Izni Syahrizal Ibrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Izni Syahrizal Ibrahim has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Shing Mei Chiew
Universiti Teknologi Malaysia
7 shared publications Khairul Hazman Padil
Faculty of civil Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
4 shared publicationsNoor Nabilah Sarbini
Faculty of civil Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
4 shared publications- Han-Seung Lee
Department of Architectural Engineering, Hanyang University, Ansan, South Korea
3 shared publications - Jitendra Kumar Singh
Innovative Durable Building and Infrastructure Research Center, Center for Creative Convergence Education, Hanyang University (ERICA Campus), 1271 Sa-3-dong, Sangnok-gu, Ansan 15588, Republic of Korea
3 shared publications - Khairul Hazman Padil
Forensic Engineering Centre (FEC), Institute for Smart Infrastructure and Innovative Construction (ISiiC), Faculty of Civil Engineering Universiti Teknologi Malaysia Johor Bahru Johor Malaysia
3 shared publications
Latest Publications
- 1 October 2026
- Published by Wiley in Structural Concrete
Mechanical and structural performance of reinforcement strategies in 3D concrete printing: A review
3D concrete printing (3DCP) has emerged in recent decades as a promising construction technology that minimizes labor‐intensive and time‐consuming processes. Reinforcement integration is essential to ensure structural integrity and durability, particularly for large‐scale applications. While many reviews have focused on reinforcement classifications, there remains a lack of in‐depth evaluation of mechanical and structural performance, automation feasibility, and large‐scale validation. This review addresses these gaps by critically examining three categories of reinforcement: intralayer (fibers, cables, continuous yarns), interlayer (steel rebar, barbed wire, screws), and across‐layer (steel cages, meshes, post‐tensioning). Intralayer reinforcement offers excellent automation compatibility and design freedom, but contributes little to large‐scale load resistance due to discontinuity and low stiffness. Interlayer reinforcement improves bonding and ductility but introduces matrix disturbance and anchorage challenges. Across‐layer reinforcement provides the most reliable structural performance, essential for seismic and load‐bearing capacity, but limited automation maturity and design freedom. Hybrid systems emerge as promising strategies, combining material‐ and structural‐level reinforcement to enhance ductility, toughness, and load capacity, though their integration remains costly, complex, and less automation‐friendly. Current investigations are disproportionately skewed toward flexural behavior, while critical tests such as pull‐out, interlayer bond strength, compression, shear, and seismic loading are underexplored. Future work should prioritize large‐scale/field‐scale and long‐term structural validation, develop standardized fabrication and testing protocols, and advance reinforcement strategies that reconcile automation potential with structural reliability.
- 1 October 2026
- Published by Wiley in Structural Concrete
Mechanical and structural performance of reinforcement strategies in 3D concrete printing: A review
3D concrete printing (3DCP) has emerged in recent decades as a promising construction technology that minimizes labor‐intensive and time‐consuming processes. Reinforcement integration is essential to ensure structural integrity and durability, particularly for large‐scale applications. While many reviews have focused on reinforcement classifications, there remains a lack of in‐depth evaluation of mechanical and structural performance, automation feasibility, and large‐scale validation. This review addresses these gaps by critically examining three categories of reinforcement: intralayer (fibers, cables, continuous yarns), interlayer (steel rebar, barbed wire, screws), and across‐layer (steel cages, meshes, post‐tensioning). Intralayer reinforcement offers excellent automation compatibility and design freedom, but contributes little to large‐scale load resistance due to discontinuity and low stiffness. Interlayer reinforcement improves bonding and ductility but introduces matrix disturbance and anchorage challenges. Across‐layer reinforcement provides the most reliable structural performance, essential for seismic and load‐bearing capacity, but limited automation maturity and design freedom. Hybrid systems emerge as promising strategies, combining material‐ and structural‐level reinforcement to enhance ductility, toughness, and load capacity, though their integration remains costly, complex, and less automation‐friendly. Current investigations are disproportionately skewed toward flexural behavior, while critical tests such as pull‐out, interlayer bond strength, compression, shear, and seismic loading are underexplored. Future work should prioritize large‐scale/field‐scale and long‐term structural validation, develop standardized fabrication and testing protocols, and advance reinforcement strategies that reconcile automation potential with structural reliability.
- 17 February 2026
- Published by Springer Nature
- p. 247-254
Tunnel Defect Assessment Using 3D-Point Cloud
- Open Access
- 11 September 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (7) , 1-27
Vehicle Induced Vibration Analysis on Floor Building: A State of the A rt Review
- 11 September 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (7) , 1-27
Open AccessVehicle Induced Vibration Analysis on Floor Building: A State of the A rt Review
- 25 July 2025
- Published by Elsevier in Journal of Cleaner Production
- Vol. 521
Preliminary study on influence of UV radiation on the light transmittance of light-transmitting concrete
- 25 July 2025
- Published by Elsevier in Journal of Cleaner Production
- Vol. 521
Preliminary study on influence of UV radiation on the light transmittance of light-transmitting concrete
- 3 July 2025
- Published by Springer Nature
- p. 183-194
Manufactured Sand as Replacement to Fine Aggregates in Concrete
- 3 July 2025
- Published by Springer Nature
- p. 183-194
Manufactured Sand as Replacement to Fine Aggregates in Concrete
- Open Access
- 27 June 2025
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 10 (7) , 1-15
Visual inspection and defects of unlined and lined water transfer tunnel
- 27 June 2025
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 10 (7) , 1-15
Open AccessVisual inspection and defects of unlined and lined water transfer tunnel
- 10 June 2025
- Published by Wiley in Structural Concrete
- Vol. 27 (1) , 1045-1067
Evaluating manufactured sand as a sustainable alternative in high‐strength concrete: An experimental and machine learning study
The depletion of natural sand and the limited investigation into manufactured sand (M‐sand) as fine aggregate replacement in high‐strength concrete (HSC) present key challenges for sustainable construction. This study investigates the effects of varying levels of M‐sand replacement (10%–100%) on the fresh and mechanical properties of HSC. Experimental testing was conducted to evaluate its workability, compressive strength, and microstructural characteristics. A total of 278 datasets, including both literature‐derived and experimental data, were used to develop predictive models employing artificial neural networks (ANN) and regression trees (RT). The ANN and RT models were trained and validated through blind testing, with the ANN demonstrating superior predictive accuracy within a ±20% error range. Experimental results showed that a complete replacement of natural sand with M‐sand led to a 25%–35% increase in compressive strength, attributed to improved particle packing and matrix densification. Microstructural analysis confirmed the reduction in interfacial voids at higher M‐sand replacement levels. The findings suggest that M‐sand is a viable and sustainable alternative to natural sand in HSC applications. Furthermore, the ANN model offers a reliable and efficient tool for predicting compressive strength, potentially reducing the need for extensive physical testing. These outcomes contribute to sustainable construction practices and provide practical insight into the application of machine learning for concrete mix optimization.
- 10 June 2025
- Published by Wiley in Structural Concrete
- Vol. 27 (1) , 1045-1067
Evaluating manufactured sand as a sustainable alternative in high‐strength concrete: An experimental and machine learning study
The depletion of natural sand and the limited investigation into manufactured sand (M‐sand) as fine aggregate replacement in high‐strength concrete (HSC) present key challenges for sustainable construction. This study investigates the effects of varying levels of M‐sand replacement (10%–100%) on the fresh and mechanical properties of HSC. Experimental testing was conducted to evaluate its workability, compressive strength, and microstructural characteristics. A total of 278 datasets, including both literature‐derived and experimental data, were used to develop predictive models employing artificial neural networks (ANN) and regression trees (RT). The ANN and RT models were trained and validated through blind testing, with the ANN demonstrating superior predictive accuracy within a ±20% error range. Experimental results showed that a complete replacement of natural sand with M‐sand led to a 25%–35% increase in compressive strength, attributed to improved particle packing and matrix densification. Microstructural analysis confirmed the reduction in interfacial voids at higher M‐sand replacement levels. The findings suggest that M‐sand is a viable and sustainable alternative to natural sand in HSC applications. Furthermore, the ANN model offers a reliable and efficient tool for predicting compressive strength, potentially reducing the need for extensive physical testing. These outcomes contribute to sustainable construction practices and provide practical insight into the application of machine learning for concrete mix optimization.
- Open Access
- 27 May 2025
- Published by Springer Nature in Fire Technology
- p. 1-37
Three-Phase Evaluation of Fire-Exposed Reinforced Concrete Beams: Methodology and Outcomes
- 27 May 2025
- Published by Springer Nature in Fire Technology
- p. 1-37
Open AccessThree-Phase Evaluation of Fire-Exposed Reinforced Concrete Beams: Methodology and Outcomes
- Open Access
Effects of Hybrid Corrosion Inhibitor on Mechanical Characteristics, Corrosion Behavior, and Predictive Estimation of Lifespan of Reinforced Concrete Structures
A fixed ratio amount, i.e., L-arginine (LA) and trisodium phosphate dodecahydrate (TSP) at 2:0.25, is considered as a hybrid inhibitor. This research aims to extensively investigate the impact of utilizing the hybrid corrosion inhibitor on the corrosion resistance properties in accelerated condition, mechanical characteristics, and predictive estimation of the lifespan of reinforced concrete (RC) structures. Various experiments, such as setting time, slump, air content, porosity, compressive strength, and chloride diffusion coefficient, were conducted to elucidate the influence of the hybrid corrosion inhibitor on the mechanical properties of the concrete matrix. Meanwhile, linear polarization resistance (LPR) and electrochemical impedance spectroscopy (EIS) in 10 wt. % NaCl under wet–dry cycles are utilized to assess the corrosion resistance property, corrosion initiation time, and kinetics of the passive film formation on the steel rebar. Alternatively, both deterministic and probabilistic-based predictions of service life by Life 365 software are utilized to demonstrate the efficacy of the hybrid corrosion inhibitor in protecting the steel rebar in RC structures. All the results confirm that the HI-4 mix (LA:TSP = 3.56:0.44) exhibits excellence in preventing the corrosion and extending the service life of RC structures, due to the adsorption of inhibitor molecules and formation of P-Zwitterions-(Cl)-Fe, Zwitterions-(Cl)-Fe, and FePO4 complexes onto the steel rebar surface. However, HI-3 shows the optimal mechanical and electrochemical properties for RC structures.
Open AccessEffects of Hybrid Corrosion Inhibitor on Mechanical Characteristics, Corrosion Behavior, and Predictive Estimation of Lifespan of Reinforced Concrete Structures
A fixed ratio amount, i.e., L-arginine (LA) and trisodium phosphate dodecahydrate (TSP) at 2:0.25, is considered as a hybrid inhibitor. This research aims to extensively investigate the impact of utilizing the hybrid corrosion inhibitor on the corrosion resistance properties in accelerated condition, mechanical characteristics, and predictive estimation of the lifespan of reinforced concrete (RC) structures. Various experiments, such as setting time, slump, air content, porosity, compressive strength, and chloride diffusion coefficient, were conducted to elucidate the influence of the hybrid corrosion inhibitor on the mechanical properties of the concrete matrix. Meanwhile, linear polarization resistance (LPR) and electrochemical impedance spectroscopy (EIS) in 10 wt. % NaCl under wet–dry cycles are utilized to assess the corrosion resistance property, corrosion initiation time, and kinetics of the passive film formation on the steel rebar. Alternatively, both deterministic and probabilistic-based predictions of service life by Life 365 software are utilized to demonstrate the efficacy of the hybrid corrosion inhibitor in protecting the steel rebar in RC structures. All the results confirm that the HI-4 mix (LA:TSP = 3.56:0.44) exhibits excellence in preventing the corrosion and extending the service life of RC structures, due to the adsorption of inhibitor molecules and formation of P-Zwitterions-(Cl)-Fe, Zwitterions-(Cl)-Fe, and FePO4 complexes onto the steel rebar surface. However, HI-3 shows the optimal mechanical and electrochemical properties for RC structures.