Dapeng Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dapeng Zhao has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- Hemin Nie
Department of Biomedical Sciences, College of Biology, Hunan University, Changsha, China
5 shared publications - Ming Yan
Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
5 shared publications Florian Pyczak
4 shared publications- Keke Chang
State Key Laboratory of Advanced Marine Materials, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China
4 shared publications - Regine Willumeit-Römer
Institute of Metallic Biomaterials, Helmholtz Zentrum Hereon, Geesthacht, Germany
4 shared publications Thomas Ebel
4 shared publications
Latest Publications
- Open Access
Ti-Based Metallic Biomaterials for Antitumor Applications
Titanium (Ti)-based metallic biomaterials (MBs) are traditionally employed as mechanical supports and constraints in clinical practice, owing to their superb comprehensive mechanical properties, great corrosion resistance, and good biocompatibility. Recently, Ti-based MBs have emerged as promising candidates for antitumor applications. These developments focus on the functionalization of Ti-based MBs to inhibit tumor propagation and recurrence. This work systematically examines the antitumor approaches of Ti-based MBs and categorizes them into physical and chemical approaches. Physical strategies, such as the photothermal and photocatalytic techniques, are usually related to material-specific properties. Chemical approaches often employ controlled local drug delivery (LDD) systems. Ti-based LDD systems enable the targeted release of chemotherapeutics, metal ions, or immunomodulatory agents at tumor sites. This review highlights the efficacy of these surface-functionalized Ti-based MBs against diverse tumors. Additionally, the challenges and prospects of antitumor Ti-based MBs are also discussed.
Open AccessTi-Based Metallic Biomaterials for Antitumor Applications
Titanium (Ti)-based metallic biomaterials (MBs) are traditionally employed as mechanical supports and constraints in clinical practice, owing to their superb comprehensive mechanical properties, great corrosion resistance, and good biocompatibility. Recently, Ti-based MBs have emerged as promising candidates for antitumor applications. These developments focus on the functionalization of Ti-based MBs to inhibit tumor propagation and recurrence. This work systematically examines the antitumor approaches of Ti-based MBs and categorizes them into physical and chemical approaches. Physical strategies, such as the photothermal and photocatalytic techniques, are usually related to material-specific properties. Chemical approaches often employ controlled local drug delivery (LDD) systems. Ti-based LDD systems enable the targeted release of chemotherapeutics, metal ions, or immunomodulatory agents at tumor sites. This review highlights the efficacy of these surface-functionalized Ti-based MBs against diverse tumors. Additionally, the challenges and prospects of antitumor Ti-based MBs are also discussed.
- Open Access
- 21 October 2024
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 15 (10) , 312
A pH-Responsive Ti-Based Local Drug Delivery System for Osteosarcoma Therapy
Osteosarcoma is one of the major bone cancers, especially for youngsters. The current treatment usually requires systemic chemotherapy and the removal of bone tumors. Titanium (Ti)-based implants can be modified as local drug delivery (LDD) systems for controllable and localized chemotherapeutic drug release. In this work, a pH-responsive Ti-based LDD prototype was designed by introducing polydopamine (PDA) to release doxorubicin (DOX) around osteosarcoma cells with low pH. Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and a contact angle meter were applied for surface characterization. Both direct and indirect cell culture modes were performed for biocompatibility and biofunction assessments. The results indicate that the Ti-based LDD prototype exhibits significant pH-dependent DOX release. The cumulative release can reach up to approximately 40% at pH = 6.0 after 72 h, but only around 20% at pH = 7.4. The Ti-based LDD implant shows good biocompatibility with approximately 93% viability of MC3T3 cells after direct culture in vitro for 24 h. Both direct and indirect culture modes verify the good anti-osteosarcoma function of the LDD implant, which should be attributed to the pH-responsive release of DOX.
- 21 October 2024
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 15 (10) , 312
Open AccessA pH-Responsive Ti-Based Local Drug Delivery System for Osteosarcoma Therapy
Osteosarcoma is one of the major bone cancers, especially for youngsters. The current treatment usually requires systemic chemotherapy and the removal of bone tumors. Titanium (Ti)-based implants can be modified as local drug delivery (LDD) systems for controllable and localized chemotherapeutic drug release. In this work, a pH-responsive Ti-based LDD prototype was designed by introducing polydopamine (PDA) to release doxorubicin (DOX) around osteosarcoma cells with low pH. Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and a contact angle meter were applied for surface characterization. Both direct and indirect cell culture modes were performed for biocompatibility and biofunction assessments. The results indicate that the Ti-based LDD prototype exhibits significant pH-dependent DOX release. The cumulative release can reach up to approximately 40% at pH = 6.0 after 72 h, but only around 20% at pH = 7.4. The Ti-based LDD implant shows good biocompatibility with approximately 93% viability of MC3T3 cells after direct culture in vitro for 24 h. Both direct and indirect culture modes verify the good anti-osteosarcoma function of the LDD implant, which should be attributed to the pH-responsive release of DOX.
- Open Access
- 30 June 2023
- Published by Atlantis Press SARL
- p. 1104-1115
Exploration and Practice of Teaching Reform on Photoelectric Countermeasure Equipment
- 30 June 2023
- Published by Atlantis Press SARL
- p. 1104-1115
Open AccessExploration and Practice of Teaching Reform on Photoelectric Countermeasure Equipment
- 12 October 2022
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 8 (11) , 4976-4986
Early Antimicrobial Evaluation of Nanostructured Surfaces Based on Bacterial Biological Properties
Nanostructured physical antibacterial surfaces are of great interest due to the increasing antibiotic resistance. In this work, the titania nanotube (TNT) array, a potential physical antibacterial surface, was used for antimicrobial evaluation. The early antibacterial properties of TNTs were assessed based on three growth phases of Staphylococcus aureus (S. aureus), and the physical factors influencing the antibacterial properties were comprehensively discussed. The results show apparent early antibacterial effects of TNTs, including the anti-initial attachment during the lag phase, the inhibition of proliferation and bactericidal effect during the logarithmic phase, and the inhibition of biofilm formation during the stationary phase. These antimicrobial effects are closely related to the combined influence of various physical properties of TNTs, such as diameter, hydrophilicity, roughness, and charge. The present work suggests that the evaluation of the early antimicrobial behavior of biomaterials should pay more attention on the biological characteristics of bacteria.
- 12 October 2022
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 8 (11) , 4976-4986
Early Antimicrobial Evaluation of Nanostructured Surfaces Based on Bacterial Biological Properties
Nanostructured physical antibacterial surfaces are of great interest due to the increasing antibiotic resistance. In this work, the titania nanotube (TNT) array, a potential physical antibacterial surface, was used for antimicrobial evaluation. The early antibacterial properties of TNTs were assessed based on three growth phases of Staphylococcus aureus (S. aureus), and the physical factors influencing the antibacterial properties were comprehensively discussed. The results show apparent early antibacterial effects of TNTs, including the anti-initial attachment during the lag phase, the inhibition of proliferation and bactericidal effect during the logarithmic phase, and the inhibition of biofilm formation during the stationary phase. These antimicrobial effects are closely related to the combined influence of various physical properties of TNTs, such as diameter, hydrophilicity, roughness, and charge. The present work suggests that the evaluation of the early antimicrobial behavior of biomaterials should pay more attention on the biological characteristics of bacteria.
- 31 March 2022
- Published by Elsevier in Materials Letters
- Vol. 318
Achieving high strength and large ductility via Zr-rich stripes in Ti-15Zr alloy
- 31 March 2022
- Published by Elsevier in Materials Letters
- Vol. 318
Achieving high strength and large ductility via Zr-rich stripes in Ti-15Zr alloy
- 1 September 2021
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 205, 111848
The response of macrophages and their osteogenic potential modulated by micro/nano-structured Ti surfaces
- 1 September 2021
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 205, 111848
The response of macrophages and their osteogenic potential modulated by micro/nano-structured Ti surfaces
- Open Access
- 4 June 2021
- Published by KEAI Publishing in Bioactive Materials
- Vol. 7, 254-262
In vivo urinary compatibility of Mg-Sr-Ag alloy in swine model
A biodegradable metallic ureteral stent with suitable mechanical properties and antibacterial activity remains a challenge. Here we reveal the scientific significance of a biodegradable Mg-Sr-Ag alloy with a favorable combination of balanced mechanical properties, adjustable indwelling time in urinary tract and evident antibacterial activity via in vivo experiments in a swine model. Attributed to the rheo-solidification process, equiaxial microstructure and significantly refined grains (average grain size: 27.1 μm) were achieved. Mg17Sr2 and Mg4Ag were found as the primary precipitates in the matrix, due to which the alloy obtained ca. 111% increase in ultimate tensile strength in comparison to pure magnesium. Both the in vitro and in vivo results demonstrated the satisfactory biocompatibility of the alloy. Histological evaluation and bioindicators analysis suggested that there was no tissue damage, inflammation and lesions in the urinary system caused by the degradation process. The stent also improved the post-operative bladder functions viewed from the urodynamic results. Our findings highlight the potential of this alloy as antibacterial biodegradable urinary implant material.
- 4 June 2021
- Published by KEAI Publishing in Bioactive Materials
- Vol. 7, 254-262
Open AccessIn vivo urinary compatibility of Mg-Sr-Ag alloy in swine model
A biodegradable metallic ureteral stent with suitable mechanical properties and antibacterial activity remains a challenge. Here we reveal the scientific significance of a biodegradable Mg-Sr-Ag alloy with a favorable combination of balanced mechanical properties, adjustable indwelling time in urinary tract and evident antibacterial activity via in vivo experiments in a swine model. Attributed to the rheo-solidification process, equiaxial microstructure and significantly refined grains (average grain size: 27.1 μm) were achieved. Mg17Sr2 and Mg4Ag were found as the primary precipitates in the matrix, due to which the alloy obtained ca. 111% increase in ultimate tensile strength in comparison to pure magnesium. Both the in vitro and in vivo results demonstrated the satisfactory biocompatibility of the alloy. Histological evaluation and bioindicators analysis suggested that there was no tissue damage, inflammation and lesions in the urinary system caused by the degradation process. The stent also improved the post-operative bladder functions viewed from the urodynamic results. Our findings highlight the potential of this alloy as antibacterial biodegradable urinary implant material.
- 1 September 2020
- Published by Elsevier in Transactions of Nonferrous Metals Society of China
- Vol. 30 (9) , 2449-2458
Strong-yet-ductile Ti−Zr alloys through high concentration of oxygen strengthening
- 1 September 2020
- Published by Elsevier in Transactions of Nonferrous Metals Society of China
- Vol. 30 (9) , 2449-2458
Strong-yet-ductile Ti−Zr alloys through high concentration of oxygen strengthening
- 22 January 2019
- Published by Bentham Science Publishers Ltd. in Current Smart Materials
- Vol. 3 (2) , 74-89
The Design and Improvement of Aptamer-based Fluorescent Probes
Background: Fluorescent probes exhibit the characteristics of high sensitivity, diversified design, and strong quantitative analysis ability. Therefore, they have become one of the research hotspots in analytical chemistry and biological analysis. Aptamers are single stranded DNAs or RNAs that are obtained in vitro and can selectively bind to the targets, making them ideal candidates as identifying units in fluorescent probes. However, most of the current aptamer probes are not regulatable because their fluorescence signals can’t be changed after the fluorescent probes are bound to the target, resulting in a high signal background and limited contrast. Actually, the structure of aptamers is flexible and can be combined with a variety of nanomaterials to achieve high sensitivity fluorescence for quantitative analysis, and can be used for a variety of target determinations, such as metal ions, small molecules, proteins and cells. In addition, with the development of research on DNA nanotechnology, researchers have designed many aptamer-based fluorescent probes with special properties, which have good application prospects in complex sample analyses and even in vivo cell imaging. Conclusion: In this review, the development of research in the field of aptamer-based fluorescent probes is surveyed and four mechanisms of aptamer fluorescent probes, including dye intercalation, conversion of DNA conformation, signal amplification, and mediation of nanomaterials, are comprehensively discussed.
- 22 January 2019
- Published by Bentham Science Publishers Ltd. in Current Smart Materials
- Vol. 3 (2) , 74-89
The Design and Improvement of Aptamer-based Fluorescent Probes
Background: Fluorescent probes exhibit the characteristics of high sensitivity, diversified design, and strong quantitative analysis ability. Therefore, they have become one of the research hotspots in analytical chemistry and biological analysis. Aptamers are single stranded DNAs or RNAs that are obtained in vitro and can selectively bind to the targets, making them ideal candidates as identifying units in fluorescent probes. However, most of the current aptamer probes are not regulatable because their fluorescence signals can’t be changed after the fluorescent probes are bound to the target, resulting in a high signal background and limited contrast. Actually, the structure of aptamers is flexible and can be combined with a variety of nanomaterials to achieve high sensitivity fluorescence for quantitative analysis, and can be used for a variety of target determinations, such as metal ions, small molecules, proteins and cells. In addition, with the development of research on DNA nanotechnology, researchers have designed many aptamer-based fluorescent probes with special properties, which have good application prospects in complex sample analyses and even in vivo cell imaging. Conclusion: In this review, the development of research in the field of aptamer-based fluorescent probes is surveyed and four mechanisms of aptamer fluorescent probes, including dye intercalation, conversion of DNA conformation, signal amplification, and mediation of nanomaterials, are comprehensively discussed.
- 9 November 2018
- Published by Wiley in Rare Metals
- Vol. 37 (12) , 1055-1063
Macro‐micron‐nano‐featured surface topography of Ti‐6Al‐4V alloy for biomedical applications
One of the critical issues in the development of novel metallic biomaterials is the design and fabrication of metallic scaffolds and implants with hierarchical structures mimicking human bones. In this work, selective laser melting (SLM) and electrochemical anodization were applied to fabricate dense Ti‐6Al‐4V components with macro‐micron‐nanoscale hierarchical surfaces. Scanning electron microscopy (SEM), 3D laser scanning microscopy (3D LSM), contact angle video system, fluorescence microscopy and spectrophotometer were used to investigate the properties of the samples. The results reveal that the SLMed post‐anodization (SLM‐TNT) exhibits enhanced or at least comparable wettability, protein adsorption and biological response of mesenchymal stem cells (MSCs) in comparison with the three reference configurations, i.e., the polished Ti‐6Al‐4V (PO‐Ti64), the SLMed Ti‐6Al‐4V (SLM‐Ti64) and the polished Ti‐6Al‐4V post‐anodization (PO‐TNT). The improved cytocompatibility of the samples after SLM and anodization should be mainly attributed to the nanoscale tubular features, while the macro‐micron‐scale structures only lead to slight preference for cell attachment.
- 9 November 2018
- Published by Wiley in Rare Metals
- Vol. 37 (12) , 1055-1063
Macro‐micron‐nano‐featured surface topography of Ti‐6Al‐4V alloy for biomedical applications
One of the critical issues in the development of novel metallic biomaterials is the design and fabrication of metallic scaffolds and implants with hierarchical structures mimicking human bones. In this work, selective laser melting (SLM) and electrochemical anodization were applied to fabricate dense Ti‐6Al‐4V components with macro‐micron‐nanoscale hierarchical surfaces. Scanning electron microscopy (SEM), 3D laser scanning microscopy (3D LSM), contact angle video system, fluorescence microscopy and spectrophotometer were used to investigate the properties of the samples. The results reveal that the SLMed post‐anodization (SLM‐TNT) exhibits enhanced or at least comparable wettability, protein adsorption and biological response of mesenchymal stem cells (MSCs) in comparison with the three reference configurations, i.e., the polished Ti‐6Al‐4V (PO‐Ti64), the SLMed Ti‐6Al‐4V (SLM‐Ti64) and the polished Ti‐6Al‐4V post‐anodization (PO‐TNT). The improved cytocompatibility of the samples after SLM and anodization should be mainly attributed to the nanoscale tubular features, while the macro‐micron‐scale structures only lead to slight preference for cell attachment.