Zhongzhi Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhongzhi Jia has a total of 197 co-authors. Here are the top co-authors by number of shared publications:
Kai Wang
The Second People’s Hospital of Changzhou, The Third Affiliated Hospital of Nanjing Medical University, Changzhou, China
16 shared publicationsGuomin Jiang
11 shared publicationsLihao Qin
Nanjing Med Univ, Affiliated Changzhou Peoples Hosp 2, Dept Intervent & Vasc Surg, Changzhou 213003, Peoples R China
11 shared publicationsJunhao Mei
Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People’s Hospital, Nanjing Medical University, Changzhou, China
10 shared publications- Tongqing Xue
Department of Interventional Radiology, Huaian Hospital of Huai’an City (Huaian Cancer Hospital), Huai’an, China
10 shared publications Feng Tian
Nanjing Med Univ, Affiliated Changzhou Peoples Hosp 2, Dept Intervent & Vasc Surg, Changzhou 213003, Peoples R China
8 shared publications
Latest Publications
- 6 November 2026
- Published by Elsevier in Surgical Oncology
- Vol. 70
Lenvatinib vs sorafenib as second-line therapy after ATE+BEV failure in advanced hepatocellular carcinoma: A meta-analysis
- 6 November 2026
- Published by Elsevier in Surgical Oncology
- Vol. 70
Lenvatinib vs sorafenib as second-line therapy after ATE+BEV failure in advanced hepatocellular carcinoma: A meta-analysis
- Open Access
- 27 October 2026
- Published by Springer Nature in BioMedical Engineering OnLine
Factors associated with long-term recurrence of hemoptysis after bronchial artery embolization for bronchiectasis
- 27 October 2026
- Published by Springer Nature in BioMedical Engineering OnLine
Open AccessFactors associated with long-term recurrence of hemoptysis after bronchial artery embolization for bronchiectasis
- Open Access
- 2 September 2026
- Published by Elsevier in SSRN Electronic Journal
Four Large Language Models Versus Radiologists in Diagnosing Clinically Significant Prostate Cancer: A Multicenter Retrospective Cohort Study
Background and Aim: Accurate preoperative identification of clinically significant prostate cancer (csPCa) remains challenging due to the limited specificity of prostate-specific antigen (PSA) and the experience-dependent inter-reader variability of PI-RADS scoring. Large language models (LLMs) have shown potential in medical decision support, but their comparative performance against radiologists of varying experience and their independent predictive value in csPCa diagnosis are poorly understood. Methods: This multicenter retrospective cohort study included 1,709 patients who underwent prostate biopsy across three tertiary hospitals. Four LLMs (DeepSeek-V4 Flash, GPT-5.4, Claude Opus 4.6, and Gemini 3.1 Flash) generated csPCa probabilities and PI-RADS scores from anonymized MRI reports combined with clinical variables. Three radiologists (junior, intermediate, senior) independently assigned PI-RADS v2.1 scores. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, calibration metrics, and decision curve analysis. Logistic regression and incremental value analyses were performed. Subgroup analysis was conducted in the PSA gray zone (tPSA 4–10 μg/L). Results: Claude Opus 4.6 achieved the highest AUC among LLMs (0.840, 95% CI: 0.821–0.859), comparable to GPT-5.4 (0.839) and Gemini 3.1 Flash (0.835), and significantly outperformed DeepSeek-V4 Flash (0.777, P < 0.001). Claude Opus 4.6 showed similar discriminative ability to the senior radiologist (AUC 0.840 vs. 0.842, P = 0.866) and significantly outperformed junior (0.704) and intermediate (0.747) radiologists. PI-RADS agreement was fair with the senior radiologist (κ = 0.383) but slight with junior/intermediate radiologists. In multivariable analysis, adding Claude Opus 4.6 probability to clinical variables improved AUC from 0.851 to 0.867, but after including the senior radiologist’s PI-RADS score, the LLM probability provided no incremental value (ΔAUC = −0.0002, P = 0.616). In the PSA gray zone (n = 803, csPCa prevalence 27.0%), all evaluators showed decreased performance; the best LLM (Gemini 3.1 Flash, AUC = 0.755) performed comparably to intermediate radiologists but remained inferior to the senior radiologist (0.826). Conclusion: Claude Opus 4.6, GPT-5.4, and Gemini 3.1 Flash achieved diagnostic accuracy for csPCa comparable to that of a senior radiologist and significantly better than junior and intermediate radiologists. However, LLMs probability did not provide incremental predictive value beyond the senior radiologist’s PI-RADS score. In the challenging PSA gray zone, LLM performance dropped to the level of an intermediate radiologist. LLMs may serve as useful decision-support tools, especially in resource-limited settings, but are unlikely to replace expert human interpretation.
- 2 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFour Large Language Models Versus Radiologists in Diagnosing Clinically Significant Prostate Cancer: A Multicenter Retrospective Cohort Study
Background and Aim: Accurate preoperative identification of clinically significant prostate cancer (csPCa) remains challenging due to the limited specificity of prostate-specific antigen (PSA) and the experience-dependent inter-reader variability of PI-RADS scoring. Large language models (LLMs) have shown potential in medical decision support, but their comparative performance against radiologists of varying experience and their independent predictive value in csPCa diagnosis are poorly understood. Methods: This multicenter retrospective cohort study included 1,709 patients who underwent prostate biopsy across three tertiary hospitals. Four LLMs (DeepSeek-V4 Flash, GPT-5.4, Claude Opus 4.6, and Gemini 3.1 Flash) generated csPCa probabilities and PI-RADS scores from anonymized MRI reports combined with clinical variables. Three radiologists (junior, intermediate, senior) independently assigned PI-RADS v2.1 scores. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, calibration metrics, and decision curve analysis. Logistic regression and incremental value analyses were performed. Subgroup analysis was conducted in the PSA gray zone (tPSA 4–10 μg/L). Results: Claude Opus 4.6 achieved the highest AUC among LLMs (0.840, 95% CI: 0.821–0.859), comparable to GPT-5.4 (0.839) and Gemini 3.1 Flash (0.835), and significantly outperformed DeepSeek-V4 Flash (0.777, P < 0.001). Claude Opus 4.6 showed similar discriminative ability to the senior radiologist (AUC 0.840 vs. 0.842, P = 0.866) and significantly outperformed junior (0.704) and intermediate (0.747) radiologists. PI-RADS agreement was fair with the senior radiologist (κ = 0.383) but slight with junior/intermediate radiologists. In multivariable analysis, adding Claude Opus 4.6 probability to clinical variables improved AUC from 0.851 to 0.867, but after including the senior radiologist’s PI-RADS score, the LLM probability provided no incremental value (ΔAUC = −0.0002, P = 0.616). In the PSA gray zone (n = 803, csPCa prevalence 27.0%), all evaluators showed decreased performance; the best LLM (Gemini 3.1 Flash, AUC = 0.755) performed comparably to intermediate radiologists but remained inferior to the senior radiologist (0.826). Conclusion: Claude Opus 4.6, GPT-5.4, and Gemini 3.1 Flash achieved diagnostic accuracy for csPCa comparable to that of a senior radiologist and significantly better than junior and intermediate radiologists. However, LLMs probability did not provide incremental predictive value beyond the senior radiologist’s PI-RADS score. In the challenging PSA gray zone, LLM performance dropped to the level of an intermediate radiologist. LLMs may serve as useful decision-support tools, especially in resource-limited settings, but are unlikely to replace expert human interpretation.
- Open Access
- 24 July 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1864916
A deep learning model for the interpretable identification of pulmonary thromboembolism from computed tomography pulmonary angiography
Objective: The rapid identification of pulmonary thromboembolism (PTE) on computed tomography pulmonary angiography (CTPA) is vital but labor-intensive, often leading to diagnostic delays. We aimed to construct and evaluate a YOLOv11 object detection algorithm capable of automatically highlighting intraluminal filling defects to expedite emergency radiological workflows. Methods: A retrospective analysis was conducted on CTPA scans from multiple centers. The dataset was divided into a primary internal cohort ( n = 1,368) for model derivation and testing, alongside an independent external cohort ( n = 98) to assess generalizability. The diagnostic efficacy of the YOLOv11 architecture was quantified using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Additionally, gradient-weighted class activation mapping (Grad-CAM) was applied to map the spatial distribution of the model's focus, ensuring clinical transparency. Results: During internal testing, the proposed framework yielded an AUC of 0.777 [95% confidence interval (CI): 0.765–0.788], corresponding to a sensitivity of 74.53% and a specificity of 64.26%. When applied to the external cohort, the algorithm's discriminative ability remained consistent with an AUC of 0.778 (95% CI: 0.749–0.806). Notably, the external sensitivity reached 86.75% (specificity: 54.46%). Visual assessments via Grad-CAM saliency maps confirmed that the model accurately localized embolic occlusions within the complex pulmonary arterial tree. Conclusion: Utilizing the YOLOv11 architecture for automated CTPA analysis yields a highly sensitive and visually interpretable screening mechanism. This artificial intelligence-assisted approach holds substantial promise for reducing missed diagnoses and accelerating patient triage in acute clinical settings.
- 24 July 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1864916
Open AccessA deep learning model for the interpretable identification of pulmonary thromboembolism from computed tomography pulmonary angiography
Objective: The rapid identification of pulmonary thromboembolism (PTE) on computed tomography pulmonary angiography (CTPA) is vital but labor-intensive, often leading to diagnostic delays. We aimed to construct and evaluate a YOLOv11 object detection algorithm capable of automatically highlighting intraluminal filling defects to expedite emergency radiological workflows. Methods: A retrospective analysis was conducted on CTPA scans from multiple centers. The dataset was divided into a primary internal cohort ( n = 1,368) for model derivation and testing, alongside an independent external cohort ( n = 98) to assess generalizability. The diagnostic efficacy of the YOLOv11 architecture was quantified using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Additionally, gradient-weighted class activation mapping (Grad-CAM) was applied to map the spatial distribution of the model's focus, ensuring clinical transparency. Results: During internal testing, the proposed framework yielded an AUC of 0.777 [95% confidence interval (CI): 0.765–0.788], corresponding to a sensitivity of 74.53% and a specificity of 64.26%. When applied to the external cohort, the algorithm's discriminative ability remained consistent with an AUC of 0.778 (95% CI: 0.749–0.806). Notably, the external sensitivity reached 86.75% (specificity: 54.46%). Visual assessments via Grad-CAM saliency maps confirmed that the model accurately localized embolic occlusions within the complex pulmonary arterial tree. Conclusion: Utilizing the YOLOv11 architecture for automated CTPA analysis yields a highly sensitive and visually interpretable screening mechanism. This artificial intelligence-assisted approach holds substantial promise for reducing missed diagnoses and accelerating patient triage in acute clinical settings.
- Open Access
- 10 April 2026
- Published by Elsevier in eClinicalMedicine
- Vol. 94
Safety of paclitaxel-coated devices in patients with peripheral artery disease: an updated systematic review and meta-analysis of randomized controlled trials
- 10 April 2026
- Published by Elsevier in eClinicalMedicine
- Vol. 94
Open AccessSafety of paclitaxel-coated devices in patients with peripheral artery disease: an updated systematic review and meta-analysis of randomized controlled trials
- Open Access
- 26 August 2025
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 31
A Blended Interprofessional Education Program Enhances Healthcare Workers’ Knowledge, Attitudes, and Practices Regarding Venous Thromboembolism
Background: The prevention and management of venous thromboembolism (VTE) represent crucial issues within healthcare, as they are linked to patient safety and quality of care. As such, healthcare workers are expected to demonstrate certain levels of knowledge, attitudes, and practices (KAP) regarding VTE. This study evaluated the efficacy of an existing 5-year blended interprofessional education program (BIEP) designed to improve KAP regarding VTE at a university-affiliated hospital. Objective: To evaluate the BIEP’s effectiveness on enhancing KAP regarding VTE prevention and management. Methods: This single-center observational study was designed to assess changes in KAP regarding VTE before and after the implementation of a BIEP. These changes were evaluated via an expert-developed electronic questionnaire distributed to healthcare workers participating in the BIEP. Knowledge items were assessed in terms of accuracy, whereas attitude and practice items were assessed using a 5-point Likert scale, with higher scores indicating improvements in attitudes and practices. Results: Of 1817 questionnaires distributed, a total of 1145 healthcare workers completed the pre-training and post-training surveys. The average accuracy rate for knowledge-based questions increased from 36.9% before training to 50.4% after training ( P < 0.001). Attitude scores improved modestly (from 18.68 ± 5.76 to 19.41 ± 4.97; P = 0.011), as did practice scores (from 19.86 ± 3.88 to 20.37 ± 3.89; P = 0.003). Conclusions: The BIEP improved the KAP of healthcare workers regarding VTE. These findings emphasize the importance of continuous education in enhancing the quality of VTE management and provide a scientific basis for future educational interventions.
- 26 August 2025
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 31
Open AccessA Blended Interprofessional Education Program Enhances Healthcare Workers’ Knowledge, Attitudes, and Practices Regarding Venous Thromboembolism
Background: The prevention and management of venous thromboembolism (VTE) represent crucial issues within healthcare, as they are linked to patient safety and quality of care. As such, healthcare workers are expected to demonstrate certain levels of knowledge, attitudes, and practices (KAP) regarding VTE. This study evaluated the efficacy of an existing 5-year blended interprofessional education program (BIEP) designed to improve KAP regarding VTE at a university-affiliated hospital. Objective: To evaluate the BIEP’s effectiveness on enhancing KAP regarding VTE prevention and management. Methods: This single-center observational study was designed to assess changes in KAP regarding VTE before and after the implementation of a BIEP. These changes were evaluated via an expert-developed electronic questionnaire distributed to healthcare workers participating in the BIEP. Knowledge items were assessed in terms of accuracy, whereas attitude and practice items were assessed using a 5-point Likert scale, with higher scores indicating improvements in attitudes and practices. Results: Of 1817 questionnaires distributed, a total of 1145 healthcare workers completed the pre-training and post-training surveys. The average accuracy rate for knowledge-based questions increased from 36.9% before training to 50.4% after training ( P < 0.001). Attitude scores improved modestly (from 18.68 ± 5.76 to 19.41 ± 4.97; P = 0.011), as did practice scores (from 19.86 ± 3.88 to 20.37 ± 3.89; P = 0.003). Conclusions: The BIEP improved the KAP of healthcare workers regarding VTE. These findings emphasize the importance of continuous education in enhancing the quality of VTE management and provide a scientific basis for future educational interventions.
- 17 July 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 51 (2) , 1035-1045
A systematic review of cases of aortic penetration by inferior vena cava filters
Objective To assess the clinical presentation of aortic penetration by inferior vena cava (IVC) filters, as well as common management strategies and clinical outcomes. Methods A systematic search of the literature was conducted to identify studies pertaining to aortic penetration by IVC filters published between January 1967 and April 2025. Results A total of 35 reports regarding aortic penetration by IVC filters were identified, including a total of 53 patients and 11 types of IVC filters. The median time from filter placement to the diagnosis of aortic penetration was 5.0 years (interquartile range: 1.7, 8.0 years). Of the 53 patients, 28 (52.8%) were symptomatic, 19 (35.9%) were asymptomatic, and 6 (11.3%) had unknown symptomatology. The most frequently reported symptom was abdominal pain (30.2%). Fifteen patients were reported to have experienced one or more of the following complications: aortic pseudoaneurysm (n = 7), arterial thrombosis (n = 5), retroperitoneal hematoma (n = 4), arteriovenous fistula (n = 2), and aortic dissection (n = 1). Of the 53 patients, 36 (67.9%) underwent filter retrieval (endovascular retrieval, n = 24; surgical retrieval, n = 12), 9 (18.0%) underwent repair of the perforated aorta without filter removal, 6 (11.3%) received conservative management, and 2 (4.0%) died of retroperitoneal hematoma. Conclusions Aortic penetration by IVC filters is uncommon but potentially life-threatening. Symptomatic patients account for nearly half of all penetrations. For patients demonstrating concomitant penetration into adjacent tissues or visceral organs, surgical retrieval may provide the best option. In asymptomatic patients with no radiologically evident concomitant injuries, endovascular retrieval has been demonstrated to serve as a relatively safe and feasible alternative management strategy.
- 17 July 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 51 (2) , 1035-1045
A systematic review of cases of aortic penetration by inferior vena cava filters
Objective To assess the clinical presentation of aortic penetration by inferior vena cava (IVC) filters, as well as common management strategies and clinical outcomes. Methods A systematic search of the literature was conducted to identify studies pertaining to aortic penetration by IVC filters published between January 1967 and April 2025. Results A total of 35 reports regarding aortic penetration by IVC filters were identified, including a total of 53 patients and 11 types of IVC filters. The median time from filter placement to the diagnosis of aortic penetration was 5.0 years (interquartile range: 1.7, 8.0 years). Of the 53 patients, 28 (52.8%) were symptomatic, 19 (35.9%) were asymptomatic, and 6 (11.3%) had unknown symptomatology. The most frequently reported symptom was abdominal pain (30.2%). Fifteen patients were reported to have experienced one or more of the following complications: aortic pseudoaneurysm (n = 7), arterial thrombosis (n = 5), retroperitoneal hematoma (n = 4), arteriovenous fistula (n = 2), and aortic dissection (n = 1). Of the 53 patients, 36 (67.9%) underwent filter retrieval (endovascular retrieval, n = 24; surgical retrieval, n = 12), 9 (18.0%) underwent repair of the perforated aorta without filter removal, 6 (11.3%) received conservative management, and 2 (4.0%) died of retroperitoneal hematoma. Conclusions Aortic penetration by IVC filters is uncommon but potentially life-threatening. Symptomatic patients account for nearly half of all penetrations. For patients demonstrating concomitant penetration into adjacent tissues or visceral organs, surgical retrieval may provide the best option. In asymptomatic patients with no radiologically evident concomitant injuries, endovascular retrieval has been demonstrated to serve as a relatively safe and feasible alternative management strategy.
- Open Access
- 25 June 2025
- Published by Frontiers Media SA in Frontiers in Pharmacology
- Vol. 16, 1632205
Corrigendum: Paricalcitol alleviates intestinal ischemia-reperfusion injury via inhibition of the ATF4-CHOP pathway
Corrigendum on: Zhang J, Liu T, Xue T, Jia Z. Paricalcitol alleviates intestinal ischemiareperfusion injury via inhibition of the ATF4-CHOP pathway. Front Pharmacol. 2025;16:1529343. Published 2025Apr 3. doi:10.3389/fphar.2025.1529343 In the published article, there were errors in Figure 5C and Figure 6C. Due to Authors' oversight during figure preparation, the β-actin image that was originally intended for Figure 2C was mistakenly placed again in Figure 5C. Additionally, in Figure 6C, the TUNEL and DAPI staining images for the siATF4 group were incorrectly inserted. The corrected Figure 5 and Figure 6 and its caption appear below.The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.
- 25 June 2025
- Published by Frontiers Media SA in Frontiers in Pharmacology
- Vol. 16, 1632205
Open AccessCorrigendum: Paricalcitol alleviates intestinal ischemia-reperfusion injury via inhibition of the ATF4-CHOP pathway
Corrigendum on: Zhang J, Liu T, Xue T, Jia Z. Paricalcitol alleviates intestinal ischemiareperfusion injury via inhibition of the ATF4-CHOP pathway. Front Pharmacol. 2025;16:1529343. Published 2025Apr 3. doi:10.3389/fphar.2025.1529343 In the published article, there were errors in Figure 5C and Figure 6C. Due to Authors' oversight during figure preparation, the β-actin image that was originally intended for Figure 2C was mistakenly placed again in Figure 5C. Additionally, in Figure 6C, the TUNEL and DAPI staining images for the siATF4 group were incorrectly inserted. The corrected Figure 5 and Figure 6 and its caption appear below.The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.
- Open Access
- 10 May 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 13 (5) , 102259
Incidence, predictors, and clinical outcomes of thrombus propagation in patients with acute isolated calf muscle venous thrombosis
- 10 May 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 13 (5) , 102259
Open AccessIncidence, predictors, and clinical outcomes of thrombus propagation in patients with acute isolated calf muscle venous thrombosis
- 30 April 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (11) , 5552-5559
Efficacy and safety of renal artery embolization for blunt traumatic renal hemorrhage: a multicenter study
Objective To evaluate the efficacy and safety of renal artery embolization (RAE) for the management of blunt traumatic renal hemorrhage. Methods Patients with blunt traumatic renal hemorrhage treated with RAE across four hospitals from January 2018 to December 2024 were included in the study. Technical and clinical success rates, renal function preservation, side effects and complication were analyzed. Results In the 71 study patients, the technical success rate of RAE was 100%, and the clinical success rate was 93.0% (66/71). The mean RAE procedure time was 1.2 ± 0.5 h and which was increased with higher American Association for the Surgery of Trauma (AAST) grades, and significantly longer was required for higher AAST grade. The mean infarcted renal area was 38% (range, 15-80%). The average serum creatinine level pre- and 1, 3, 5 and 7 days post-RAE were 95.6 ± 47.1 µmol/L, 99.0 ± 44.3 µmol/L, 88.4 ± 31.7 µmol/L, 85.0 ± 27.5 µmol/L and 78.5 ± 41.1 µmol/L, respectively. Different embolic materials (coils vs. gelatin sponge particles) showed no significant differences in technical and clinical success rates but highlighted cost advantages for gelatin sponge particles (4003.4 ± 1381.9 vs. 1919.4 ± 345.7 CNY; P < 0.001). The most common side effect was fever (42.3%), while no RAE related major complications. Conclusion RAE is a highly effective and minimally invasive treatment for blunt traumatic renal hemorrhage, with significant success in hemostasis and renal function preservation. Gelatin sponge particles should be used as first line choice for RAE.
- 30 April 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (11) , 5552-5559
Efficacy and safety of renal artery embolization for blunt traumatic renal hemorrhage: a multicenter study
Objective To evaluate the efficacy and safety of renal artery embolization (RAE) for the management of blunt traumatic renal hemorrhage. Methods Patients with blunt traumatic renal hemorrhage treated with RAE across four hospitals from January 2018 to December 2024 were included in the study. Technical and clinical success rates, renal function preservation, side effects and complication were analyzed. Results In the 71 study patients, the technical success rate of RAE was 100%, and the clinical success rate was 93.0% (66/71). The mean RAE procedure time was 1.2 ± 0.5 h and which was increased with higher American Association for the Surgery of Trauma (AAST) grades, and significantly longer was required for higher AAST grade. The mean infarcted renal area was 38% (range, 15-80%). The average serum creatinine level pre- and 1, 3, 5 and 7 days post-RAE were 95.6 ± 47.1 µmol/L, 99.0 ± 44.3 µmol/L, 88.4 ± 31.7 µmol/L, 85.0 ± 27.5 µmol/L and 78.5 ± 41.1 µmol/L, respectively. Different embolic materials (coils vs. gelatin sponge particles) showed no significant differences in technical and clinical success rates but highlighted cost advantages for gelatin sponge particles (4003.4 ± 1381.9 vs. 1919.4 ± 345.7 CNY; P < 0.001). The most common side effect was fever (42.3%), while no RAE related major complications. Conclusion RAE is a highly effective and minimally invasive treatment for blunt traumatic renal hemorrhage, with significant success in hemostasis and renal function preservation. Gelatin sponge particles should be used as first line choice for RAE.