Xin Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xin Gao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Lin Hu
College of Physics, Guizhou University, Guiyang 550025, China
6 shared publicationsGang Sun
Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
5 shared publicationsQiang Wang
Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
5 shared publicationsChenxi Li
Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
4 shared publicationsNingyu Liu
3 shared publicationsYikai Ma
College of Physics Guizhou University Guiyang China
3 shared publications
Latest Publications
- 1 March 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 200, 113907
A direct method for detecting proteins in body fluids by Surface-Enhanced Raman Spectroscopy under native conditions
- 1 March 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 200, 113907
A direct method for detecting proteins in body fluids by Surface-Enhanced Raman Spectroscopy under native conditions
- Open Access
- 19 October 2021
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 126 (20)
Study on Dominant Parameters Determining Streamer Initiation From Hydrometeors in Thundercloud Fields
This study reports a study trying to find the dominant factor on streamer initiation from an isolated hydrometeor in thundercloud fields at 7 km altitude corresponding to an atmosphere pressure of about 0.453 atm. Three parameters are considered including hydrometeor size, shape, and electric quantity. The simulation results indicate that a larger hydrometeor is more likely to initiate a streamer discharge at a lower ambient field for noncharged hydrometeors. The charge on hydrometeor plays a prominent role when a charged hydrometeor has a smaller size, and it is easier to initiate a streamer in this case. At 0.25 Ek, a positive streamer discharge has been presented for a charged hydrometeor with a radius of 0.5 mm. The critical field to form streamer discharge for a column shape hydrometeor without charge is much smaller than that for a spherical hydrometeor. If smaller hydrometeors are charged, the critical field for a spherical hydrometeor becomes lower than that for a column one. The electric quantity charged on hydrometeor has little effect on the critical field for both spherical and column hydrometeors, when the hydrometeor size is larger enough. The charge on hydrometeor plays a dominant role in streamer initiation when hydrometeor is smaller, but hydrometeor shape becomes more important for larger hydrometeor. Streamer discharge can be predicted by Meek number, but stable streamer cannot be ensured. Streamer branch will be met when ambient field is lower than 0.25 Ek.
- 19 October 2021
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 126 (20)
Open AccessStudy on Dominant Parameters Determining Streamer Initiation From Hydrometeors in Thundercloud Fields
This study reports a study trying to find the dominant factor on streamer initiation from an isolated hydrometeor in thundercloud fields at 7 km altitude corresponding to an atmosphere pressure of about 0.453 atm. Three parameters are considered including hydrometeor size, shape, and electric quantity. The simulation results indicate that a larger hydrometeor is more likely to initiate a streamer discharge at a lower ambient field for noncharged hydrometeors. The charge on hydrometeor plays a prominent role when a charged hydrometeor has a smaller size, and it is easier to initiate a streamer in this case. At 0.25 Ek, a positive streamer discharge has been presented for a charged hydrometeor with a radius of 0.5 mm. The critical field to form streamer discharge for a column shape hydrometeor without charge is much smaller than that for a spherical hydrometeor. If smaller hydrometeors are charged, the critical field for a spherical hydrometeor becomes lower than that for a column one. The electric quantity charged on hydrometeor has little effect on the critical field for both spherical and column hydrometeors, when the hydrometeor size is larger enough. The charge on hydrometeor plays a dominant role in streamer initiation when hydrometeor is smaller, but hydrometeor shape becomes more important for larger hydrometeor. Streamer discharge can be predicted by Meek number, but stable streamer cannot be ensured. Streamer branch will be met when ambient field is lower than 0.25 Ek.
- 1 July 2021
- Published by Elsevier in Journal of Electrostatics
- Vol. 112
Understanding the dependence of streamer initiation on hydrometeors size using Raether-Meek criterion
- 1 July 2021
- Published by Elsevier in Journal of Electrostatics
- Vol. 112
Understanding the dependence of streamer initiation on hydrometeors size using Raether-Meek criterion
- 1 July 2020
- Published by Elsevier in Journal of Electrostatics
- Vol. 106
Streamer discharge initiation from an isolated spherical hydrometeor at subbreakdown condition
- 1 July 2020
- Published by Elsevier in Journal of Electrostatics
- Vol. 106
Streamer discharge initiation from an isolated spherical hydrometeor at subbreakdown condition
- 27 August 2019
- Published by IOP Publishing in Plasma Research Express
- Vol. 1 (3) , 035009
Streamer initiation from column hydrometeor at weak ambient electric field
In this work, an isolated dielectric column with rigid interface is used to demonstrate the process of streamer initiation from a real hydrometeor in cloud at weak ambient field. For a hydrometeor made of water or ice, it can be approximated as a conductor in electrostatic field. A system with two identical conducting spheres electrically connected by a thin wire has similar electric field distribution as a conducting column, which is adopted to find the electric field of the polarized column conductor in an ambient field. The modeling results show that electric field is significantly enhanced around the tips of the hydrometeor. At 0.5 E k , a positive streamer can be initiated from the positive tip of the hydrometeor, and no negative streamer is generated at the other tip. Although the main features of the positive streamer are similar with those reported previously on the positive streamer initiated from an ionization column, significant differences exist because the present model of the hydrometeor has a rigid surface. Peak electric field undergoes a slight decrease before it begins increasing, and both peak electric field and electron density have not reached steady values during our simulation time interval. The simulation results also confirm the finding from the ionization column model that when the hydrometeor length is longer, the streamer discharge can be initiated at a lower electric field. The charge accumulation on the hydrometeor and the accumulation rate show that the electron flux on the surface of the hydrometeor undergoes a complex process, which needs to be studied in the future.
- 27 August 2019
- Published by IOP Publishing in Plasma Research Express
- Vol. 1 (3) , 035009
Streamer initiation from column hydrometeor at weak ambient electric field
In this work, an isolated dielectric column with rigid interface is used to demonstrate the process of streamer initiation from a real hydrometeor in cloud at weak ambient field. For a hydrometeor made of water or ice, it can be approximated as a conductor in electrostatic field. A system with two identical conducting spheres electrically connected by a thin wire has similar electric field distribution as a conducting column, which is adopted to find the electric field of the polarized column conductor in an ambient field. The modeling results show that electric field is significantly enhanced around the tips of the hydrometeor. At 0.5 E k , a positive streamer can be initiated from the positive tip of the hydrometeor, and no negative streamer is generated at the other tip. Although the main features of the positive streamer are similar with those reported previously on the positive streamer initiated from an ionization column, significant differences exist because the present model of the hydrometeor has a rigid surface. Peak electric field undergoes a slight decrease before it begins increasing, and both peak electric field and electron density have not reached steady values during our simulation time interval. The simulation results also confirm the finding from the ionization column model that when the hydrometeor length is longer, the streamer discharge can be initiated at a lower electric field. The charge accumulation on the hydrometeor and the accumulation rate show that the electron flux on the surface of the hydrometeor undergoes a complex process, which needs to be studied in the future.
- 20 July 2016
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 30 (19)
Liquid–solid transition of water confined in nanoporous titanium dioxide
In this work, we performed differential scanning calorimetry (DSC) experiments to investigate the phase transition temperature and the molar enthalpy of the absorbed water confined in porous titanium dioxide. The porous titanium dioxide with three different pore size distribution and different filling fraction of the absorbed water were examined. We found that both the pore size of the examined samples and the filling fraction of the absorbed water affected the water’s phase transition temperature and its molar enthalpy.
- 20 July 2016
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 30 (19)
Liquid–solid transition of water confined in nanoporous titanium dioxide
In this work, we performed differential scanning calorimetry (DSC) experiments to investigate the phase transition temperature and the molar enthalpy of the absorbed water confined in porous titanium dioxide. The porous titanium dioxide with three different pore size distribution and different filling fraction of the absorbed water were examined. We found that both the pore size of the examined samples and the filling fraction of the absorbed water affected the water’s phase transition temperature and its molar enthalpy.
- 1 June 2016
- Published by Elsevier in Journal of Electrostatics
- Vol. 81, 54-58
Time-dependent interaction across two conducting spheres in an applied electrostatic field
- 1 June 2016
- Published by Elsevier in Journal of Electrostatics
- Vol. 81, 54-58
Time-dependent interaction across two conducting spheres in an applied electrostatic field
- 1 February 2016
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 113 (4) , 47007
Mechanism of the typical relaxation process at low frequency based on dielectric measurements of water absorbed in porous titanium dioxide
Dielectric spectroscopy is a valuable tool in physics, chemistry, biophysics, and materials science. However, there is still an argument about the typical relaxation process at low frequency, which is always masked by electrode polarization. Low-frequency dielectric measurements of water absorbed in porous titanium dioxide have been performed. The experimental results show that typical polarization at low frequency is caused by space-charge polarization. A model is proposed to explain the experimental results, which indicates that the electric field in the sample is close to 0. An effective circuit is given, and the calculation gives similar dielectric spectra to those measured in experiments, which confirms the physical model.
- 1 February 2016
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 113 (4) , 47007
Mechanism of the typical relaxation process at low frequency based on dielectric measurements of water absorbed in porous titanium dioxide
Dielectric spectroscopy is a valuable tool in physics, chemistry, biophysics, and materials science. However, there is still an argument about the typical relaxation process at low frequency, which is always masked by electrode polarization. Low-frequency dielectric measurements of water absorbed in porous titanium dioxide have been performed. The experimental results show that typical polarization at low frequency is caused by space-charge polarization. A model is proposed to explain the experimental results, which indicates that the electric field in the sample is close to 0. An effective circuit is given, and the calculation gives similar dielectric spectra to those measured in experiments, which confirms the physical model.
- 1 February 2016
- Published by IOP Publishing in Chinese Physics B
- Vol. 25 (2) , 026801
Vibrational features of confined water in nanoporous TiO 2 by Raman spectra
Raman spectra of confined water adsorbed in nanoporous TiO2 are obtained in experiment. TiO2 samples with different pore diameters under different humidity conditions are investigated. The results indicate that the symmetric vibrational mode of water molecule is destroyed when relative humidity decreases. This indicates that the interaction between water molecules and surface of TiO2 becomes stronger when the distance between water molecules and surface turns smaller, and the interaction plays a major role in depressing the symmetric vibrational peak. The spectra of confined water in TiO2 and Vycor are compared. When filling fractions are the same, their spectra show distinctions no matter whether they are in partial filling condition or in full filling condition. The spectra of HDO confined in TiO2 with different filling fractions are compared with each other. There is no clear distinction among their vibrational peaks, and the peaks mainly relate to asymmetric vibration. Therefore, the interaction between water molecules and the wall of pore decouples the symmetric vibrational mode only, and the influences on asymmetric vibrational mode show little differences among different filling fractions.
- 1 February 2016
- Published by IOP Publishing in Chinese Physics B
- Vol. 25 (2) , 026801
Vibrational features of confined water in nanoporous TiO 2 by Raman spectra
Raman spectra of confined water adsorbed in nanoporous TiO2 are obtained in experiment. TiO2 samples with different pore diameters under different humidity conditions are investigated. The results indicate that the symmetric vibrational mode of water molecule is destroyed when relative humidity decreases. This indicates that the interaction between water molecules and surface of TiO2 becomes stronger when the distance between water molecules and surface turns smaller, and the interaction plays a major role in depressing the symmetric vibrational peak. The spectra of confined water in TiO2 and Vycor are compared. When filling fractions are the same, their spectra show distinctions no matter whether they are in partial filling condition or in full filling condition. The spectra of HDO confined in TiO2 with different filling fractions are compared with each other. There is no clear distinction among their vibrational peaks, and the peaks mainly relate to asymmetric vibration. Therefore, the interaction between water molecules and the wall of pore decouples the symmetric vibrational mode only, and the influences on asymmetric vibrational mode show little differences among different filling fractions.