Vânia Almeida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vânia Almeida has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- João M. R. Cardoso
LIBPhys, Department of Physics, University of Coimbra, 3004-516 Coimbra, Portugal
27 shared publications - Helena Catarina Pereira
University of Coimbra
25 shared publications - Tania Pereira
INESC TEC,Porto,Portugal
25 shared publications - Carlos Manuel B. A. Correia
Centro de Instrumentação, Dept. de Física, Universidade de Coimbra, 3004-516 Coimbra, Portugal
22 shared publications E. Borges
7 shared publications- Inês P. Santos
Molecular Physical-Chemistry R&D Unit, Department of Chemistry, University of Coimbra, 3004-535 Coimbra, Portugal
5 shared publications
Latest Publications
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2017 (1557170X) , 2223-2226
Detecting dynamical changes in vital signs using switching Kalman filter
Vital signs contain valuable information about patients' health status during their stay in general wards, when the deterioration process begins. The use of methods to predict and detect regime changes such as switching models can help to understand how vital sign dynamics are altered in disease conditions. However, time series of vital signs are remarkably non-stationary in these scenarios. The objective of this study is to quantify the potential bias of switching models in the presence of non-stationarities, when the inputs are spectral, symbolic and entropy indices. To distinguish stationary from non-stationary periods, a test was used to verify the stability of the mean and variance over short periods. Then, we compared the results from a switching Kalman filter (SKF) model trained using indices obtained over stationary periods with a model trained solely over non-stationary periods. It was observed that indices measured over stationary and non-stationary periods were significantly different. The results of switching models were highly dependent on the indices that were used as inputs. The multi-scale entropy (MSE) approach presented the highest correlation values between non-stationary and stationary switches, an average correlation coefficient of 38%.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2017 (1557170X) , 2223-2226
Detecting dynamical changes in vital signs using switching Kalman filter
Vital signs contain valuable information about patients' health status during their stay in general wards, when the deterioration process begins. The use of methods to predict and detect regime changes such as switching models can help to understand how vital sign dynamics are altered in disease conditions. However, time series of vital signs are remarkably non-stationary in these scenarios. The objective of this study is to quantify the potential bias of switching models in the presence of non-stationarities, when the inputs are spectral, symbolic and entropy indices. To distinguish stationary from non-stationary periods, a test was used to verify the stability of the mean and variance over short periods. Then, we compared the results from a switching Kalman filter (SKF) model trained using indices obtained over stationary periods with a model trained solely over non-stationary periods. It was observed that indices measured over stationary and non-stationary periods were significantly different. The results of switching models were highly dependent on the indices that were used as inputs. The multi-scale entropy (MSE) approach presented the highest correlation values between non-stationary and stationary switches, an average correlation coefficient of 38%.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 940-943
Early warnings of heart rate deterioration
Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with severe sepsis. Different indicators were considered: 1) generic early warning indicators used in ecosystems analysis (autocorrelation at-1-lag (ACF1), standard deviation (SD), skewness, kurtosis and heteroskedasticity) and 2) entropy analysis (kernel entropy and multi scale entropy). Our preliminary findings suggest that when a critical transition is approaching, the equilibrium state changes what is visible in the ACF1 and SD values, but also by the analysis of the entropy. Entropy allows to characterize the complexity of the time series during the hospital stay and can be used as an indicator of regime shifts in a patient's condition. One of the main problems is its dependency of the scale used. Our results demonstrate that different entropy scales should be used depending of the level of entropy verified.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 940-943
Early warnings of heart rate deterioration
Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with severe sepsis. Different indicators were considered: 1) generic early warning indicators used in ecosystems analysis (autocorrelation at-1-lag (ACF1), standard deviation (SD), skewness, kurtosis and heteroskedasticity) and 2) entropy analysis (kernel entropy and multi scale entropy). Our preliminary findings suggest that when a critical transition is approaching, the equilibrium state changes what is visible in the ACF1 and SD values, but also by the analysis of the entropy. Entropy allows to characterize the complexity of the time series during the hospital stay and can be used as an indicator of regime shifts in a patient's condition. One of the main problems is its dependency of the scale used. Our results demonstrate that different entropy scales should be used depending of the level of entropy verified.
- 5 March 2016
- Published by Springer Nature
- p. 147-157
Measures for Combining Prediction Intervals Uncertainty and Reliability in Forecasting
- 5 March 2016
- Published by Springer Nature
- p. 147-157
Measures for Combining Prediction Intervals Uncertainty and Reliability in Forecasting
- 16 February 2016
- Published by Springer Nature
- p. 995-1005
Hierarchical Time Series Forecast in Electrical Grids
- 16 February 2016
- Published by Springer Nature
- p. 995-1005
Hierarchical Time Series Forecast in Electrical Grids
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Prediction intervals for electric load forecast: Evaluation for different profiles
Electricity industries throughout the world have been using load profiles for many years. Electrical load data contain valuable information that can be useful for both electricity producers and consumers. Load forecasting is a fundamental and important task to operate power systems efficiently and economically. Currently, prediction intervals (PIs) are assuming increasing importance comparatively to point forecast that cannot properly handle forecast uncertainties, since they are capable to compromise informativeness and correctness. This paper aims to demonstrate that different demand profiles clearly influence PIs reliability and width. The evaluation is performed using data from different customers on the basis of their electricity behavior using hierarchical clustering, and taking the Kullback-Leibler divergence as the distance metric. PIs are obtained using two different strategies: (1) dual perturb and combine algorithm and (2) conformal prediction. It was possible to demonstrate that different demand profiles clearly influence PI reliability and width for both models. The knowledge retrieved from the analysis of the load patterns is useful and can be used to support the selection of the best method to interval forecast, considering a specific location. And also, it can support the selection of an optimum confidence level, considering that a too wide PI conveys little information and is of no use for decision making.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Prediction intervals for electric load forecast: Evaluation for different profiles
Electricity industries throughout the world have been using load profiles for many years. Electrical load data contain valuable information that can be useful for both electricity producers and consumers. Load forecasting is a fundamental and important task to operate power systems efficiently and economically. Currently, prediction intervals (PIs) are assuming increasing importance comparatively to point forecast that cannot properly handle forecast uncertainties, since they are capable to compromise informativeness and correctness. This paper aims to demonstrate that different demand profiles clearly influence PIs reliability and width. The evaluation is performed using data from different customers on the basis of their electricity behavior using hierarchical clustering, and taking the Kullback-Leibler divergence as the distance metric. PIs are obtained using two different strategies: (1) dual perturb and combine algorithm and (2) conformal prediction. It was possible to demonstrate that different demand profiles clearly influence PI reliability and width for both models. The knowledge retrieved from the analysis of the load patterns is useful and can be used to support the selection of the best method to interval forecast, considering a specific location. And also, it can support the selection of an optimum confidence level, considering that a too wide PI conveys little information and is of no use for decision making.
- 1 April 2015
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 18, 394-400
Signal (Stream) synchronization with White noise sources, in biomedical applications
- 1 April 2015
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 18, 394-400
Signal (Stream) synchronization with White noise sources, in biomedical applications
- 2 November 2014
- Published by Springer Nature
- p. 54-73
Pine Decay Assessment by Means of Electrical Impedance Spectroscopy
- 2 November 2014
- Published by Springer Nature
- p. 54-73
Pine Decay Assessment by Means of Electrical Impedance Spectroscopy
- 1 November 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 117 (2) , 257-266
Cardiovascular risk analysis by means of pulse morphology and clustering methodologies
- 1 November 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 117 (2) , 257-266
Cardiovascular risk analysis by means of pulse morphology and clustering methodologies
- 1 January 2014
- Published by INSTICC
- p. 221-228
Reproducibility of Pulse Wave Analysis and Pulse Wave Velocity in Healthy Subjects
- 1 January 2014
- Published by INSTICC
- p. 221-228
Reproducibility of Pulse Wave Analysis and Pulse Wave Velocity in Healthy Subjects