Murat Aksoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Murat Aksoy has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Roland Bammer
Department of Radiology, Stanford University, Palo Alto, CA, USA
15 shared publicationsJulian Maclaren
Department of Radiology, Stanford University, Palo Alto, CA, USA
6 shared publications- Roland Bammer
Lucas Center, Department of Radiology, Stanford University, Stanford, California, USA
5 shared publications - Christoph Forman
MR Product Innovation and Definition, Magnetic Resonance, Siemens Healthcare GmbH, 91052 Erlangen, Germany
4 shared publications Joachim Hornegger
Pattern Recognition Lab, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
4 shared publicationsStefan Skare
Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden
4 shared publications
Latest Publications
- 31 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (4) , 498-503
Rigid Motion Correction for Brain PET/MR Imaging Using Optical Tracking
A significant challenge during high-resolution PET brain imaging on PET/MR scanners is patient head motion. This challenge is particularly significant for clinical patient populations who struggle to remain motionless in the scanner for long periods of time. Head motion also affects the MR scan data. An optical motion tracking technique, which has already been demonstrated to perform MR motion correction during acquisition, is used with a list-mode PET reconstruction algorithm to correct the motion for each recorded event and produce a corrected reconstruction. The technique is demonstrated on real Alzheimer's disease patient data for the GE SIGNA PET/MR scanner.
- 31 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (4) , 498-503
Rigid Motion Correction for Brain PET/MR Imaging Using Optical Tracking
A significant challenge during high-resolution PET brain imaging on PET/MR scanners is patient head motion. This challenge is particularly significant for clinical patient populations who struggle to remain motionless in the scanner for long periods of time. Head motion also affects the MR scan data. An optical motion tracking technique, which has already been demonstrated to perform MR motion correction during acquisition, is used with a list-mode PET reconstruction algorithm to correct the motion for each recorded event and produce a corrected reconstruction. The technique is demonstrated on real Alzheimer's disease patient data for the GE SIGNA PET/MR scanner.
- 19 July 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (4) , 1911-1921
Prospective motion correction using coil‐mounted cameras: Cross‐calibration considerations
Purpose: Optical prospective motion correction substantially reduces sensitivity to motion in neuroimaging of human subjects. However, a major barrier to clinical deployment has been the time‐consuming cross‐calibration between the camera and MRI scanner reference frames. This work addresses this challenge.Methods: A single camera was mounted onto the head coil for tracking head motion. Two new methods were developed: (1) a rapid calibration method for camera‐to‐scanner cross‐calibration using a custom‐made tool incorporating wireless active markers, and (2) a calibration adjustment method to compensate for table motion between scans. Both methods were tested at 1.5T and 3T in vivo. Simulations were performed to determine the required mechanical tolerance for repositioning of the camera.Results: The rapid calibration method is completed in a short (<30 s) scan, which is carried out only once per installation. The calibration adjustment method requires no extra scan time and runs automatically whenever the system is used. The mechanical tolerance analysis indicates that most motion (90% reduction in voxel displacement) could be corrected even with far larger camera repositioning errors than are observed in practice.Conclusion: The methods presented here allow calibration of sufficient quality to be carried out and maintained with no additional technologist workload. Magn Reson Med 79:1911–1921, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 19 July 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (4) , 1911-1921
Prospective motion correction using coil‐mounted cameras: Cross‐calibration considerations
Purpose: Optical prospective motion correction substantially reduces sensitivity to motion in neuroimaging of human subjects. However, a major barrier to clinical deployment has been the time‐consuming cross‐calibration between the camera and MRI scanner reference frames. This work addresses this challenge.Methods: A single camera was mounted onto the head coil for tracking head motion. Two new methods were developed: (1) a rapid calibration method for camera‐to‐scanner cross‐calibration using a custom‐made tool incorporating wireless active markers, and (2) a calibration adjustment method to compensate for table motion between scans. Both methods were tested at 1.5T and 3T in vivo. Simulations were performed to determine the required mechanical tolerance for repositioning of the camera.Results: The rapid calibration method is completed in a short (<30 s) scan, which is carried out only once per installation. The calibration adjustment method requires no extra scan time and runs automatically whenever the system is used. The mechanical tolerance analysis indicates that most motion (90% reduction in voxel displacement) could be corrected even with far larger camera repositioning errors than are observed in practice.Conclusion: The methods presented here allow calibration of sufficient quality to be carried out and maintained with no additional technologist workload. Magn Reson Med 79:1911–1921, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 1 June 2017
- Published by Elsevier in NeuroImage
- Vol. 153, 97-108
Extended hybrid-space SENSE for EPI: Off-resonance and eddy current corrected joint interleaved blip-up/down reconstruction
- 1 June 2017
- Published by Elsevier in NeuroImage
- Vol. 153, 97-108
Extended hybrid-space SENSE for EPI: Off-resonance and eddy current corrected joint interleaved blip-up/down reconstruction
- 1 June 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 39, 44-52
Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system
- 1 June 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 39, 44-52
Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Feasibility of Marker-Free Motion Tracking for Motion-Corrected MRI and PET-MRI
Prospective motion correction is a very promising compensation approach for magnetic resonance imaging (MRI) studies impacted by motion. It has the advantage over retrospective methods of being applicable to any pulse sequence. In prospective motion correction of brain studies, the magnetic field gradients and radio frequency waveforms are adjusted in real time in response to motion of the head, thereby maintaining a fixed frame of reference for the brain inside the scanner. A key requirement of this approach is accurate and rapidly sampled head pose information. Optical motion tracking is typically used to obtain these pose estimates, however current methods are limited by the need to attach physical markers to the skin. This readily leads to decoupling of the head and marker motion, reducing the effectiveness of correction. In this work we investigate the feasibility and initial performance of an optical motion tracking method which does not require any attached markers. The method relies on detecting natural features or amplified features (from skins stamps on the forehead) using multiple cameras, and estimates pose using a 3D-2D registration between a growing database of known 3D locations on the forehead and these features. We have performed out-of-bore and in-bore experiments to test the accuracy performance of this marker-free method for very small feature patches consistent with the limited visibility afforded by head coils used during imaging. The results showed excellent agreement between the marker-free method and our current ground truth method based on wireless MR-sensitive markers.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Feasibility of Marker-Free Motion Tracking for Motion-Corrected MRI and PET-MRI
Prospective motion correction is a very promising compensation approach for magnetic resonance imaging (MRI) studies impacted by motion. It has the advantage over retrospective methods of being applicable to any pulse sequence. In prospective motion correction of brain studies, the magnetic field gradients and radio frequency waveforms are adjusted in real time in response to motion of the head, thereby maintaining a fixed frame of reference for the brain inside the scanner. A key requirement of this approach is accurate and rapidly sampled head pose information. Optical motion tracking is typically used to obtain these pose estimates, however current methods are limited by the need to attach physical markers to the skin. This readily leads to decoupling of the head and marker motion, reducing the effectiveness of correction. In this work we investigate the feasibility and initial performance of an optical motion tracking method which does not require any attached markers. The method relies on detecting natural features or amplified features (from skins stamps on the forehead) using multiple cameras, and estimates pose using a 3D-2D registration between a growing database of known 3D locations on the forehead and these features. We have performed out-of-bore and in-bore experiments to test the accuracy performance of this marker-free method for very small feature patches consistent with the limited visibility afforded by head coils used during imaging. The results showed excellent agreement between the marker-free method and our current ground truth method based on wireless MR-sensitive markers.
- Open Access
- 18 May 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (2) , 571-577
Contact‐free physiological monitoring using a markerless optical system
Purpose: Physiological noise remains a major problem in MRI, particularly at higher imaging resolutions and field strengths. The aim of this work was to investigate the feasibility of using an MR‐compatible in‐bore camera system to perform contactless monitoring of cardiac and respiratory information during MRI of human subjects.Methods: An MR‐compatible camera was mounted on an eight‐channel head coil. Video data of the skin was processed offline to derive cardiac and respiratory signals from the pixel signal intensity and from head motion in the patient head–feet direction. These signals were then compared with data acquired simultaneously from the pulse oximeter and the respiratory belt.Results: The cardiac signal computed using the average image pixel intensity closely resembled the signal obtained using the pulse oximeter. Trigger intervals obtained from both systems matched to within 50 ms (one standard deviation). The respiratory signal computed from small in‐plane movements closely matched the signal obtained from the respiratory belt. Simultaneous MR imaging did not appear to have an effect on the physiological signals acquired by means of the contact‐free monitoring system.Conclusion: Contact‐free monitoring of human subjects to obtain cardiac and respiratory information is feasible using a small camera and light emitting diode mounted on the head coil of an MRI scanner. Magn Reson Med 74:571–577, 2015.
- 18 May 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (2) , 571-577
Open AccessContact‐free physiological monitoring using a markerless optical system
Purpose: Physiological noise remains a major problem in MRI, particularly at higher imaging resolutions and field strengths. The aim of this work was to investigate the feasibility of using an MR‐compatible in‐bore camera system to perform contactless monitoring of cardiac and respiratory information during MRI of human subjects.Methods: An MR‐compatible camera was mounted on an eight‐channel head coil. Video data of the skin was processed offline to derive cardiac and respiratory signals from the pixel signal intensity and from head motion in the patient head–feet direction. These signals were then compared with data acquired simultaneously from the pulse oximeter and the respiratory belt.Results: The cardiac signal computed using the average image pixel intensity closely resembled the signal obtained using the pulse oximeter. Trigger intervals obtained from both systems matched to within 50 ms (one standard deviation). The respiratory signal computed from small in‐plane movements closely matched the signal obtained from the respiratory belt. Simultaneous MR imaging did not appear to have an effect on the physiological signals acquired by means of the contact‐free monitoring system.Conclusion: Contact‐free monitoring of human subjects to obtain cardiac and respiratory information is feasible using a small camera and light emitting diode mounted on the head coil of an MRI scanner. Magn Reson Med 74:571–577, 2015.
- 8 April 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (2) , 565-576
Real‐time correction of rigid body motion‐induced phase errors for diffusion‐weighted steady‐state free precession imaging
Purpose: Diffusion contrast in diffusion‐weighted steady‐state free precession magnetic resonance imaging (MRI) is generated through the constructive addition of signal from many coherence pathways. Motion‐induced phase causes destructive interference which results in loss of signal magnitude and diffusion contrast. In this work, a three‐dimensional (3D) navigator‐based real‐time correction of the rigid body motion‐induced phase errors is developed for diffusion‐weighted steady‐state free precession MRI.Methods: The efficacy of the real‐time prospective correction method in preserving phase coherence of the steady state is tested in 3D phantom experiments and 3D scans of healthy human subjects.Results: In nearly all experiments, the signal magnitude in images obtained with proposed prospective correction was higher than the signal magnitude in images obtained with no correction. In the human subjects, the mean magnitude signal in the data was up to 30% higher with prospective motion correction than without. Prospective correction never resulted in a decrease in mean signal magnitude in either the data or in the images.Conclusions: The proposed prospective motion correction method is shown to preserve the phase coherence of the steady state in diffusion‐weighted steady‐state free precession MRI, thus mitigating signal magnitude losses that would confound the desired diffusion contrast. Magn Reson Med 73:565–576, 2015. © 2014 Wiley Periodicals, Inc.
- 8 April 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (2) , 565-576
Real‐time correction of rigid body motion‐induced phase errors for diffusion‐weighted steady‐state free precession imaging
Purpose: Diffusion contrast in diffusion‐weighted steady‐state free precession magnetic resonance imaging (MRI) is generated through the constructive addition of signal from many coherence pathways. Motion‐induced phase causes destructive interference which results in loss of signal magnitude and diffusion contrast. In this work, a three‐dimensional (3D) navigator‐based real‐time correction of the rigid body motion‐induced phase errors is developed for diffusion‐weighted steady‐state free precession MRI.Methods: The efficacy of the real‐time prospective correction method in preserving phase coherence of the steady state is tested in 3D phantom experiments and 3D scans of healthy human subjects.Results: In nearly all experiments, the signal magnitude in images obtained with proposed prospective correction was higher than the signal magnitude in images obtained with no correction. In the human subjects, the mean magnitude signal in the data was up to 30% higher with prospective motion correction than without. Prospective correction never resulted in a decrease in mean signal magnitude in either the data or in the images.Conclusions: The proposed prospective motion correction method is shown to preserve the phase coherence of the steady state in diffusion‐weighted steady‐state free precession MRI, thus mitigating signal magnitude losses that would confound the desired diffusion contrast. Magn Reson Med 73:565–576, 2015. © 2014 Wiley Periodicals, Inc.
- 5 March 2014
- Published by Wiley in Journal of Neuroimaging
- Vol. 25 (2) , 296-302
Effect of Number of Acquisitions in Diffusion Tensor Imaging of the Pediatric Brain: Optimizing Scan Time and Diagnostic Experience
Diffusion tensor imaging (DTI) is useful for multiple clinical applications, but its routine implementation for children may be difficult due to long scan times. This study evaluates the impact of decreasing the number of DTI acquisitions (NEX) on interpretability of pediatric brain DTI. 15 children with MRI-visible neuropathologies were imaged at 3T using our motion-corrected, parallel imaging- accelerated DT-EPI technique with 3 NEX (scan time 8.25 min). Using these acquisitions, NEX = 1 (scan time 2.75 min) and NEX = 2 (scan time 5.5 min) images were simulated. Two neuroradiologists scored diffusion-weighted images (DWI), apparent diffusion coefficient (ADC), fractional anisotropy (FA), and first eigenvector color-encoded (EV) images from each NEX for perceived SNR, lesion conspicuity and clinical confidence. ROI FA/ADC and image SNR values were also compared across NEX. NEX = 2 perceived SNR, lesion conspicuity, and clinical confidence were not inferior to NEX = 3 images. NEX = 1 images showed comparable lesion conspicuity and clinical confidence as NEX = 3, but inferior perceived SNR. FA and ADC ROI measurements demonstrated no significant difference across NEX. The greatest SNR increase was seen between NEX = 1 and NEX = 2. Reducing NEX to shorten imaging time may impact clinical utility in a manner that does not directly correspond with SNR changes.
- 5 March 2014
- Published by Wiley in Journal of Neuroimaging
- Vol. 25 (2) , 296-302
Effect of Number of Acquisitions in Diffusion Tensor Imaging of the Pediatric Brain: Optimizing Scan Time and Diagnostic Experience
Diffusion tensor imaging (DTI) is useful for multiple clinical applications, but its routine implementation for children may be difficult due to long scan times. This study evaluates the impact of decreasing the number of DTI acquisitions (NEX) on interpretability of pediatric brain DTI. 15 children with MRI-visible neuropathologies were imaged at 3T using our motion-corrected, parallel imaging- accelerated DT-EPI technique with 3 NEX (scan time 8.25 min). Using these acquisitions, NEX = 1 (scan time 2.75 min) and NEX = 2 (scan time 5.5 min) images were simulated. Two neuroradiologists scored diffusion-weighted images (DWI), apparent diffusion coefficient (ADC), fractional anisotropy (FA), and first eigenvector color-encoded (EV) images from each NEX for perceived SNR, lesion conspicuity and clinical confidence. ROI FA/ADC and image SNR values were also compared across NEX. NEX = 2 perceived SNR, lesion conspicuity, and clinical confidence were not inferior to NEX = 3 images. NEX = 1 images showed comparable lesion conspicuity and clinical confidence as NEX = 3, but inferior perceived SNR. FA and ADC ROI measurements demonstrated no significant difference across NEX. The greatest SNR increase was seen between NEX = 1 and NEX = 2. Reducing NEX to shorten imaging time may impact clinical utility in a manner that does not directly correspond with SNR changes.
- Open Access
- 27 June 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (3) , 639-647
Prospective motion correction using inductively coupled wireless RF coils
Purpose A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio‐frequency coils, or “wireless markers,” for position tracking. Methods Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil. Real‐time tracking of rigid head motion is performed using a pair of glasses integrated with three wireless markers. A tracking pulse‐sequence, combined with knowledge of the markers' unique geometrical arrangement, is used to measure their positions. Tracking data from the glasses is then used to prospectively update the orientation and position of the image‐volume so that it follows the motion of the head. Results Wireless‐marker position measurements were comparable to measurements using traditional wired radio‐frequency tracking coils, with the standard deviation of the difference < 0.01 mm over the range of positions measured inside the head coil. Wireless‐marker safety was verified with B1 maps and temperature measurements. Prospective motion correction was demonstrated in a 2D spin‐echo scan while the subject performed a series of deliberate head rotations. Conclusion Prospective motion correction using wireless markers enables high quality images to be acquired even during bulk motions. Wireless markers are small, avoid radio‐frequency safety risks from electrical cables, are not hampered by mechanical connections to the scanner, and require minimal setup times. These advantages may help to facilitate adoption in the clinic. Magn Reson Med 70:639–647, 2013.
- 27 June 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (3) , 639-647
Open AccessProspective motion correction using inductively coupled wireless RF coils
Purpose A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio‐frequency coils, or “wireless markers,” for position tracking. Methods Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil. Real‐time tracking of rigid head motion is performed using a pair of glasses integrated with three wireless markers. A tracking pulse‐sequence, combined with knowledge of the markers' unique geometrical arrangement, is used to measure their positions. Tracking data from the glasses is then used to prospectively update the orientation and position of the image‐volume so that it follows the motion of the head. Results Wireless‐marker position measurements were comparable to measurements using traditional wired radio‐frequency tracking coils, with the standard deviation of the difference < 0.01 mm over the range of positions measured inside the head coil. Wireless‐marker safety was verified with B1 maps and temperature measurements. Prospective motion correction was demonstrated in a 2D spin‐echo scan while the subject performed a series of deliberate head rotations. Conclusion Prospective motion correction using wireless markers enables high quality images to be acquired even during bulk motions. Wireless markers are small, avoid radio‐frequency safety risks from electrical cables, are not hampered by mechanical connections to the scanner, and require minimal setup times. These advantages may help to facilitate adoption in the clinic. Magn Reson Med 70:639–647, 2013.
- 2 May 2013
- Published by Taylor & Francis
- p. 41-84
Quantifying Brain Morphology Using Diffusion Imaging