumatoid arthritis (RA) remains challenging and often controversial concerning side effects or long-term complications. We investigated the effect of resveratrol, a phytoalexin discussed for its chondro-protective and anti-inflammatory qualities, on the synovial expression of matrix-degrading enzymes like matrix metalloproteinases (MMPs) and bone-remodelling proteins in RA fibroblast-like synoviocytes (FLS). Interleukin-1beta-stimulated RA-FLS were treated with 100 microM resveratrol for 24 h. To evaluate the effect of resveratrol on the amount of bound/combined MMPs, a Luminex xMAP multiplexing technology was used. The alteration in expression of receptor activator of nuclear factor-kappaB ligand (RANKL) and osteoprotegrin (OPG) was measured by quantitative real-time polymerase chain reaction (qRT-PCR). Resveratrol reduced the expression of MMP-1 (p = 0.022), MMP-3 (p = 0.021), and MMP-9 (p = 0.047). qRT-PCR showed a significant reduction in the relative abundance of the transcripts of OPG (p = 0.012) and RANKL (p = 0.018). Our in vitro findings indicate that resveratrol could be a new target for further pharmacological studies in the field of RA. In the future it could play a role as a possible substitute or supplement to currently used drugs against RA to prevent cartilage matrix degradation and pathological bone resorption due to inhibition of MMPs and RANKL.
- 27 September 2013
- Vol. 68, 336-42
The influence of resveratrol on the synovial expression of matrix metalloproteinases and receptor activator of NF-kappaB ligand in rheumatoid arthritis fibroblast-like synoviocytes.
Medication of rheumatoid arthritis (RA) remains challenging and often controversial concerning side effects or long-term complications. We investigated the effect of resveratrol, a phytoalexin discussed for its chondro-protective and anti-inflammatory qualities, on the synovial expression of matrix-degrading enzymes like matrix metalloproteinases (MMPs) and bone-remodelling proteins in RA fibroblast-like synoviocytes (FLS). Interleukin-1beta-stimulated RA-FLS were treated with 100 microM resveratrol for 24 h. To evaluate the effect of resveratrol on the amount of bound/combined MMPs, a Luminex xMAP multiplexing technology was used. The alteration in expression of receptor activator of nuclear factor-kappaB ligand (RANKL) and osteoprotegrin (OPG) was measured by quantitative real-time polymerase chain reaction (qRT-PCR). Resveratrol reduced the expression of MMP-1 (p = 0.022), MMP-3 (p = 0.021), and MMP-9 (p = 0.047). qRT-PCR showed a significant reduction in the relative abundance of the transcripts of OPG (p = 0.012) and RANKL (p = 0.018). Our in vitro findings indicate that resveratrol could be a new target for further pharmacological studies in the field of RA. In the future it could play a role as a possible substitute or supplement to currently used drugs against RA to prevent cartilage matrix degradation and pathological bone resorption due to inhibition of MMPs and RANKL.
- 6 September 2013
- Published by Springer Nature in Surgical Endoscopy
- Vol. 28 (2) , 439-446
Health-related quality of life after TAPP repair for the sportsmen’s groin
- 6 September 2013
- Published by Springer Nature in Surgical Endoscopy
- Vol. 28 (2) , 439-446
Health-related quality of life after TAPP repair for the sportsmen’s groin