Hans Schellekens
Research Subjects
Research Interests
Hans Schellekens has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Wei Shang
Key Laboratory of Advanced Science and Technology on High Power Microwave, Northwest Institute of Nuclear Technology, Xian, China
2 shared publications Anthony Papillon
1 shared publicationEmmanuel Rigal
1 shared publicationJean-Marc Chaix
1 shared publicationJean-Michel Missiaen
1 shared publicationK. Lenstra
Center for Research on Parallel Computation; Rice University
1 shared publication
Latest Publications
- 1 January 2017
- Published by Elsevier in Materials & Design
- Vol. 113, 353-360
Investigation on the chemical reactions affecting the sinterability and oxide content of Cu–Cr composites during the solid state sintering process
- 1 January 2017
- Published by Elsevier in Materials & Design
- Vol. 113, 353-360
Investigation on the chemical reactions affecting the sinterability and oxide content of Cu–Cr composites during the solid state sintering process
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 45 (10932941) , 465-468
Continuous vacuum monitoring in vacuum circuit breakers
Vacuum presence monitoring is a routine maintenance procedure carried out on vacuum circuit breakers, in which the CB is isolated from the electrical network. The presence of the vacuum is verified by applying a voltage across the open contacts of the vacuum interrupters VI's higher than the breakdown voltage of such contacts in air. This procedure has a 50 years proven record and has found world wide acceptance. Today other methods are proposed to monitor the vacuum presence. These methods can be divided in 3 additional classes discriminated by the pressure range in which they are active. Each class has a clear advantage not shared by the others. Vacuum pressure monitors using high vacuum pressure gauges can give an early warning of an upcoming failure. Monitors using low vacuum pressure gauges detect the dielectric failure caused by vacuum loss as it comes. Monitors using barometric gauges clearly indicate the end of life of the VI. Today only these 3 systems can be used to monitor the pressure in a continuous way. The continuous vacuum monitor significantly decreases the probability to operate a VCB with a leaky VI, hence increasing the availability of the VI on the VCB for the network operator to 99.9999%. The continuous vacuum monitor based on low pressure vacuum gauges is considered an optimal engineering choice as it does not impact the design of the VI.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 45 (10932941) , 465-468
Continuous vacuum monitoring in vacuum circuit breakers
Vacuum presence monitoring is a routine maintenance procedure carried out on vacuum circuit breakers, in which the CB is isolated from the electrical network. The presence of the vacuum is verified by applying a voltage across the open contacts of the vacuum interrupters VI's higher than the breakdown voltage of such contacts in air. This procedure has a 50 years proven record and has found world wide acceptance. Today other methods are proposed to monitor the vacuum presence. These methods can be divided in 3 additional classes discriminated by the pressure range in which they are active. Each class has a clear advantage not shared by the others. Vacuum pressure monitors using high vacuum pressure gauges can give an early warning of an upcoming failure. Monitors using low vacuum pressure gauges detect the dielectric failure caused by vacuum loss as it comes. Monitors using barometric gauges clearly indicate the end of life of the VI. Today only these 3 systems can be used to monitor the pressure in a continuous way. The continuous vacuum monitor significantly decreases the probability to operate a VCB with a leaky VI, hence increasing the availability of the VI on the VCB for the network operator to 99.9999%. The continuous vacuum monitor based on low pressure vacuum gauges is considered an optimal engineering choice as it does not impact the design of the VI.
- 1 May 1994
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2259, 183-186
Interrupting abilities of vacuum interrupters with horseshoe electrode
In this paper, the high current vacuum arc behavior with horse shoe electrode has been described. These are dynamic vacuum arc distribution, the maximum current density related to the interrupting limit and factors which influences the interrupting limits. Then based on the above analyses, several vacuum interrupters within (phi) 70 mm outside diameter have been tested. From the results, it shows that the small size vacuum interrupters can be made with the oblique, ellipse shaped horseshoe electrode. The interrupting ability of such type vacuum interrupters is further increased.
- 1 May 1994
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2259, 183-186
Interrupting abilities of vacuum interrupters with horseshoe electrode
In this paper, the high current vacuum arc behavior with horse shoe electrode has been described. These are dynamic vacuum arc distribution, the maximum current density related to the interrupting limit and factors which influences the interrupting limits. Then based on the above analyses, several vacuum interrupters within (phi) 70 mm outside diameter have been tested. From the results, it shows that the small size vacuum interrupters can be made with the oblique, ellipse shaped horseshoe electrode. The interrupting ability of such type vacuum interrupters is further increased.
- 1 January 1993
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 21 (5) , 469-473
Vacuum interrupter design based on arc magnetic field interaction for horseshoe electrode
Computational methods for evaluating the complex magnetic field structure in axial magnetic field type vacuum interrupters based on horseshoe electrode geometry are demonstrated. Arcing behavior can only be understood by incorporating an arcing model. An essentially low-current arcing model is capable of predicting the high-current arcing behavior and can be used to optimize the contact structure.
- 1 January 1993
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 21 (5) , 469-473
Vacuum interrupter design based on arc magnetic field interaction for horseshoe electrode
Computational methods for evaluating the complex magnetic field structure in axial magnetic field type vacuum interrupters based on horseshoe electrode geometry are demonstrated. Arcing behavior can only be understood by incorporating an arcing model. An essentially low-current arcing model is capable of predicting the high-current arcing behavior and can be used to optimize the contact structure.