Hajo Hund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hajo Hund has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Aad van der Lugt
Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands
3 shared publicationsGeert J. Lycklama À Nijeholt
Department of Radiology, Haaglanden Medical Centrum, The Hague, The Netherlands
3 shared publicationsAdriaan C. G. M. van Es
Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands
2 shared publications- Arjen Kolk
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands; Laboratory for Kinematics and Neuromechanics, Department of Orthopaedics and Rehabilitation, Leiden University Medical Center, Leiden, The Netherlands
2 shared publications Bregje J.W. Thomassen
Department of Orthopaedic Surgery and Trauma, Haaglanden Medical Center, The Hague, the Netherlands
2 shared publicationsDaniel Hansen
Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 25 January 2023
- Published by Springer Nature in Neuroradiology
- Vol. 65 (5) , 933-943
Association between thrombus composition and stroke etiology in the MR CLEAN Registry biobank
Purpose: The composition of thrombi retrieved during endovascular thrombectomy (EVT) in acute ischemic stroke (AIS) due to large vessel occlusion (LVO) may differ depending on their origin. In this study, we investigated the association between thrombus composition and stroke etiology in a large population of patients from the Dutch MR CLEAN Registry treated with EVT in daily clinical practice. Methods: The thrombi of 332 patients with AIS were histologically analyzed for red blood cells (RBC), fibrin/platelets (F/P), and white blood cells (leukocytes) using a machine learning algorithm. Stroke etiology was assessed using the Trial of Org 10,172 in acute stroke treatment (TOAST) classification. Results: The thrombi of cardioembolic origin contained less RBC and more F/P than those of non-cardioembolic origin (25.8% vs 41.2% RBC [p = 0.003] and 67.1% vs 54.5% F/P [p = 0.004]). The likelihood of a non-cardioembolic source of stroke increased with increasing thrombus RBC content (OR 1.02; [95% CI 1.00–1.06] for each percent increase) and decreased with a higher F/P content (OR 1.02; [95% CI 1.00–1.06]). Thrombus composition in patients with a cardioembolic origin and undetermined origin was similar. Conclusion: Thrombus composition is significantly associated with stroke etiology, with an increase in RBC and a decrease in F/P raising the odds for a non-cardioembolic cause. No difference between composition of cardioembolic thrombi and of undetermined origin was seen. This emphasizes the need for more extensive monitoring for arrhythmias and/or extended cardiac analysis in case of an undetermined origin.
- 25 January 2023
- Published by Springer Nature in Neuroradiology
- Vol. 65 (5) , 933-943
Open AccessAssociation between thrombus composition and stroke etiology in the MR CLEAN Registry biobank
Purpose: The composition of thrombi retrieved during endovascular thrombectomy (EVT) in acute ischemic stroke (AIS) due to large vessel occlusion (LVO) may differ depending on their origin. In this study, we investigated the association between thrombus composition and stroke etiology in a large population of patients from the Dutch MR CLEAN Registry treated with EVT in daily clinical practice. Methods: The thrombi of 332 patients with AIS were histologically analyzed for red blood cells (RBC), fibrin/platelets (F/P), and white blood cells (leukocytes) using a machine learning algorithm. Stroke etiology was assessed using the Trial of Org 10,172 in acute stroke treatment (TOAST) classification. Results: The thrombi of cardioembolic origin contained less RBC and more F/P than those of non-cardioembolic origin (25.8% vs 41.2% RBC [p = 0.003] and 67.1% vs 54.5% F/P [p = 0.004]). The likelihood of a non-cardioembolic source of stroke increased with increasing thrombus RBC content (OR 1.02; [95% CI 1.00–1.06] for each percent increase) and decreased with a higher F/P content (OR 1.02; [95% CI 1.00–1.06]). Thrombus composition in patients with a cardioembolic origin and undetermined origin was similar. Conclusion: Thrombus composition is significantly associated with stroke etiology, with an increase in RBC and a decrease in F/P raising the odds for a non-cardioembolic cause. No difference between composition of cardioembolic thrombi and of undetermined origin was seen. This emphasizes the need for more extensive monitoring for arrhythmias and/or extended cardiac analysis in case of an undetermined origin.
- Open Access
- 3 July 2018
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 7 (13) , e008563
High‐Resolution Imaging of Interaction Between Thrombus and Stent‐Retriever in Patients With Acute Ischemic Stroke
Background: Currently, acute ischemic stroke is still a leading cause of mortality and morbidity. Approximately 2 years ago, mechanical thrombectomy was proven beneficial as a revolutionary new therapy for stroke in the MR ‐CLEAN trial (A Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands). However, the mechanisms by which the thrombectomy device, or stent‐retriever, interacts with the thrombus are largely unknown. A better understanding could lead to improved efficacy of mechanical thrombectomy devices. Methods and Results: Seven stent‐retrievers with thrombi still entrapped were collected directly after thrombectomy. The stent‐retrievers were studied using micro computed tomography, followed by scanning electron microscopy and light microscopy. Two independent observers rated interaction type and thrombus surface structure (porous filamentous or dense) at the interaction sites. A total of 79 interaction sites between thrombus and stent‐retriever were categorized. Thrombus‐stent‐retriever interaction was found to be adhesive (n=44; 56%) or mechanical (n=35; 44%). Adhesive interaction was most frequently observed at interaction sites with a dense surface, compared with interaction sites with a porous filamentous fibrin surface (38/58; 66% versus 6/21; 29%, P =0.011). Conclusions: The interaction between thrombus and stent‐retriever was predominantly adhesive, not mechanical. Adhesive interaction was strongly associated with the presence of a dense thrombus surface without a porous filamentous fibrin network.
- 3 July 2018
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 7 (13) , e008563
Open AccessHigh‐Resolution Imaging of Interaction Between Thrombus and Stent‐Retriever in Patients With Acute Ischemic Stroke
Background: Currently, acute ischemic stroke is still a leading cause of mortality and morbidity. Approximately 2 years ago, mechanical thrombectomy was proven beneficial as a revolutionary new therapy for stroke in the MR ‐CLEAN trial (A Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands). However, the mechanisms by which the thrombectomy device, or stent‐retriever, interacts with the thrombus are largely unknown. A better understanding could lead to improved efficacy of mechanical thrombectomy devices. Methods and Results: Seven stent‐retrievers with thrombi still entrapped were collected directly after thrombectomy. The stent‐retrievers were studied using micro computed tomography, followed by scanning electron microscopy and light microscopy. Two independent observers rated interaction type and thrombus surface structure (porous filamentous or dense) at the interaction sites. A total of 79 interaction sites between thrombus and stent‐retriever were categorized. Thrombus‐stent‐retriever interaction was found to be adhesive (n=44; 56%) or mechanical (n=35; 44%). Adhesive interaction was most frequently observed at interaction sites with a dense surface, compared with interaction sites with a porous filamentous fibrin surface (38/58; 66% versus 6/21; 29%, P =0.011). Conclusions: The interaction between thrombus and stent‐retriever was predominantly adhesive, not mechanical. Adhesive interaction was strongly associated with the presence of a dense thrombus surface without a porous filamentous fibrin network.
- Open Access
- 25 January 2018
- Published by S. Karger AG in Interventional Neurology
- Vol. 7 (3-4) , 137-147
Importance of Reperfusion Status after Intra-Arterial Thrombectomy for Prediction of Outcome in Anterior Circulation Large Vessel Stroke
Background: Reperfusion status after intra-arterial thrombectomy (IAT) is a critical predictor of functional outcome after acute ischemic stroke. However, most prognostic models have not included a detailed assessment of reperfusion status after IAT. Objective: The aim of this work was to assess the association between successful reperfusion and clinical outcome. Methods: Clinical, radiological, and procedural variables of patients treated with IAT were extracted from our prospective stroke registry. The association with functional outcome using the modified Rankin Scale (mRS) after 3 months was assessed using multivariable logistic regression. An extension of the modified TICI score, eTICI, was used to classify reperfusion status. The prognostic value of reperfusion status after IAT in addition to age, stroke severity, imaging characteristics, treatment with intravenous thrombolysis, and time from symptom onset to the end of IAT was assessed with logistic regression and summarized with receiver operating characteristic curves. Results: In total, 119 patients were included (mean age 66 years). In multivariable analysis, age >80 years (OR 6.8, 95% CI 1.2–39.8), NIHSS at presentation >15 (OR 7.3, 95% CI 2.3–23.5), and incomplete reperfusion status (eTICI score Conclusion: Our results promote using reperfusion status for assessing prognosis in ischemic stroke patients treated with IAT. A model using eTICI ≥2C had greater PPV than eTICI ≥2B and could improve prognostic accuracy.
- 25 January 2018
- Published by S. Karger AG in Interventional Neurology
- Vol. 7 (3-4) , 137-147
Open AccessImportance of Reperfusion Status after Intra-Arterial Thrombectomy for Prediction of Outcome in Anterior Circulation Large Vessel Stroke
Background: Reperfusion status after intra-arterial thrombectomy (IAT) is a critical predictor of functional outcome after acute ischemic stroke. However, most prognostic models have not included a detailed assessment of reperfusion status after IAT. Objective: The aim of this work was to assess the association between successful reperfusion and clinical outcome. Methods: Clinical, radiological, and procedural variables of patients treated with IAT were extracted from our prospective stroke registry. The association with functional outcome using the modified Rankin Scale (mRS) after 3 months was assessed using multivariable logistic regression. An extension of the modified TICI score, eTICI, was used to classify reperfusion status. The prognostic value of reperfusion status after IAT in addition to age, stroke severity, imaging characteristics, treatment with intravenous thrombolysis, and time from symptom onset to the end of IAT was assessed with logistic regression and summarized with receiver operating characteristic curves. Results: In total, 119 patients were included (mean age 66 years). In multivariable analysis, age >80 years (OR 6.8, 95% CI 1.2–39.8), NIHSS at presentation >15 (OR 7.3, 95% CI 2.3–23.5), and incomplete reperfusion status (eTICI score Conclusion: Our results promote using reperfusion status for assessing prognosis in ischemic stroke patients treated with IAT. A model using eTICI ≥2C had greater PPV than eTICI ≥2B and could improve prognostic accuracy.
- 4 January 2018
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 27 (3) , e84-e85
Response to Hustedt et al regarding: “Does acromioplasty result in favorable clinical and radiologic outcomes in the management of chronic subacromial pain syndrome? A double-blinded randomized clinical trial with 9 to 14 years' follow-up”
- 4 January 2018
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 27 (3) , e84-e85
Response to Hustedt et al regarding: “Does acromioplasty result in favorable clinical and radiologic outcomes in the management of chronic subacromial pain syndrome? A double-blinded randomized clinical trial with 9 to 14 years' follow-up”
- Open Access
- 12 August 2017
- Published by Springer Nature in Acta Neurologica Belgica
- Vol. 117 (3) , 637-642
Unknown onset ischemic strokes in patients last-seen-well >4.5 h: differences between wake-up and daytime-unwitnessed strokes
Patients with unknown time of stroke onset (UOS) represent around one-third of ischemic stroke patients. These are patients with wake-up stroke (WUS) or daytime-unwitnessed stroke (DUS), often presenting outside the time-window for reperfusion therapy. UOS patients presenting between 4.5 and 12 h after time of last-seen-well were included. Clinical and imaging characteristics were compared between WUS and DUS patients. Good functional outcome was defined as a modified Rankin scale of ≤2 at follow-up. Sixty-one UOS patients were included: 42 WUS and 19 DUS patients. Stroke severity at presentation was mild to moderate with a median National Institutes of Health Stroke Scale of 5 in WUS and 6 in DUS patients. Time between last-seen-well and presentation at the hospital was shorter in patients with DUS compared to WUS (506 vs 362 min, p < 0.01). CT imaging results were similar, with a median Alberta Stroke Program Early CT Score of 10 for both WUS and DUS patients. After correction for age and NIHSS at presentation, no difference in good functional outcome was found between WUS (52%) and DUS (22%). In patients with unknown onset ischemic strokes presenting between 4.5 and 12 h after time of last-seen-well, clinical and radiological features were in large part similar between WUS and DUS. The outcome in the overall cohort was rather poor despite a favorable neuroimaging profile at presentation. These findings underscore the need for clinical trials in patients in whom stroke onset time is unknown.
- 12 August 2017
- Published by Springer Nature in Acta Neurologica Belgica
- Vol. 117 (3) , 637-642
Open AccessUnknown onset ischemic strokes in patients last-seen-well >4.5 h: differences between wake-up and daytime-unwitnessed strokes
Patients with unknown time of stroke onset (UOS) represent around one-third of ischemic stroke patients. These are patients with wake-up stroke (WUS) or daytime-unwitnessed stroke (DUS), often presenting outside the time-window for reperfusion therapy. UOS patients presenting between 4.5 and 12 h after time of last-seen-well were included. Clinical and imaging characteristics were compared between WUS and DUS patients. Good functional outcome was defined as a modified Rankin scale of ≤2 at follow-up. Sixty-one UOS patients were included: 42 WUS and 19 DUS patients. Stroke severity at presentation was mild to moderate with a median National Institutes of Health Stroke Scale of 5 in WUS and 6 in DUS patients. Time between last-seen-well and presentation at the hospital was shorter in patients with DUS compared to WUS (506 vs 362 min, p < 0.01). CT imaging results were similar, with a median Alberta Stroke Program Early CT Score of 10 for both WUS and DUS patients. After correction for age and NIHSS at presentation, no difference in good functional outcome was found between WUS (52%) and DUS (22%). In patients with unknown onset ischemic strokes presenting between 4.5 and 12 h after time of last-seen-well, clinical and radiological features were in large part similar between WUS and DUS. The outcome in the overall cohort was rather poor despite a favorable neuroimaging profile at presentation. These findings underscore the need for clinical trials in patients in whom stroke onset time is unknown.
- Open Access
- 29 June 2017
- Published by Wiley in Brain and Behavior
- Vol. 7 (8) , e00750
Duplex ultrasonography for the detection of vertebral artery stenosis
Objectives: Vertebrobasilar stenosis is frequent in patients with posterior circulation stroke and it increases risk of recurrence. We investigated feasibility of duplex ultrasonography (DUS) for screening for extracranial vertebral artery stenosis and compared it with CT angiography (CTA).Materials and Methods: We gathered data on 337 consecutive patients who had DUS because of posterior circulation stroke or TIA. Matching CTA studies were retrieved and used as reference. Stenosis on CTA was considered “significant” if >50%, at DUS if Peak Systolic Velocity (PSV) > 140 cm/s for the V1 segment and PSV > 125 cm/s for the V2 segment. We determined the area under the ROC curve (AUROC). In addition, we calculated which PSV cut‐off value resulted in highest sensitivity with acceptable specificity.Results: DUS was able to make an adequate measurement in 378 of 674 V1 segments and 673 of 674 V2 segments. DUS detected a significant stenosis in 52 of 378 V1 segments; 12 were confirmed by CTA (AUROC 0.73, 95% Confidence Interval 0.63–0.83). The optimal DUS PSV cut‐off value for this segment was 90 cm/s. For the V2 segment there were too few stenoses to allow reliable assessment of diagnostic characteristics of DUS.Conclusions: Although DUS has a fair AUROC for detecting significant stenosis, adequate assessment of the V1 segment is often not possible due to anatomic difficulties. Assessment of the V2 segment is feasible but yielded few stenoses. Hence, we consider usefulness of DUS for screening of extracranial vertebral artery stenosis limited.
- 29 June 2017
- Published by Wiley in Brain and Behavior
- Vol. 7 (8) , e00750
Open AccessDuplex ultrasonography for the detection of vertebral artery stenosis
Objectives: Vertebrobasilar stenosis is frequent in patients with posterior circulation stroke and it increases risk of recurrence. We investigated feasibility of duplex ultrasonography (DUS) for screening for extracranial vertebral artery stenosis and compared it with CT angiography (CTA).Materials and Methods: We gathered data on 337 consecutive patients who had DUS because of posterior circulation stroke or TIA. Matching CTA studies were retrieved and used as reference. Stenosis on CTA was considered “significant” if >50%, at DUS if Peak Systolic Velocity (PSV) > 140 cm/s for the V1 segment and PSV > 125 cm/s for the V2 segment. We determined the area under the ROC curve (AUROC). In addition, we calculated which PSV cut‐off value resulted in highest sensitivity with acceptable specificity.Results: DUS was able to make an adequate measurement in 378 of 674 V1 segments and 673 of 674 V2 segments. DUS detected a significant stenosis in 52 of 378 V1 segments; 12 were confirmed by CTA (AUROC 0.73, 95% Confidence Interval 0.63–0.83). The optimal DUS PSV cut‐off value for this segment was 90 cm/s. For the V2 segment there were too few stenoses to allow reliable assessment of diagnostic characteristics of DUS.Conclusions: Although DUS has a fair AUROC for detecting significant stenosis, adequate assessment of the V1 segment is often not possible due to anatomic difficulties. Assessment of the V2 segment is feasible but yielded few stenoses. Hence, we consider usefulness of DUS for screening of extracranial vertebral artery stenosis limited.