ABAdam S. Budzikowski

Adam S. Budzikowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adam S. Budzikowski has a total of 160 co-authors. Here are the top co-authors by number of shared publications:

  • Ewa Szczepanska-Sadowska

    Laboratory of Centre for Preclinical Research, Department of Experimental and Clinical Physiology, Medical University of Warsaw, 02-097 Warsaw, Poland

    7 shared publications
  • Ahmad Jallad

    Division of Cardiovascular Medicine-EP section, SUNY Downstate Health Sciences University, Brooklyn, USA, NY

    4 shared publications
  • John Kassotis

    SUNY Downstate

    4 shared publications
  • Asher Gorantla

    Division of Cardiovascular Medicine, SUNY Health Sciences University, Brooklyn, USA, NY

    3 shared publications
  • Frans H. H. Leenen

    Hypertension Unit, University of Ottawa Heart Institute, Ottawa, Ontario K1Y 4W7, Canada

    3 shared publications
  • Piotr Paczwa

    Department of Clinical and Applied Physiology, Warsaw School of Medicine, 00–730 Warsaw, Jazgarzewska 17 str, Poland

    3 shared publications

Latest Publications

  • Open Access

    Vessel Overlay Slows Vision-Language-Model Guidewire Navigation in Simulated Coronary Anatomies

    by Rugved Parmar, Fahim, Adam S. Budzikowski

    Background and Objectives: Vision-language models (VLMs) are proposed as operators for image-guided intervention, but how they use the images they are shown is uncharacterised. We present a coronary guidewire-navigation environment as a controlled instrument, and ask whether rendering the vessel lumen into simulated fluoroscopy helps one such operator.,Methods: The environment renders a fluoroscopic projection each step and executes the operator's JSON action. One VLM navigated from ostium to mid-LAD target in two patient-derived left-coronary anatomies, comparing wire-only and vessel-overlay views over 25 seed-matched episodes per arm. An open-loop policy that only advances, run at the operator arms' own timestep, established what the task requires without visual information. Navigation efficiency was primary, analysed over all episodes without conditioning on success; left-main rotation was secondary.,Results: The open-loop policy reached target in 75/75 and 75/75 episodes, 100.0% of both anatomies, so the task requires no visual information. The VLM reached target in 20/25 episodes viewing wire-only and 13/25 viewing overlay on A1. Overlay slowed navigation in both: win ratio 5.60 (2.43–17.97) and log-rank p = 0.000623 on A1; on A2 it was slower on every seed (Hodges–Lehmann +14.5 steps, p = 1.25e-05). Overlay raised left-main rotation on A1 (p = 0.0147, Holm 0.0147) and induced it on A2.,Conclusions: Because the task is solvable open-loop, the degradation is attributable to how the operator used the image rather than to task difficulty. More visual information made this operator worse. The environment is an instrument for studying VLM visual behaviour, not a navigation benchmark.

  • Open Access

    Exercise-Induced Complete Heart Block and Sinoatrial Exit Block in Baseline Bifascicular Block

    by Asher Gorantla, Peter Cwalina, Aleksander Łuniewski, Ahmad Jallad, Natalia Turkiewicz, Adam S. Budzikowski

    Exercise-Induced Complete Heart Block and Sinoatrial Exit Block in Baseline Bifascicular Block - Article abstract #949566

  • Efficacy of Catheter Ablation in Atrial Fibrillation Patients With Pulmonary Hypertension

    by Md Fahim, Daoud Eldawud, Nana Osei, Godslove Bonnah, Roy Wang, Peter Khouri, Adam S. Budzikowski

    Introduction: Atrial fibrillation (AF) frequently coexists with pulmonary hypertension (PH) and is associated with clinical deterioration, right ventricular dysfunction, and increased mortality. While catheter ablation has demonstrated superiority over anti‐arrhythmic drug (AAD) therapy in select AF populations, outcomes in patients with concurrent PH remain poorly characterized. Methods: We performed a retrospective cohort study using the TriNetX Research Network. Adults with AF and PH were identified and stratified by treatment with catheter ablation plus AAD or AAD therapy alone. After 1:1 propensity score matching for demographics, comorbidities, and medication use, 9759 patients were included in each cohort. The primary outcomes were major adverse cardiovascular events (MACE) and right heart failure. Secondary outcomes included all‐cause mortality, acute myocardial infarction (MI), and stroke. Kaplan–Meier models were used as the primary analysis, with Cox proportional hazards and E ‐value analysis as sensitivity. Competing risk analyses were performed using Fine‐Gray models. Results: Ablation was associated with a 50% reduction in MACE (HR 0.497 [0.467, 0.528], p < 0.001) and 35% reduction in right heart failure (HR 0.647 [0.573, 0.732], p < 0.001). There were also significant reductions in all‐cause mortality (HR 0.469 [0.454, 0.488], p < 0.001) and stroke (HR 0.819 [0.728, 0.922], p = 0.001). There was no difference in acute MI (HR 0.982 [0.891, 1.082], p = 0.710). Findings were consistent across Cox sensitivity analyses, E ‐value analysis, and competing‐risk models. Conclusion: In AF patients with PH, catheter ablation with AAD therapy was associated with substantially lower risks of adverse cardiovascular outcomes compared with AAD therapy alone. These findings suggest that catheter ablation is associated with lower risks of adverse cardiovascular outcomes in this high‐risk population.

  • Open Access

    Syncope Associated With Alternating Fascicular Block in an Elderly Woman: A Case Report

    by Francesca Cali, Goitom Weldearegay, Chris Sani, Asher Gorantla, Adam S. Budzikowski, Francesca M. Cali

    Alternating fascicular block (AFB) is defined by intermittent left anterior fascicular block and left posterior fascicular block on serial electrocardiograms. Although alternating bundle branch block is well recognized as a high‑risk conduction abnormality warranting permanent pacing, evidence and guideline clarity for AFB remain limited. This case describes an 81‑year‑old woman with recurrent syncope. AFB was found on EKG, and a permanent pacemaker was introduced. AFBs are a supporting marker of advanced infra‑Hisian conduction disease and can be associated with syncope and clinically significant bradyarrhythmias. In symptomatic patients, early consideration of permanent pacing is reasonable despite the absence of explicit guideline recommendations. This case highlights key diagnostic features and management considerations while underscoring the need for clearer evidence-based guidance regarding AFB.

  • Open Access

    Prolonged Sinus Arrest Following Traumatic Brain Injury: A Case of Reversible Autonomic Cardiac Dysfunction

    by Krishna Patel, Chris Sani, Asher Gorantla, Varshitha T. Panduranga, Usaid Raqeeb, Adam Budzikowski

    Cardiac disturbances are well-recognized in traumatic brain injury (TBI), but most involve supraventricular arrhythmias or repolarization abnormalities, while sinus arrest is rarely reported. We present a case of a 37-year-old man who developed recurrent, prolonged sinus arrest following severe TBI. He arrived intubated for airway protection after an assault, and imaging demonstrated an acute, depressed, comminuted right temporoparietal skull fracture scattered subarachnoid hemorrhage, and bilateral humeral head fractures with posterior shoulder subluxation. After craniotomy and placement of an external ventricular drain (EVD) for intracranial pressure (ICP) monitoring, the patient experienced multiple spontaneous sinus arrest episodes lasting up to 15 s despite normal metabolic, electrolyte, and toxicology evaluations. A transvenous pacemaker (TVP) was inserted to maintain adequate cardiac output and cerebral perfusion. As ICP improved, the sinus arrests resolved and the TVP was removed. This case highlights a rare neurocardiac manifestation of TBI, demonstrating that elevated ICP can precipitate profound conduction disturbances that may require temporary pacing to manage hemodynamics and prevent secondary brain injury.


  • Open Access

    Coexistence of R-Wave Oversensing and Undersensing in an Implantable Loop Recorder: The Issue of Multiple Sensing in Implantable Loop Recorders

    by Peter Cwalina, Nicolas Rutig, Natalia Turkiewicz, Adam S. Budzikowski

    BACKGROUND Implantable loop recorders (ILRs) are important tools in diagnosing unexplained syncope and palpitations through prolonged rhythm monitoring. However, ILRs can produce false-positive arrhythmia detections, due to signal oversensing and undersensing, which can complicate clinical interpretation. Oversensing typically involves P waves, T waves, or myopotentials; however, simultaneous oversensing and undersensing of multiple waveform components is rare. We report a case of R-wave oversensing of P waves and T waves, with undersensing of QRS complexes, resulting in erroneous atrial fibrillation (AF) alerts. CASE REPORT A 73-year-old woman with hypertension and hyperlipidemia presented with recurrent lightheadedness, palpitations, and hypotension. After an unrevealing initial workup, a Biotronik Biomonitor III ILR was implanted. Within 3 months, the device flagged over 200 episodes of AF and several ventricular fibrillation episodes, despite the patient remaining asymptomatic. Careful signal review revealed a triple-sensing issue of cardiac signals, leading to misclassification of arrhythmias. The sensing filter was reprogrammed from 10 Hz to 24 Hz, resulting in elimination of false-positive detections. Following reprogramming, the patient remained asymptomatic with no further inappropriate arrhythmia alerts and did not require additional interventions. CONCLUSIONS This case highlights a rare example of R-wave oversensing and undersensing by an ILR, emphasizing the importance of individualized device programming to optimize diagnostic accuracy. Additionally, it illustrates that unconventional implantation sites, such as the right parasternal region, can produce unique sensing challenges. Careful review of device signals and appropriate reprogramming can correct oversensing issues, preventing unnecessary interventions and improving patient management.

  • Open Access

    Prolonged Sinus Arrest Following Traumatic Brain Injury: A Case of Reversible Neurocardiac Dysfunction

    by Krishna Patel, Chris Sani, Asher Gorantla, Varshitha Tumkur Panduranga, Usaid Raqeeb, Adam S. Budzikowski

    Neurocardiac dysfunction is a common effect seen in patients with Traumatic Brain Injury (TBI). Commonly these are associated with supraventricular arrhythmias and conduction disturbances. However, sinus arrest has rarely been presented in literature. A 37-year-old male presents after being assaulted including to the head. Upon arrival, the patient was intubated for airway protection. Imaging revealed acute, depressed, and comminuted right temporoparietal skull fracture(Figure 1), bilateral humeral head fractures, and posterior shoulder subluxation. The patient underwent a craniotomy and an External Ventricular Drain (EVD) was placed to monitor the intracranial pressure(ICP). The patient was admitted to the Intensive Care Unit where he was observed to have multiple episodes of sinus arrest lasting up to 15 seconds without having any metabolic or electrolyte abnormalities. A transvenous pacemaker(TVP) was placed to prevent additional episodes of sinus arrests. With improvement of ICP there was a corresponding cessation of these episodes and TVP was removed. TVP in this patient is primarily focused on preventing secondary brain injury by maintaining adequate cerebral perfusion through avoiding hypotension or hypoxia. Use of TVP should be individualized however further research must be done to clarify optimal management in these populations as there is limited literature regarding TBI and sinus arrest.

  • Low-Power Long-Duration Versus High-Power Short-Duration Radiofrequency Ablation of the Atrioventricular Node

    by Sahil Zaveri, Mahmoud Alsaiqali, Howard Do Yu, Rafsan Ahmed, Ahmad Jallad, Adam S. MD Budzikowski

    Background: Atrioventricular node (AVN) radiofrequency (RF) ablation is a highly effective treatment of atrial tachyarrhythmias that are resistant to other management modalities. To date, there is limited research that compares the properties of different RF ablation catheters. The current study aims to compare the effectiveness of several types of RF catheters in AVN ablation. Methods: A total of 66 patients, with a mean age of 73.27 years, underwent AVN RF ablation. The catheters used were categorized as unirrigated (UI), externally irrigated, and contact force sensing with 10 to 20 g of force. Externally-irrigated catheters were divided into 2 different settings: low-power long-duration (LPLD) (30 W, 45°C, and 60 seconds) and high-power short-duration (HPSD) (50 W, 43°C, and 12 seconds). We compared the success rate of the different RF catheters using logistic regression and lesion times using linear regression. Results: The distribution of the types of catheters used is UI in 48%, LPLD in 16%, and HPSD in 36% of patients. All ablation procedures were successful, with no immediate postprocedure complications. HPSD had a significantly shorter lesion time than UI catheters by 403.42 seconds (−631.67 to −175.17). Conclusions: UI catheters, LPLD, and HPSD were equally safe and effective in ablation procedures. The HPSD catheter had a significantly shorter lesion time and, thus, overall decreased procedure time.


  • Open Access

    Sinus Node Dysfunction Triggered by Tonsillar Abscess: Effects of Vagal Nerve Compression

    by Howard Yu, Sahil Zaveri, Michael Schaible, Nabeel Butt, Said Tfaili, Adam S. Budzikowski

    Objective: Unusual clinical course Background: Compression of the vagus nerve by a pharyngeal mass is a well-documented condition that can result in sinus node dysfunction (SND). However, there is scarce literature on extrinsic vagal nerve compression from a tonsillar abscess. Case Report: A 59-year-old woman with a history of asthma and chronic throat discomfort presented to the Emergency Department with bradycardia, palpitations, and voice changes. Following a shellfish allergy hospitalization, an otolaryngology evaluation revealed an enlarged right tonsil, recommending tonsillectomy, but scheduling challenges persisted. The patient reported mild throat pain, dysphagia, hoarseness, rhinorrhea, and exertional dyspnea and was admitted for the evaluation of peritonsillar mass. She was found to be bradycardic with a heart rate of 47, with an electrocardiogram revealing SND. Albuterol and ipratropium nebulizers, as well as dexamethasone and pantoprazole, were initiated. With this treatment, the patient symptomatically improved with a new heart rate of 68. She was discharged with outpatient appointments, but was unfortunately lost to follow-up. Conclusions: This case reveals sinus node dysfunction resulting from extrinsic vagal nerve compression by a tonsillar abscess. Pressure on the vagus nerve can trigger bradycardia and low blood pressure, possibly due to compensatory overfiring of afferent vagal nerve signals from local mass effect. Early recognition and antibiotic treatment are essential to prevent cardiac complications. Clinicians must remain vigilant for such extrinsic causes, particularly in patients with chronic sore throat and cardiac symptoms. Further research and case reports are needed to deepen our understanding of this rare yet significant association.

  • Open Access

    Comparative Effectiveness of Various Radiofrequency Ablation Catheters in the Ablation of Typical Atrial Flutter

    by Asher Gorantla, Mahmoud Alsaiqali, Jonathan Francois, Shruthi Sivakumar, Leonell Freytes-Santiago, Ahmad Jallad, Adam S. Budzikowski

    Introduction Although ablation of typical atrial flutter (AFL) can be easily achieved with radiofrequency energy (RF), no studies compare the effectiveness of different ablation catheters. Our study aimed to compare the efficacy of various types of ablation catheters in treating typical AFL. Methods We analyzed patients with AFL who underwent RF ablation by a single operator at our institution. Successful ablation was evidenced by a bidirectional conduction block (trans-isthmus conduction time ≥ 130 ms or double potentials ≥ 90 ms). Logistic regression was used to compare success rate and linear regression to compare lesion time. Results Out of 222 patients, only six did not meet the success criteria (2.7%). The catheters used were non-irrigated, large-tip, internally irrigated (Chili II Boston Scientific), and externally irrigated (non-force-sensing) catheters (Cool Path, Abbott). An externally irrigated force-sensing catheter (TactiCath, Abbott) was used with > 10 gm of force and (LPLD) setting (30 W− 45 °C− 60 s), and high-power short-duration (HPSD) setting (50 W− 43 °C − 12 s). No complications were encountered. The catheter type had no statistically significant association with ablation success. With the use of externally irrigated catheter with contract force-sensing and HPSD settings, statistically significantly shortening of lesion time was achieved 758.3 s, [CI − 1128.29, − 388.35 s] followed by LPLD by 419.0 s [CI − 808.49, − 29.47 s]. Conclusions The typical atrial flutter radiofrequency ablation procedure had a high success rate, which was not influenced by the type of ablation catheter. Contact force ablation catheter and HPSD are associated with shorter total lesion time.