Livio Mazzarella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Livio Mazzarella has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Adriana Angelotti
Politecnico di Milano
3 shared publications - Andrea Alongi
Department of Energy, Politecnico di Milano, Via Lambruschini 4, 20156 Milano, Italy
3 shared publications - Alessandro Prada
University of Trento
1 shared publication - Cristina Cornaro
Department of Enterprise Engineering, University of Rome Tor Vergata, 00133 Rome, Italy
1 shared publication Delia D'AGostino
1 shared publication- Francesca Frasca
Sapienza University of Rome
1 shared publication
Latest Publications
- Open Access
In Situ Measurement of Wall Thermal Properties: Parametric Investigation of the Heat Flow Meter Methods through Virtual Experiments Data
Energy retrofit of existing buildings is based on the assessment of the starting performance of the envelope. The procedure for the in situ measurement of thermal conductance is described in the ISO 9869-1:2014, which provides two techniques for data processing: the average method (AM) and the dynamic method (DM). This work studies their effectiveness using virtual data from numerical simulations based on a finite difference model applied to different wall kinds, considering winter and summer boundary conditions alternatively (Italian Milan-Linate TMY). The estimated thermal conductances are compared to the reference theoretical values. The main purposes are: (i) defining the shortest test duration that provides acceptable results; (ii) assess the reliability of the criteria provided by the standard to evaluate the measurement quality; (iii) evaluate the sensitivity of both methods to variables such as wall properties, boundary conditions and others more specific to the DM (namely, the number of time constants and linear equations). The AM always provides acceptable estimates in winter (−3.1% ÷ 10% error), with better outcomes when indoor heat flux is considered, except for the highly insulated wall, but is not effective in summer, despite the fulfillment of the acceptance criteria for the highly insulated wall. The DM provides improvements in both seasons (0.05% ÷ 8.6% absolute values of error), for most virtual samples, and requires shorter sampling periods, even below the 3 days limit suggested by the standard. The test on the confidence interval indicated by the ISO 9869-1:2014 is not reliable and measurements are sensitive to the number of linear equations, that is left to the user’s discretion without strict indications. This work suggests a possible approach for overcoming this issue, which requires deeper future investigation.
Open AccessIn Situ Measurement of Wall Thermal Properties: Parametric Investigation of the Heat Flow Meter Methods through Virtual Experiments Data
Energy retrofit of existing buildings is based on the assessment of the starting performance of the envelope. The procedure for the in situ measurement of thermal conductance is described in the ISO 9869-1:2014, which provides two techniques for data processing: the average method (AM) and the dynamic method (DM). This work studies their effectiveness using virtual data from numerical simulations based on a finite difference model applied to different wall kinds, considering winter and summer boundary conditions alternatively (Italian Milan-Linate TMY). The estimated thermal conductances are compared to the reference theoretical values. The main purposes are: (i) defining the shortest test duration that provides acceptable results; (ii) assess the reliability of the criteria provided by the standard to evaluate the measurement quality; (iii) evaluate the sensitivity of both methods to variables such as wall properties, boundary conditions and others more specific to the DM (namely, the number of time constants and linear equations). The AM always provides acceptable estimates in winter (−3.1% ÷ 10% error), with better outcomes when indoor heat flux is considered, except for the highly insulated wall, but is not effective in summer, despite the fulfillment of the acceptance criteria for the highly insulated wall. The DM provides improvements in both seasons (0.05% ÷ 8.6% absolute values of error), for most virtual samples, and requires shorter sampling periods, even below the 3 days limit suggested by the standard. The test on the confidence interval indicated by the ISO 9869-1:2014 is not reliable and measurements are sensitive to the number of linear equations, that is left to the user’s discretion without strict indications. This work suggests a possible approach for overcoming this issue, which requires deeper future investigation.
- Open Access
Calibrating the Dynamic Energy Simulation Model for an Existing Building: Lessons Learned from a Collective Exercise
Calibration of the existing building simulation model is key to correctly evaluating the energy savings that are achievable through retrofit. However, calibration is a non-standard phase where different approaches can possibly lead to different models. In this study, an existing residential building is simulated in parallel by four research groups with different dynamic simulation tools. Manual/automatic methodologies and basic/detailed measurement data sets are used. The calibration is followed by a validation on two evaluation periods. Monitoring data concerning the windows opening by the occupants are used to analyze the calibration outcomes. It is found that for a good calibration of a model of a well-insulated building, the absence of data regarding the users’ behavior is more critical than uncertainty on the envelope properties. The automatic approach is more effective in managing the model complexity and reaching a better performing calibration, as the RMSE relative to indoor temperature reaches 0.3 °C compared to 0.4–0.5 °C. Yet, a calibrated model’s performance is often poor outside the calibration period (RMSE increases up to 10.8 times), and thus, the validation is crucial to discriminate among multiple solutions and to refine them, by improving the users’ behavior modeling.
Open AccessCalibrating the Dynamic Energy Simulation Model for an Existing Building: Lessons Learned from a Collective Exercise
Calibration of the existing building simulation model is key to correctly evaluating the energy savings that are achievable through retrofit. However, calibration is a non-standard phase where different approaches can possibly lead to different models. In this study, an existing residential building is simulated in parallel by four research groups with different dynamic simulation tools. Manual/automatic methodologies and basic/detailed measurement data sets are used. The calibration is followed by a validation on two evaluation periods. Monitoring data concerning the windows opening by the occupants are used to analyze the calibration outcomes. It is found that for a good calibration of a model of a well-insulated building, the absence of data regarding the users’ behavior is more critical than uncertainty on the envelope properties. The automatic approach is more effective in managing the model complexity and reaching a better performing calibration, as the RMSE relative to indoor temperature reaches 0.3 °C compared to 0.4–0.5 °C. Yet, a calibrated model’s performance is often poor outside the calibration period (RMSE increases up to 10.8 times), and thus, the validation is crucial to discriminate among multiple solutions and to refine them, by improving the users’ behavior modeling.
- 10 January 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (2) , 155-180
A numerical model to simulate the dynamic performance of Breathing Walls
A one-dimensional Finite Difference Model for Breathing Wall components under time dependent Dirichlet boundary conditions is presented. The algorithm undergoes a comprehensive validation against a dynamic analytical model, under either sinusoidal and generically periodic boundary conditions, adopting different airflow velocities and in relation to capacitive and resistive materials alternatively. It is found that the accurate prediction of the temperature profile inside the wall is influenced primarily by the timestep, whose optimal value can be identified through a preliminary frequency analysis of the boundary conditions. Moreover, for a better prediction of the surface heat flow density, and especially in insulating materials, refining the space grid below 1 mm is recommended, as well as the adoption of a 3-point numerical scheme. The numerical model is finally tested against experimental data on a porous concrete wall, showing that numerical errors may compare to other sources of uncertainties, regarding materials properties and boundary conditions.
- 10 January 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (2) , 155-180
A numerical model to simulate the dynamic performance of Breathing Walls
A one-dimensional Finite Difference Model for Breathing Wall components under time dependent Dirichlet boundary conditions is presented. The algorithm undergoes a comprehensive validation against a dynamic analytical model, under either sinusoidal and generically periodic boundary conditions, adopting different airflow velocities and in relation to capacitive and resistive materials alternatively. It is found that the accurate prediction of the temperature profile inside the wall is influenced primarily by the timestep, whose optimal value can be identified through a preliminary frequency analysis of the boundary conditions. Moreover, for a better prediction of the surface heat flow density, and especially in insulating materials, refining the space grid below 1 mm is recommended, as well as the adoption of a 3-point numerical scheme. The numerical model is finally tested against experimental data on a porous concrete wall, showing that numerical errors may compare to other sources of uncertainties, regarding materials properties and boundary conditions.
- Top Cited Papers
- 1 January 2019
- Published by Elsevier in Journal of Building Engineering
- Vol. 21, 200-212
What is a Nearly zero energy building? Overview, implementation and comparison of definitions
- 1 January 2019
- Published by Elsevier in Journal of Building Engineering
- Vol. 21, 200-212
Top Cited PapersWhat is a Nearly zero energy building? Overview, implementation and comparison of definitions
- 1 July 2018
- Published by Elsevier in Applied Acoustics
- Vol. 136, 61-75
Petrarca Theatre: A case study to identify the acoustic parameters trends and their sensitivity in a horseshoe shape opera house
- 1 July 2018
- Published by Elsevier in Applied Acoustics
- Vol. 136, 61-75
Petrarca Theatre: A case study to identify the acoustic parameters trends and their sensitivity in a horseshoe shape opera house
- Open Access
- 1 November 2015
- Published by Elsevier in Energy Procedia
- Vol. 78, 537-542
Characterization of Fibrous Insulating Materials in their Application in Dynamic Insulation Technology
- 1 November 2015
- Published by Elsevier in Energy Procedia
- Vol. 78, 537-542
Open AccessCharacterization of Fibrous Insulating Materials in their Application in Dynamic Insulation Technology