Mehdi Shahidi Zandi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mehdi Shahidi Zandi has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
S.M.A. Hosseini
4 shared publicationsA.H. Jafari
2 shared publicationsHamideh Asadollahzadeh
2 shared publicationsM. M. Foroughi
Department of Chemistry, Kerman Branch, Islamic Azad University, Kerman, Iran
2 shared publicationsM.J. Bahrami
2 shared publicationsM.R. Gholamhosseinzadeh
2 shared publications
Latest Publications
- 28 November 2022
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 100 (4)
Analysis of electrochemical current noise data arising from corrosion of Al alloy in a gel electrolyte by wavelet and recurrence methods
- 28 November 2022
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 100 (4)
Analysis of electrochemical current noise data arising from corrosion of Al alloy in a gel electrolyte by wavelet and recurrence methods
- Open Access
- 22 November 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 22, 107-125
Using of asymmetric cell to monitor corrosion performance of 304 austenitic stainless steel by electrochemical noise method
- 22 November 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 22, 107-125
Open AccessUsing of asymmetric cell to monitor corrosion performance of 304 austenitic stainless steel by electrochemical noise method
- 31 August 2022
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 99 (10)
The effect of Tetracycline drug as a green corrosion inhibitor for carbon steel in HCl media
- 31 August 2022
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 99 (10)
The effect of Tetracycline drug as a green corrosion inhibitor for carbon steel in HCl media
- 11 May 2022
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 99 (7)
Corrosion protection of carbon steel in acidic media by expired bupropion drug; experimental and theoretical study
- 11 May 2022
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 99 (7)
Corrosion protection of carbon steel in acidic media by expired bupropion drug; experimental and theoretical study
- 28 April 2022
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 286
Sensitive determination of hydroxylamine by using modified electrode by La2O3–Co3O4 nanocomposite and ionic liquid
- 28 April 2022
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 286
Sensitive determination of hydroxylamine by using modified electrode by La2O3–Co3O4 nanocomposite and ionic liquid
- 4 September 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (4) , 633-641
Evaluation of the localized corrosion on Mg electrode surface by electrochemical noise technique
The symmetrical and asymmetrical electrodes made of Mg were studied in 0.1‐M NaCl electrolyte adjusted at pH 12. The statistical and wavelet methods were employed for analyzing the electrochemical current noise (ECN) signals. The asymmetric configuration was used for electrochemical detection of filiform corrosion on Mg electrode. The real time scale of the dominant transients of the asymmetric electrodes was detected on the basis of the maximum peak in the SDPS plots. The SDPS values of the real time scale crystals of the ECN signals resulting from asymmetrical electrodes increased with the increase in immersion time due to the onset of filiform corrosion.
- 4 September 2020
- Published by Wiley in Materials and Corrosion
- Vol. 72 (4) , 633-641
Evaluation of the localized corrosion on Mg electrode surface by electrochemical noise technique
The symmetrical and asymmetrical electrodes made of Mg were studied in 0.1‐M NaCl electrolyte adjusted at pH 12. The statistical and wavelet methods were employed for analyzing the electrochemical current noise (ECN) signals. The asymmetric configuration was used for electrochemical detection of filiform corrosion on Mg electrode. The real time scale of the dominant transients of the asymmetric electrodes was detected on the basis of the maximum peak in the SDPS plots. The SDPS values of the real time scale crystals of the ECN signals resulting from asymmetrical electrodes increased with the increase in immersion time due to the onset of filiform corrosion.
- Open Access
- 1 July 2020
- Vol. 13 (3) , 155-165
Electrochemical Investigation of Meloxicam Drug as a Corrosion Inhibitor for Mild Steel in Hydrochloric and Sulfuric Acid Solutions
- 1 July 2020
- Vol. 13 (3) , 155-165
Open AccessElectrochemical Investigation of Meloxicam Drug as a Corrosion Inhibitor for Mild Steel in Hydrochloric and Sulfuric Acid Solutions
- Open Access
- 1 May 2020
- Vol. 13 (2) , 131-141
Influence of Electrodeposition Method, Solvent and Nanoparticle Concentration on Polypyrrole Coatings for Corrosion Protection of Mild Steel
- 1 May 2020
- Vol. 13 (2) , 131-141
Open AccessInfluence of Electrodeposition Method, Solvent and Nanoparticle Concentration on Polypyrrole Coatings for Corrosion Protection of Mild Steel
- 24 June 2019
- Published by Springer Nature in Iranian Polymer Journal
- Vol. 28 (7) , 577-585
Polypyrrole coatings for corrosion protection of Al alloy2024: influence of electrodeposition methods, solvents, and ZnO nanoparticle concentrations
- 24 June 2019
- Published by Springer Nature in Iranian Polymer Journal
- Vol. 28 (7) , 577-585
Polypyrrole coatings for corrosion protection of Al alloy2024: influence of electrodeposition methods, solvents, and ZnO nanoparticle concentrations
- 12 June 2019
- Published by Wiley in Materials and Corrosion
- Vol. 70 (11) , 1999-2008
Advantages of asymmetrical over symmetrical cells for detection of under deposit CO2 corrosion using electrochemical noise
Electrochemical noise (EN) measurements were done on symmetrical and asymmetrical cells after immersion in 3.5% NaCl solutions saturated with CO2 and containing different concentrations of sodium bicarbonate to get a better interpretation of the under‐deposit corrosion of mild steel. The symmetrical cell was constructed from two sand‐deposited electrodes and the asymmetrical cell was prepared from one sand‐deposited electrode and one bare electrode. The combination of the standard deviation of partial signal (SDPS) plots arising from wavelet analysis and recurrence plots for analyzing the EN signals obtained from symmetrical and asymmetrical cells confirmed the higher detective ability of the asymmetrical cells in comparison with the symmetrical cells for measuring the under‐deposit corrosion of mild steel. Both the SDPS and recurrence plots arising from symmetrical cells showed no significant change in the corrosion severity of the steel alloy with adding sodium bicarbonate. In contrast, the SDPS and recurrence plots of the asymmetrical cells proved that the corrosion severity decreased initially with adding the bicarbonate and thereafter remained constant with increasing the bicarbonate concentration. The optical microscopy images of the sand‐covered electrode surface confirmed the latter result.
- 12 June 2019
- Published by Wiley in Materials and Corrosion
- Vol. 70 (11) , 1999-2008
Advantages of asymmetrical over symmetrical cells for detection of under deposit CO2 corrosion using electrochemical noise
Electrochemical noise (EN) measurements were done on symmetrical and asymmetrical cells after immersion in 3.5% NaCl solutions saturated with CO2 and containing different concentrations of sodium bicarbonate to get a better interpretation of the under‐deposit corrosion of mild steel. The symmetrical cell was constructed from two sand‐deposited electrodes and the asymmetrical cell was prepared from one sand‐deposited electrode and one bare electrode. The combination of the standard deviation of partial signal (SDPS) plots arising from wavelet analysis and recurrence plots for analyzing the EN signals obtained from symmetrical and asymmetrical cells confirmed the higher detective ability of the asymmetrical cells in comparison with the symmetrical cells for measuring the under‐deposit corrosion of mild steel. Both the SDPS and recurrence plots arising from symmetrical cells showed no significant change in the corrosion severity of the steel alloy with adding sodium bicarbonate. In contrast, the SDPS and recurrence plots of the asymmetrical cells proved that the corrosion severity decreased initially with adding the bicarbonate and thereafter remained constant with increasing the bicarbonate concentration. The optical microscopy images of the sand‐covered electrode surface confirmed the latter result.