Maamoun Abdul Fattah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maamoun Abdul Fattah has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Asim Ali
Department of Ophthalmology and Vision Sciences, The Hospital for Sick Children, Toronto, Canada
2 shared publications - Carl-Joe Mehanna
Centre Hospitalier Intercommunal de Créteil
2 shared publications - Hani Tamim
Department of Internal Medicine, Clinical Research Institute, American University of Beirut Medical Center
2 shared publications - Haytham I. Salti
Department of Ophthalmology, American University of Beirut Medical Center, Beirut, Lebanon
2 shared publications Jaafar El-Annan
Department of Ophthalmology, University of Texas Medical Branch, Galveston, TX, USA
2 shared publicationsJyh Haur Woo
Department of Ophthalmology and Vision Sciences, The Hospital for Sick Children, Toronto, ON, Canada
2 shared publications
Latest Publications
- 9 January 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (12) , e33
Letter Regarding: Commentary on “Keratoconus Detection in High-Astigmatism Pediatric Patients: Optimal Pentacam Indices and Cutoff Points”
- 9 January 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (12) , e33
Letter Regarding: Commentary on “Keratoconus Detection in High-Astigmatism Pediatric Patients: Optimal Pentacam Indices and Cutoff Points”
- 30 October 2023
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 27 (6) , 328.e1-328.e7
Children with high astigmatism: tomographic and refractive characteristics and the ability of current indices to rule out keratoconus
- 30 October 2023
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 27 (6) , 328.e1-328.e7
Children with high astigmatism: tomographic and refractive characteristics and the ability of current indices to rule out keratoconus
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 716-723
Long-term results of hyperopic ablations using alcohol-assisted PRK and FS-LASIK: comparative study
Purpose: To evaluate the long-term visual and refractive outcomes of hyperopic excimer ablation using alcohol-assisted photorefractive keratectomy (PRK) and femtosecond laser–assisted laser in situ keratomileusis (FS-LASIK). Setting: American University of Beirut Medical Center, Beirut, Lebanon. Design: Retrospective, matched comparative study. Methods: Eyes that underwent alcohol-assisted PRK were compared to matched eyes that underwent FS-LASIK. All patients were followed up for at least 3 years after surgery. The refractive and visual outcomes of each group were compared at different postoperative time points. The main outcome measures were spherical equivalent deviation from target (SEDT), manifest refraction, and visual acuity. Results: 83 eyes underwent alcohol-assisted PRK and 83 matched eyes underwent FS-LASIK. Preoperative manifest refraction spherical equivalent was 2.44 ± 1.18 diopters (D) and 2.20 ± 0.87 D (P = .133) in the PRK and FS-LASIK groups, respectively. Preoperative manifest cylinder was −0.77 ± 0.89 D and −0.61 ± 0.59 D (P = .175) for the PRK and LASIK groups, respectively. 3 years postoperatively, SEDT was 0.28 ± 0.66 D and 0.40 ± 0.56 D for the PRK and LASIK groups, respectively (P = .222), whereas manifest cylinder was −0.55 ± 0.49 D and −0.30 ± 0.34 D for PRK and LASIK, respectively (P < .001). The mean difference vector was 0.59 ± 0.46 for PRK and 0.38 ± 0.32 for LASIK (P < .001). 13.3% of PRK eyes and 0% of LASIK eyes had >1 D of manifest cylinder (P = .003). Conclusions: Both alcohol-assisted PRK and FS-LASIK are safe and effective for the treatment of hyperopia. PRK induces slightly more postoperative astigmatism than LASIK. Larger optical zones and recently introduced ablation profiles that lead to a smoother ablation surface might improve the clinical results of hyperopic PRK.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 716-723
Long-term results of hyperopic ablations using alcohol-assisted PRK and FS-LASIK: comparative study
Purpose: To evaluate the long-term visual and refractive outcomes of hyperopic excimer ablation using alcohol-assisted photorefractive keratectomy (PRK) and femtosecond laser–assisted laser in situ keratomileusis (FS-LASIK). Setting: American University of Beirut Medical Center, Beirut, Lebanon. Design: Retrospective, matched comparative study. Methods: Eyes that underwent alcohol-assisted PRK were compared to matched eyes that underwent FS-LASIK. All patients were followed up for at least 3 years after surgery. The refractive and visual outcomes of each group were compared at different postoperative time points. The main outcome measures were spherical equivalent deviation from target (SEDT), manifest refraction, and visual acuity. Results: 83 eyes underwent alcohol-assisted PRK and 83 matched eyes underwent FS-LASIK. Preoperative manifest refraction spherical equivalent was 2.44 ± 1.18 diopters (D) and 2.20 ± 0.87 D (P = .133) in the PRK and FS-LASIK groups, respectively. Preoperative manifest cylinder was −0.77 ± 0.89 D and −0.61 ± 0.59 D (P = .175) for the PRK and LASIK groups, respectively. 3 years postoperatively, SEDT was 0.28 ± 0.66 D and 0.40 ± 0.56 D for the PRK and LASIK groups, respectively (P = .222), whereas manifest cylinder was −0.55 ± 0.49 D and −0.30 ± 0.34 D for PRK and LASIK, respectively (P < .001). The mean difference vector was 0.59 ± 0.46 for PRK and 0.38 ± 0.32 for LASIK (P < .001). 13.3% of PRK eyes and 0% of LASIK eyes had >1 D of manifest cylinder (P = .003). Conclusions: Both alcohol-assisted PRK and FS-LASIK are safe and effective for the treatment of hyperopia. PRK induces slightly more postoperative astigmatism than LASIK. Larger optical zones and recently introduced ablation profiles that lead to a smoother ablation surface might improve the clinical results of hyperopic PRK.
- Open Access
- 22 July 2018
- Published by Wiley in Journal of Ophthalmology
- Vol. 2018, 1
Corrigendum to “Five-Year Incidence and Progression of Diabetic Retinopathy in Patients with Type II Diabetes in a Tertiary Care Center in Lebanon”
[This corrects the article DOI: 10.1155/2017/9805145.].
- 22 July 2018
- Published by Wiley in Journal of Ophthalmology
- Vol. 2018, 1
Open AccessCorrigendum to “Five-Year Incidence and Progression of Diabetic Retinopathy in Patients with Type II Diabetes in a Tertiary Care Center in Lebanon”
[This corrects the article DOI: 10.1155/2017/9805145.].
- Open Access
- 31 May 2017
- Published by Wiley in Journal of Ophthalmology
- Vol. 2017, 1-7
Five-Year Incidence and Progression of Diabetic Retinopathy in Patients with Type II Diabetes in a Tertiary Care Center in Lebanon
Objective. To estimate the 5-year incidence of progression rate and regression rate and risk factors for diabetic retinopathy (DR) in a cohort of Lebanese patients with type II diabetes. Methods. We followed a cohort of 462 Lebanese patients with type II diabetes for over 5 years at the American University of Beirut Medical Center. Patients underwent yearly complete ophthalmic evaluation and fundus photographs and were assessed for the incidence, stage, and evolution of DR using modified Airlie House classification. Results. Among the 462 patients, 281 had no DR at baseline. The 5-year cumulative incidence of any DR was 10% (95% CI: 6–13), and only baseline microalbuminuria correlated with the development of DR (, 95% CI: 4.39–25.23, ). Among the 181 patients with baseline DR, the worsening and regression rates of DR were 31.5% (95% CI: 25–38) and 9% (95% CI: 5–13), respectively. Microalbuminuria also approached statistical significance as a risk factor for DR worsening (, 95% CI: 0.97–3.70, ). Conclusion. The 5-year incidence of DR in this hospital-based cohort is relatively low. Microalbuminuria was independently associated with the incidence and progression of the disease. We recommend to screen patients with type II diabetes for microalbuminuria as prognostic for the development and worsening of DR.- 31 May 2017
- Published by Wiley in Journal of Ophthalmology
- Vol. 2017, 1-7
Open AccessFive-Year Incidence and Progression of Diabetic Retinopathy in Patients with Type II Diabetes in a Tertiary Care Center in Lebanon
Objective. To estimate the 5-year incidence of progression rate and regression rate and risk factors for diabetic retinopathy (DR) in a cohort of Lebanese patients with type II diabetes. Methods. We followed a cohort of 462 Lebanese patients with type II diabetes for over 5 years at the American University of Beirut Medical Center. Patients underwent yearly complete ophthalmic evaluation and fundus photographs and were assessed for the incidence, stage, and evolution of DR using modified Airlie House classification. Results. Among the 462 patients, 281 had no DR at baseline. The 5-year cumulative incidence of any DR was 10% (95% CI: 6–13), and only baseline microalbuminuria correlated with the development of DR (, 95% CI: 4.39–25.23, ). Among the 181 patients with baseline DR, the worsening and regression rates of DR were 31.5% (95% CI: 25–38) and 9% (95% CI: 5–13), respectively. Microalbuminuria also approached statistical significance as a risk factor for DR worsening (, 95% CI: 0.97–3.70, ). Conclusion. The 5-year incidence of DR in this hospital-based cohort is relatively low. Microalbuminuria was independently associated with the incidence and progression of the disease. We recommend to screen patients with type II diabetes for microalbuminuria as prognostic for the development and worsening of DR.