Pedro Hervé-Fernández
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pedro Hervé-Fernández has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Pascal Boeckx
Isotope Bioscience Laboratory (ISOFYS), Faculty of Bioscience Engineering, Ghent University, Ghent, Belgium
4 shared publications- Ricardo A. Ayala
Faculty of Health & Social Sciences Universidad de las Américas Santiago de Chile Chile
3 shared publications Andreas Hemp
Department of Plant Systematics, University of Bayreuth, 95440 Bayreuth, Germany
2 shared publicationsArnaud Legout
INRA UR1138 Biogéochimie des Ecosystèmes Forestiers, INRA Centre de Nancy, Champenoux, France
2 shared publications- Barbara Herbstritt
Hydrology, Faculty of Environment and Natural Resources, Albert-Ludwigs-Universität, 79098 Freiburg, Germany
2 shared publications Barbora Gallagher
Institute for Environmental Research, Australia Nuclear Science and Technology Organization, Sydney, Australia
2 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Springer Nature in Discover Water
- Vol. 6 (1) , 110
A review of autonomous and low cost sensor systems for surface water quality monitoring with implications for local decision making
- 17 September 2026
- Published by Springer Nature in Discover Water
- Vol. 6 (1) , 110
Open AccessA review of autonomous and low cost sensor systems for surface water quality monitoring with implications for local decision making
- 30 March 2026
- Published by Taylor & Francis in Environmental Sociology
- p. 1-20
Stream of blame: navigating discourses of blame in water extractivism
- 30 March 2026
- Published by Taylor & Francis in Environmental Sociology
- p. 1-20
Stream of blame: navigating discourses of blame in water extractivism
- 31 January 2026
- Published by Taylor & Francis in Accountability in Research
- Vol. 33 (6) , 2623487
Emerging ethical duties in AI-mediated research: A case of data sovereignty in applying cross-national regulation
Artificial intelligence (AI) is reshaping research practices, yet its ethical implications remain under‑examined, particularly in cross‑national contexts. To explore how AI integration into environmental science complicates informed consent, privacy and data sovereignty, and to identify the ethical duties that follow for researchers. Drawing on a Chilean case study that adopts the European Union's General Data Protection Regulation (GDPR) as a normative framework, we focus on everyday AI‑mediated tools embedded in research infrastructures (e.g., transcription, cloud services, meeting assistants) and the tensions they introduce. AI intensifies -rather than replaces- ethical accountability, especially where legal protections are weak or infrastructures unequal. Algorithmic opacity constrains researcher autonomy and undermines data sovereignty. A governance approach grounded in data sovereignty and researcher autonomy is required to safeguard consent, privacy, and accountability in AI‑mediated research. We propose a revised model of ethical governance to support researchers working across fragmented regulations and opaque AI systems.
- 31 January 2026
- Published by Taylor & Francis in Accountability in Research
- Vol. 33 (6) , 2623487
Emerging ethical duties in AI-mediated research: A case of data sovereignty in applying cross-national regulation
Artificial intelligence (AI) is reshaping research practices, yet its ethical implications remain under‑examined, particularly in cross‑national contexts. To explore how AI integration into environmental science complicates informed consent, privacy and data sovereignty, and to identify the ethical duties that follow for researchers. Drawing on a Chilean case study that adopts the European Union's General Data Protection Regulation (GDPR) as a normative framework, we focus on everyday AI‑mediated tools embedded in research infrastructures (e.g., transcription, cloud services, meeting assistants) and the tensions they introduce. AI intensifies -rather than replaces- ethical accountability, especially where legal protections are weak or infrastructures unequal. Algorithmic opacity constrains researcher autonomy and undermines data sovereignty. A governance approach grounded in data sovereignty and researcher autonomy is required to safeguard consent, privacy, and accountability in AI‑mediated research. We propose a revised model of ethical governance to support researchers working across fragmented regulations and opaque AI systems.
- 6 January 2026
- Published by Springer Nature in Wetlands Ecology and Management
- Vol. 34 (1) , 7
Contribution of groundwater to wetland sustainability in arid Chile: an integrated hydrological, physicochemical, and isotopic approach
- 6 January 2026
- Published by Springer Nature in Wetlands Ecology and Management
- Vol. 34 (1) , 7
Contribution of groundwater to wetland sustainability in arid Chile: an integrated hydrological, physicochemical, and isotopic approach
- Open Access
- 7 July 2023
- Published by Elsevier in Rangeland Ecology & Management
- Vol. 90, 92-100
Influence of Rangeland Land Cover on Infiltration Rates, Field-Saturated Hydraulic Conductivity, and Soil Water Repellency in Southern Patagonia
- 7 July 2023
- Published by Elsevier in Rangeland Ecology & Management
- Vol. 90, 92-100
Open AccessInfluence of Rangeland Land Cover on Infiltration Rates, Field-Saturated Hydraulic Conductivity, and Soil Water Repellency in Southern Patagonia
- Open Access
- 23 May 2022
- Published by Wiley
On the urgent need for standardization in isotope-based ecohydrological investigations
Ecohydrological investigations commonly use the stable isotopes of water (hydrogen and oxygen) as a conservative ecosystem tracer. This approach requires accessing and analyzing water constrained within plant and soil matrices. Generally, there are six steps that researchers must pass through to retrieve hydrogen and oxygen isotope values from these plant and soil matrices: (i) sampling, (ii) sample storage and transport, (iii) extraction, (iv) pre-analysis processing, (v) isotopic analysis, and (vi) post-processing and correction. At each of these steps cumulative errors can be introduced which sum to non-trivial magnitudes. These errors can impact subsequent interpretations about water cycling through the soil-plant-atmosphere continuum. But these steps in the research ‘process chain’ are just the tip of the iceberg when it comes to uncertainly in published findings. At each of these discreet steps, there are multiple possible options to select from resulting in, as we will show, tens of thousands of possible combinations used by researchers to go from plant and soil samples to isotopic data. In a newly emerging science, so many options can create interpretive confusion and major issues with data comparability. This points to the need for the development of shared standardized approaches. Here we critically examine the state of the process chain, reflecting on the issues associated with each step, and end with suggestions to move our community towards standardization. We hope that critically assessing this common approach will help us see the current problem in its entirety and facilitate community action toward agreed upon standardized approaches.
- 23 May 2022
- Published by Wiley
Open AccessOn the urgent need for standardization in isotope-based ecohydrological investigations
Ecohydrological investigations commonly use the stable isotopes of water (hydrogen and oxygen) as a conservative ecosystem tracer. This approach requires accessing and analyzing water constrained within plant and soil matrices. Generally, there are six steps that researchers must pass through to retrieve hydrogen and oxygen isotope values from these plant and soil matrices: (i) sampling, (ii) sample storage and transport, (iii) extraction, (iv) pre-analysis processing, (v) isotopic analysis, and (vi) post-processing and correction. At each of these steps cumulative errors can be introduced which sum to non-trivial magnitudes. These errors can impact subsequent interpretations about water cycling through the soil-plant-atmosphere continuum. But these steps in the research ‘process chain’ are just the tip of the iceberg when it comes to uncertainly in published findings. At each of these discreet steps, there are multiple possible options to select from resulting in, as we will show, tens of thousands of possible combinations used by researchers to go from plant and soil samples to isotopic data. In a newly emerging science, so many options can create interpretive confusion and major issues with data comparability. This points to the need for the development of shared standardized approaches. Here we critically examine the state of the process chain, reflecting on the issues associated with each step, and end with suggestions to move our community towards standardization. We hope that critically assessing this common approach will help us see the current problem in its entirety and facilitate community action toward agreed upon standardized approaches.
- 3 May 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (15) , e9118
Organic contamination detection for isotopic analysis of water by laser spectroscopy
Rationale: Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O‐excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Methods: Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid‐ and vapour‐mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O‐excess contamination detection approach was tested. This is a post‐processing detection tool for both liquid and vapour IRIS triple‐isotope analyses, utilizing calculated 17 O‐excess values to flag contaminated samples. Results: Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour‐IRIS analyses had larger errors than those from liquid‐IRIS analyses. The 17 O‐excess approach identified methanol driven error in liquid‐ and vapour‐mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O‐excess method. Our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O‐excess method was therefore useful for data quality control. Conclusions: Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O‐excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.
- 3 May 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (15) , e9118
Organic contamination detection for isotopic analysis of water by laser spectroscopy
Rationale: Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O‐excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Methods: Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid‐ and vapour‐mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O‐excess contamination detection approach was tested. This is a post‐processing detection tool for both liquid and vapour IRIS triple‐isotope analyses, utilizing calculated 17 O‐excess values to flag contaminated samples. Results: Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour‐IRIS analyses had larger errors than those from liquid‐IRIS analyses. The 17 O‐excess approach identified methanol driven error in liquid‐ and vapour‐mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O‐excess method. Our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O‐excess method was therefore useful for data quality control. Conclusions: Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O‐excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.
- 5 April 2019
- Published by Wiley in Plant, Cell & Environment
- Vol. 42 (8) , 2437-2447
Hydraulic redistribution of foliar absorbed water causes turgor‐driven growth in mangrove seedlings
Although foliar water uptake (FWU) has been shown in mature Avicennia marina trees, the importance for its seedlings remains largely unknown. A series of experiments were therefore performed using artificial rainfall events in a greenhouse environment to assess the ecological implications of FWU in A. marina seedlings. One‐hour artificial rainfall events resulted in an increased leaf water potential, a reversed sap flow, and a rapid diameter increment signifying a turgor‐driven growth of up to 30.1 ± 5.4 μm. Furthermore, the application of an artificial rainfall event with deuterated water showed that the amount of water absorbed by the leaves and transported to the stem was directly and univocally correlated to the observed growth spurts. The observations in this process‐based study show that FWU is an important water acquisition mechanism under certain circumstances and might be of ecological importance for the establishment of A. marina seedlings. Distribution of mangrove trees might hence be more significantly disturbed by climate change‐driven changes in rainfall patterns than previously assumed.
- 5 April 2019
- Published by Wiley in Plant, Cell & Environment
- Vol. 42 (8) , 2437-2447
Hydraulic redistribution of foliar absorbed water causes turgor‐driven growth in mangrove seedlings
Although foliar water uptake (FWU) has been shown in mature Avicennia marina trees, the importance for its seedlings remains largely unknown. A series of experiments were therefore performed using artificial rainfall events in a greenhouse environment to assess the ecological implications of FWU in A. marina seedlings. One‐hour artificial rainfall events resulted in an increased leaf water potential, a reversed sap flow, and a rapid diameter increment signifying a turgor‐driven growth of up to 30.1 ± 5.4 μm. Furthermore, the application of an artificial rainfall event with deuterated water showed that the amount of water absorbed by the leaves and transported to the stem was directly and univocally correlated to the observed growth spurts. The observations in this process‐based study show that FWU is an important water acquisition mechanism under certain circumstances and might be of ecological importance for the establishment of A. marina seedlings. Distribution of mangrove trees might hence be more significantly disturbed by climate change‐driven changes in rainfall patterns than previously assumed.
- Open Access
- 6 July 2018
- Published by Copernicus GmbH in Hydrology and Earth System Sciences
- Vol. 22 (7) , 3619-3637
Inter-laboratory comparison of cryogenic water extraction systems for stable isotope analysis of soil water
For more than two decades, research groups in hydrology, ecology, soil science, and biogeochemistry have performed cryogenic water extractions (CWEs) for the analysis of δ2H and δ18O of soil water. Recent studies have shown that extraction conditions (time, temperature, and vacuum) along with physicochemical soil properties may affect extracted soil water isotope composition. Here we present results from the first worldwide round robin laboratory intercomparison. We test the null hypothesis that, with identical soils, standards, extraction protocols, and isotope analyses, cryogenic extractions across all laboratories are identical. Two standard soils with different physicochemical characteristics along with deionized (DI) reference water of known isotopic composition were shipped to 16 participating laboratories. Participants oven-dried and rewetted the soils to 8 and 20 % gravimetric water content (WC), using the deionized reference water. One batch of soil samples was extracted via predefined extraction conditions (time, temperature, and vacuum) identical to all laboratories; the second batch was extracted via conditions considered routine in the respective laboratory. All extracted water samples were analyzed for δ18O and δ2H by the lead laboratory (Global Institute for Water Security, GIWS, Saskatoon, Canada) using both a laser and an isotope ratio mass spectrometer (OA-ICOS and IRMS, respectively). We rejected the null hypothesis. Our results showed large differences in retrieved isotopic signatures among participating laboratories linked to soil type and soil water content with mean differences compared to the reference water ranging from +18.1 to −108.4 ‰ for δ2H and +11.8 to −14.9 ‰ for δ18O across all laboratories. In addition, differences were observed between OA-ICOS and IRMS isotope data. These were related to spectral interferences during OA-ICOS analysis that are especially problematic for the clayey loam soils used. While the types of cryogenic extraction lab construction varied from manifold systems to single chambers, no clear trends between system construction, applied extraction conditions, and extraction results were found. Rather, observed differences in the isotope data were influenced by interactions between multiple factors (soil type and properties, soil water content, system setup, extraction efficiency, extraction system leaks, and each lab's internal accuracy). Our results question the usefulness of cryogenic extraction as a standard for water extraction since results are not comparable across laboratories. This suggests that defining any sort of standard extraction procedure applicable across laboratories is challenging. Laboratories might have to establish calibration functions for their specific extraction system for each natural soil type, individually.
- 6 July 2018
- Published by Copernicus GmbH in Hydrology and Earth System Sciences
- Vol. 22 (7) , 3619-3637
Open AccessInter-laboratory comparison of cryogenic water extraction systems for stable isotope analysis of soil water
For more than two decades, research groups in hydrology, ecology, soil science, and biogeochemistry have performed cryogenic water extractions (CWEs) for the analysis of δ2H and δ18O of soil water. Recent studies have shown that extraction conditions (time, temperature, and vacuum) along with physicochemical soil properties may affect extracted soil water isotope composition. Here we present results from the first worldwide round robin laboratory intercomparison. We test the null hypothesis that, with identical soils, standards, extraction protocols, and isotope analyses, cryogenic extractions across all laboratories are identical. Two standard soils with different physicochemical characteristics along with deionized (DI) reference water of known isotopic composition were shipped to 16 participating laboratories. Participants oven-dried and rewetted the soils to 8 and 20 % gravimetric water content (WC), using the deionized reference water. One batch of soil samples was extracted via predefined extraction conditions (time, temperature, and vacuum) identical to all laboratories; the second batch was extracted via conditions considered routine in the respective laboratory. All extracted water samples were analyzed for δ18O and δ2H by the lead laboratory (Global Institute for Water Security, GIWS, Saskatoon, Canada) using both a laser and an isotope ratio mass spectrometer (OA-ICOS and IRMS, respectively). We rejected the null hypothesis. Our results showed large differences in retrieved isotopic signatures among participating laboratories linked to soil type and soil water content with mean differences compared to the reference water ranging from +18.1 to −108.4 ‰ for δ2H and +11.8 to −14.9 ‰ for δ18O across all laboratories. In addition, differences were observed between OA-ICOS and IRMS isotope data. These were related to spectral interferences during OA-ICOS analysis that are especially problematic for the clayey loam soils used. While the types of cryogenic extraction lab construction varied from manifold systems to single chambers, no clear trends between system construction, applied extraction conditions, and extraction results were found. Rather, observed differences in the isotope data were influenced by interactions between multiple factors (soil type and properties, soil water content, system setup, extraction efficiency, extraction system leaks, and each lab's internal accuracy). Our results question the usefulness of cryogenic extraction as a standard for water extraction since results are not comparable across laboratories. This suggests that defining any sort of standard extraction procedure applicable across laboratories is challenging. Laboratories might have to establish calibration functions for their specific extraction system for each natural soil type, individually.
- Open Access
- 15 March 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-36
Inter-laboratory comparison of cryogenic water extraction systems for stable isotope analysis of soil water
For more than two decades, research groups in hydrology, ecology, soil science and biogeochemistry have performed cryogenic water extractions for the analysis of δ2H and δ18O of soil water. Recent studies have shown that extraction conditions (time, temperature, and vacuum) along with physicochemical soil properties may affect extracted soil water isotope results. Here we present results from the first worldwide round robin laboratory intercomparison. We test the null hypothesis that with identical soils, standards, extraction protocols and isotope analyses, cryogenic extractions across all laboratories are identical. Two ‘standard soils’ with different physicochemical characteristics along with deionized reference water of known isotopic composition, were shipped to 16 participating laboratories. Participants oven-dried and rewetted the soils to 8 % and 20 % gravimetric water content, using the deionized reference water. One batch of soil samples was extracted via pre-defined extraction conditions (time, temperature, and vacuum) identical to all laboratories; the second batch was extracted via conditions considered routine in the respective laboratory. All extracted water samples were analyzed for δ18O and δ2H by the lead laboratory (Global Institute for Water Security, GIWS, Saskatoon, CA) using both a laser and an isotope ratio mass spectrometer (OA-ICOS and IRMS, respectively). We rejected the null hypothesis. Our results showed large differences in retrieved isotopic signatures among participating laboratories linked to soil type and soil water content with mean differences to the reference water ranging from +18.1 ‰ to −108.4 ‰ for δ2H and +11.8 ‰ to −14.9 ‰ for δ18O across all laboratories. In addition, differences were observed between OA-ICOS and IRMS isotope data. These were related to spectral interferences during OA-ICOS analysis that are especially problematic for the clayey loam soils used. While the types of cryogenic extraction lab construction varied from manifold systems to single chambers, no clear trends between system construction, applied extraction conditions, and extraction results were found. Rather, differences between isotope results were influenced by interactions between multiple factors (soil type and properties, soil water content, system setup, extraction efficiency, extraction system leaks, and each lab’s internal accuracy). Our results question the usefulness of cryogenic extraction as a standard for water extraction since results are not comparable across laboratories. This suggests that defining any sort of standard extraction procedure applicable across laboratories is challenging. Laboratories might have to establish calibration functions for their specific extraction system for each natural soil type, individually.
- 15 March 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-36
Open AccessInter-laboratory comparison of cryogenic water extraction systems for stable isotope analysis of soil water
For more than two decades, research groups in hydrology, ecology, soil science and biogeochemistry have performed cryogenic water extractions for the analysis of δ2H and δ18O of soil water. Recent studies have shown that extraction conditions (time, temperature, and vacuum) along with physicochemical soil properties may affect extracted soil water isotope results. Here we present results from the first worldwide round robin laboratory intercomparison. We test the null hypothesis that with identical soils, standards, extraction protocols and isotope analyses, cryogenic extractions across all laboratories are identical. Two ‘standard soils’ with different physicochemical characteristics along with deionized reference water of known isotopic composition, were shipped to 16 participating laboratories. Participants oven-dried and rewetted the soils to 8 % and 20 % gravimetric water content, using the deionized reference water. One batch of soil samples was extracted via pre-defined extraction conditions (time, temperature, and vacuum) identical to all laboratories; the second batch was extracted via conditions considered routine in the respective laboratory. All extracted water samples were analyzed for δ18O and δ2H by the lead laboratory (Global Institute for Water Security, GIWS, Saskatoon, CA) using both a laser and an isotope ratio mass spectrometer (OA-ICOS and IRMS, respectively). We rejected the null hypothesis. Our results showed large differences in retrieved isotopic signatures among participating laboratories linked to soil type and soil water content with mean differences to the reference water ranging from +18.1 ‰ to −108.4 ‰ for δ2H and +11.8 ‰ to −14.9 ‰ for δ18O across all laboratories. In addition, differences were observed between OA-ICOS and IRMS isotope data. These were related to spectral interferences during OA-ICOS analysis that are especially problematic for the clayey loam soils used. While the types of cryogenic extraction lab construction varied from manifold systems to single chambers, no clear trends between system construction, applied extraction conditions, and extraction results were found. Rather, differences between isotope results were influenced by interactions between multiple factors (soil type and properties, soil water content, system setup, extraction efficiency, extraction system leaks, and each lab’s internal accuracy). Our results question the usefulness of cryogenic extraction as a standard for water extraction since results are not comparable across laboratories. This suggests that defining any sort of standard extraction procedure applicable across laboratories is challenging. Laboratories might have to establish calibration functions for their specific extraction system for each natural soil type, individually.