Paul Schalch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul Schalch has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Michael Friedman
Section of Head and Neck Surgery, Department of Otolaryngology and Bronchoesophagology, Rush-Presbyterian-St. Luke's Medical Center, Chicago, Illinois, USA
6 shared publicationsMauricio Di Silvio
5 shared publications- Michael Friedman
Rush University Medical Center, Chicago, Illinois, USA
3 shared publications Sandro Esperante
3 shared publicationsBrian J. Wong
2 shared publicationsDeborah Varela
2 shared publications
Latest Publications
- Open Access
- 11 December 2021
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 7 (1) , 43-46
Particle aerosolization with energy devices: A comparative study
Objective To compare the degree of particle aerosolization with the use of several energy devices used in tonsillectomy and other common upper airway procedures. Methods Three different energy devices were measured. These included (a) monopolar electrocautery, (b) bipolar electrocautery, and (c) thermal welding device (TWD). Each device was applied to fresh cadaveric cow tongue and porcine nose. Aerosolized particles produced by these devices were measured using a calibrated electronic particle counter. Measurements were recorded over the course of 3 minutes. Particle sizes were measured at 0.3, 0.5, 1.0, 5, and 10 μm. Results In comparing types of tissues and particle sizes, TWD had the lowest aerosolizing burden among the three devices. By analyzing the highest particle value of TWD against both monopolar and bipolar, monopolar electrocautery proved to have the highest aerosolization exposure with statistical significance at 0.5 and 10 μm. No statistical significance was found when comparing TWD against monopolar electrocautery. Discussion Our study demonstrates there is a difference in aerosolization burden dependent on the type of device utilized. TWD proved to have the lowest burden whereas monopolar electrocautery had the highest. Conclusion TWD produces less aerosolization than conventional monopolar electrocautery when cauterizing or ablating tissue in an experimental setting. The degree of aerosolization was comparable to bipolar electrocautery. Level of Evidence 2.
- 11 December 2021
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 7 (1) , 43-46
Open AccessParticle aerosolization with energy devices: A comparative study
Objective To compare the degree of particle aerosolization with the use of several energy devices used in tonsillectomy and other common upper airway procedures. Methods Three different energy devices were measured. These included (a) monopolar electrocautery, (b) bipolar electrocautery, and (c) thermal welding device (TWD). Each device was applied to fresh cadaveric cow tongue and porcine nose. Aerosolized particles produced by these devices were measured using a calibrated electronic particle counter. Measurements were recorded over the course of 3 minutes. Particle sizes were measured at 0.3, 0.5, 1.0, 5, and 10 μm. Results In comparing types of tissues and particle sizes, TWD had the lowest aerosolizing burden among the three devices. By analyzing the highest particle value of TWD against both monopolar and bipolar, monopolar electrocautery proved to have the highest aerosolization exposure with statistical significance at 0.5 and 10 μm. No statistical significance was found when comparing TWD against monopolar electrocautery. Discussion Our study demonstrates there is a difference in aerosolization burden dependent on the type of device utilized. TWD proved to have the lowest burden whereas monopolar electrocautery had the highest. Conclusion TWD produces less aerosolization than conventional monopolar electrocautery when cauterizing or ablating tissue in an experimental setting. The degree of aerosolization was comparable to bipolar electrocautery. Level of Evidence 2.
- 1 September 2009
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 141 (3) , P221-P222
SP402 – Respiratory epithelial adenomatoid hamartomas (READ)
- 1 September 2009
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 141 (3) , P221-P222
SP402 – Respiratory epithelial adenomatoid hamartomas (READ)
- 1 September 2009
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 141 (3) , 408-412
The Macroscopic and Microscopic Effects of Radiofrequency Injury in the Porcine Tongue
OBJECTIVE: Current treatment protocols for obstructive sleep apnea/hypopnea syndrome with radiofrequency ablation of the base of the tongue are empiric. Injecting local anesthetics and saline into the treatment site is believed to shorten treatment duration and improve results. Our objective is to compare lesions at different energy levels, both macroscopically and histologically, and to determine if electrolyte solution injection results in a larger lesion.STUDY DESIGN: A prospective, experimental animal study.SETTING: University‐affiliated institution.SUBJECTS AND METHODS: Five pigs each received four treatments on the right and four on the left side of the tongue. Three of four treatments were applied sequentially by increasing length of exposure (15, 30, or 60 seconds), and the fourth was conducted over 15 seconds after injecting 1 cc of a 1:1 local anesthetic‐saline solution into the treatment site. The animals were recovered for three days and then sacrificed. Macroscopic measurements for each lesion were analyzed, and histological comparison was performed.RESULTS: The average volume of the lesions was 57.36, 65.18, and 60.50 mm3 for treatment durations of 60, 30, and 15 seconds, respectively, and there was no significant difference. Lesion volume at sites where anesthetic‐saline was injected had a mean volume of 36.72 mm3. Paired comparison against the three treatment durations revealed significantly smaller lesion volume size (P = 0.0041, 0.0007, 0.0047, respectively).CONCLUSION: The lesions created with radiofrequency energy were consistent and predictable. The volumes of the lesions did not differ significantly with regard to different energy levels. The lesion was significantly smaller after injection of anestheticsaline at the treatment site.
- 1 September 2009
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 141 (3) , 408-412
The Macroscopic and Microscopic Effects of Radiofrequency Injury in the Porcine Tongue
OBJECTIVE: Current treatment protocols for obstructive sleep apnea/hypopnea syndrome with radiofrequency ablation of the base of the tongue are empiric. Injecting local anesthetics and saline into the treatment site is believed to shorten treatment duration and improve results. Our objective is to compare lesions at different energy levels, both macroscopically and histologically, and to determine if electrolyte solution injection results in a larger lesion.STUDY DESIGN: A prospective, experimental animal study.SETTING: University‐affiliated institution.SUBJECTS AND METHODS: Five pigs each received four treatments on the right and four on the left side of the tongue. Three of four treatments were applied sequentially by increasing length of exposure (15, 30, or 60 seconds), and the fourth was conducted over 15 seconds after injecting 1 cc of a 1:1 local anesthetic‐saline solution into the treatment site. The animals were recovered for three days and then sacrificed. Macroscopic measurements for each lesion were analyzed, and histological comparison was performed.RESULTS: The average volume of the lesions was 57.36, 65.18, and 60.50 mm3 for treatment durations of 60, 30, and 15 seconds, respectively, and there was no significant difference. Lesion volume at sites where anesthetic‐saline was injected had a mean volume of 36.72 mm3. Paired comparison against the three treatment durations revealed significantly smaller lesion volume size (P = 0.0041, 0.0007, 0.0047, respectively).CONCLUSION: The lesions created with radiofrequency energy were consistent and predictable. The volumes of the lesions did not differ significantly with regard to different energy levels. The lesion was significantly smaller after injection of anestheticsaline at the treatment site.
- 1 September 2009
- Published by Elsevier in Acta Otorrinolaringológica Española
- Vol. 60 (5) , 357-363
Aplicaciones de la tomografía de coherencia óptica en otorrinolaringología
- 1 September 2009
- Published by Elsevier in Acta Otorrinolaringológica Española
- Vol. 60 (5) , 357-363
Aplicaciones de la tomografía de coherencia óptica en otorrinolaringología
- 1 September 2009
- Published by Elsevier in Acta Otorrinolaringologica (English Edition)
- Vol. 60 (5) , 357-363
Optical coherence tomography applications in otolaryngology
- 1 September 2009
- Published by Elsevier in Acta Otorrinolaringologica (English Edition)
- Vol. 60 (5) , 357-363
Optical coherence tomography applications in otolaryngology
- 1 March 2008
- Published by SAGE Publications in American Journal of Rhinology
- Vol. 22 (2) , 204-209
Functional Endoscopic Dilatation of the Sinuses: Patient Satisfaction, Postoperative Pain, and Cost
Background: The purpose of this study was to determine how functional endoscopic dilatation of the sinuses (FEDS) compares with functional endoscopic sinus surgery (FESS) in a select group of patients with respect to (1) elimination of symptoms, (2) patient satisfaction, (3) postoperative narcotic use, and (4) cost. A retrospective study was performed of 70 patients with chronic rhinosinusitis who underwent FEDS or FESS as primary or revision treatment. Methods: Symptoms and satisfaction based on the Sino-Nasal Outcome Test (SNOT-20) questionnaires and global patient assessment, postoperative narcotic use, and costs were compared after 3-month follow-up. Results: SNOT-20 change scores indicated that both FEDS and FESS had clinically meaningful treatment responses. Patient satisfaction was higher and postoperative narcotics usage was less with FEDS. The cost for primary procedures was similar, whereas the cost for revision surgery using FEDS was considerably less. Turbinate lateralization and scarring was more common in the FEDS group, particularly early in the study. The incidence of recurrent sinus infections during the follow-up period was similar for both groups. Only one patient in the FEDS group required a repeat intervention within the short-term follow-up period. Conclusion: Both FEDS and FESS resulted in significant improvement in SNOT-20 scores for selected patients with mild disease. Patient satisfaction and postoperative narcotic use of FEDS compare favorably with FESS. Cost of FEDS was comparable with FESS for primary procedures but was less than FESS for revision procedures. Long-term efficacy and final cost of FEDS remain to be addressed, taking into account the need for revision procedures after initial FEDS, by means of long-term studies and objective outcome measures.
- 1 March 2008
- Published by SAGE Publications in American Journal of Rhinology
- Vol. 22 (2) , 204-209
Functional Endoscopic Dilatation of the Sinuses: Patient Satisfaction, Postoperative Pain, and Cost
Background: The purpose of this study was to determine how functional endoscopic dilatation of the sinuses (FEDS) compares with functional endoscopic sinus surgery (FESS) in a select group of patients with respect to (1) elimination of symptoms, (2) patient satisfaction, (3) postoperative narcotic use, and (4) cost. A retrospective study was performed of 70 patients with chronic rhinosinusitis who underwent FEDS or FESS as primary or revision treatment. Methods: Symptoms and satisfaction based on the Sino-Nasal Outcome Test (SNOT-20) questionnaires and global patient assessment, postoperative narcotic use, and costs were compared after 3-month follow-up. Results: SNOT-20 change scores indicated that both FEDS and FESS had clinically meaningful treatment responses. Patient satisfaction was higher and postoperative narcotics usage was less with FEDS. The cost for primary procedures was similar, whereas the cost for revision surgery using FEDS was considerably less. Turbinate lateralization and scarring was more common in the FEDS group, particularly early in the study. The incidence of recurrent sinus infections during the follow-up period was similar for both groups. Only one patient in the FEDS group required a repeat intervention within the short-term follow-up period. Conclusion: Both FEDS and FESS resulted in significant improvement in SNOT-20 scores for selected patients with mild disease. Patient satisfaction and postoperative narcotic use of FEDS compare favorably with FESS. Cost of FEDS was comparable with FESS for primary procedures but was less than FESS for revision procedures. Long-term efficacy and final cost of FEDS remain to be addressed, taking into account the need for revision procedures after initial FEDS, by means of long-term studies and objective outcome measures.
- 1 February 2008
- Published by Wiley in The Laryngoscope
- Vol. 118 (2) , 335-338
Middle Turbinate Medialization With Bovine Serum Albumin Tissue Adhesive (BioGlue)
Middle turbinate (MT) medialization without resection is an approach designed to both preserve the MT and prevent lateralization, which may cause obstruction of the outflow of the ethmoid, maxillary, and frontal sinuses after endoscopic sinus surgery. Many techniques for medialization have been described. We present a quick and easy technique that involves using the microdebrider to create small areas of denuded mucosa on opposite surfaces of the MT and the nasal septum followed by an application of a bovine serum albumin tissue adhesive to promote the formation of controlled synechiae without the need for nasal packing.
- 1 February 2008
- Published by Wiley in The Laryngoscope
- Vol. 118 (2) , 335-338
Middle Turbinate Medialization With Bovine Serum Albumin Tissue Adhesive (BioGlue)
Middle turbinate (MT) medialization without resection is an approach designed to both preserve the MT and prevent lateralization, which may cause obstruction of the outflow of the ethmoid, maxillary, and frontal sinuses after endoscopic sinus surgery. Many techniques for medialization have been described. We present a quick and easy technique that involves using the microdebrider to create small areas of denuded mucosa on opposite surfaces of the MT and the nasal septum followed by an application of a bovine serum albumin tissue adhesive to promote the formation of controlled synechiae without the need for nasal packing.
- 31 December 2007
- Published by Elsevier in Operative Techniques in Otolaryngology-Head and Neck Surgery
- Vol. 18 (4) , 324-328
Upper esophageal pH monitoring: Transnasal placement of the Bravo wireless capsule system
- 31 December 2007
- Published by Elsevier in Operative Techniques in Otolaryngology-Head and Neck Surgery
- Vol. 18 (4) , 324-328
Upper esophageal pH monitoring: Transnasal placement of the Bravo wireless capsule system
- 31 December 2007
- Published by Elsevier in Operative Techniques in Otolaryngology-Head and Neck Surgery
- Vol. 18 (4) , 307-309
Middle turbinate medialization with bovine serum albumin tissue adhesive (BioGlue)
- 31 December 2007
- Published by Elsevier in Operative Techniques in Otolaryngology-Head and Neck Surgery
- Vol. 18 (4) , 307-309
Middle turbinate medialization with bovine serum albumin tissue adhesive (BioGlue)