Jan Peter Thomas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jan Peter Thomas has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Stefan Dazert
Department of Otolaryngology, Head and Neck Surgery, Katholisches Klinikum, Ruhr University Bochum, Bochum, Germany
10 shared publications- Christiane Völter
Ruhr-Universität Bochum, Katholisches Klinikum Bochum - St. Elisabeth-Hospital Bochum, Nordrhein-Westfalen, Germany
6 shared publications Christiane Voelter
Department of Otolaryngology, Head and Neck Surgery, Katholisches Klinikum, Ruhr University Bochum, Bochum, Germany
4 shared publications- Christoph Berger
Division of Infectious Diseases and Hospital Epidemiology, Children’s Research Center, University Children’s Hospital Zurich, University of Zurich, Zurich, Switzerland
4 shared publications - Johannes Forster
Institut für Hygiene und Mikrobiologie Julius‐Maximilians‐Universität Würzburg Würzburg Germany
4 shared publications - Johannes Liese
Department of Paediatrics, Division of Paediatric Infectious Diseases, University Hospital of Wuerzburg, Würzburg, Germany
4 shared publications
Latest Publications
- 1 January 2026
- Published by Georg Thieme Verlag KG
Infektiöse Rhinitis
- 1 January 2026
- Published by Georg Thieme Verlag KG
Akute Sinusitis
- 1 January 2026
- Published by Georg Thieme Verlag KG
Präseptale Zellulitis und (postseptale) Orbitaphlegmone
- 1 January 2026
- Published by Georg Thieme Verlag KG
Präseptale Zellulitis und (postseptale) Orbitaphlegmone
- Open Access
- 14 September 2023
- Published by Frontiers Media SA in Frontiers in Aging Neuroscience
- Vol. 15, 1220184
Longitudinal trajectories of memory among middle-aged and older people with hearing loss: the influence of cochlear implant use on cognitive functioning
Introduction: Cochlear implants (CI) are the gold standard intervention for severe to profound hearing loss, a known modifiable risk factor for dementia. However, it remains unknown whether CI use might prevent the age-related cognitive decline. Recent studies are encouraging but are limited, mainly by short follow-up periods and, for ethical reasons, lack of appropriate control groups. Further, as age-related cognitive decline is multifaceted and not linear, other statistical approaches have to be evaluated.Materials and methods: Immediate and delayed recall as measures of cognitive function were assessed in 75 newly implanted CI users (mean age 65.41 years ± 9.19) for up to 5 years (mean 4.5 ± 0.5) of CI use and compared to 8,077 subjects of the same age range from two longitudinal cohort studies, the Health and Retirement Study (HRS) and the English Longitudinal Study of Aging (ELSA). Linear and quadratic changes in cognitive trajectories were analyzed in detail using mixed growth models, considering possible confounders.Results: For CI users, the linear time slope showed a significant improvement in the specific domains (recall and delayed recall) over time. The quadratic time slope clearly indicated that the predicted change after CI provision followed an inverted U-shape with a predicted decline 2 years after CI provision. In the hearing-impaired group, a significant decline over time was found, with steeper declines early on and the tendency to flatten out in the follow-up.Conclusion: Cochlear implant use seems to boost cognitive trajectories in the first years after implantation. However, long-term prevention of dementia seems to need far more than restoration of hearing loss.
- 14 September 2023
- Published by Frontiers Media SA in Frontiers in Aging Neuroscience
- Vol. 15, 1220184
Open AccessLongitudinal trajectories of memory among middle-aged and older people with hearing loss: the influence of cochlear implant use on cognitive functioning
Introduction: Cochlear implants (CI) are the gold standard intervention for severe to profound hearing loss, a known modifiable risk factor for dementia. However, it remains unknown whether CI use might prevent the age-related cognitive decline. Recent studies are encouraging but are limited, mainly by short follow-up periods and, for ethical reasons, lack of appropriate control groups. Further, as age-related cognitive decline is multifaceted and not linear, other statistical approaches have to be evaluated.Materials and methods: Immediate and delayed recall as measures of cognitive function were assessed in 75 newly implanted CI users (mean age 65.41 years ± 9.19) for up to 5 years (mean 4.5 ± 0.5) of CI use and compared to 8,077 subjects of the same age range from two longitudinal cohort studies, the Health and Retirement Study (HRS) and the English Longitudinal Study of Aging (ELSA). Linear and quadratic changes in cognitive trajectories were analyzed in detail using mixed growth models, considering possible confounders.Results: For CI users, the linear time slope showed a significant improvement in the specific domains (recall and delayed recall) over time. The quadratic time slope clearly indicated that the predicted change after CI provision followed an inverted U-shape with a predicted decline 2 years after CI provision. In the hearing-impaired group, a significant decline over time was found, with steeper declines early on and the tendency to flatten out in the follow-up.Conclusion: Cochlear implant use seems to boost cognitive trajectories in the first years after implantation. However, long-term prevention of dementia seems to need far more than restoration of hearing loss.
- Open Access
- 4 April 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 633
Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection.
- 4 April 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 633
Open AccessIntra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection.
- 19 May 2022
- Published by Springer Nature
- p. 279-280
Dortmund: St. Johannes Hospital
- Open Access
- 9 May 2022
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 27 (5) , 356-367
Poor Performer: A Distinct Entity in Cochlear Implant Users?
Introduction: Several factors are known to influence speech perception in cochlear implant (CI) users. To date, the underlying mechanisms have not yet been fully clarified. Although many CI users achieve a high level of speech perception, a small percentage of patients does not or only slightly benefit from the CI (poor performer, PP). In a previous study, PP showed significantly poorer results on nonauditory-based cognitive and linguistic tests than CI users with a very high level of speech understanding (star performer, SP). We now investigate if PP also differs from the CI user with an average performance (average performer, AP) in cognitive and linguistic performance. Methods: Seventeen adult postlingually deafened CI users with speech perception scores in quiet of 55 (9.32) % (AP) on the German Freiburg monosyllabic speech test at 65 dB underwent neurocognitive (attention, working memory, short- and long-term memory, verbal fluency, inhibition) and linguistic testing (word retrieval, lexical decision, phonological input lexicon). The results were compared to the performance of 15 PP (speech perception score of 15 [11.80] %) and 19 SP (speech perception score of 80 [4.85] %). For statistical analysis, U-Test and discrimination analysis have been done. Results: Significant differences between PP and AP were observed on linguistic tests, in Rapid Automatized Naming (RAN: p = 0.0026), lexical decision (LexDec: p = 0.026), phonological input lexicon (LEMO: p = 0.0085), and understanding of incomplete words (TRT: p = 0.0024). AP also had significantly better neurocognitive results than PP in the domains of attention (M3: p = 0.009) and working memory (OSPAN: p = 0.041; RST: p = 0.015) but not in delayed recall (delayed recall: p = 0.22), verbal fluency (verbal fluency: p = 0.084), and inhibition (Flanker: p = 0.35). In contrast, no differences were found hereby between AP and SP. Based on the TRT and the RAN, AP and PP could be separated in 100%. Discussion: The results indicate that PP constitute a distinct entity of CI users that differs even in nonauditory abilities from CI users with an average speech perception, especially with regard to rapid word retrieval either due to reduced phonological abilities or limited storage. Further studies should investigate if improved word retrieval by increased phonological and semantic training results in better speech perception in these CI users.
- 9 May 2022
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 27 (5) , 356-367
Open AccessPoor Performer: A Distinct Entity in Cochlear Implant Users?
Introduction: Several factors are known to influence speech perception in cochlear implant (CI) users. To date, the underlying mechanisms have not yet been fully clarified. Although many CI users achieve a high level of speech perception, a small percentage of patients does not or only slightly benefit from the CI (poor performer, PP). In a previous study, PP showed significantly poorer results on nonauditory-based cognitive and linguistic tests than CI users with a very high level of speech understanding (star performer, SP). We now investigate if PP also differs from the CI user with an average performance (average performer, AP) in cognitive and linguistic performance. Methods: Seventeen adult postlingually deafened CI users with speech perception scores in quiet of 55 (9.32) % (AP) on the German Freiburg monosyllabic speech test at 65 dB underwent neurocognitive (attention, working memory, short- and long-term memory, verbal fluency, inhibition) and linguistic testing (word retrieval, lexical decision, phonological input lexicon). The results were compared to the performance of 15 PP (speech perception score of 15 [11.80] %) and 19 SP (speech perception score of 80 [4.85] %). For statistical analysis, U-Test and discrimination analysis have been done. Results: Significant differences between PP and AP were observed on linguistic tests, in Rapid Automatized Naming (RAN: p = 0.0026), lexical decision (LexDec: p = 0.026), phonological input lexicon (LEMO: p = 0.0085), and understanding of incomplete words (TRT: p = 0.0024). AP also had significantly better neurocognitive results than PP in the domains of attention (M3: p = 0.009) and working memory (OSPAN: p = 0.041; RST: p = 0.015) but not in delayed recall (delayed recall: p = 0.22), verbal fluency (verbal fluency: p = 0.084), and inhibition (Flanker: p = 0.35). In contrast, no differences were found hereby between AP and SP. Based on the TRT and the RAN, AP and PP could be separated in 100%. Discussion: The results indicate that PP constitute a distinct entity of CI users that differs even in nonauditory abilities from CI users with an average speech perception, especially with regard to rapid word retrieval either due to reduced phonological abilities or limited storage. Further studies should investigate if improved word retrieval by increased phonological and semantic training results in better speech perception in these CI users.
- 8 October 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (12) , 5111-5112
For each hypothesis on the aetiology of Beethoven’s hearing disorder, there remain pro’s and con’s
- 8 October 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (12) , 5111-5112
For each hypothesis on the aetiology of Beethoven’s hearing disorder, there remain pro’s and con’s
- 7 September 2021
- Published by Springer Nature in Zeitschrift für Gerontologie und Geriatrie
- Vol. 54 (6) , 611-620
Wie das Gehirn die Welt im Alter mit allen Sinnen wahrnimmt
- 7 September 2021
- Published by Springer Nature in Zeitschrift für Gerontologie und Geriatrie
- Vol. 54 (6) , 611-620
Wie das Gehirn die Welt im Alter mit allen Sinnen wahrnimmt