LFLide Fang

Lide Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lide Fang has a total of 224 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A visual Mamba-based global-local framework for instance segmentation of highly overlapping multi-scale bubbles in dense two-phase flows

    by Mi Wang, Kaijie Tong, Xinxin Li, Shaofang Li, Lide Fang

    To address the identification and segmentation challenges caused by large bubble size variations, dense distributions, and severe overlap and occlusion in gas–liquid two-phase flows, a global-local fusion segmentation model named global-local bubble network is designed. The model uses the visual state space encoder as the backbone for feature extraction. By utilizing the two-dimensional selective scan mechanism with linear complexity, it establishes long-range pixel dependencies, significantly enhancing context inference capabilities under dense occlusion. Simultaneously, a global-local slicing interface is proposed, which effectively eliminates edge truncation artifacts inherent in high-resolution image tiling through overlap-based slicing augmentation during training and boundary-aware reconstruction inference during inference, ensuring the topological integrity of cross-scale targets. Finally, an adaptive receptive field aggregation neck incorporating a selective Kernel Atrous spatial pyramid pooling module is introduced to dynamically adjust receptive field weights and fuse deep semantic features with shallow texture features, thereby effectively improving the segmentation accuracy of multi-scale bubbles. Compared with mainstream single-stage and multi-stage instance segmentation frameworks, the proposed model shows superior segmentation performance and robustness in simulation experiments. Its comprehensive F1-score reaches 99.89%, and the Mean Intersection over Union (mIoU) reaches 95.11%. Applied to real bubbly flow experiments, it attains an average F1-score of 91.55% and an average mIoU of 94.39% under rigorous fivefold cross-validation, maintaining superior and stable performance under complex conditions. This provides a reliable solution for the refined parameter statistics of complex multiphase flow fields.

  • Viscosity Correlation for Binary Mixtures of Ethyl Octanoate and n -Alcohols Using an Improved MTSM Model

    by Xiaojie Wang, Chengyuan Peng, Zhiqiang Hong, Jidong Liu, Chenkai Dai, Yingjie Ma, Jianing Huo, Yujie Yang, Bangbang Han, Lide Fang

    The viscosities of binary mixtures of ethyl octanoate and C3/C5–C7 n-alcohols were investigated on the basis of experimental data measured with a self-designed capillary viscometer over the temperature range of 293–333 K, using four models [modified two-suffix-Margules (MTSM), nonrandom two-liquid, Frenkel, and Jouyban–Acree). The MTSM model shows better accuracy. To improve predictive accuracy, a correction term H related to equivalent molar mass was introduced, incorporating molecular weight effects. The correlation coefficient between H and the ln η is 0.95. The average deviation of the improved MTSM model is reduced by 3.44 × 10–4, the interquartile range of the distribution of absolute relative deviation decreased by 0.26%, and the average absolute relative deviation is reduced by 0.30%, compared to the original MTSM model, overall. This study improved viscosity data and an improved predictive approach for ethyl octanoate + n-alcohol mixtures.

  • An image processing method for gas plug head characteristic parameters measurement and prediction in horizontal gas–liquid plug flow

    by Ning Zhao, Haodi Jia, Keke Chen, Lei Gao, Lide Fang, Jiaqi Wen, Zhiyue Zhao

    Gas–liquid plug flow is prevalent in various industrial processes, including oil extraction, and the flow state at the shale gas wellhead. In the petroleum industry, it is crucial to comprehend the flow structure characteristics of the gas–liquid two-phase plug flow, which influence the design of transportation and extraction systems and are closely tied to the safety and efficiency of the petroleum production process. A parameter measurement methodology utilizing phase interface segmentation is developed based on high-speed camera technology in the paper, enabling precise identification of the gas plug outline and extraction of gas plug characteristic parameters. By applying gradient-sensitive filtering technology, integrating Canny edge detection and the improved probabilistic Hough transform, the edge detection of the pipeline wall is achieved. A dynamic segmentation technology for the phase interface gas plug region is designed to achieve outline recognition and complete segmentation of the gas plug region. By converting the pixel points of the image, the characteristic parameters of the gas plug head, including length, height, and inclination angle, are measured. Based on decision tree regression, a prediction model for the length, height, and inclination angle of the gas plug head is established. The experimental results show that the mean absolute percentage errors of the prediction models for the length, height and inclination angle of the gas plug head are all less than 5%, while 90.91%, 98.18%, and 98.18% of the experimental measurement points fall within a ±5% relative error band respectively, achieving accurate prediction of the gas plug head characteristic parameters.

  • An adjustable-pressure active dual-chamber cylindrical gas piston prover

    by Lina Niu, Yachun Jing, Qing Qin, Lide Fang

    High-pressure-loss micro gas flowmeters face key challenges in achieving high accuracy, e.g. complex low-flow regimes, limited range of traditional standards, and sealing leakage under high pressure differentials, which compromise measurement reliability. Establishing matching high-precision gas flow standards and calibration capabilities is therefore essential to support product performance verification and upgrading of these devices. This paper designs an active dual-chamber cylindrical gas piston prover. The piston prover first configures three specifications of cylindrical pistons, namely 20 ml, 200 ml, and 3 l, based on the principle of flow range proportion matching and the product type spectrum series design concept, to achieve a wide coverage of the flow range from 1 ml min −1 to 3 l min −1 . By constructing a mathematical model, the precise conversion from volumetric flow rate to mass flow rate is achieved. To address the sealing challenge under high-pressure differential conditions, an innovative ‘stacked seal assembly’ is adopted to enhance sealing reliability. Meanwhile, by integrating long short-term memory state recognition with model predictive control algorithm, an intelligent proportional-integral-derivative control strategy is developed, significantly improving the piston prover’s adaptability to complex working conditions and pressure regulation accuracy. The relative expanded uncertainty of mass flow rate ( U r ( q m ) ) is 0.097% ( k = 2). The verification results show that the accuracy and applicability of this piston prover both meet the requirements, providing a reliable measurement standard support for high-pressure loss micro gas flow meters.

  • The Instantaneous Flow Measurement Method of Ultrasonic Gas Meters

    by Lina Niu, Yachun Jing, Weiming Dou, Hangcheng Jiang, Lide Fang

  • Synergistic mechanisms of ultrasonic attenuation in multiphysics liquid–solid two-phase flow and phased-array measurement of discrete phase concentration

    by Xin Li, Zhongliang Wang, Jiayi Dong, Xiaolin Liu, Lide Fang

    Particle concentration measurement is crucial in chemical, biomedical, and environmental fields. Concentration can be determined through ultrasonic attenuation analysis. However, the complex acoustic behavior and energy dissipation mechanisms in liquid–solid two-phase suspensions have not been fully elucidated, limiting detection accuracy and application. This work analyzed ultrasonic attenuation mechanisms in low-concentration, small-particle suspensions, including Rayleigh scattering, viscous dissipation, and thermal conduction. An integrated acoustic–thermal–flow multiphysics model was developed to quantify the relationship between particle concentration and these attenuation mechanisms. An ultrasonic phased array acquired echoes from 10 μm SiO2 particle suspensions via the ultrasonic backwall echo method. Signals were decomposed using the Sym4 wavelet, denoised with SURE Shrink (optimal threshold λ∗), and their envelopes were extracted via the Hilbert transform, which were then segmented using time windows. The echo peaks were identified with a second-derivative extremum detection algorithm. A linear scanning approach was adopted at angles of 5°, 7°, and 9° to balance directivity, coverage, and signal-to-noise ratio. At each angle, concentration inversion exhibited a relative deviation (RD) within ±26%, root mean square error (RMSE) < 0.0024, and mean absolute percentage error (MAPE) < 17%, collectively validating the robustness of the proposed Integrated Model. Multi-angle data fusion was implemented to optimize global particle concentration inversion, successfully confining RD to ±20.65%, reducing RMSE to 0.00145 and MAPE to 10.39%, demonstrating that multi-angle data fusion mitigated the primary error sources in single-angle measurements. The findings provide a theoretical foundation and methodological framework for high-precision ultrasonic detection of particle concentration.


  • High-precision voltage source remote calibration and voltage-to-frequency conversion self-calibration technology

    by Lide Fang, Zeyu Zhu, Zhongliang Wang, Qingke Zhu, Mi Wang

    This paper proposes a remote DC voltage calibration system that combines GPS common-view synchronization with a self-calibrating voltage-to-frequency converter (VFC). The system uses the GPS 1 pulse-per-second signal to achieve precise time alignment and implements a dynamic self-calibration algorithm that corrects frequency conversion errors in real-time. A compact hardware design integrates a frequency counter, time interval analyzer, and VFC module into a single portable unit. By capturing the rising edge of pulses, the system can determine voltage deviation using only one measurement cycle, significantly improving speed and accuracy. Experimental results show a maximum relative error of 0.000 025%, demonstrating superior stability over traditional methods. The system reduces cost, improves automation, and offers practical value for on-site precision calibration in advanced manufacturing and instrumentation.

  • The BP model based on PSO-GA hybrid algorithm optimization for the calculation of n-alcohol densities

    by Xiaojie Wang, Chenkai Dai, Chengyuan Peng, Jidong Liu, Jing Wang, Yonggang Qi, Lide Fang