MLMark Lee

Mark Lee

*This is an algorithmically generated author record based on publicly available information.

Mark Lee has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Validation of a 3D‐Printed Percutaneous Injection Laryngoplasty Simulator: A Randomized Controlled Trial

    by Julianna C. Kostas, Andrew S. Lee, Amit Arunkumar, Catherine Han, Mark Lee, Alexander N. Goel, James Alrassi, Tyler Crosby, Christine M. Clark, Milan Amin, et al.

    Objective: Simulation may be a valuable tool in training laryngology office procedures on unsedated patients. However, no studies have examined whether existing awake procedure simulators improve trainee performance in laryngology. Our objective was to evaluate the transfer validity of a previously published 3D‐printed laryngeal simulator in improving percutaneous injection laryngoplasty (PIL) competency compared with conventional educational materials with a single‐blinded randomized controlled trial.Methods: Otolaryngology residents with fewer than 10 PIL procedures in their case logs were recruited. A pretraining survey was administered to participants to evaluate baseline procedure‐specific knowledge and confidence. The participants underwent block randomization by postgraduate year to receive conventional educational materials either with or without additional training with a 3D‐printed laryngeal simulator. Participants performed PIL on an anatomically distinct laryngeal model via trans‐thyrohyoid and trans‐cricothyroid approaches. Endoscopic and external performance recordings were de‐identified and evaluated by two blinded laryngologists using an objective structured assessment of technical skill scale and PIL‐specific checklist.Results: Twenty residents completed testing. Baseline characteristics demonstrate no significant differences in confidence level or PIL experience between groups. Senior residents receiving simulator training had significantly better respect for tissue during the trans‐thyrohyoid approach compared with control (p < 0.0005). There were no significant differences in performance for junior residents.Conclusions: In this first transfer validity study of a simulator for office awake procedure in laryngology, we found that a previously described low‐cost, high‐fidelity 3D‐printed PIL simulator improved performance of PIL amongst senior otolaryngology residents, suggesting this accessible model may be a valuable educational adjunct for advanced trainees to practice PIL.Level of Evidence: NA Laryngoscope, 134:318–323, 2024


  • Open Access

    Evaluation of the aerosol generating potential of endoscopic dacryocystorhinostomy

    by Darren A. Chen, Mark Lee, Gary J. Lelli, Ashutosh Kacker

    Purpose The COVID-19 pandemic gave rise to renewed concerns of the transmission risks posed by surgeries on sites of high viral colonization such as the nasopharynx. Endoscopic dacryocystorhinostomy (DCR) involves the creation of a new tear duct from the lacrimal sac to the nasal cavity. The purpose of this project is to determine if endoscopic DCR is an aerosol generating procedure (AGP). Methods An optical particle sizer (OPS) was used to intraoperatively quantify aerosol concentrations during four cases of endoscopic DCR. The OPS sampled the air once every 60 seconds throughout the operations. The time of important operative steps were documented and correlated with OPS readings. Particle concentrations during each major surgical step were compared to baseline readings by the Mann Whitney U Test. Results There were statistically significant increases in median particle concentrations during laryngeal mask airway intubations for both particles 0.3 to 5.0 μm and >5.0 μm (P < .001 and P = .023, respectively). Median particle concentrations during nasolacrimal duct probing, middle meatal debridement, drilling, balloon insertion, tube insertion, and Posisef insertion were not statistically different from baseline. Conclusions Endoscopic DCR in itself does not appear to be an AGP. It is, however, associated with other aerosol generating events such as laryngeal mask intubation, and thus requires appropriate personal protective equipment. Cautious interpretation of the results is encouraged given the limitations of OPS. Level of Evidence 4.

  • Patterns of Recurrence of Phonotraumatic Vocal Fold Lesions Suggest Distinct Mechanisms of Injury

    by Mark Lee, Ted Mau, Lucian Sulica

    Objectives/Hypothesis: To examine patterns of recurrence of benign phonotraumatic vocal fold lesions over time for insights into pathophysiology.Study Design: Case series with mathematical modeling.Methods: Medical records and stroboscopic exams of adults who underwent microlaryngoscopic resection of phonotraumatic vocal fold lesions over a 13‐year period were reviewed for time to recurrence after surgery. Uniform and log‐normal probability distributions were fitted to the time to recurrence curves for vocal fold polyps, midfold masses, and pseudocysts. Model fits were compared using the Akaike information criterion corrected, a standard measure of the goodness of fit. Stochastic simulations were used to verify that the mechanistic hypotheses were concordant with the selected probability distributions and empiric data.Results: Of 567 patients who underwent microlaryngoscopic resection, 65 had a recurrence (16 polyps, 14 midfold masses, and 35 pseudocysts). Midfold mass and pseudocyst recurrences were predominantly seen in younger women. Polyps were best fit by a uniform distribution rather than log‐normal, whereas midfold masses and pseudocysts were better fit by log‐normal rather than uniform. Stochastic simulations suggest that polyps recur sporadically according to a paroxysmal‐developmental model, whereas midfold mass and pseudocyst recurrences follow a force‐multiplication, damage‐accumulation process.Conclusions: Vocal fold polyps are acute lesions evenly distributed by age and gender that recur uniformly over time, suggesting they arise from sudden tissue reactions to phonotraumatic stress. Pseudocysts and midfold fibrous masses are chronic lesions predominantly found in young women that recur with log‐normal distribution over time, suggesting gradual damage accumulation in larynges predisposed to enhanced phonotrauma.Level of Evidence: 4 Laryngoscope, 131:2523–2529, 2021


  • An Open‐Source Three‐Dimensionally Printed Laryngeal Model for Injection Laryngoplasty Training

    by Mark Lee, Chelston Ang, Katerina Andreadis, James Shin, Anaïs Rameau

    Objectives/Hypothesis: A limited number of three‐dimensionally (3D)‐printed laryngeal simulators have been described in the literature, only one of which is specifically designed for percutaneous injection laryngoplasty (PIL) training and is currently of limited availability. This study describes the development and evaluation of a high‐fidelity, open‐source, low‐cost 3D‐printed simulator for PIL training, improving on existing models.Study Design: Simulator design and survey evaluation.Methods: Computed tomography scans of the upper airways were processed with 3D Slicer to generate a computer model of the endolarynx. Blender and Fusion 360 were used to refine the mucosal model and develop casts for silicone injection molding. The casted endolaryngeal structures were inserted into a modified version of a publicly available laryngeal cartilage model. The final models were evaluated by 10 expert laryngologists using a customized version of the Michigan Standard Simulation Experience Scale. Internal consistency and interrater reliability of the survey were evaluated using Cronbach's α and intraclass correlation, respectively.Results: Expert laryngologists highly rated the model for measures of fidelity, educational value, and overall quality (mean = 4.8, standard deviation = 0.5; 1 = strongly disagree, 5 = strongly agree). All reviewers rated the model as ready for use as is or with slight modifications. The filament needed for one cartilage model costs $0.96, whereas the silicone needed for one soft‐tissue model costs $1.89.Conclusions: Using 3D‐printing technology, we successfully created the first open‐source, low‐cost, and anatomically accurate laryngeal model for injection laryngoplasty training. Our simulator is made freely available for download on Wikifactory with step‐by‐step tutorials for 3D printing, silicone molding, assembly, and use.Level of Evidence: NA Laryngoscope, 131:E890–E895, 2021


  • Is Office Laryngoscopy an Aerosol‐Generating Procedure?

    by Anaïs Rameau, Mark Lee, Necati Enver, Lucian Sulica

    Objectives/Hypothesis: The aims of this work were 1) to investigate whether office laryngoscopy is an aerosol‐generating procedure with an optical particle sizer (OPS) during clinical simulation on healthy volunteers, and 2) to critically discuss methods for assessment of aerosolizing potentials in invasive interventions.Study Design: Prospective quantification of aerosol and droplet generation during clinical simulation of rigid and flexible laryngoscopy.Methods: Two healthy volunteers were recruited to undergo both flexible and rigid laryngoscopy. An OPS was used to quantify aerosols and droplets generated for four positive controls relative to ambient particles (speech, breathing, /e/ phonation, and /æ/ phonation) and for five test interventions relative to breathing and phonation (flexible laryngoscopy, flexible laryngoscopy with humming, flexible laryngoscopy with /e/ phonation, rigid laryngoscopy, and rigid laryngoscopy with /æ/ phonation). Particle counts in mean diameter size range from 0.3 to >10 μm were measured with OPS placed at 12 cm from the subject's nose/mouth.Results: None of the laryngoscopy interventions (n = 10 each) generated aerosols above that produced by breathing or phonation. Breathing (n = 40, 1–3 μm, P = .016) and /æ/ phonation (n = 10, 1–3 μm, P = .022; 3–5 μm. P = .083; >5 μm, P = .012) were statistically significant producers of aerosols and droplets. Neither speech nor /e/ phonation (n = 10 each) were associated with statistically significant aerosols and droplet generation.Conclusions: Using OPS to detect droplets and aerosols, we found that office laryngoscopy is likely not an aerosol‐generating procedure. Despite its prior use in otolaryngological literature, an OPS has intrinsic limitations. Our study should be complemented with more sophisticated methods of droplet distribution measurement.Level of Evidence: 3 Laryngoscope, 130:2637–2642, 2020


  • Recurrence of benign phonotraumatic vocal fold lesions after microlaryngoscopy

    by Mark Lee, Lucian Sulica

    Objectives: To determine recurrence rates for benign phonotraumatic vocal fold lesions after microlaryngoscopic surgery.Study Design: Retrospective review.Methods: Records of adults who underwent microlaryngoscopy between 2006 and 2017 for vocal fold cysts, midfold masses, polyps, pseudocysts, sulcus vocalis (Ford type 3), and varices were reviewed for demographics, medical history, treatment, and lesion recurrence. Patients operated for nonphonotraumatic lesions (e.g., granuloma, keratosis/leukoplakia, papilloma) were excluded. Stroboscopic examinations were re‐reviewed to confirm diagnosis and outcome.Results: Five hundred ten adults (223 male:287 female; mean age 40.3 ± 14.9 years) were included. Overall, 62 of 510 (12.2%) recurred (median time to recurrence: 70.0 months). Of these, 44 (71.0%) recurred to the same lesion type and 49 (79.0%) to the same side. Recurrence rates by initial lesion type were as follows: cysts, two of 92 (2.2%); midfold masses, four of 18 (22.2%); polyps, 25 of 235 (10.6%); pseudocysts, 30 of 145 (20.7%); sulcus vocalis, one of 18 (5.6%); and varices, zero of two (0%) (χ 2 = 28.7, degrees of freedom [df] = 5, P < 0.001). No significant difference in recurrence existed between males (21 of 223, 9.4%) and females (41 of 287, 14.3%). However, young adults (17 of 86, 19.8%) had significantly higher recurrence rates compared to middle‐aged (12 of 155, 7.7%) and older adults (3/60, 5.0%) (χ 2 = 9.5, df = 3, P = 0.023). Of 62 recurrences, 18 were re‐operated and four re‐recurred.Conclusion: Benign phonotraumatic vocal fold lesions recur at variable rates. This variation suggests pathophysiologic differences between categories that may not be entirely explained by behavioral factors.Level of Evidence: 4 Laryngoscope, 130: 1989–1995, 2020