Maryam Ghahramani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maryam Ghahramani has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Raul Fernandez Rojas
Faculty of Science and Technology, University of Canberra, Canberra, Australia
11 shared publications - Maryam Sousani
Faculty of Science and Technology, University of Canberra, Canberra, Australia
5 shared publications - Elisabeth Preston
University of Canberra
4 shared publications - Roland Goecke
University of New South Wales, Canberra, Australia
4 shared publications - Abishek Shrestha
Faculty of Science and Technology, University of Canberra (UC), Bruce, ACT 2617, Australia
2 shared publications - Angie Fearon
Faculty of Health, University of Canberra, Office 13, Clinical Education and Research Centre, UC Hospital, Canberra, Australia
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-11
Engagement Mediates Virtual Reality Pain Relief: A Within-Subject Analysis
- 16 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-11
Open AccessEngagement Mediates Virtual Reality Pain Relief: A Within-Subject Analysis
- Open Access
Technical and Clinical Validation of a Portable Optical Fibre Balance Mat for Quantifying Postural Sway in Older Adults
Background: Early identification of balance impairments is critical for detecting the fall risk in older adults. Force plates are the standard for measuring postural sway, but are restricted in practice because they are cumbersome and expensive. The Balance Mat is a portable device that requires comprehensive validation against force plates and clinical benchmarks in older adult populations. Objective: The objective of this study was to evaluate the technical validity and clinical discriminative ability of the Balance Mat against a laboratory-grade force plate, clinical tests, and the fall history in an older adult cohort. Methods: Fifty-six community-dwelling older adults performed static balance assessments across six stance conditions. Postural sway data were recorded simultaneously using the Balance Mat and a force plate. The technical validity was assessed using Spearman’s rank correlation and intraclass correlation coefficients. Linear regression models were applied to calibrate the Balance Mat outputs against the force plate. The diagnostic accuracy for classifying the fall risk against the timed up and go test, the Falls Efficacy Scale-International, and the retrospective fall history was evaluated using an area-under-the-curve analysis. Results: The Balance Mat demonstrated strong associations with force plate measurements, particularly for the sway path/velocity, variance and Area95 (). Following calibration, the absolute agreement for the sway path/velocity reached excellent levels () and good levels for Area95 and RMS (), whereas the mean sway demonstrated a poor agreement and was excluded. For fall-risk classification, the calibrated Balance Mat achieved a fair accuracy for the retrospective fall history and a high Falls Efficacy Scale-International concern (area under the curve, 0.76–0.78), and a fair accuracy for the timed up and go thresholds (area under the curve, 0.70). Conclusions: The calibrated Balance Mat provided valid measurements of postural sway that aligned with the force plate parameters, particularly for the sway path/velocity and Area95. The within-stance agreement for the sway path/velocity ranged from ICC = 0.44 to 0.88, and the pooled value should not be interpreted as the uniform performance across all stance conditions. Given its fair diagnostic accuracy, the device is best utilised as a portable screening tool in combination with standard clinical assessments and the fall history rather than as a standalone diagnostic test.Open AccessTechnical and Clinical Validation of a Portable Optical Fibre Balance Mat for Quantifying Postural Sway in Older Adults
Background: Early identification of balance impairments is critical for detecting the fall risk in older adults. Force plates are the standard for measuring postural sway, but are restricted in practice because they are cumbersome and expensive. The Balance Mat is a portable device that requires comprehensive validation against force plates and clinical benchmarks in older adult populations. Objective: The objective of this study was to evaluate the technical validity and clinical discriminative ability of the Balance Mat against a laboratory-grade force plate, clinical tests, and the fall history in an older adult cohort. Methods: Fifty-six community-dwelling older adults performed static balance assessments across six stance conditions. Postural sway data were recorded simultaneously using the Balance Mat and a force plate. The technical validity was assessed using Spearman’s rank correlation and intraclass correlation coefficients. Linear regression models were applied to calibrate the Balance Mat outputs against the force plate. The diagnostic accuracy for classifying the fall risk against the timed up and go test, the Falls Efficacy Scale-International, and the retrospective fall history was evaluated using an area-under-the-curve analysis. Results: The Balance Mat demonstrated strong associations with force plate measurements, particularly for the sway path/velocity, variance and Area95 (). Following calibration, the absolute agreement for the sway path/velocity reached excellent levels () and good levels for Area95 and RMS (), whereas the mean sway demonstrated a poor agreement and was excluded. For fall-risk classification, the calibrated Balance Mat achieved a fair accuracy for the retrospective fall history and a high Falls Efficacy Scale-International concern (area under the curve, 0.76–0.78), and a fair accuracy for the timed up and go thresholds (area under the curve, 0.70). Conclusions: The calibrated Balance Mat provided valid measurements of postural sway that aligned with the force plate parameters, particularly for the sway path/velocity and Area95. The within-stance agreement for the sway path/velocity ranged from ICC = 0.44 to 0.88, and the pooled value should not be interpreted as the uniform performance across all stance conditions. Given its fair diagnostic accuracy, the device is best utilised as a portable screening tool in combination with standard clinical assessments and the fall history rather than as a standalone diagnostic test. - Open Access
- 22 May 2026
- Published by MDPI AG in Preprints.org
Technical and Clinical Validation of a Portable Optical Fibre Balance Mat for Quantifying Postural Sway in Older Adults
Background: Early identification of balance impairments is critical for detecting fall risk in older adults. Force plates are the standard for measuring postural sway but are restricted in practice because they are cumbersome and expensive. The Balance Mat is a portable device that requires comprehensive validation against force plates and clinical benchmarks in older adult populations. Objective: To evaluate the technical validity and clinical discriminative ability of the Balance Mat against a laboratory-grade force plate, clinical tests, and falls history in an older adult cohort. Methods: Fifty-six community-dwelling older adults performed static balance assessments across six stance conditions. Postural sway data were recorded simultaneously using the Balance Mat and a force plate. Technical validity was assessed using Spearman’s rank correlation and Intraclass Correlation Coefficients. Linear regression models were applied to calibrate Balance Mat outputs against the force plate. Diagnostic accuracy for classifying fall risk against the Timed Up and Go test, Falls Efficacy Scale-International, and retrospective falls history was evaluated using Area Under the Curve analysis. Results: The Balance Mat demonstrated strong associations with force plate measurements, particularly for sway path and sway velocity (r=0.851). Following calibration, absolute agreement for these parameters reached excellent levels (ICC=0.93), whereas mean sway demonstrated poor agreement and was excluded. For fall-risk classification, the calibrated Balance Mat achieved fair accuracy for retrospective falls history and high Falls Efficacy Scale-International concern (Area Under the Curve 0.74-0.78) and moderate accuracy for Timed Up and Go thresholds (Area Under the Curve 0.70). Conclusion: The calibrated Balance Mat provides valid measurements of postural sway that align with force plate parameters, particularly for sway path and velocity. Given its fair diagnostic accuracy, the device is best utilised as a portable screening tool in combination with standard clinical assessments and falls history rather than as a standalone diagnostic test.
- 22 May 2026
- Published by MDPI AG in Preprints.org
Open AccessTechnical and Clinical Validation of a Portable Optical Fibre Balance Mat for Quantifying Postural Sway in Older Adults
Background: Early identification of balance impairments is critical for detecting fall risk in older adults. Force plates are the standard for measuring postural sway but are restricted in practice because they are cumbersome and expensive. The Balance Mat is a portable device that requires comprehensive validation against force plates and clinical benchmarks in older adult populations. Objective: To evaluate the technical validity and clinical discriminative ability of the Balance Mat against a laboratory-grade force plate, clinical tests, and falls history in an older adult cohort. Methods: Fifty-six community-dwelling older adults performed static balance assessments across six stance conditions. Postural sway data were recorded simultaneously using the Balance Mat and a force plate. Technical validity was assessed using Spearman’s rank correlation and Intraclass Correlation Coefficients. Linear regression models were applied to calibrate Balance Mat outputs against the force plate. Diagnostic accuracy for classifying fall risk against the Timed Up and Go test, Falls Efficacy Scale-International, and retrospective falls history was evaluated using Area Under the Curve analysis. Results: The Balance Mat demonstrated strong associations with force plate measurements, particularly for sway path and sway velocity (r=0.851). Following calibration, absolute agreement for these parameters reached excellent levels (ICC=0.93), whereas mean sway demonstrated poor agreement and was excluded. For fall-risk classification, the calibrated Balance Mat achieved fair accuracy for retrospective falls history and high Falls Efficacy Scale-International concern (Area Under the Curve 0.74-0.78) and moderate accuracy for Timed Up and Go thresholds (Area Under the Curve 0.70). Conclusion: The calibrated Balance Mat provides valid measurements of postural sway that align with force plate parameters, particularly for sway path and velocity. Given its fair diagnostic accuracy, the device is best utilised as a portable screening tool in combination with standard clinical assessments and falls history rather than as a standalone diagnostic test.
- Open Access
Real-Time Pain Assessment from Electrodermal Activity Using Deep Learning
Objective pain assessment remains a significant challenge in clinical and research settings due to the subjective nature of self-reported measures. Physiological signals, particularly electrodermal activity (EDA), have emerged as promising indicators of autonomic responses associated with pain. Although recent advances in deep learning have improved the modelling of complex biosignals, many existing approaches remain computationally demanding, limiting their applicability for real-time monitoring in wearable and embedded systems. This paper proposes a fully convolutional network (FCN) for automated pain recognition using EDA signals. The proposed model is designed to efficiently capture temporal patterns in physiological data while maintaining low computational complexity. The approach is evaluated on the AI4Pain dataset for three-class pain classification (No Pain, Low Pain, High Pain). Experimental results show that the proposed FCN achieves an accuracy of 79.23% in offline evaluation. Furthermore, the model enables real-time inference with a latency of 0.47 ms, achieving 73.14% accuracy during real-time operation. These results demonstrate that convolutional architectures can provide an effective balance between predictive performance and computational efficiency, supporting the development of real-time physiological pain monitoring systems using wearable sensing technologies.
Open AccessReal-Time Pain Assessment from Electrodermal Activity Using Deep Learning
Objective pain assessment remains a significant challenge in clinical and research settings due to the subjective nature of self-reported measures. Physiological signals, particularly electrodermal activity (EDA), have emerged as promising indicators of autonomic responses associated with pain. Although recent advances in deep learning have improved the modelling of complex biosignals, many existing approaches remain computationally demanding, limiting their applicability for real-time monitoring in wearable and embedded systems. This paper proposes a fully convolutional network (FCN) for automated pain recognition using EDA signals. The proposed model is designed to efficiently capture temporal patterns in physiological data while maintaining low computational complexity. The approach is evaluated on the AI4Pain dataset for three-class pain classification (No Pain, Low Pain, High Pain). Experimental results show that the proposed FCN achieves an accuracy of 79.23% in offline evaluation. Furthermore, the model enables real-time inference with a latency of 0.47 ms, achieving 73.14% accuracy during real-time operation. These results demonstrate that convolutional architectures can provide an effective balance between predictive performance and computational efficiency, supporting the development of real-time physiological pain monitoring systems using wearable sensing technologies.
- Open Access
Connectivity-Based Pain Recognition from fNIRS: Parsimonious Subject-Independent Classification
Accurate pain assessment remains challenging, because pain is subjective, and common clinical tools rely on self-report or observation. Functional near-infrared spectroscopy (fNIRS) provides a non-invasive window into cortical haemodynamics and shows promise for objective pain assessment. In this study, we propose a subject-independent framework that models pain states using functional and effective connectivity features derived from fNIRS signals. Using the AI4PAIN dataset (65 participants, 24 channels), we extracted correlation, partial correlation, coherence, and Granger causality matrices from haemodynamic signals (HbO2, HHb, and HbT), yielding a comprehensive connectivity feature space. A three-class classification task (No Pain vs. Low Pain vs. High Pain) was evaluated using leave-one-subject-out (LOSO) cross-validation. Within each training fold, we standardised features and applied mutual-information-based feature selection; a systematic sweep showed that a reduced feature set of 700 connectivity features achieves performance comparable to the full 1380 features and constitutes the minimum configuration at which High Pain instances begin to be detected (High Pain recall ≈ 50%), whereas smaller feature sets produce near-zero High Pain recall. The proposed framework achieved best accuracy of 69.6%, with HHb achieving the highest accuracy (69.6%), followed by HbT and HbO2. Analysis of frequently selected features revealed a predominance of directed Granger-causality connections, indicating stable and interpretable connectivity patterns associated with pain processing. These findings demonstrate the feasibility of connectivity-based subject-independent pain assessment and highlight the potential of fNIRS for objective clinical pain monitoring.
Open AccessConnectivity-Based Pain Recognition from fNIRS: Parsimonious Subject-Independent Classification
Accurate pain assessment remains challenging, because pain is subjective, and common clinical tools rely on self-report or observation. Functional near-infrared spectroscopy (fNIRS) provides a non-invasive window into cortical haemodynamics and shows promise for objective pain assessment. In this study, we propose a subject-independent framework that models pain states using functional and effective connectivity features derived from fNIRS signals. Using the AI4PAIN dataset (65 participants, 24 channels), we extracted correlation, partial correlation, coherence, and Granger causality matrices from haemodynamic signals (HbO2, HHb, and HbT), yielding a comprehensive connectivity feature space. A three-class classification task (No Pain vs. Low Pain vs. High Pain) was evaluated using leave-one-subject-out (LOSO) cross-validation. Within each training fold, we standardised features and applied mutual-information-based feature selection; a systematic sweep showed that a reduced feature set of 700 connectivity features achieves performance comparable to the full 1380 features and constitutes the minimum configuration at which High Pain instances begin to be detected (High Pain recall ≈ 50%), whereas smaller feature sets produce near-zero High Pain recall. The proposed framework achieved best accuracy of 69.6%, with HHb achieving the highest accuracy (69.6%), followed by HbT and HbO2. Analysis of frequently selected features revealed a predominance of directed Granger-causality connections, indicating stable and interpretable connectivity patterns associated with pain processing. These findings demonstrate the feasibility of connectivity-based subject-independent pain assessment and highlight the potential of fNIRS for objective clinical pain monitoring.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (2) , 1418-1428
Exploring Prefrontal Cortex Involvement in Postural Control Across Degraded Sensory Conditions Using fNIRS and Classification
The prefrontal cortex (PFC) of the brain is involved in processing visual, vestibular, and somatosensory inputs to stabilise postural balance. However, the PFC's activation map for a standing person and different sensory inputs remains unclear. This study aimed to explore the PFC activity map and distinct haemodynamic responses during postural control when sensory inputs change. To this end, functional near-infrared spectroscopy (fNIRS) was employed to capture the haemodynamic responses throughout the PFC from a group of young adults standing in four sensory conditions. The results revealed distinct PFC activation patterns supporting sensory processing, motor planning, and cognitive control to maintain balance under different degraded sensory conditions. Furthermore, by applying machine learning classifiers and multivariate feature selection, the PFC locations and haemodynamic responses indicative of different sensory conditions were identified. The findings of this study offer valuable insights for optimising rehabilitation approaches, enhancing the design of fNIRS studies, and advancing brain-computer interface technologies for balance assessment and training.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (2) , 1418-1428
Exploring Prefrontal Cortex Involvement in Postural Control Across Degraded Sensory Conditions Using fNIRS and Classification
The prefrontal cortex (PFC) of the brain is involved in processing visual, vestibular, and somatosensory inputs to stabilise postural balance. However, the PFC's activation map for a standing person and different sensory inputs remains unclear. This study aimed to explore the PFC activity map and distinct haemodynamic responses during postural control when sensory inputs change. To this end, functional near-infrared spectroscopy (fNIRS) was employed to capture the haemodynamic responses throughout the PFC from a group of young adults standing in four sensory conditions. The results revealed distinct PFC activation patterns supporting sensory processing, motor planning, and cognitive control to maintain balance under different degraded sensory conditions. Furthermore, by applying machine learning classifiers and multivariate feature selection, the PFC locations and haemodynamic responses indicative of different sensory conditions were identified. The findings of this study offer valuable insights for optimising rehabilitation approaches, enhancing the design of fNIRS studies, and advancing brain-computer interface technologies for balance assessment and training.
- Open Access
- 13 October 2025
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 6 (4) , 1-20
Integration of fNIRS and Machine Learning for Identifying Parkinson’s Disease
Parkinson’s disease (PD) is a neurodegenerative disorder where early diagnosis is crucial for effective management. However, current diagnostic methods are often invasive or delayed, hindering early intervention. This study evaluates the effectiveness of combining functional near-infrared spectroscopy (fNIRS) with machine learning to distinguish individuals with PD from age-matched controls. Data were collected using fNIRS from 28 people with PD and 32 age-matched controls while performing the Timed Up and Go (TUG) test under three conditions: simple TUG, cognitive dual-task TUG and motor dual-task TUG. Changes in cerebral blood oxygenation in the prefrontal cortex (PFC) were analysed using four machine learning models: Support Vector Machine (SVM), K-Nearest Neighbours (KNN), Random Forest (RF) and Extreme Gradient Boosting (XGB), along with statistical analyses. Two feature selection models identified key features and channels for differentiating PD from controls. The SVM model achieved the highest accuracy (0.85 \(\pm\) 0.35) in distinguishing PD from CG. Feature selection and statistical analysis showed that dual-task activities were more effective than simple tasks for distinguishing PD from CG. Specific PFC subregions exhibited distinct activation patterns, which could serve as potential biomarkers for PD detection. Combining fNIRS with machine learning shows promise for PD diagnosis, with dual-task activities enhancing accuracy. Further investigation into PFC subregion behaviour could reveal stronger biomarkers.- 13 October 2025
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 6 (4) , 1-20
Open AccessIntegration of fNIRS and Machine Learning for Identifying Parkinson’s Disease
Parkinson’s disease (PD) is a neurodegenerative disorder where early diagnosis is crucial for effective management. However, current diagnostic methods are often invasive or delayed, hindering early intervention. This study evaluates the effectiveness of combining functional near-infrared spectroscopy (fNIRS) with machine learning to distinguish individuals with PD from age-matched controls. Data were collected using fNIRS from 28 people with PD and 32 age-matched controls while performing the Timed Up and Go (TUG) test under three conditions: simple TUG, cognitive dual-task TUG and motor dual-task TUG. Changes in cerebral blood oxygenation in the prefrontal cortex (PFC) were analysed using four machine learning models: Support Vector Machine (SVM), K-Nearest Neighbours (KNN), Random Forest (RF) and Extreme Gradient Boosting (XGB), along with statistical analyses. Two feature selection models identified key features and channels for differentiating PD from controls. The SVM model achieved the highest accuracy (0.85 \(\pm\) 0.35) in distinguishing PD from CG. Feature selection and statistical analysis showed that dual-task activities were more effective than simple tasks for distinguishing PD from CG. Specific PFC subregions exhibited distinct activation patterns, which could serve as potential biomarkers for PD detection. Combining fNIRS with machine learning shows promise for PD diagnosis, with dual-task activities enhancing accuracy. Further investigation into PFC subregion behaviour could reveal stronger biomarkers. - 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (20) , 38217-38229
Integrating IMU Sensors and Dual-Task Timed Up and Go to Identify Biomarkers for Early Stage Parkinson’s Disease Detection
Parkinson’s disease is a progressive neurodegenerative disorder where diagnosis is essential for effective management. However, current diagnostic approaches often lack sensitivity during the early clinical stages of the disease. This study investigates the potential of wearable inertial measurement units combined with machine learning techniques for detecting Parkinson’s disease during mobility tasks. Data were collected from 28 individuals diagnosed with Parkinson’s disease and 34 age-matched healthy controls while performing the Timed Up and Go test and its dual-task variants. A set of gait and mobility features was extracted and refined using two feature selection techniques. Four machine learning models, including Support Vector Machine, Logistic Regression, Linear Discriminant Analysis, and Gradient Boosting, were trained to classify participants. Support Vector Machine and Logistic Regression achieved the highest classification accuracy of 95%. Key discriminative features included turn duration, sit-to-stand time, and stand-to-sit time, which demonstrated potential as objective digital biomarkers for early-stage Parkinson’s disease detection. Additionally, higher motor impairment scores were associated with increased shank range of motion and prolonged turn duration, particularly during dual-task conditions. These findings highlight the potential of wearable sensor-based mobility assessments combined with machine learning as a non-invasive, accessible, and reliable tool for early-stage detection and monitoring of Parkinson’s disease.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (20) , 38217-38229
Integrating IMU Sensors and Dual-Task Timed Up and Go to Identify Biomarkers for Early Stage Parkinson’s Disease Detection
Parkinson’s disease is a progressive neurodegenerative disorder where diagnosis is essential for effective management. However, current diagnostic approaches often lack sensitivity during the early clinical stages of the disease. This study investigates the potential of wearable inertial measurement units combined with machine learning techniques for detecting Parkinson’s disease during mobility tasks. Data were collected from 28 individuals diagnosed with Parkinson’s disease and 34 age-matched healthy controls while performing the Timed Up and Go test and its dual-task variants. A set of gait and mobility features was extracted and refined using two feature selection techniques. Four machine learning models, including Support Vector Machine, Logistic Regression, Linear Discriminant Analysis, and Gradient Boosting, were trained to classify participants. Support Vector Machine and Logistic Regression achieved the highest classification accuracy of 95%. Key discriminative features included turn duration, sit-to-stand time, and stand-to-sit time, which demonstrated potential as objective digital biomarkers for early-stage Parkinson’s disease detection. Additionally, higher motor impairment scores were associated with increased shank range of motion and prolonged turn duration, particularly during dual-task conditions. These findings highlight the potential of wearable sensor-based mobility assessments combined with machine learning as a non-invasive, accessible, and reliable tool for early-stage detection and monitoring of Parkinson’s disease.
- Open Access
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 984-993
Exploring Brain-Body Interactions in Parkinson’s Disease: A Study on Dual-Task Performance
Parkinson’s disease (PD) leads to impairments in cortical structures, resulting in motor and cognitive symptoms. Given the connection between brain structure deficits and physical symptoms in PD, assessing objective brain activity and body motion could provide valuable insights for PD assessment and understanding its underlying mechanisms. This study aimed to explore the connection between brain activity and body movement metrics in a group of individuals with PD and an age-matched healthy control (HC) group. The goal was to evaluate the feasibility of using brain and body motion measures for assessing PD. Participants from both groups underwent the Timed Up and Go (TUG) test under three conditions: simple TUG, cognitive dual-task TUG (CDTUG), and motor dual-task TUG (MDTUG). Key findings include: Both groups exhibited similar activation patterns in the prefrontal cortex (PFC) during the simple TUG, with motor performance differences observed in cadence. During CDTUG, both groups showed the highest PFC activation with more pronounced motor impairments, such as higher stride and step time. During MDTUG, the HC group exhibited significantly higher PFC activity compared to the PD group. While both groups had similar patterns of activation in PFC area while TUG and CDTUG, they showed distinct behaviour during MDTUG. These results suggest that motor and cognitive impairments in PD are more pronounced during complex activities. While MDTUG effectively differentiated between PD and HC groups, the findings indicate that both cognitive and motor dual-tasks are essential for comprehensive PD assessment.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 984-993
Open AccessExploring Brain-Body Interactions in Parkinson’s Disease: A Study on Dual-Task Performance
Parkinson’s disease (PD) leads to impairments in cortical structures, resulting in motor and cognitive symptoms. Given the connection between brain structure deficits and physical symptoms in PD, assessing objective brain activity and body motion could provide valuable insights for PD assessment and understanding its underlying mechanisms. This study aimed to explore the connection between brain activity and body movement metrics in a group of individuals with PD and an age-matched healthy control (HC) group. The goal was to evaluate the feasibility of using brain and body motion measures for assessing PD. Participants from both groups underwent the Timed Up and Go (TUG) test under three conditions: simple TUG, cognitive dual-task TUG (CDTUG), and motor dual-task TUG (MDTUG). Key findings include: Both groups exhibited similar activation patterns in the prefrontal cortex (PFC) during the simple TUG, with motor performance differences observed in cadence. During CDTUG, both groups showed the highest PFC activation with more pronounced motor impairments, such as higher stride and step time. During MDTUG, the HC group exhibited significantly higher PFC activity compared to the PD group. While both groups had similar patterns of activation in PFC area while TUG and CDTUG, they showed distinct behaviour during MDTUG. These results suggest that motor and cognitive impairments in PD are more pronounced during complex activities. While MDTUG effectively differentiated between PD and HC groups, the findings indicate that both cognitive and motor dual-tasks are essential for comprehensive PD assessment.
- Open Access
Assessing Locomotive Syndrome Through Instrumented Five-Time Sit-to-Stand Test and Machine Learning
Locomotive syndrome (LS) refers to a condition where individuals face challenges in performing activities of daily living. Early detection of such deterioration is crucial to reduce the need for nursing care. The Geriatric Locomotive Function Scale (GLFS-25), a 25-question assessment, has been proposed for categorizing individuals into different stages of LS. However, its subjectivity has prompted interest in technology-based quantitative assessments. In this study, we utilized machine learning and an instrumented five-time sit-to-stand test (FTSTS) to assess LS stages. Younger and older participants were recruited, with older individuals classified into LS stages 0–2 based on their GLFS-25 scores. Equipped with a single inertial measurement unit at the pelvis level, participants performed the FTSTS. Using acceleration data, 144 features were extracted, and seven distinct machine learning models were developed using the features. Remarkably, the multilayer perceptron (MLP) model demonstrated superior performance. Following data augmentation and principal component analysis (PCA), the MLP+PCA model achieved an accuracy of 0.9, a precision of 0.92, a recall of 0.9, and an F1 score of 0.91. This underscores the efficacy of the approach for LS assessment. This study lays the foundation for the future development of a remote LS assessment system using commonplace devices like smartphones.
Open AccessAssessing Locomotive Syndrome Through Instrumented Five-Time Sit-to-Stand Test and Machine Learning
Locomotive syndrome (LS) refers to a condition where individuals face challenges in performing activities of daily living. Early detection of such deterioration is crucial to reduce the need for nursing care. The Geriatric Locomotive Function Scale (GLFS-25), a 25-question assessment, has been proposed for categorizing individuals into different stages of LS. However, its subjectivity has prompted interest in technology-based quantitative assessments. In this study, we utilized machine learning and an instrumented five-time sit-to-stand test (FTSTS) to assess LS stages. Younger and older participants were recruited, with older individuals classified into LS stages 0–2 based on their GLFS-25 scores. Equipped with a single inertial measurement unit at the pelvis level, participants performed the FTSTS. Using acceleration data, 144 features were extracted, and seven distinct machine learning models were developed using the features. Remarkably, the multilayer perceptron (MLP) model demonstrated superior performance. Following data augmentation and principal component analysis (PCA), the MLP+PCA model achieved an accuracy of 0.9, a precision of 0.92, a recall of 0.9, and an F1 score of 0.91. This underscores the efficacy of the approach for LS assessment. This study lays the foundation for the future development of a remote LS assessment system using commonplace devices like smartphones.