JMJonathan M. Morris

Jonathan M. Morris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jonathan M. Morris has a total of 481 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ablative Techniques for the Management of Osseous Spine Metastases: A Narrative Review

    by Zach Pennington, Jonathan M. Morris, Aladine Elsamadicy, Sheng-Fu Larry Lo, Joseph H. Schwab, Daniel M. Sciubba

    With continued improvements in systemic cancer therapies, there has been an increase in the survivorship of patients with spinal metastases. However, many patients with spinal metastases are frail and may not be able to tolerate the morbidity of open surgery. For these patients, percutaneous ablation techniques offer a minimally invasive approach that can facilitate local tumor control and pain relief. Here we describe the currently employed modalities—radiofrequency ablation (RFA), microwave ablation (MWA), cryoablation, and laser interstitial thermal therapy (LITT)—summarize the clinical support for their use, and overview the relative risks and benefits for each. All these technologies offer to help improve local tumor control and improve oncologic pain associated with vertebral metastases, and they have become a staple of multidisciplinary spine metastasis care at many centers. As clinical experience with these technologies continues to grow, their use will likely become more widely adopted, and so understanding of their indications, risks, and benefits will become increasingly important to the practicing spine oncologist.


  • Open Access

    Automated Volumetric Assessment of Hounsfield Units Using a Deep-Reasoning and Learning Model: Correlations with DXA Metrics

    by Hans K. Nugraha, Vaida Goplin, Linjun Yang, Jonathan M. Morris, Paul M. Huddleston, Mimi C. Sammarco, A. Noelle Larson

    Background/Objectives: Accurate assessment of spinal bone density is essential for evaluating bone health, particularly in preoperative planning. Conventional manual methods for Hounsfield unit (HU) measurements rely on single-slice measurements within the region of interest, limiting their precision and reproducibility in patients with severe vertebral deformities. We hypothesize that a novel deep-reasoning and learning model (DR-AI) can fully automate spinal bone density assessment volumetrically, with high correlations to spinal bone mineral density (BMD) obtained from dual-energy X-ray absorptiometry (DXA), as well as to the T- and Z-scores. Methods: A cross-sectional study was conducted on patients who had BMD assessment of their lumbar spine and lumbar CT scans within 1 year. The fully-automated DR model was utilized to analyze the soft-tissue window of the lumbar vertebrae CT scans. Spearman correlation coefficients were calculated to assess the strength of relationships between the computed volumetric HUs and the BMD, T-, and Z-scores from each vertebra. Results: 84 patients (67 females, mean age 74.1 ± 10.3 years; 17 males, mean age 68.1 ± 12.4 years) meeting inclusion criteria. Correlation analyses for L1 to L4 showed significant positive relationships (p < 0.0001), with the strongest correlation at L2 between HU and BMD (ρ = 0.75). Conclusions: the DR model for automated assessment of volumetric HUs offers a highly reliable, efficient, and precise alternative to DXA measurements.


  • Open Access

    Point-of-Care Virtual Planning and 3D Printing in Facial Trauma: A 10-Year Experience at a Single Institution

    by Sara M. Hussein, Doga Kuruoglu, Jonathan M. Morris, Victoria A. Sears, Abdallah A. Shehab, Waleed Gibreel, Basel A. Sharaf

    Background: Despite increased adoption of virtual surgical planning (VSP) in various craniofacial indications, the incorporation of VSP/3DP into facial trauma care remains limited. Therefore, Expedited Preoperative Point of Care for Fracture Reduction to Normalized Anatomy and 3DP to Improve Surgical Outcomes (EPPOCRATIS) was introduced in 2021. This study evaluates our experience with EPPORATIS in craniomaxillofacial trauma over 10 years. Methods: A retrospective review of patients who underwent facial trauma repair between September 2014 and September 2024 was conducted. For each VSP/3DP case, a patient with similar facial trauma patterns, who was treated without VSP, was selected. Evaluation metrics included operative time, blood loss, length of stay, complication rates, and fracture reduction accuracy through 3D heatmap analyses. Operative metrics were normalized by implant (i.e., fracture plates and screws) count to account for fracture complexity. A value of p < 0.05 was deemed statistically significant. Results: The VSP group presented with more complex injuries and higher involvement of various surgical specialties (p < 0.5) and demonstrated longer operative times (p < 0.03). Although the difference was not statistically significant (p = 0.4), when adjusted for implant count, the VSP group had shorter operative times (median: 15.4 vs. 19.3 min/implant) and reduced blood loss compared to non-VSP cases (median: 3.4 mL/implant vs. 4.2 mL/implant). Complications, revision rates, and length of stay showed no significant differences. Conclusions: The use of VSP/3DP (EPPOCRATIS) in craniomaxillofacial trauma reconstruction demonstrated operative efficiency and accurate fracture reduction in complex cases. Further studies are needed to examine the feasibility and cost-effectiveness of point-of-care VSP/3DP in trauma centers.


  • Demographics, Utilization, Workflow, and Outcomes Based on Observational Data From the RSNA-ACR 3D Printing Registry

    by Kenneth C. Wang, Justin R. Ryan, Leonid Chepelev, Nicole Wake, Edward P. Quigley, Lumarie Santiago, Adam Wentworth, Amy Alexander, Jonathan M. Morris, Dominik Fleischmann, et al.


  • Open Access

    Correction to: Safety and histopathologic yield of percutaneous CT‑guided biopsies of the skull base, orbit, and calvarium

    by Theodore Betting, John C. Benson, Ajay Madhavan, Darya Shlapak, Padraig Morris, Jonathan Morris, Felix Diehn, Jared Verdoorn, Greta Liebo, Carrie Carr


  • Case Examples of Advanced 3D Printing in Hospitals and Medical Centers

    by Rajul Gupta, Victoria A. Sears, Daniel L. Price, Kyle S. Ettinger, Frank J. Rybicki, Jonathan M. Morris

  • Safety and histopathologic yield of percutaneous CT-guided biopsies of the skull base, orbit, and calvarium

    by Theodore Betting, John C. Benson, Ajay Madhavan, Darya Shlapak, Padraig Morris, Jonathan Morris, Felix Diehn, Jared Verdoorn, Greta Liebo, Carrie Carr

    Purpose Although CT-guided biopsies of the calvarium, skull base, and orbit are commonly performed, the best approaches, efficacy, and safety of such procedures remain scantly described in the literature. This retrospective review of percutaneous biopsies illustrates several approaches to challenging biopsy targets and provides a review of procedural planning considerations and histopathologic yield. Methods A retrospective review of CT-guided biopsies of the skull base, calvarium, and orbit between 1/1/2010 and 10/30/2020 was conducted. Patient demographics and procedural factors were recorded, including lesion size and location, biopsy approach, and needle gauge. Outcomes were also noted, including CT dose length product, complications, and histopathologic yield. Results Sixty-one CT-guided biopsies were included in the final analysis: 34 skull base, 23 calvarial, and 4 orbital lesions. The initial diagnostic yield was 32/34 (94%) for skull base lesions, with one false-negative and one non-diagnostic sample. Twenty-one of twenty-three (91%) biopsies in the calvarium were initially diagnostic, with one false-negative and one non-diagnostic sample. In the orbit, 4/4 biopsies were diagnostic. The total complication rate for the cohort was 4/61 (6.6%). Three complications were reported in skull base procedures (2 immediate and 1 delayed). A single complication was reported in a calvarial biopsy, and no complications were reported in orbital biopsies. Conclusion Percutaneous CT-guided core needle biopsies can be performed safely and with a high diagnostic yield for lesions in the skull base, calvarium, and orbit.


  • Open Access

    Resection of a Solitary Right Ventricular Metastasis in Oligorecurrent Hepatocellular Carcinoma

    by Defne Gunes Ergi, Kyle W. Klarich, Joseph A. Dearani, Juan A. Crestanello, Joseph J. Maleszewski, Jonathan M. Morris, Phillip M. Young, Cameron M. Callaghan, Henry C. Pitot, Arman Arghami

    Hepatocellular carcinoma (HCC), constituting the predominant manifestation of liver cancer, stands as a formidable medical challenge. The prognosis subsequent to surgical intervention, particularly for individuals presenting with a solitary tumor, relies heavily on the degree of invasiveness. The decision-making process surrounding therapeutic modalities in such cases assumes paramount importance. This case report illuminates a rather unusual clinical scenario. Here, we encounter a patient who, following a disease-free interval, manifested an atypical presentation of HCC, specifically, a solitary cardiac metastasis. The temporal interval of remission adds an additional layer of complexity to the case. Through a multidisciplinary planning process, the decision was made for surgical removal of the metastatic tumor.


  • Projection of realistic three‐dimensional photogrammetry models using stereoscopic display: A technical note

    by André de Sá Braga Oliveira, Luciano César P. C. Leonel, Edward R. LaHood, Bachtri T. Nguyen, Anahid Ehtemami, Stephen P. Graepel, Michael J. Link, Carlos D. Pinheiro‐Neto, Nirusha Lachman, Jonathan M. Morris, et al.

    The 3D stereoscopic technique consists in providing the illusional perception of depth of a given object using two different images mimicking how the right and left eyes capture the object. Both images are slightly different and when overlapped gives a three‐dimensional (3D) experience. Considering the limitations for establishing surgical laboratories and dissections courses in some educational institutions, techniques such as stereoscopy and photogrammetry seem to play an important role in neuroanatomy and neurosurgical education. The aim of this study was to describe how to combine and set up realistic models acquired with photogrammetry scans in 3D stereoscopic projections. Three donors, one dry skull, embalmed brain and head, were scanned using photogrammetry. The software used for displaying the final realistic 3D models (Blender, Amsterdam, the Netherlands) is a free software and allows stereoscopic projection without compromising the interactivity of each model. By default, the model was exported and immediately displayed as a red cyan 3D mode. The 3D projector used in the manuscript required a side‐by‐side 3D mode which was set up with simple commands on the software. The final stereoscopy projection offered depth perception and a visualization in 360° of each donor; this perception was noted especially when visualizing donors with different cavities and fossae. The combination of 3D techniques is of paramount importance for neuroanatomy education. Stereoscopic projections could provide a valuable tool for neuroanatomy instruction directed at clinical trainees and could be especially useful when access to laboratory‐based learning is limited.


  • The Role of 3D Printing in Treatment Planning of Spine and Sacral Tumors

    by Jonathan M. Morris, Adam Wentworth, Matthew T. Houdek, S. Mohammed Karim, Michelle J. Clarke, David J. Daniels, Peter S. Rose