EREvan J. Ryer

Evan J. Ryer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Evan J. Ryer has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Centralized Digital Surveillance for Abdominal Aortic Aneurysm Detection, Longitudinal Tracking, and Management Within an Integrated Health System: Retrospective Cohort Study

    by Evan J Ryer, Gregory G Salzler, Matthew Goldfarb, Anthony J Lewis, Yatin B Mehta, Ian R Dinsmore, Tooraj Mirshahi, Elliot G Mitchell, Grant DeLong, James R Elmore

    Background: Incidental detection of abdominal aortic aneurysms (AAAs) has increased with widespread cross-sectional imaging, while traditional surveillance remains fragmented and clinician-dependent. Real-world descriptions of centralized digital surveillance programs combining structured electronic health record (EHR) queries with natural language processing (NLP) of radiology reports remain limited. Objective: This study aimed to describe the design, implementation, and operational performance of the System to Track Abnormalities of Importance Reliably (STAIR), a centralized digital surveillance program combining structured EHR queries, an internally developed NLP model, clinician referrals, and automated lost-to-follow-up detection to identify, track, and manage patients with AAAs across a large integrated health system. Methods: This retrospective cohort study included all patients enrolled in the STAIR AAA surveillance program from December 2022 through December 2024. Patients were identified via 4 pathways: an internally developed NLP model applied to radiology reports, EHR problem-list queries, clinician referrals, and automated lost-to-follow-up queries. All cases underwent standardized centralized clinical review, and surveillance intervals were assigned using guideline-informed institutional protocols. Administrative status and ongoing surveillance were assessed through April 2026. Outcomes were descriptive. Cohort integrity was evaluated against an independent, automated, computed tomography (CT)–based measurement system among patients with CT imaging. Results: A total of 8464 patients were enrolled (mean age 77.1, SD 8.8 y; male: n=6516, 77.0%; and White: n=83119, 8.2%). Identification was predominantly automated via problem-list queries (n=4994, 59.0%) and radiology NLP (n=2454, 29.0%), with clinician referral (n=592, 7.0%) and lost-to-follow-up queries (n=423, 5.0%). Following centralized review, most patients were assigned guideline-based duplex surveillance (biennial: 45.3%; 5-year: 9.5%); 20.6% were referred for vascular surgery evaluation, and another 20.6% had prior AAA repair at enrollment. Among all 8464 enrolled patients, 4188 (49.5%) remained under active surveillance as of April 2026, and 2709 (32.0%) had transitioned to management outside the health system. Duplex ultrasonography was the predominant surveillance imaging modality (6122/6951 patients, 88.1%); 351 elective AAA repairs were performed system-wide during the study period, including 260 in the enrolled cohort. Conclusions: In a large integrated health system, this centralized digital surveillance infrastructure was operationally feasible and supported large-scale, structured identification, guideline-based surveillance and management assignment, and documented administrative status through April 2026 for all 8464 enrolled patients, including those who could not be reached despite repeated outreach. These descriptive findings establish operational feasibility only and characterize a scalable, workflow-focused approach to population-level AAA surveillance and management that emphasizes structured clinical oversight rather than autonomous AI decision-making; clinical effectiveness is not demonstrated by this design.

  • Open Access

    Genetic Basis of Thoracic Aortic Aneurysms in a Large Unselected Clinical Population

    by Hannah S. Mirshahi, Jeremy S. Haley, Diane T. Smelser, Evan J. Ryer, James R. Elmore, David J. Carey

  • Abstract 564: Genetic Basis Of Thoracic Aortic Aneurysms In A Large Unselected Clinical Population

    by Hannah S Mirshahi, Jeremy S Haley, Diane T Smelser, Evan J Ryer, James R Elmore, David J Carey

  • Open Access

    Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Carotid Artery Using Computed Tomographic Angiography

    by Lucas J. Bitsko, Evan J. Ryer, Ellen P. Penn, Gregory G. Salzler, Matthew Major, Jeremy Irvan, James R. Elmore

    Duplex ultrasound (DUS) velocity measurement is the preferred method for evaluating carotid artery stenosis. However, velocity criteria based upon native carotid arteries may not apply to internal carotid artery stents. Previously, catheter-based angiography was used to determine DUS velocity criteria for in-stent restenosis (ISR), but conventional angiography is invasive and can be limited. This study sought to define duplex ultrasound velocity criteria for predicting internal carotid artery in-stent restenosis by correlating in-stent velocities with computed tomographic angiography (CTA) measurements of percent stenosis. A retrospective chart review was conducted on all patients who underwent internal carotid artery (ICA) stenting within our health system between January 2013 and February 2020. Thirty-eight surveillance DUS studies from 32 patients were found to have CTA performed within 30 days. Centerline reconstructions of internal carotid artery stents were created using Aquarius iNtuition software (TeraRecon, Durham, NC, USA). Two independent observers measured percent stenosis by three built-in methods. Stenotic areas were matched to DUS-measured peak systolic velocities (PSV) and end-diastolic velocities (EDV). Internal carotid artery PSV (stent) to common carotid artery (CCA) PSV ratios (ICA/CCA) were calculated, and receiver operating characteristic (ROC) curves were generated. The optimal DUS velocity criteria in the stented ICA were determined by maximizing Youden’s index. Mean vessel diameter measurement of percent stenosis resulted in the most accurate model for all DUS velocity parameters (PSV, EDV, and ICA/CCA ratio) and was used for threshold determinations (area under the receiver operating characteristics (AUROC): 0.99, 0.96, and 0.96, respectively). A PSV cutoff of 240 cm/s for ≥60% ISR resulted in the highest Youden’s index (97%) with 100% sensitivity and 97% specificity. Secondary DUS parameters included an EDV ≥50 cm/s (Youden’s index 84%) and an ICA/CCA ratio ≥ 2.2 (Youden’s index 91%). Velocity criteria to predict internal carotid artery ISR is needed to inform decisions for possible reintervention. Using CTA, we found that a PSV ≥240 cm/s on carotid DUS can predict ≥60% ISR with high sensitivity and specificity. This value can be used as an alternative to current velocity criteria based on native carotid arteries. However, the optimal thresholds for EDV and ICA/CCA ratio were similar to native carotid arteries.


  • Open Access

    Outcomes of transcaval endoleak embolization via laser fenestration of the inferior vena cava following endovascular abdominal aortic aneurysm repair

    by Evan J. Ryer, Ellen P. Penn, Lucas J. Bitsko, Neal T. Cooper, Amber S. Hussain, Gregory G. Salzler, James R. Elmore


  • Open Access

    Identifying Risk Factors for Complications During Exposure for Anterior Lumbar Interbody Fusion

    by William G Wert, William Sellers, David Mariner, Melissa Obmann, Boyoung Song, Evan J. Ryer, Shivprasad Nikam

    An anterior approach to lumbar interbody fusion is a widely utilized method of access to the lumbar spine. Due to the potential for vascular complications with spine exposure, vascular surgeons are frequently included in the care of these patients as part of a team-based approach. Identifying risk factors for such complications is difficult and not well-defined in the literature. In this investigation, we evaluate the potential risk factors for complications during anterior lumbar inter-body fusion (ALIF). This is a retrospective review of 106 patients who underwent ALIF at a single institution between May 1, 2007, and April 30, 2017. Patients were identified through operating room case logs and Current Procedural Terminology (CPT) codes correlating with ALIF. Vascular surgeons performed all anterior exposures. Patient demographics and data regarding their surgical care and postoperative course were obtained from a review of operative and progress notes in the electronic medical record. Statistical methods employed included a t-test for normally distributed data and the Wilcoxon rank-sum test for non-normally distributed data. Categorical variables were compared using Fisher’s exact and chi-square tests. A logistic regression model was applied to predict complications by controlling other significant covariates. Of the 106 patients included in this analysis, 16 patients experienced a defined complication, giving an overall complication rate of 15%. Patients with complications were more likely to be of male gender (n=11, P=0.016), with older average age (54.6, P=0.017), with higher estimated blood loss, with higher use of blood products, and with higher use of cell-saver. A venous injury was the most common complication (n=11, 10.4%); ileus and nerve injury were the next most common (n=3, 2.8%). The 30-day mortality was 0%. Male gender demonstrated an odds ratio of 3.78 (P=0 .034) in a logistic regression model after adjusting for age and blood products. Overall complication rates were comparable to those in the published literature and male gender was identified as a predictor for risk of complications in those undergoing ALIF. This is the first study to identify male sex as a risk factor for complications following ALIF. The results of this study will hopefully guide future studies in gaining more insight into the predictors of complications in larger series.


  • Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Superior Mesenteric Artery

    by Jessica Green, Evan Ryer, Nicholas Borden, Bilal Ali, Robert Garvin, Andrew Yang, Ammar Hashmi, Gregory Salzler, James Elmore


  • Outcome of rectus femoris muscle flaps performed by vascular surgeons for the management of complex groin wounds after femoral artery reconstructions

    by Evan J. Ryer, Robert P. Garvin, Ravi N. Kapadia, Benjamin D. Jorgensen, Jessica O. Green, Marcus Fluck, Ksenia Orlova, Matthew C. Cindric, James R. Elmore


  • Aortoenteric Fistula through a Thrombosed Graft

    by Mahdi Malekpour, Jeremy L. Irvan, Ammar Hashmi, Kenneth A. Widom, Evan J. Ryer

    BACKGROUND Aortoenteric fistula is a dreadful and uncommon complication after abdominal aortic aneurysm repair. Continuous friction against the intestine and the aortic graft along with local inflammation is thought to be the major cause of aortoenteric fistula formation, although it is unexpected to have fistula formation with a thrombosed aortic graft. CASE REPORT Here, we report a case of an aortoenteric fistula between a thrombosed aortoiliac bypass graft and the duodenum in a 75-year-old male patient who presented with a 2-month history of melena. In this case, the aortoduodenal fistula was repaired with excision of the aortic graft, proximal and distal oversewing of the aorta, omental flap coverage, pyloric exclusion and loop gastrojejunostomy creation. CONCLUSIONS An aortoenteric fistula can form through a thrombosed graft. Since this is not an expected route of fistula formation, there may be a delay in identification.


  • The Value of Surgical Graduate Medical Education (GME) Programs Within An Integrated Health Care System

    by Claire I. Lauer, Mohsen M. Shabahang, Brian Restivo, Samantha Lane, Sarah Hayek, James Dove, Halle B. Ellison, Erin Pica, Evan J. Ryer