Martin Sandau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Martin Sandau has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Erik Bruun Simonsen
University of Copenhagen
3 shared publications - Henrik Aanæs
Technical University of Denmark
3 shared publications - Thomas Baltzer Moeslund
Aalborg University, Aalborg, Denmark
3 shared publications - Tine Alkjær
Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark
3 shared publications Karl E. Jensen
Department of Radiology, Rigshospitalet, Blegdamsvej 9, DK-2100, Copenhagen, Denmark
2 shared publicationsRikke V. Heimbürger
Department of Forensic Medicine, University of Copenhagen, Frederik V's Vej 11, DK-2100, Copenhagen, Denmark
2 shared publications
Latest Publications
- 6 January 2016
- Published by Wiley in Journal of Forensic Sciences
- Vol. 61 (3) , 637-648
Reliable Gait Recognition Using 3D Reconstructions and Random Forests – An Anthropometric Approach
Photogrammetric measurements of bodily dimensions and analysis of gait patterns inCCTVare important tools in forensic investigations but accurate extraction of the measurements are challenging. This study tested whether manual annotation of the joint centers on 3D reconstructions could provide reliable recognition. Sixteen participants performed normal walking where 3D reconstructions were obtained continually. Segment lengths and kinematics from the extremities were manually extracted by eight expert observers. The results showed that all the participants were recognized, assuming the same expert annotated the data. Recognition based on data annotated by different experts was less reliable achieving 72.6% correct recognitions as some parameters were heavily affected by interobserver variability. This study verified that 3D reconstructions are feasible for forensic gait analysis as an improved alternative to conventionalCCTV. However, further studies are needed to account for the use of different clothing, field conditions, etc.
- 6 January 2016
- Published by Wiley in Journal of Forensic Sciences
- Vol. 61 (3) , 637-648
Reliable Gait Recognition Using 3D Reconstructions and Random Forests – An Anthropometric Approach
Photogrammetric measurements of bodily dimensions and analysis of gait patterns inCCTVare important tools in forensic investigations but accurate extraction of the measurements are challenging. This study tested whether manual annotation of the joint centers on 3D reconstructions could provide reliable recognition. Sixteen participants performed normal walking where 3D reconstructions were obtained continually. Segment lengths and kinematics from the extremities were manually extracted by eight expert observers. The results showed that all the participants were recognized, assuming the same expert annotated the data. Recognition based on data annotated by different experts was less reliable achieving 72.6% correct recognitions as some parameters were heavily affected by interobserver variability. This study verified that 3D reconstructions are feasible for forensic gait analysis as an improved alternative to conventionalCCTV. However, further studies are needed to account for the use of different clothing, field conditions, etc.
- 28 August 2015
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (10) , 948-955
New equations to calculate 3D joint centres in the lower extremities
Biomechanical movement analysis in 3D requires estimation of joint centres in the lower extremities and this estimation is based on extrapolation from markers placed on anatomical landmarks. The purpose of the present study was to quantify the accuracy of three established set of equations and provide new improved equations to predict the joint centre locations. The 'true' joint centres of the knee and ankle joint were obtained in vivo by MRI scans on 10 male subjects whereas the 'true' hip joint centre was obtained in 10 male and 10 female cadavers by CT scans. For the hip joint the errors ranged from 26.7 (8.9) to 29.6 (7.5) mm, for the knee joint 5.8 (3.1) to 22.6 (3.3) mm and for the ankle joint 14.4 (2.2) to 27.0 (4.6) mm. This differed significantly from the improved equations by which the error for the hip joint ranged from 8.2 (3.6) to 11.6 (5.6) mm, for the knee joint from 2.9 (2.1) to 4.7 (2.5) mm and for the ankle joint from 3.4 (1.3) to 4.1 (2.0) mm. The coefficients in the new hip joint equations differed significantly between sexes. This difference depends on anatomical differences of the male and female pelvis.
- 28 August 2015
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (10) , 948-955
New equations to calculate 3D joint centres in the lower extremities
Biomechanical movement analysis in 3D requires estimation of joint centres in the lower extremities and this estimation is based on extrapolation from markers placed on anatomical landmarks. The purpose of the present study was to quantify the accuracy of three established set of equations and provide new improved equations to predict the joint centre locations. The 'true' joint centres of the knee and ankle joint were obtained in vivo by MRI scans on 10 male subjects whereas the 'true' hip joint centre was obtained in 10 male and 10 female cadavers by CT scans. For the hip joint the errors ranged from 26.7 (8.9) to 29.6 (7.5) mm, for the knee joint 5.8 (3.1) to 22.6 (3.3) mm and for the ankle joint 14.4 (2.2) to 27.0 (4.6) mm. This differed significantly from the improved equations by which the error for the hip joint ranged from 8.2 (3.6) to 11.6 (5.6) mm, for the knee joint from 2.9 (2.1) to 4.7 (2.5) mm and for the ankle joint from 3.4 (1.3) to 4.1 (2.0) mm. The coefficients in the new hip joint equations differed significantly between sexes. This difference depends on anatomical differences of the male and female pelvis.
- 30 July 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (9) , 1168-1175
Markerless motion capture can provide reliable 3D gait kinematics in the sagittal and frontal plane
Estimating 3D joint rotations in the lower extremities accurately and reliably remains unresolved in markerless motion capture, despite extensive studies in the past decades. The main problems have been ascribed to the limited accuracy of the 3D reconstructions. Accordingly, the purpose of the present study was to develop a new approach based on highly detailed 3D reconstructions in combination with a translational and rotational unconstrained articulated model. The highly detailed 3D reconstructions were synthesized from an eight camera setup using a stereo vision approach. The subject specific articulated model was generated with three rotational and three translational degrees of freedom for each limb segment and without any constraints to the range of motion. This approach was tested on 3D gait analysis and compared to a marker based method. The experiment included ten healthy subjects in whom hip, knee and ankle joint were analysed. Flexion/extension angles as well as hip abduction/adduction closely resembled those obtained from the marker based system. However, the internal/external rotations, knee abduction/adduction and ankle inversion/eversion were less reliable.
- 30 July 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (9) , 1168-1175
Markerless motion capture can provide reliable 3D gait kinematics in the sagittal and frontal plane
Estimating 3D joint rotations in the lower extremities accurately and reliably remains unresolved in markerless motion capture, despite extensive studies in the past decades. The main problems have been ascribed to the limited accuracy of the 3D reconstructions. Accordingly, the purpose of the present study was to develop a new approach based on highly detailed 3D reconstructions in combination with a translational and rotational unconstrained articulated model. The highly detailed 3D reconstructions were synthesized from an eight camera setup using a stereo vision approach. The subject specific articulated model was generated with three rotational and three translational degrees of freedom for each limb segment and without any constraints to the range of motion. This approach was tested on 3D gait analysis and compared to a marker based method. The experiment included ten healthy subjects in whom hip, knee and ankle joint were analysed. Flexion/extension angles as well as hip abduction/adduction closely resembled those obtained from the marker based system. However, the internal/external rotations, knee abduction/adduction and ankle inversion/eversion were less reliable.