ESEthungshan Shitiri

Ethungshan Shitiri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ethungshan Shitiri has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Whole-Blood Boundary Analysis of BioFET-Based ctDNA Detection for Intravascular Sensing in Intrabody Nanonetworks

    by Ida Kleger-Rudomin, Filip Lemic, Sergi Abadal, Eduard Alarcon, Ethungshan Shitiri

  • Open Access

    Set Transformer Architectures and Synthetic Data Generation for Flow-Guided Nanoscale Localization

    by Mika Leo Hube, Filip Lemic, Ethungshan Shitiri, Gerard Calvo Bartra, Sergi Abadal, Xavier Costa Pérez


  • Open Access

    Work-in-Progress: Intra-Body Nanonetworks for In Vivo Biomarker Detection in Capillaries

    by Ethungshan Shitiri, Eneko Ibarluzea Sòria, Satvika Santhoshi Marakala, Filip Lemic, Sergi Abadal, Eduard Alarcón

    Advancements in medical diagnostics are crucial for early disease detection and effective treatment. One of the most advanced diagnostic methods is liquid biopsy (LB). It involves analyzing bodily fluids such as blood or saliva samples to identify disease biomarkers (BMs), including proteins, DNA/RNA fragments, and other organic chemicals produced by abnormal cells [3]. Compared to traditional tissue biopsies, LB is less invasive and provides shorter turnaround delays-the time it takes to get laboratory results from the bodily fluid samples. However, current LB methods face significant challenges. They rely on ex vivo processes that involve handling and analyzing samples outside the body, resulting in a turnaround delay of around seven days. Additionally, they can access only a tiny fraction of available BMs, limiting their efficacy in early-stage disease detection when BM concentrations are exceedingly low. For example, only 0.3% of total circulating tumor DNA (ctDNA) is found in a 15 ml blood sample [2].


  • Open Access

    Enhanced Drug Delivery via Localization-Enabled Relaying in Molecular Communication Nanonetworks

    by Ethungshan Shitiri, Akarsh Yadav, Sergi Abadal, Eduard Alarcón, Ho-Shin Cho

    Intra-body nanonetworks hold promise for advancing targeted drug delivery (TDD) systems through molecular communications (MC). In the baseline MC-TDD system, drug-loaded nanomachines (DgNs) are positioned near the infected tissues to deliver drug molecules directly. To mitigate the decline in drug delivery efficiency caused by diffusion, we propose an enhanced MC-TDD system with a relay network. This network employs a novel localization-enabled relaying mechanism, where a nano-controller broadcasts a localization signal. DgNs then measure the received signal strength against thresholds to determine their clusters relative to the infected tissue. Additionally, our study considers the effect of multiple absorbing DgNs on the channel impulse response (CIR), a factor overlooked in previous works. Our approach improves drug delivery efficiency by 17% compared to the baseline system. Importantly, we find that optimizing CIR is crucial for enhancing drug delivery efficiency. These findings pave the way for further research into optimizing CIR-based relay selection, as well as investigating the impact of factors such as drug molecule lifespan, obstruction probabilities, and flow dynamics.


  • Non-Data-Aided SNR Estimation for Molecular Communication Systems in the Internet of Bio-Nano Things

    by Akarsh Yadav, Ajit Kumar, Ethungshan Shitiri, Sudhir Kumar, Ho-Shin Cho

    This paper proposes a non-data-aided (NDA) signal-to-noise ratio (SNR) estimation method for molecular diffusive communication channels. In contrast to previous data-aided (DA) approaches, which require a known data sequence to be shared between transmitter and receiver nanomachines, the proposed NDA method eliminates the need for prior knowledge of data symbols for the estimation process. The absence of a training sequence significantly reduces resource costs by minimizing the number of molecules required for information transmission. The expectation-maximization (EM) algorithm was used to iteratively find the maximum-likelihood (ML) estimates. The proposed method is particularly advantageous in scenarios in which accessing known data sequences is not possible, thereby ensuring robust communication in the Internet of bio-nano things. By employing the ML estimates obtained through the EM algorithm, the probabilities associated with the transmission of data symbols were derived, and the bit error probabilities were obtained to assess the system performance. The numerical results validated the effectiveness of the proposed NDA SNR estimator in accurately estimating SNR over a diverse range of conditions. The proposed NDA estimator demonstrated resilience by maintaining a low bit error probability.


  • Open Access

    Reinforcement Learning-Based Power Control for MACA-Based Underwater MAC Protocol

    by Faisal Ahmed, Junho Cho, Ethungshan Shitiri, Ho-Shin Cho

    A major amount of the energy of battery-powered sensors is spent during packet transmissions. This issue has led to the development of power-control-based multiple-access collision avoidance (MACA) protocols that can reduce the packet transmission power and conserve energy. However, the reduction in transmission power renders the packets susceptible to collisions. To reduce these collisions while maintaining high energy efficiency, we propose a power control protocol that utilizes reinforcement learning to choose the optimal transmission power. The total reward is determined by the occurrence of a collision, amount of transmission power used, frequency of DATA packet retransmissions, and update of the interference range. A key feature of the proposed protocol is that it enables sensors to prevent collisions without any prior knowledge of interferences, thus eliminating the need for additional signaling. Further, simulation results reveal that compared with benchmark protocols such as collision avoidance power control media access control (MAC), two-level power control MAC, and MACA-based power control MAC protocols, the proposed protocol improves network throughput while minimizing the network energy consumption and collisions per packet. The efficacy of the proposed protocol is demonstrated through results obtained using varying average traffic loads.


  • Open Access

    In-Body Sequential Multidrug Delivery Scheme Using Molecular Communication

    by Tania Islam, Ethungshan Shitiri, Ho-Shin Cho

    This study explores the application of molecular communication (MC) for the enhancement of the performance of sequential drug delivery in combination therapy—a multi-drug treatment procedure. To achieve high efficacy, it is essential to maintain a delivery time interval (DTI) between consecutive drug administrations. To this end, this study proposes a coordination scheme that enables the control of the release times of a network of drug-carrying nanomachines to ensure the maintenance of the DTI. Particularly, MC is employed to develop a centralized network, wherein the release times of the drugs from the drug-carrying nanomachines are managed by a controller nanomachine. This nanomachine is named the internal controller nanomachine, as it is placed within the human body. The performance of the proposed scheme is evaluated in terms of the DTI error. Furthermore, the analytical expression of the error is derived and its correctness is validated using simulations.


  • Open Access

    Probability Distribution of a Signal’s Peak Time in a Molecular Diffusive Media

    by Ethungshan Shitiri, H. Birkan Yilmaz, Ho-Shin Cho

    The peak time of a received signal in a molecular channel is random and generally assumed to follow the Normal distribution. However, the untested validity of the assumption motivates this letter. Considering an absorbing receiver placed in a free-diffusion molecular communication via diffusion (MCvD) system, we analyze the randomness in terms of the distribution of the peak time using simulated data and define one of the parameters. In addition, we derive the semi-analytical expressions of the distribution by using Poisson and Normal approximations of the absorbed molecules. Through numerical analysis, we evaluate the accuracy of the models and demonstrate that the Poisson model achieves a better fit. The key finding is that the distribution has extreme values resulting in a heavy right-tail and this information can be a useful tool to develop improved channel models.


  • Open Access

    A Molecular Communication-Based Simultaneous Targeted-Drug Delivery Scheme

    by Tania Islam, Ethungshan Shitiri, Ho-Shin Cho

    This paper considers simultaneous drug-delivery (SDD) in molecular communication-based (MC-based) targeted drug-delivery systems. In a realistic scenario, the drug-carrying nanomachines are randomly placed close to the infected site. Due to the random propagation delays in the MC channel, the drugs from multiple drug-carrying nanomachines may, therefore, not arrive simultaneously at the infected site, leading to low efficacy and resulting in drug-delivery-time errors. To overcome this error and to administer the drugs simultaneously at the infected site, we use an internal controller nanomachine to control the release times of the drug-carrying nanomachines, with consideration of the propagation delay, to achieve SDD. In this regard, we propose two SDD schemes, namely, the direct trigger estimate SDD (DTE-SDD) scheme and the indirect trigger estimate SDD (iDTE-SDD) scheme. The difference between these schemes is that in the iDTE-SDD scheme, to estimate the propagation delay, the internal controller nanomachine depends on the drug-carrying nanomachines, while in the DTE-SDD scheme, it does not. Furthermore, to study the errors theoretically, we derive the analytical model of delivery-time error, and this is validated with simulation results. We perform intensive evaluations to understand the system's behavior under different channel conditions, such as the number of molecules released and the distance. The simulation results highlight the proposed scheme's energy efficiency and robustness to the large propagation delay, reducing the delivery-time error to improve the accuracy of the SDD.