Quentin Gallas
Research Subjects
Quentin Gallas has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Cecile Ghouila-Houri
University Lille, CNRS, Centrale Lille, ISEN, University Valenciennes, UMR 8520—IEMN, LIA LICS/LEMAC, Lille, France
6 shared publications Alain Merlen
University of Lille, CNRS, Centrale Lille, University Polytechnique Hauts-de-France, UMR 8520, Institut dElectronique de Microélectronique et de Nanotechnologie (IEMN), Lille, France
4 shared publications- Romain Viard
JMH Conception, Pulversheim, France
4 shared publications - Abdelkrim Talbi
University Lille, CNRS, Centrale Lille, ISEN, University Valenciennes, UMR 8520—IEMN, LIA LICS/LEMAC, Lille, France
3 shared publications - Eric Garnier
ONERA
3 shared publications - Philippe Pernod
University Lille, CNRS, Centrale Lille, ISEN, University Valenciennes, UMR 8520—IEMN, LIA LICS/LEMAC, Lille, France
3 shared publications
Latest Publications
- 1 January 2023
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Aircraft
- Vol. 60 (1) , 221-231
Ship Air-Wake Identification from Experimental Data for Automatic Deck Landing and Takeoff
Ship air-wake modeling is a critical task needed to support the design and validation of algorithms that can assist a helicopter’s pilot during shipboard launch and recovery operations. In fact, these operations are often carried out in challenging conditions and impose a significant workload on the pilot. In this framework, the paper presents an air-wake model applicable for flight mechanics analyses and real-time simulations. The definition of the model is based on system identification methodologies applied to wind-tunnel experimental data. The main innovation of the approach consists of the definition of a modular structure of the model that allows setting up a multistep identification strategy and exploiting the most suitable technique for the estimation of each set of the model’s parameters. The validation of the obtained model highlighted a good capability to reproduce the air-wake flowfield in several flow conditions. The model was applied to test trajectory generation and tracking algorithms for helicopter automatic takeoff and landing on a ship deck.
- 1 January 2023
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Aircraft
- Vol. 60 (1) , 221-231
Ship Air-Wake Identification from Experimental Data for Automatic Deck Landing and Takeoff
Ship air-wake modeling is a critical task needed to support the design and validation of algorithms that can assist a helicopter’s pilot during shipboard launch and recovery operations. In fact, these operations are often carried out in challenging conditions and impose a significant workload on the pilot. In this framework, the paper presents an air-wake model applicable for flight mechanics analyses and real-time simulations. The definition of the model is based on system identification methodologies applied to wind-tunnel experimental data. The main innovation of the approach consists of the definition of a modular structure of the model that allows setting up a multistep identification strategy and exploiting the most suitable technique for the estimation of each set of the model’s parameters. The validation of the obtained model highlighted a good capability to reproduce the air-wake flowfield in several flow conditions. The model was applied to test trajectory generation and tracking algorithms for helicopter automatic takeoff and landing on a ship deck.
- 9 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (12) , 11248-11255
High Temperature Gradient Pirani Micro-Sensor Designed and Tested for Aerodynamic Wall Pressure Measurement
This paper presents and discusses the first demonstration of aerodynamic wall pressure measurement using a thermal Pirani effect based micro-sensor. The thermal micro-sensor is designed as a suspended micro-hot-wire separated from the substrate by a nanoscale gap, and mechanically supported by perpendicular micro-bridges. The micro-sensor was calibrated for pressure measurement from 10 kPa to 800 kPa. It was then used as aerodynamic wall pressure sensor in a turbulent boundary layer wind tunnel and successfully measured the 1.1 kPa depression occurring in the wind tunnel when the flow velocity goes up to 40 m/s.
- 9 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (12) , 11248-11255
High Temperature Gradient Pirani Micro-Sensor Designed and Tested for Aerodynamic Wall Pressure Measurement
This paper presents and discusses the first demonstration of aerodynamic wall pressure measurement using a thermal Pirani effect based micro-sensor. The thermal micro-sensor is designed as a suspended micro-hot-wire separated from the substrate by a nanoscale gap, and mechanically supported by perpendicular micro-bridges. The micro-sensor was calibrated for pressure measurement from 10 kPa to 800 kPa. It was then used as aerodynamic wall pressure sensor in a turbulent boundary layer wind tunnel and successfully measured the 1.1 kPa depression occurring in the wind tunnel when the flow velocity goes up to 40 m/s.
- 15 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (8) , 9749-9755
MEMS High Temperature Gradient Sensor for Skin-Friction Measurements in Highly Turbulent Flows
This paper presents and discusses the results obtained with a MEMS (Micro-Electro-Mechanical System) high temperature gradient sensor for time-averaged and fluctuating skin-friction measurements in highly turbulent flows. Designed as a robust wall-mounted suspended hot-wire structure, the micro-sensor was made using conventional microfabrication techniques, compatible with microelectronics for designing integrated smart systems. Successfully implemented into two air wind tunnels, the sensor was tested in a large range of turbulent flows, with mainstream velocities going up to 270 m/s (Mach number of 0.79), which corresponds to the mean velocity of airliner cruise flights. The experiments demonstrated the wide dynamic range of the micro-sensor without reaching its limits. The micro-sensor thereby demonstrated its value for measuring turbulence in aerodynamic applications, being particularly suitable for aeronautics.
- 15 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (8) , 9749-9755
MEMS High Temperature Gradient Sensor for Skin-Friction Measurements in Highly Turbulent Flows
This paper presents and discusses the results obtained with a MEMS (Micro-Electro-Mechanical System) high temperature gradient sensor for time-averaged and fluctuating skin-friction measurements in highly turbulent flows. Designed as a robust wall-mounted suspended hot-wire structure, the micro-sensor was made using conventional microfabrication techniques, compatible with microelectronics for designing integrated smart systems. Successfully implemented into two air wind tunnels, the sensor was tested in a large range of turbulent flows, with mainstream velocities going up to 270 m/s (Mach number of 0.79), which corresponds to the mean velocity of airliner cruise flights. The experiments demonstrated the wide dynamic range of the micro-sensor without reaching its limits. The micro-sensor thereby demonstrated its value for measuring turbulence in aerodynamic applications, being particularly suitable for aeronautics.
- 1 June 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 291, 39-47
High frequency characterization of a sweeping jet actuator
- 1 June 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 291, 39-47
High frequency characterization of a sweeping jet actuator
- Open Access
- 27 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 794
Robust Calorimetric Micro-Sensor for Aerodynamic Applications
This paper reports a calorimetric micro-sensor designed for aerodynamic applications. Measuring both the amplitude and the sign of the wall shear stress at small length-scale and high frequencies, the micro-sensor is particularly suited for flow separation detection and flow control. The micro-sensor was calibrated in static and dynamic in a turbulent boundary layer wind tunnel. Several micro-sensors were embedded in various configurations for measuring the shear stress and detecting flow separation. Specially, one was embedded inside an actuator slot for in situ measurements and twelve, associated with miniaturized electronics, were implemented on a flap model for active flow control experiments.
- 27 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 794
Open AccessRobust Calorimetric Micro-Sensor for Aerodynamic Applications
This paper reports a calorimetric micro-sensor designed for aerodynamic applications. Measuring both the amplitude and the sign of the wall shear stress at small length-scale and high frequencies, the micro-sensor is particularly suited for flow separation detection and flow control. The micro-sensor was calibrated in static and dynamic in a turbulent boundary layer wind tunnel. Several micro-sensors were embedded in various configurations for measuring the shear stress and detecting flow separation. Specially, one was embedded inside an actuator slot for in situ measurements and twelve, associated with miniaturized electronics, were implemented on a flap model for active flow control experiments.
- Open Access
Experimental Measurement Benchmark for Compressible Fluidic Unsteady Jet
A benchmark of different measurement techniques is presented to characterize the dynamic response of a synthetic jet actuator working in compressible regime. The setup involves a piston-based synthetic jet, as well as the benchmarked measurements are hot-wire, cold-wire, Laser Doppler Anemometry, pressure transducer, and Schlieren visualization. Measured flow temperatures range from 20 °C to 150 °C, pressure ranges from 0.5 atm to 4 atm, and velocity are up to 300 m/s. The extreme values of these ranges are reached in an oscillating fashion at a frequency ranging from 30 to 100 Hz. The measurements are pointing out the limitation of cold-wire measurements, due to its high thermic inertia. The results show consistency in the velocity measurements, within 10% in the worst case, between all measurement techniques and the errors are traced back to the calibration ranges, whose sensitivity is also studied.
Open AccessExperimental Measurement Benchmark for Compressible Fluidic Unsteady Jet
A benchmark of different measurement techniques is presented to characterize the dynamic response of a synthetic jet actuator working in compressible regime. The setup involves a piston-based synthetic jet, as well as the benchmarked measurements are hot-wire, cold-wire, Laser Doppler Anemometry, pressure transducer, and Schlieren visualization. Measured flow temperatures range from 20 °C to 150 °C, pressure ranges from 0.5 atm to 4 atm, and velocity are up to 300 m/s. The extreme values of these ranges are reached in an oscillating fashion at a frequency ranging from 30 to 100 Hz. The measurements are pointing out the limitation of cold-wire measurements, due to its high thermic inertia. The results show consistency in the velocity measurements, within 10% in the worst case, between all measurement techniques and the errors are traced back to the calibration ranges, whose sensitivity is also studied.
- 11 September 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (11) , 113502
High temperature gradient nanogap-Pirani micro-sensor with maximum sensitivity around atmospheric pressure
This letter describes and discusses the design and testing of an efficient nanogap Pirani micro-sensor for pressure measurements in a wide range with a maximum sensitivity around atmospheric pressure. The structure combines a substrate-free heated wire and a mechanical support made of silicon oxide micro-bridges allowing both a constant nanoscale gap between the wire and the substrate and a 1 mm long and 3 μm wide wire. The high aspect ratio of the wire provides a uniform heating profile along the wire and contributes to low pressure detection. On the contrary, both the nanoscale gap and the short wire length between two micro-bridges contribute to shift the high limit of the pressure range. When tested between 10 kPa and 800 kPa, the sensor presents a wide measurement range, not fully reached by the experiments, with a maximum of sensitivity close to the atmospheric pressure and performances with up to 38%/dec sensitivity when operating in a constant temperature mode with an overheat of 20 °C.
- 11 September 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (11) , 113502
High temperature gradient nanogap-Pirani micro-sensor with maximum sensitivity around atmospheric pressure
This letter describes and discusses the design and testing of an efficient nanogap Pirani micro-sensor for pressure measurements in a wide range with a maximum sensitivity around atmospheric pressure. The structure combines a substrate-free heated wire and a mechanical support made of silicon oxide micro-bridges allowing both a constant nanoscale gap between the wire and the substrate and a 1 mm long and 3 μm wide wire. The high aspect ratio of the wire provides a uniform heating profile along the wire and contributes to low pressure detection. On the contrary, both the nanoscale gap and the short wire length between two micro-bridges contribute to shift the high limit of the pressure range. When tested between 10 kPa and 800 kPa, the sensor presents a wide measurement range, not fully reached by the experiments, with a maximum of sensitivity close to the atmospheric pressure and performances with up to 38%/dec sensitivity when operating in a constant temperature mode with an overheat of 20 °C.
- Open Access
- 5 September 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 377
Nanogap Pirani Sensor Operating in Constant Temperature Mode for Near Atmospheric Pressure Measurements
This paper presents a high sensitive micro-sensor designed for pressure measurements in a wide range around atmospheric pressure, for application in aerodynamics. The sensor is a temperature-resistance transducer operating with the Pirani effect, which states that below a certain pressure limit, the thermal conductivity of a gas is pressure-dependent. The sensor presents a wide measurement range between 10 kPa and about 800 kPa, in both constant current and constant temperature mode. The last mode enables high-sensitive measurements with a maximum of sensitivity around atmospheric pressure, enabling the use of the sensor for applications in aerodynamics and fluid dynamics, such as active flow control.
- 5 September 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 377
Open AccessNanogap Pirani Sensor Operating in Constant Temperature Mode for Near Atmospheric Pressure Measurements
This paper presents a high sensitive micro-sensor designed for pressure measurements in a wide range around atmospheric pressure, for application in aerodynamics. The sensor is a temperature-resistance transducer operating with the Pirani effect, which states that below a certain pressure limit, the thermal conductivity of a gas is pressure-dependent. The sensor presents a wide measurement range between 10 kPa and about 800 kPa, in both constant current and constant temperature mode. The last mode enables high-sensitive measurements with a maximum of sensitivity around atmospheric pressure, enabling the use of the sensor for applications in aerodynamics and fluid dynamics, such as active flow control.
- Open Access
- 9 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 376
Wall Shear Stress Calorimetric Micro-Sensor Designed for Flow Separation Detection and Active Flow Control
This paper presents an efficient and high-sensitive micro-sensor designed for wall shear stress measurement. The main technical application targeted is flow separation detection for closed-loop active flow control. The sensor is a temperature-resistance transducer operating on heat transfer. The device is micro-structured with three substrate-free wires presenting a high aspect ratio, and periodic perpendicular micro-bridges ensuring mechanical toughness and thermal insulation. This design achieves a homogeneous temperature distribution along the wires. Welded on a flexible printed circuit, the sensor is wall-mounted on a wind tunnel. The experiments, conducted in both attached and separated flow configurations, demonstrate the sensor sensitivity to wall shear stress up to 2.4 Pa and the ability of the 3-wires based design to perform flow direction sensing for back-flow detection.
- 9 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 376
Open AccessWall Shear Stress Calorimetric Micro-Sensor Designed for Flow Separation Detection and Active Flow Control
This paper presents an efficient and high-sensitive micro-sensor designed for wall shear stress measurement. The main technical application targeted is flow separation detection for closed-loop active flow control. The sensor is a temperature-resistance transducer operating on heat transfer. The device is micro-structured with three substrate-free wires presenting a high aspect ratio, and periodic perpendicular micro-bridges ensuring mechanical toughness and thermal insulation. This design achieves a homogeneous temperature distribution along the wires. Welded on a flexible printed circuit, the sensor is wall-mounted on a wind tunnel. The experiments, conducted in both attached and separated flow configurations, demonstrate the sensor sensitivity to wall shear stress up to 2.4 Pa and the ability of the 3-wires based design to perform flow direction sensing for back-flow detection.
- 12 December 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 109 (24) , 241905
High temperature gradient micro-sensor for wall shear stress and flow direction measurements
We present an efficient and high-sensitive thermal micro-sensor for near wall flow parameters measurements. By combining substrate-free wire structure and mechanical support using silicon oxide micro-bridges, the sensor achieves a high temperature gradient, with wires reaching 1 mm long for only 3 μm wide over a 20 μm deep cavity. Elaborated to reach a compromise solution between conventional hot-films and hot-wire sensors, the sensor presents a high sensitivity to the wall shear stress and to the flow direction. The sensor can be mounted flush to the wall for research studies such as turbulence and near wall shear flow analysis, and for technical applications, such as flow control and separation detection. The fabrication process is CMOS-compatible and allows on-chip integration. The present letter describes the sensor elaboration, design, and micro-fabrication, then the electrical and thermal characterizations, and finally the calibration experiments in a turbulent boundary layer wind tunnel.
- 12 December 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 109 (24) , 241905
High temperature gradient micro-sensor for wall shear stress and flow direction measurements
We present an efficient and high-sensitive thermal micro-sensor for near wall flow parameters measurements. By combining substrate-free wire structure and mechanical support using silicon oxide micro-bridges, the sensor achieves a high temperature gradient, with wires reaching 1 mm long for only 3 μm wide over a 20 μm deep cavity. Elaborated to reach a compromise solution between conventional hot-films and hot-wire sensors, the sensor presents a high sensitivity to the wall shear stress and to the flow direction. The sensor can be mounted flush to the wall for research studies such as turbulence and near wall shear flow analysis, and for technical applications, such as flow control and separation detection. The fabrication process is CMOS-compatible and allows on-chip integration. The present letter describes the sensor elaboration, design, and micro-fabrication, then the electrical and thermal characterizations, and finally the calibration experiments in a turbulent boundary layer wind tunnel.